DX6400 QUICK REFERENCE GUIDE. 821001214 (Rev. E)



Similar documents
DS8100A QUICK REFERENCE GUIDE (Rev. D)

DS6300 QUICK REFERENCE GUIDE (Rev. J)

Industrial Bar Code Scanners

Industrial Bar Code Scanners

Industrial Bar Code Scanners

Industrial Bar Code Scanners

Matrix 400 QUICK REFERENCE GUIDE

TCNM AD/EX Barcode Scanner. Instruction Manual

AXIS 291 1U Video Server Rack Installation Guide

FACTORY AUTOMATION MANUAL VB6-240-V BARCODE SCANNER

Barcode Reader Series BCL 31, BCL 32, BCL 34

MCR1900 Media Converter 19-Slot Chassis

FACTORY AUTOMATION MANUAL VB6-240

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

FACTORY AUTOMATION LASER BARCODE SCANNERS FOR INDUSTRIAL AUTOMATION

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Electronic Control Devices The European Product Catalogue 2007

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

User manual Compact Web PLC WP240 series IEC-line

Perle 10/100 Ethernet Media Converters

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

BroadBand PowerShield. User Manual

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

High Performance Visible Laser Diode Scanners

How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (

DS1500. Tx Data/Active LED. Laser On LED. Warning and Device Class Label. Figure A

Laser Barcode Scanner

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Cross-beam scanning system to detect slim objects. 100 mm in

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

DS2X00N-DS4800 SCANNER FAMILY

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

PCS0100en Persy Control Services B.V. Netherlands

Bar code scanners CLV45x / CLV450 / Standard Density

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

Bar code scanners CLX49x / CLX490 / Standard Density

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Perle 10/100/1000 Ethernet Media Converter Module

Laser Barcode Scanner User s Manual

InnoMedia ESBC B. Quick Install Guide. 1

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

QUICK REFERENCE GUIDE

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Perle Protocol Transparent Media Converter Modules

FCC COMPLIANCE STATEMENT

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

InnoMedia ESBC B. Quick Install Guide. 1

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

Electronic Control Devices The European Product Catalogue 2007

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Backup Scanner Module

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

DT105X / PB105 Series

DK40 Datasheet & Hardware manual Version 2

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

10/100/1000 Base-T to Gigabit Fiber Media Converter

HS-251xW-TS Series Laser Barcode Scanner User s Manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

VOICE RECORDING SYSTEM ISDN PRI / BRI

CLV440/442 Bar Code Scanner

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

USB Plus+ RFID Reader Setup Guide

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

L5354 ControlNet Communications Interface

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

AXIS 241Q/S Blade - Rack Solution Installation Guide

ADACSNET USB Control Module

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

About the HotWire Slot Standalone Shelf

C24-CAMANL Video Server/Encoder

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

Disclaimers. Important Notice

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Multifunction devices

DMX USB PRO. User Manual.

Overview of Cisco 2600 Series Routers

I STAR COMPUTER CO., LTD

MATRIX 210. Host Mode Programming

LwLVision-USB 2.0. Installation Guide

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon Telephone: (541) Fax: (541)

VISION. Data VS2 DATAVS2

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Transcription:

DX6400 QUICK REFERENCE GUIDE 8004 (Rev. E)

UPDATES AND LANGUAGE AVAILABILITY UK/US I F D E The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a: www.automation.datalogic.com Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française. Cliquez sur : www.automation.datalogic.com Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem Produkt. Die deutschsprachige Version dieses Handbuches ist auch verfügbar. Adresse : www.automation.datalogic.com En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. También está disponible la versión en español de este manual. Dirección Internet : www.automation.datalogic.com SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.automation.datalogic.com and click on the links indicated for further information: PRODUCTS Search through the links to arrive at your product page which describes specific Info, Features, Applications, Models, Accessories, and Downloads including the Genius utility program, which allows device configuration using a PC. It provides RS3 and Ethernet interface configuration. SERVICE - Overview - Warranty Extensions and Maintenance Agreements - Sales Network- Listing of Subsidiaries, Repair Centers, Partners - Helpdesk - Material Return Authorization LEGAL NOTICES 003-00 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest extent under U.S. and international laws. Copying, or altering of this document is prohibited without express written consent from Datalogic Automation S.r.l. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Genius, PackTrack, Step-a-Head, FLASH, ACR, and ID-NET are trademarks of Datalogic Automation S.r.l. All other brand and product names mentioned herein are for identification purposes only and may be trademarks or registered trademarks of their respective owners. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.

DX6400 GENERAL VIEW Figure A Laser Beam Output Windows Laser Safety Label 3 5 4 3 Figure B Standard 3 Programming Keypad TX Data LED (Green) Phase On LED (Yellow) 4 5 Power On LED (Red) LCD Display 3 4 Ethernet Figure C 3 4 Lonworks 9-pin Male Connector Lonworks 9-pin Female Connector Serial Interface and I/O 5-pin (6-pin) male Connector RJ45 Modular Connector for Ethernet Interface NOTE For further details on product installation, see the complete Reference Manual available on the configuration CD-ROM included with this product. 3

CONNECTIVITY Examples of the most common system layouts are shown in this section, for additional layouts refer to the Reference Manual. Local Lonworks Networks CAB-Sxx CAB-60x BT-6000 CBX00** Master Local Host Slave P.S.* I/O, AUX BT-6000 CAB-63xx PWR-0 * P.S. (Presence Sensor) connected to Input (External Trigger/PS) input. ** CBX00 jumper set to accept scanner power. Small Synchronized Network with Readers CAB-60x BT-6000 CBX00** CAB-60x Slave 3 Slave 4 Master I/O, AUX, Encoder*** P.S.* Local Host Slave Slave PWR-40 CAB-60x CAB-650x CAB-F0x CAB-63xx BTK-80 CAB-63xx Note: In a mixed 8K and 6K family scanner network, only the 8K family scanner can be Master * P.S. (Presence Sensor) connected to Input (External Trigger/PS) input. ** CBX00 jumper set to accept scanner power. *** Encoder connected to Input (Encoder) input. Synchronized Network with DS800A Master and 6K Family Slaves - Serial Host 4

Fieldbus CAB-60x BT-6000 CBX00** Slave 3 Slave 4 Remote Host CAB-60x Master* I/O, AUX, Encoder*** P.S.* Slave Slave PWR-40 CAB-60x CAB-60x CAB-63xx CAB-F0x CAB-63xx * P.S. (Presence Sensor) connected to Input (External Trigger/PS) input. ** CBX00 jumper set to accept scanner power. *** Encoder connected to Input (Encoder) input. Synchronized Network with DX6400 Master and 6K Family Slaves - Fieldbus Host P.S.* P.S.* P.S.* P.S.* Slave 3 Slave Slave Master BT-6000 CAB-6x PG6000 CAB-6x PG6000 PG6000 CAB-6x BT-6000 PG6000 CAB-Sxx CAB-Sxx CAB-Sxx CAB-Sxx Local Host CBX00 * Each P.S. (Presence Sensor) connected to Input (External Trigger/PS) input. Multidata Network NETWORK TERMINATION When building a local Lonworks system the network must be properly terminated by positioning a BT-6000 terminator on the DX6400 master reader (BT-6000 female side) and on the last slave reader (BT-6000 male side). to Master 9-pin female to Slave 9-pin male BT-6000 Network Terminator 5

ELECTRICAL CONNECTIONS The details of the connector pins are indicated in the following tables: The table below gives the pinout of the CBX00/CBX500 terminal block connectors. Use this pinout when the DX6400 reader is connected by means of the CBX00/CBX500: CBX00/500 Terminal Block Connectors Power Vdc Power Supply Input Voltage + GND Power Supply Input Voltage - Earth Protection Earth Ground Inputs +V Power Source Inputs -V Power Reference Inputs IA EXT TRIG/PS A (polarity insensitive) for PS IB EXT TRIG/PS B (polarity insensitive) for PS IA IN /ENC A (polarity insensitive) for Encoder IB IN /ENC B (polarity insensitive) for Encoder I3A IN 3A (polarity insensitive) (only with CBX500) I4A IN 4A (polarity insensitive) (only with CBX500) I34B IN 3B/IN 4B Reference (polarity insensitive) (only with CBX500) Outputs +V Power Source - Outputs -V Power Reference - Outputs O+ OUT + O- OUT - O+ OUT + O- OUT - O3A OUT 3A (polarity insensitive) (only with CBX500) O3B OUT 3B (polarity insensitive) (only with CBX500) Auxiliary Interface TX Auxiliary Interface TX RX Auxiliary Interface RX SGND Auxiliary Interface Reference Shield Shield Network Cable Shield Main Interface RS3 RS485 Full-Duplex RS485 Half-Duplex TX TX+ RTX+ RTS TX- RTX- RX *RX+ CTS *RX- SGND SGND SGND * Do not leave floating, see Reference Manual for connection details. CAUTION Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc. 6

The DX6400 scanner provides a 5-pin (6-pin for Ethernet models) male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals. 5-pin / 6-pin D-Sub Connector Pinout Pin Name Function CHASSIS Chassis - internally connected to GND Cable shield connected to chassis 0 RXAUX Receive data of auxiliary RS3 (referred to GND) TXAUX Transmit data of auxiliary RS3 (referred to GND) 8 OUT + Configurable digital output positive pin 3 OUT - Configurable digital output negative pin OUT + Configurable digital output positive pin 4 5 OUT - Configurable digital output negative pin 6 OUT 3A Configurable digital output 3 polarity insensitive 5-pin male D-sub Connector 7 OUT 3B Configurable digital output 3 polarity insensitive 8 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 9 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 9 6 IN/ENC A Input signal (polarity insensitive) for Encoder 0 8 0 IN/ENC B Input signal (polarity insensitive) for Encoder 9 6 4 IN3A Input signal 3 (polarity insensitive) 6-pin male D-sub Connector 5 IN4A Input signal 4 (polarity insensitive) 4 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9, 3 VS Supply voltage positive pin 3, 5, 6 GND Supply voltage negative pin Main Interface Pin RS3 RS485 Full-Duplex RS485 Half-Duplex TX TX485+ RTX485+ 3 RX * RX485+ 4 RTS TX485- RTX485-5 CTS * RX485-7 GND_ISO GND_ISO GND_ISO * Do not leave floating, see Reference Manual for connection details. Two 9-pin connector(s) provide access to the scanner s local Lonworks network. The Master/Slave model has two Lonworks connectors used for both input and output connections to build a multi-sided or omni-station system. The Fieldbus model (Ethernet) has one Lonworks connector and therefore can be used in a Lonworks network only as a Master. 9-pin Lonworks Connector Pinout Pin Name Function CHASSIS Cable shield internally connected by capacitor to chassis 9 VS Supply voltage positive pin GND Supply voltage negative pin 6 VS_I/O Supply voltage of I/O circuit 3 Ref_I/O Reference voltage of I/O circuit 4 SYS_ENC_I/O System signal 5 SYS_I/O System signal 7 LON A Lonworks line (polarity insensitive) 8 LON B Lonworks line (polarity insensitive) 5 9 6 Female 5 6 9 Male (M/S model only) 9-pin Local Lonworks Connectors 7

Ethernet Model DX6400 RJ45 Modular Connector HUB / SWITCH TX+ TX- RX+ 3 3 8 n. c. 4 4 n. c. 5 5 RX- 6 6 n. c. n. c. 7 8 7 8 RJ45 Female Connector n. c. = not connected APPENDIX TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage Power Consumption Common Communication Interfaces Model-Dependent Communication Interfaces Inputs Ext. Trigger, Encoder aux. digital inputs Outputs 3 software programmable digital outputs OPTICAL FEATURES Light Receiver Wavelength Safety Class Light Source Laser Control READING FEATURES Scan rate Maximum Resolution Max. Reading Distance Max. Reading Width Max. Depth of Field Main 5 to 30 Vdc. to 0.6 A; 8 W typical.5 to 0.7 A; 4 W Max. (including startup current) Baud Rate RS3 RS485 full-duplex 00 to 500 RS485 half-duplex Auxiliary RS3 00 to 500 Other Lonworks Ethernet (optocoupled NPN or PNP) (optocoupled) Avalanche photodiode 630 to 680 nm.5 Mb/s 00 Mb/s Class - EN6085-; Class II - CDRH Up to semiconductor laser diodes Security system to turn laser off in case of motor slow down up to 500 scans/s (750 per leg) (see reading diagrams) 8

USER INTERFACE LCD Display lines by 6 characters LCD Keypad 3 keys LED Indicators Power On (red) Phase On (yellow) TX Data (green) SOFTWARE FEATURES Readable Codes Interleaved /5 Code 39 Standard Codabar Code 8 EAN 8 Code 93 (standard and full ASCII) EAN/UPC (including Add-on and Add-on 5) GS DataBar (including Limited and Expanded) Code Selection Up to 0 codes during one reading phase Headers and Terminators Up to 8-bytes headers and 8-bytes terminators Operating Modes On Line, Serial On Line, Automatic, Test, PackTrack, Continuous Configuration Modes Parameter Storage ENVIRONMENTAL FEATURES Operating Temperature Storage Temperature Humidity Ambient Light Immunity Vibration Resistance EN 60068--6 hours on each axis Shock Resistance EN 60068--7 3 shocks on each axis Genius utility program Non-volatile internal FLASH Ethernet models 0 to +40 C (+3 to +04 F) -0 to +70 C (-4 to +58 F) 90% non condensing 0000 lux 4 mm @ to 0 Hz;.5 mm @ 3 to 55 Hz; g @ 70 to 00 Hz 30 g; ms Master/Slave models Protection Class EN 6059 IP50 IP64 PHYSICAL FEATURES Mechanical Dimensions Weight 5.9 x 49.8 x 6.8 mm (8.89 x 5.90 x 4.60 in). kg. (4.6 lbs) MODEL DESCRIPTION DX6400-00 - 0XX Decoder Model 0 = Master/Slave = Ethernet 9

ACCESSORIES Name Description Part Number Power Supplies PG600 Single unit power supply (US) 93ACC78 PG600 Single unit power supply (UK) 93ACC79 PG6000 Single unit power supply (EU) 93ACC70 PWR-0 J-box power unit 0/30 VAC 4 V 0 W 93ACC530 PWR-40 J-box power unit 0/30 VAC 4 V 40 W 93ACC070 PWR-480A J-box power unit 0/30 VAC 4 V 480 W 93ACC850 Cables and Terminators BT-6000 Bus terminator 93A0599 CAB-60 9-pin scanner/scanner connection cable m 93A050 CAB-60 9-pin scanner/scanner connection cable m 93A0530 CAB-605 9-pin scanner/scanner connection cable 5 m 93A0540 CAB-6 9-pin scanner to scanner no power cable m 93A054 CAB-65 9-pin scanner to scanner no power cable 5 m 93A055 CAB-6305 5-pin power cable Fam 6k 5 m 93ACC768 CAB-630 5-pin power cable Fam 6k 0 m 93ACC75 CAB-S0 STD cable to CBX m (5-pin to 5-pin) 93A0535 CAB-S0 STD cable to CBX m (5-pin to 5-pin) 93A0535 CAB-S05 STD cable to CBX 5 m (5-pin to 5-pin) 93A05353 CAB-S0 STD cable to CBX 0 m (5-pin to 5-pin) 93A05354 CAB-F0 6K-8K FBUS cable to CBX m (6-pin to 5-pin) 93A05355 CAB-F0 6K-8K FBUS cable to CBX m (6-pin to 5-pin) 93A05356 CAB-F05 6K-8K FBUS cable to CBX 5 m (6-pin to 5-pin) 93A05357 CAB-650 Fam 6K-8K cross cable.5 m (9-pin to 7-pin) 93A0588 CAB-6505 Fam 6K-8K cross cable 5 m (9-pin to 7-pin) 93A0589 Software Management Datalogic WebSentinel-005 Supervisor (up to 5 arrays) 93A004 Datalogic WebSentinel-00 Supervisor (up to 0 arrays) 93A005 Datalogic WebSentinel-00 Supervisor (up to 0 arrays) 93A006 Datalogic WebSentinel-03 Supervisor (up to 3 arrays) 93A007 Datalogic WebSentinel-064 Supervisor (up to 64 arrays) 93A008 Datalogic WebSentinel-8 Supervisor (up to 8 arrays) 93A009 Datalogic WebSentinel-56 Supervisor (up to 56 arrays) 93A000 * Connection Boxes CBX00 Compact Connection Box 93A30067 CBX500 Modular Connection Box 93A30068 CBX800 Gateway Connection Box 93A30077 BM00 Backup Module 93ACC808 BA00 DIN Rail Adapters for CBX 93ACC8 BA00 Bosch Adapters for CBX 93ACC8 BA900 Two Cable Glands Panel 93ACC847 Sensors MEP-593 Photocell kit PNP (PH-) 93ACC79 MEP-543 Photocell kit NPN 93ACC78 OEK- Optical encoder kit (0 m cable + spring) 93ACC770 OEK- Optical encoder kit + 0 m cable 93ACC600 Miscellaneous FBK-6000 Fast bracket kit ( pcs) 93ACC7 * DX6400 application software does not support any of the CBX500 Host Interface Module accessories nor the BM50 Display accessory. Use the CBX800 Gateway for Host Interface Applications, (Fieldbus and non Fieldbus). 0

MECHANICAL INSTALLATION The DX6400 reader can be positioned and installed in the best way possible as a result of the patented Step-A- Head TM feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position. The reading head and the decoder base can be rotated independently from each other allowing the installation even in the most critical locations. To rotate the head follow the given procedure:. detach the head from the base by unscrewing the four fixing screws; Head Screws. rotate the head in the desired position; 3. loosen but don't remove the two screws on top of the head; 4. affix the head onto the base carefully aligning the four fixing screws and progressively tightening them about half-way; 5. completely tighten the two screws on top of the head; 6. completely tighten the four fixing screws. Step-A-Head Feature Fixing Screw (4) The following diagrams give the overall dimensions of the reader and mounting bracket. They may be used for their installation: 60 [.36] 9.9 [.8] 85 [3.35] 6.5 [0.65] 5 0.98 8 0.7 N 0 0.4 4.65 0.86 4 0.5 6.8 [4.60] 7.8 [.83] 96.9 [3.8] 5.9 [4.56] 5.3 [4.93] 5.9 [8.89] = = = = 49.8 [5.90] 3. [4.45] 50.96 0 0.78 8 3. 4.5 N 4 SLOTS 0.8 N 4 SLOTS 35.37 8 3. 50.96 6 4.96 30 5. Ø4. N Ø0.6 N 06 50.96 7.83 00 3.93 8.5 N SLOTS 0.33 N SLOTS Ø8.5 Ø0.33 36.4 73..88 mm inch DX6400 Overall Dimensions ST-37 Mounting Bracket Overall Dimensions

Mount the scanner using the ST-37 mounting bracket which assures an angle of 6, as indicated in the figure below, in order to obtain an angle of 90 between the two scan lines. This guarantees an omni directional reading of the barcode, if the code label satisfies the ACR 4 conditions (see Scanner Reference Manual for details). DX6400 Mounting Position WARNING When installing several scanners, take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners. This condition could occur more frequently for side mounted applications. If these precautions are not followed, it may occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position of one of the two scanners involved. FLASH DYNAMIC FOCUS The DX6400 has an innovative linear motor designed to control the focus position of the scanner via software. This dynamic system, called FLASH, is able to move the focus position rail to rail, from the minimum position to the maximum position. The FLASH functionalities (i.e. the driving modes of the linear motor) are programmed via the Genius software tool and can operate in the following modes: - Fixed mode: the focus is set to the desired position via software (expressed in cm); - Continuous mode: the focus position is continuously running from a minimum position to a maximum position with a defined frequency; - Triggered mode: the focus position can be set depending on the received external input (photocell, barrier, serial message, etc.); - D-Flash mode: the focus position can be set depending on the measured distance between the scanner and the scanned object. This is the most innovative and flexible function that makes different software implementations possible. The D-Flash development has been based on the minimum distance detected. Thus, it can apply to the widest variety of applications. Further developments of D-Flash will be provided according to the specific application needs.

READING CONDITIONS ANSI Grade B minimum 600 scans/sec per leg The following tables describe the requirements for standard applications. Minimum Code Height for Omnidirectional Reading (mm) Conveyor Speed (m/s) 0.5.5.5 3 /5 Inteleaved Code Resolution (mm) 0.38 4 6 8 0 4 0.50 8 9 3 5 7 0.60 4 6 8 30.00 34 35 36 37 39 4 Table Minimum Code Height for Omnidirectional Reading (mm) Conveyor Speed (m/s) 0.5.5.5 3 Code 39 Code Resolution (mm) 0.38 3 5 7 9 0.50 5 6 7 9 4 0.60 8 9 0 3 6.00 8 9 30 3 3 34 Table Minimum Code Height for Omnidirectional Reading (mm) Conveyor Speed (m/s) 0.5.5.5 3 Code 8 Ean 8 Code Resolution (mm) 0.38 0 4 6 8 0 0.50 3 6 8 0 0.60 4 5 7 9 4.00 3 4 6 8 30 Table 3 Minimum Code Height for Omnidirectional Reading (mm) Conveyor Speed (m/s) 0.5.5.5 3 Codabar Code Resolution (mm) 0.38 6 8 0 4 6 0.50 0 4 6 8 30 0.60 3 5 7 9 3 34.00 36 38 40 4 44 47 Table 4 Minimum Code Height for Omnidirectional Reading (mm) Conveyor Speed (m/s) 0.5.5.5 3 EAN 8-3, UPC-A Code Resolution (mm) 0.38 3 5 7 9 0.50 3 4 5 6 8 0 0.60 5 6 7 8 9.00 4 5 6 7 8 9 Table 5 3

READING DIAGRAMS DX6400-00-0XX Resolution: 0.38 mm/5 mils -40-30 -0-0 0-0 -30-40 -50-60 -70 0-40 -50-60 -70-80 -90-00 -0-0 -30-40 -50-60 -70-80 (cm) z 0-0 0 0 x 0 0 30 40 (in) (cm) Note: x = 0 and z = 0 correspond to the edge of the DX6400 scanner as shown in the figure above. CONDITIONS Code = Interleaved /5 or Code 39 PCS = 0.90 DX6400-00-0XX Resolution: 0.50 mm/0 mils -40-30 -0-0 0-0 -30-40 -50-60 -70 0-40 -50-60 -70-80 -90-00 -0-0 -30-40 -50-60 -70-80 (in) (cm) z 0-0 0 0 x 0 0 30 40 (in) (cm) Note: x = 0 and z = 0 correspond to the edge of the DX6400 scanner as shown in the figure above. CONDITIONS Code = Interleaved /5 or Code 39 PCS = 0.90 4

COMPLIANCE See the DX6400 Reference Manual for the Declaration of Conformity. LASER SAFETY Figure A Laser Safety Label Figure B Warning and Device Class Label Identification Label The scanner is classified as a Class laser product according to EN 6085- regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the Genius Help On-Line). AVOID EXPOSURE TO BEAM CAUTION - LASER LIGHT WHEN OPEN LASER LIGHT EMITTED FROM THIS APERTURE AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE Laser Safety Labels DX6400 DATALOGIC S.p.A. Via Candini, 400 LIPPO DI CALDERARA DI RENO (BO) ITALY MANUFACTURED VOLT Amp. JANUARY 005 5-30 DC.5-0.7 MODEL No. SERIAL No. N468 This product conforms to the applicable requirements of CFR 040 at the date of manufacture. Warning and Device Class Label Device Identification Label The laser diode used in this device is classified as a Class 3B laser product according to EN 6085- regulations and as a Class IIIb laser product according to CDRH regulations. Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (35 mw at 630 ~ 680 nm). 5

POWER SUPPLY This product is intended to be installed by Qualified Personnel only. - All DX6400 Models: This device is intended to be supplied by a UL Listed Power Unit marked Class or LPS power source which supplies power directly to the scanner via the 5/6-pin connector. CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 5 of the FCC Rules. Operation is subject to the following two conditions: () This device may not cause harmful interference, and () this device must accept any interference received, including interference which may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. PATENTS This product is covered by one or more of the following patents. U.S. patents: Re. 36,5; 5,483,05; 5,99,740; 6,049,406; 6,347,740 B; 6,394,35 B; 6,443,360 B; 6,69,639 B; 6,688,54 B; 6,74,70 B; 7,6,685 B; 7,95,6 B; 5,08,77; 5,4,538; 5,466,9; 5,548,07; 6,06,89 B; 6,669,09 B; 7,000,838 B. European patents: 65,530 B; 786,734 B; 789,35 B; 85,376 B; 959,46 B9;,096,46 B;,300,798 B;,7,57 B;,363,8 B;.607,90 B. Japanese patents: 3,793,585; 4,033,958; 4,9,30; 4,376,353. Additional patents pending. 6