Thermal Response Test Equipment. Specifications



Similar documents
Albert Złotkowski*, Patrycja Szczesiul** AN ANALYSIS OF A TEMPERATURE CHANGE IN A CROSS SECTION OF BOREHOLE HEAT EXCHANGER***

SMS Database System Quick Start. [Version 1.0.3]

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Overheating limit control

Refrigerated Air Dryers. Catalogue

Solar Hot Water Heaters

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

FUNDAMENTALS OF CONTROL ENGINEERING

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Remote Monitoring Solutions for Noise, Vibration and others.

BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT

Refrigeration Air Dryers. Catalogue

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Field test of a novel combined solar thermal and heat pump system with an ice store

How To Set Up An Inverter

Designed for multi-injector endurance testing, the


SOLAR HEATING SYSTEMS.

Hybrid Geothermal / Solar Thermal HVAC System: Part1 Design (OU Human Health Building)

Energy Conversions I. Unit of measure (most common one) Form Definition Example

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

Engineered Solutions

ECOCIAT. Domestic hot water heat recovery unit

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July Prepared by

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

Energy Efficiency. Energy Efficient Water Heating: Purchasing a new electric water heater. Hot water use has a significant impact on your bill.

Cisco Nexus 7000 Series Power Supply Modules

Fluxi 2000/TZ Turbine Gas Meter

COMPUTERIZED SYSTEMS FOR FILM THICKNESS CONTROL AND PRODUCT QUALITY CERTIFICATION

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Ordino Autoclave Controller CS340 CS350 CS400 CS360

How to Test a Combi Control Unit

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

How To Use An Akua Magnetic Lime Scale Preventing Device

Hydraulic Control Solutions

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

stainless steel pre-assembled manifolds

Exploitation Tests of Borehole Heat Exchangers in the Laboratory of Renewable Energy Sources in Miekinia Poland

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Lockout - Tagout. Control of Hazardous Energy OSHA Standard

Instruction Manual IM/LM_3. Field IT. Data Capture Utility. LogMaster

Benefits of. Air Flow Management. Data Center

Midland Combustion Electric Line Heaters with Integral Panels

Electronic Control Devices The European Product Catalogue 2007

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

VAD Variable Area Desuperheaters

Oil and Coolant Circulating Heating System. Model - OCSM

External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)

Measuring Method and Calculation Formula for the Electricity Consumption of Coffee Machines for Household Use

What you don t know about industrial GSM/GPRS modem communications

Technical data. Danfoss DHP-A

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

SMS Alarm. User Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

User Manual HomeGrid 3000 Solar Generator

Delivering exceptional performance and Ecovalue. Ecocent

Fundamentals of Power

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Server Technology, Inc.

Split units TH with hermetic compressors

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Test Report issued under the responsibility of:

VAD. Variable Area Desuperheaters

Benefits of Cold Aisle Containment During Cooling Failure

Solenoid valves Type EVU

ENGINE COOLING SYSTEM

Error Codes: 02F. Model: (110. = Whirlpool) S/N: CSP Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Digital Camera Monitoring Technologies, Systems, and Products

P08 Köldmedier med låg växthuseffekter

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

FVA/A1 saturated-steam sterilizer

ECOplus Solar Cylinder

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

Application Guide Guardian Over the NET Server Room Solution

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov to Mar. 15, 2004.

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Dual Heat Transfer Coils. Catalog 4295 Revised, December

COST EFFECTIVE AND EFFICIENT INDUSTRIAL TANK CLEANING PROCESS

1 WATERFLUX - Comparisonon COO Rectangular Magmeter in water applications

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Server application Client application Quick remote support application. Server application

Three-years operation experience of a ground source heat pump system in Northern Greece

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

MOUNTING AND OPERATING INSTRUCTIONS

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

DIGITAL WARMING CABINETS

How To Improve Energy Efficiency In A Data Center

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

SMM. Installation Operation Maintenance

Transcription:

Thermal Response Test Equipment Specifications Made by: László Kiss Executive manager mechanical engineer, specialist automation and geothermal engineer and Barna Erdélyi mechanical engineer, geophysicist engineer, specialist geothermal engineer Lanna Ltd. H 2527 Máriahalom, Petőfi u. 23.

TABLE OF CONTENTS 1. SHEMA 2. PRESENTATION 3. LIST OF INSTRUMENTS 4. STRUCTURAL SHEMA OF TRT EQUIPMENT 5. PHOTO OF HEATING TRT DEVICE 6. PHOTO OF COOLING TRT DEVICE 7. PHOTOS FROM IT DEVICES TRT Equipment Specifications 1 / 11

1. SHEMA A; TRT Equipment for Heating Test: TRT Equipment Specifications 2 / 11

B; TRT Equipment for Cooling Test: TRT Equipment Specifications 3 / 11

2. PRESENTATION HOW TO USE THE DEVICE HEATING TEST: 1. plug it in 2. fill it up with fluid. Pressure: 2 bar < p < 3 bar 3. connect the device to internet 4. choose a measurement program 5. start it COOLING TEST: It gives 7kW cooling. The cooling machine works with the heating machine in a linear way. DATA SAVE: The data are operated by SAIA PLC system Real-time data information through internet The measuring intervals can be programmed Dataform: EXCEL Metal device box EU standard documents MEASURED PARAMETERS BY TRT EQUIPMENT: - inlet and outlet heat carrier fluid temperature at the connection points between the U-pipe and the TRT equipment in the function of time, - outer environmental air temperature in the function of time, - heat carrier fluid massflow in the function of time, - effective heating power in the function of time (without pump!), - threshold pressure of TRT equipment. TRT Equipment Specifications 4 / 11

3. LIST OF INSTRUMENTS LIST OF INSTRUMENTS NAME TYPE VALUE Nr.1. pressure switch DANFOSS 160 KP1 060-1101 0-12 bar Nr.2. thermometer in WTS PT1000 class B -20 C +105C 0,4 11,1 liter/sec 2.0 accuraty class EN1434 C environmental EN1434 Nr.3. volumetic meas. CF ECHO2, with ultrasonic OIML R75 class PTB C class SP test -2% Nr.4. electricity meas. ALE3D5FS10C3A00 SAIA PED conformity 3x65A P WATT U VOLT Sbus, MID Nr.5. thermometer out WTS PT1000 class B -20...105C Nr.6. thermometer outside WTS PT1000 class B -20...105C Nr.7. thermometer T 2 WTS PT1000 class B -20...105C Nr.8. thermometer T 1 WTS PT1000 class B -20...105C Nr.9. PLC SAIA PLC system Nr.10. GSM modem SAIA PCD3 GPRS comm. TRT Equipment Specifications 5 / 11

4. STRUCTURAL SHEMA OF TRT EQUIPMENT TRT Equipment Specifications 6 / 11

5. PHOTO OF HEATING TRT DEVICE TRT Equipment Specifications 7 / 11

The TRT equipment is under power: TRT Equipment Specifications 8 / 11

6. PHOTO OF COOLING TRT DEVICE TRT Equipment Specifications 9 / 11

7. PHOTOS FROM IT DEVICES Web panel: TRT Equipment Specifications 10 / 11

GSM modem: The IT devices service: - on-line connection with the TRT equipment via the internet, - on-line measuring setup and monitoring, - on-line data downloading, - on-line monitoring of the technical parameters (pressure, power) of the TRT equipment, - shut downing of the TRT equipment at the end of measuring via internet, - SMS sending if a technical error happens during the measuring. TRT Equipment Specifications 11 / 11