SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction



Similar documents
4KVA/5KVA Parallel Installation Guide

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

USER MANUAL Online UPS 6K/10K RACK

USER MANUAL Online UPS 1K/2K/3K Rack

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Inverter / Charger Installation General Operations and AC and DC Connections

USER MANUAL Online UPS 1K/2K/3K

User Manual 1K/2K/3K Online UPS

SNMP Web Management. User s Manual For SNMP Web Card/Box

Contractors Guide Central Inverter System Installation

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

TMS TANK MANAGEMENT SYSTEM

User s Manual AURORA 1.2K/2.2K

Phase Modular Finally the benefits of Modular ups are for all

How To Use A Power Supply Unit (Upu)

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

User Manual. Modular Online UPS

User s Manual. Management Software for Inverter

Anti-blackout system for grid connected solar installations (Solsafe concept)

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

User Manual WatchPower

E E V R E - R S - O S L O A L R

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

HM-W536 Install Guide

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

YSmart Technology Co.,Ltd

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Home Solar Kit Owner s Manual. Model: HS

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

Mobile Data Power Model: MDP-25

Back-UPS Pro 1300/1500 Installation and Operation

BB800 Off-Grid Solar System

RAY-MAX Integrated Solar Power Strip

is then retained absolutely without interruption.

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

GV- RK1352 Card Reader

Installation and operating instructions. Solar charge controller Solarix MPPT Z Z

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Installation and Operation Guide for PD4000 Series Power Control Center

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

LIFT CONTROL SYSTEMS CATALOGUE 2007

10000HXL31/15000HXL31/20000HXL31

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

SolarEdge Installation Guide MAN Cover goes here (right-side [odd] page)

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SOLAR POWER CONDITIONER Service Manual

Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70

Diesel Generating Set

Online UPS. PowerWalker VFI 1000R/1U

Axpert MKS-4000/KS-5000 Service manual. Axpert MKS Charger/ Inverter. Service manual

500r+ Installation and User Guide

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Photovoltaic Solar Energy Unit EESFB

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Installation Instructions for Alarm Module Kit A043F059

Wind Generator. NEMO400 Instruction Manual. Suzhou Shoot Power Equipment Co., Ltd. Serial number:

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

ACS-30-EU-EMDR-10-MOD

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

GSM HOME SECURITY SYSTEM

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

MCR1900 Media Converter 19-Slot Chassis

Battery Power Inverters

HP R12000 and R18000 DirectFlow UPS User Guide

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Electric Rotary Actuator - On/Off or programmable control actuator

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

IMPORTANT SAFETY INSTRUCTIONS

LIFT CONTROL SYSTEMS CATALOGUE 2007

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Installation and Operation Back-UPS 1250, 1300, 1500

2 Installation Explanation

PSC-A5 Solar Charge Controller Manual

SWITCHGEAR. EGP Switchgear

Home Solar Kit Owner s Manual. Model: HS

PowerCommand Paralleling System Digital MasterControl

User Manual for CH-PFC76810

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Parallel Redundant Uninterruptible Power Supply

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

70-Series CAN Power Management System

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Kelly KBS-L Brushless Motor Controller User s Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

12 Volt 30 Amp Digital Solar Charge Controller

AC Power For Business-Critical Continuity. Liebert NX UPS. Operation and Maintenance Manual 10-30kVA, 208V, 60Hz

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

46120-F0 Solar Energy Training System

Transcription:

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to 4 units. The supported maximum output power is 16KW/20KVA. 2. Three units work together to support three-phase equipment, one inverter per phase. The supported maximum output power is 12KW/15KVA. NOTE: If this unit is bundled with share current cable and parallel cable, this inverter is default supported parallel operation. You may skip section 3. If not, please purchase parallel kit and install this unit by following instruction from professional technical personnel in local dealer. 2. Package Contents In parallel kit, you will find the following items in the package: Parallel board Parallel communication cable Current sharing cable 3. Parallel board installation This installation steps are only applied to 4K/5K models. Step 1: Remove wire cover by unscrewing all screws. Step 2: Remove communication board by unscrewing two screws as below chart. 1

Step 3: Remove two screws as below chart and remove 2-pin and 14-pin cables. Take out the board under the communication board. Step 4: Remove two screws as below chart to take out cover of parallel communication. Step 5: Install new parallel board with 2 screws tightly. Step 6: Re-connect 2-pin and 14-pin to original position. Parallel board Communication board 2

Step 7: Put communication board back to the unit. Step 8: Put wire cover back to the unit. Now the inverter is providing parallel operation function. 4. Mounting the Unit When installing multiple units, please follow below chart. 500mm 500mm 500mm 500mm 500mm 500mm 500mm NOTE: For proper air circulation to dissipate heat, allow a clearance of approx. 50 cm to the side and approx. 50 cm above and below the unit. Be sure to install each unit in the same level. 5. Battery Connection WARNING! Be sure that all inverters will share the same sets of batteries. Otherwise, the inverters will transfer to fault mode. WARNING: Be sure the length of all battery cables is the same. Otherwise, there will be voltage difference between inverter and battery to cause parallel inverters not working. Follow below chart to connect batteries. All battery cables are connected from inverters to batteries via the same BUS bar. 3

Breaker BUS Bar BUS Bar Recommended battery capacity Inverter parallel numbers 2 3 4 Battery Capacity 400AH 600AH 800AH NOTE: Recommended spec of cable from inverter to BUS bar and breaker is listed as below. The cable used from BUS bar to battery should be X pcs of cable from inverter to BUS bar and breaker. X indicates the number of inverters connected in parallel. Ring terminal: Recommended battery cable and terminal size: Ring Terminal Typical Battery Model Wire Size Cable Dimensions Amperage capacity mm 2 D (mm) L (mm) 1*4AWG 22 6.4 33.2 4KVA 67A 200AH 2*8AWG 14 6.4 29.2 5KVA 84A 200AH 1*4AWG 22 6.4 33.2 2*8AWG 14 6.4 29.2 Torque value 2~ 3 Nm 2~ 3 Nm 4

6. AC Input Connection Parallel in single phase Connect Line wires of AC input from each unit to Line BUS bar. Connect Neutral wires of AC input from each unit to Neutral BUS bar. Refer to below figure for connection of AC input. Breaker Breaker Support three-phase equipment Connect Line wires of the inverter to each phase of the utility. Connect Neutral wires of AC input from each unit to Neutral BUS bar. Refer to below figure for connection of AC input. Breaker 5

WARNING: Only Line wires can be connected breaker. It s not allowed to add breaker into Neutral wires between inverter and the BUS bar. All Neutral wires are connected to the BUS bar directly, and you can add a breaker between the utility and the bus bar in the distributor. WARNING: Be sure the length of all AC input cables is the same to guarantee reliability of sharing current in each unit. WARNING: Recommended spec of cable from inverter to BUS bar and breaker is listed as below. The cable used from BUS bar to AC power should be X pcs of cable from inverter to BUS bar and breaker. X indicates the number of inverters connected in parallel. Suggested cable wire and breaker requirement for AC input connection: Model Amperage for breaker AWG no. Torque 4KVA 40 A 10 AWG 1.4~1.6Nm 5KVA 50 A 8 AWG 1.4~1.6Nm 7. AC Output (Load) Connection Parallel in single phase Connect Line wires of AC output from each unit to Line BUS bar. Connect Neutral wires of AC output from each unit to Neutral BUS bar. Refer to below figure for connection of AC output. Breaker BUS Bar BUS Bar BUS Bar Support three-phase equipment Connect Line wires of AC output from each unit to the load. Connect Neutral wires of AC output from each unit to Neutral BUS bar. Refer to below figure for connection of AC output. 6

Breaker BUS Bar BUS Bar WARNING: Only Line wires can be connected breaker. It s not allowed to add breaker into Neutral wires. All Neutral wires are connected to the BUS bar directly. WARNING: Be sure the length of all AC output cables is the same to guarantee reliability of sharing current in each unit. WARNING: Recommended spec of cable from inverter to BUS bar and breaker is listed as below. The cable used from BUS bar to AC output should be X pcs of cable from inverter to BUS bar and breaker. X indicates the number of inverters connected in parallel. Suggested cable and breaker requirement for AC output connection: Model Amperage for breaker AWG no. Torque 4KVA 40A 10 AWG 1.4~1.6Nm 5KVA 50A 8 AWG 1.4~1.6Nm 8. PV Connection Please refer to user manual of single unit for PV Connection. CAUTION: Each inverter should connect to PV modules separately. 7

9. Parallel Cable Connection Parallel cable includes parallel communication cable and current sharing cable. Please follow below chart to connect to the inverter. 9-1. Parallel Operation in Single phase Two inverters in parallel: Three inverters in parallel: Four inverters in parallel: 9-2. Support 3-phase equipment Follow below chart to connect inverters to support 3-phase equipment. 8

10. LCD Setting and Display Setting Program: This setting is only available when the inverter is in standby mode (Switch off). Program Description Selectable option Single: When the units are used in parallel with single phase, please select PAL Parallel: in program 28. Operation to support three-phase equipment is required to have three L1 phase: inverters. This setting for each unit should be different in L1 phase, L2 28 AC output mode L2 phase: phase and L3 phase separately. Please set up this setting corresponding to each phase connection. No matter it s set for parallel operation or supporting 3-phase equipment, the L3 phase: output source priority only can be set as Utility or SBU. Besides, power saving function will be automatically disabled. Fault code display: Fault Code Fault Event Icon on 60 Power feedback protection 71 Firmware version inconsistent 72 Current sharing fault 80 CAN fault 81 Host loss 82 Synchronization loss 83 Battery voltage detected different 9

84 AC input voltage and frequency detected different 85 AC output current unbalance 86 AC output mode setting is different 11. Commissioning Parallel in single phase Step 1: Check the following requirements before commissioning: Correct wire connection Ensure all breakers in Line wires of load side are open and each Neutral wires of each unit are connected together. Step 2: Switch on DC breakers of each unit. Step 3: Turn on each unit. LCD display in Master unit LCD display in Slave unit NOTE: Master and slave units are randomly defined. Step 4: Switch on all AC breakers of Line wires in AC input. It s better to have all inverters connect to utility at the same time. If not, it will display fault 82 in following-order inverters. However, these inverters will automatically restart. If detecting AC connection, they will work normally. LCD display in Master unit LCD display in Slave unit Step 5: If there is no more fault alarm, the parallel system is completely installed. Step 6: Please switch on all breakers of Line wires in load side. This system will start to provide power to the load. 10

Support three-phase equipment Step 1: Check the following requirements before commissioning: Correct wire connection Ensure all breakers in Line wires of load side are open and each Neutral wires of each unit are connected together. Step 2: Switch on DC breakers of three units. Step 3: Turn on three units. LCD display in L1-phase unit LCD display in L2-phase unit LCD display in L3-phase unit Step 4: Switch on all AC breakers of Line wires in AC input. If AC connection is detected and three phases are matched with unit setting, they will work normally. Otherwise, the AC icon will flash and they will not work in line mode. LCD display in L1-phase unit LCD display in L2-phase unit LCD display in L3-phase unit Step 5: If there is no more fault alarm, the system to support 3-phase equipment is completely installed. Step 6: Please switch on all breakers of Line wires in load side. This system will start to provide power to the load. Note 1: To avoid overload occurring, before turning on breakers in load side, it s better to have whole system in operation first. Note 2: Transfer time for this operation exists. Power interruption may happen to critical devices, which cannot bear transfer time. 11

12. Trouble shooting Fault Code Situation Fault Event Description Solution 60 Current feedback into the 1. Restart the inverter. inverter is detected. 71 1. Update all inverter firmware to the The firmware version of each same version. inverter is not the same. 72 1. Check if sharing cables are connected The output current of each well and restart the inverter. inverter is different. 80 CAN data loss 1. Check if communication cables are 81 Host data loss 82 Synchronization data loss 83 84 The battery voltage of each inverter is not the same. AC input voltage and frequency are detected different 85 AC output current unbalance 86 AC output mode setting is different. connected well and restart the inverter. 1. Make sure all inverters share same groups of batteries together. 1. Check the utility wiring conncetion and restart the inverter. 1. Restart the inverter. 1. Switch off the inverter and check LCD setting #28. 12