RMF Engineering 23 05 23



Similar documents
PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

SECTION FACILITY STORM DRAINAGE PIPING

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

INSTALLATION, OPERATION & MAINTENANCE MANUAL

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

RUBBER SLEEVE KNIFE GATE VALVE

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

PLUMBING RE-SUBMITTAL

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

FLANGED END BALL VALVE

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

A. This Section includes the following for soil, waste, and vent piping inside the building:

SECTION GENERAL REQUIREMENTS, MECHANICAL. 1. All piping entering the Shipyard must be controlled per Shipyard Standard Procedure #

C. CR: Chlorosulfonated polyethylene synthetic rubber. E. EPDM: Ethylene-propylene-diene terpolymer rubber.

James M. Pleasants Company

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

PLUMBING VALVES HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Baumann Flexsleev Sanitary Control Valve

TYPE E Main Valve Sizes 3 /8 through 12

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

NEWCO VALVES Newmans Inc., Newmans Valve Ltd. NEWCO/OIC Cast Valve Operation & Maintenance Manual

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

MADE IN THE USA BALL VA LV ES

SECTION DUCTILE IRON PIPE AND FITTINGS

V47 Series Temperature Actuated Modulating Water Valves

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

81000 Series Aluminum Gate Valve Installation and Repair Manual

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE.

Econosto UK. LEICESTER Econosto UK Ltd Cambridge Road Whetstone Leicester LE8 6ZG T: +44 (0) F: +44 (0)

HOPPER SHAPE KNIFE GATE VALVE

Flowserve - Edward Valves Development of the Flowserve Edward Equiwedge Gate Valve

SECTION MEDICAL COMPRESSED-AIR PIPING FOR HEALTHCARE FACILITIES PART 1 - GENERAL

Wastewater Capital Projects Management Standard Construction Specification

Copper and Copper Alloy Tube, Pipe and Fittings

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

FIRING RANGE PHASE 1 DESIGN

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Crane Cast Steel Valves

Materials : Cast iron body

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

Mechanical Installation

Victaulic Standard Grooved and Advanced Grooved (AGS) Piping System for IPS Steel 2 (DN 50) through 60 (DN1500)

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

GS-General Service Control Valves

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

ENERGYPETROL S.A. STOCK DE MATERIALES PARA ENTREGA INMEDIATA SALVO VENTA PREVIA

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

American- Darling 5¼" B-84-B-5.

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Baumann 24000SB Barstock Control Valve

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

EMERGENCY PLUMBING FIXTURES

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

VALVEWORKS USA OPERATION AND SERVICE MANUAL FOR MODEL FM 2 4-1/16 GATE VALVE

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Trunnion-Design Ball Valves

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper

SECTION COMMERCIAL PLUMBING FIXTURES

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Baumann Way Bronze or Stainless Steel Control Valve

Stainless Steel Valves For the Sanitary Industries

Flanged and Butt-= Weld Type

THE PROFESSIONAL'S CHOICE. WHOLESALE CATALOG

NFPA31FuelOilPiping 1 Revised

Stockham Iron Valves. Setting The Standard In Service

Morrison Bros. Co. General Product Specifications

General Data... 5 Materials... 6 Pressure/Temperature Ratings... 7 C V

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Valve Inspection and Testing

Specification Data CM /10. Putting You In Control Series MiniTork ll Control Valves. Heavy Duty Control Butterfly Valves

Type 119 Control Valve

Float and Thermostatic Traps Series H, C and X

SECTION DUCTILE IRON PIPE AND FITTINGS

Department of Energy Fundamentals Handbook. MECHANICAL SCIENCE Module 4 Valves

REGULATORS 175/153 Series

Rental Services Temporary Cooling - Flexible Water Hose

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Round Housing with Side Ports

WATER SERVICE 2

Transcription:

PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Brass ball valves. 2. Iron gate valves. 3. Bronze globe valves. B. Related Sections: 1. Division 23 HVAC piping Sections for specialty valves applicable to those Sections only. 2. Division 23 Section "Identification for HVAC Piping and Equipment" for valve tags and schedules. 1.3 DEFINITIONS A. CWP: Cold working pressure. B. EPDM: Ethylene propylene copolymer rubber. C. NBR: Acrylonitrile-butadiene, Buna-N, or nitrile rubber. D. NRS: Nonrising stem. E. OS&Y: Outside screw and yoke. F. RS: Rising stem. G. SWP: Steam working pressure. 1.4 SUBMITTALS A. General: Submit the following in accordance with conditions of Contract and Division 1 Specification Sections. B. Product Data: For each type of valve indicated. C. Shop Drawings: Submit manufacturer s assembly-type (exploded view) shop drawings for each type of valve, indicating dimensions, weights, materials, and methods of assembly of components. 23 05 23-1

D. Maintenance Data; Submit maintenance data and spare parts lists for each type of valve. Include this data, product data, and shop drawings in Maintenance Manual; in accordance with requirements of Division 1. 1.5 QUALITY ASSURANCE A. Source Limitations for Valves: Obtain each type of valve from single source from single manufacturer. B. ASME Compliance: 1. ASME B16.10 and ASME B16.34 for ferrous valve dimensions and design criteria. 2. ASME B31.1 for power piping valves. 3. ASME B31.9 for building services piping valves. C. Manufacturers Standardization Society of the Valve and Fittings Industry (MSS) Compliance: Comply with the various MSS Standard Practices referenced. D. ANSI Compliance: For face-to-face and end-to-end dimensions of flanged or welded-end valve bodies, comply with ANSI B16.10 Face-to-Face and End-to-End Dimensions of Ferrous Valves. 1.6 DELIVERY, STORAGE, AND HANDLING A. Prepare valves for shipping as follows: 1. Protect internal parts against rust and corrosion. 2. Protect threads, flange faces, grooves, and weld ends. 3. Set gate and globe valves closed to prevent rattling. 4. Set ball valves open to minimize exposure of functional surfaces. B. Use the following precautions during storage: 1. Maintain valve end protection. 2. Store valves indoors and maintain at higher than ambient dew point temperature. If outdoor storage is necessary, store valves off the ground in watertight enclosures. PART 2 - PRODUCTS 2.1 GENERAL REQUIREMENTS FOR VALVES A. Refer to HVAC valve schedule articles for applications of valves. B. Valve Pressure and Temperature Ratings: Not less than indicated and as required for system pressures and temperatures. C. Valve Sizes: Same as upstream piping unless otherwise indicated. D. Valve Actuator Types: 1. Handwheel: For valves other than quarter-turn types. 23 05 23-2

2. Handlever: For quarter-turn valves NPS 6 and smaller. E. Valves in Insulated Piping: With 2 inch stem extensions and the following features: 1. Gate Valves: With rising stem. 2. Ball Valves: With extended operating handle of non-thermal-conductive material, and protective sleeve that allows operation of valve without breaking the vapor seal or disturbing insulation. F. Valve-End Connections: 1. Solder Joint: With sockets according to ASME B16.18. 2. Threaded: With threads according to ASME B1.20.1. G. Valve Bypass and Drain Connections: MSS SP-45. H. Flanges: Comply with ASTM A-216 for steel and ANSI B16.24 for bronze valves. I. Provide valves with features indicated and, where not otherwise indicated, provide proper valve features as determined by Installer for installation requirements. Comply with ASME B31.1 for Power Piping. J. Valve Design: Select and install valves with outside screw and yoke stems, except provide inside screw non-rising stem valves where headroom prevents full opening of OS&Y valves. K. Non-Metallic Disc: Limit selection and installation of valves with non-metallic discs to locations indicated and where foreign materials in piping system can be expected to prevent tight shutoff of metal seated valves. L. Renewable Seats: Select and install valves with renewable seats, except where otherwise indicated. M. Fluid Control: Except as otherwise indicated, install ball valves to comply with ANSI B31.9. Where throttling is indicated or recognized as principal reason for valve, install globe valves. 2.2 BRASS BALL VALVES A. Two-Piece, Full-Port, Brass Ball Valves with Stainless-Steel Trim: b. Crane Co.; Crane Valve Group; Jenkins Valves. c. Flow-Tek, Inc.; a subsidiary of Bray International, Inc. d. Hammond Valve. e. Jamesbury; a subsidiary of Metso Automation. f. Kitz Corporation. g. Marwin Valve; a division of Richards Industries. h. Milwaukee Valve Company. i. RuB Inc. 23 05 23-3

2.3 IRON GATE VALVES a. Standard: MSS SP-110. b. SWP Rating: 150 psig. c. CWP Rating: 600 psig. d. Body Design: Two piece. e. Body Material: Forged brass. f. Ends: Threaded. g. Seats: PTFE or TFE. h. Stem: Stainless steel. i. Ball: Stainless steel, vented. j. Port: Full. A. Class 125, NRS, Iron Gate Valves: b. Crane Co.; Crane Valve Group; Jenkins Valves. c. Crane Co.; Crane Valve Group; Stockham Division. d. Flo Fab Inc. e. Hammond Valve. f. Kitz Corporation. g. Legend Valve. h. Milwaukee Valve Company. i. NIBCO INC. j. Powell Valves. k. Red-White Valve Corporation. l. Watts Regulator Co.; a division of Watts Water Technologies, Inc. m. Zy-Tech Global Industries, Inc. a. Standard: MSS SP-70, Type I. b. NPS 2-1/2 to NPS 12, CWP Rating: 200 psig. c. Body Material: ASTM A 126, gray iron with bolted bonnet. d. Ends: Flanged. e. Trim: Bronze. f. Disc: Solid wedge. g. Packing and Gasket: Asbestos free. B. Class 125, OS&Y, Iron Gate Valves: b. Crane Co.; Crane Valve Group; Jenkins Valves. c. Crane Co.; Crane Valve Group; Stockham Division. d. Flo Fab Inc. e. Hammond Valve. f. Kitz Corporation. 23 05 23-4

g. Legend Valve. h. Milwaukee Valve Company. i. NIBCO INC. j. Powell Valves. k. Red-White Valve Corporation. l. Watts Regulator Co.; a division of Watts Water Technologies, Inc. m. Zy-Tech Global Industries, Inc. a. Standard: MSS SP-70, Type I. b. NPS 2-1/2 to NPS 12, CWP Rating: 200 psig. c. Body Material: ASTM A 126, gray iron with bolted bonnet. d. Ends: Flanged. e. Trim: Bronze. f. Disc: Solid wedge. g. Packing and Gasket: Asbestos free. 2.4 BRONZE GLOBE VALVES A. Class 125, Bronze Globe Valves with Nonmetallic Disc: b. Crane Co.; Crane Valve Group; Stockham Division. c. NIBCO INC. d. Red-White Valve Corporation. a. Standard: MSS SP-80, Type 2. b. CWP Rating: 200 psig. c. Body Material: ASTM B 62, bronze with integral seat and screw-in bonnet. d. Ends: Threaded or solder joint. e. Stem: Bronze. f. Disc: PTFE or TFE. g. Packing: Asbestos free. h. Handwheel: Malleable iron, bronze, or aluminum. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine valve interior for cleanliness, freedom from foreign matter, and corrosion. Remove special packing materials, such as blocks, used to prevent disc movement during shipping and handling. B. Operate valves in positions from fully open to fully closed. Examine guides and seats made accessible by such operations. C. Examine threads on valve and mating pipe for form and cleanliness. 23 05 23-5

D. Do not attempt to repair defective valves; replace with new valves. 3.2 VALVE INSTALLATION A. General Application: Use gate, ball, and butterfly valves for shut-off duty; globe, ball, and butterfly for throttling duty as indicated in the contract documents. Refer to piping system specification sections for specific valve applications and arrangements. B. Insulation: Where insulation is indicated for the service, provide valves with extended stems, arranged in manner to receive insulation. Handles shall operate over full range without damaging insulation or vapor barrier seals. C. Install valves and unions for each fixture and item of equipment arranged to allow equipment removal without system shutdown. Unions are not required on flanged devices. D. Install by-pass and drain valves per MSS SP-45 or as indicated on the Contract Drawings. E. Locate valves for easy access and provide separate support where necessary. F. Install valves in horizontal piping with stem at or above center of pipe. G. Install valves in position to allow full stem movement. 3.3 ADJUSTING A. Adjust or replace valve packing after piping systems have been tested and put into service but before final adjusting and balancing. Replace valves if persistent leaking occurs. 3.4 GENERAL REQUIREMENTS FOR VALVE APPLICATIONS A. If valve applications are not indicated, use 1. Shutoff Service (Steam or Hydronic): Ball or gate valves. 2. Throttling Service (except Steam): Ball valves. 3. Throttling Service (Steam): Globe valves. B. If valves with specified SWP classes or CWP ratings are not available, the same types of valves with higher SWP classes or CWP ratings may be substituted. C. Select valves, except wafer types, with the following end connections: 1. For Copper Tubing, NPS 2 and Smaller: Threaded ends except where solder-joint valve-end option is indicated in valve schedules below. 3.5 HEATING-WATER VALVE SCHEDULE A. Pipe NPS 8 and Smaller: 1. Bronze Valves: May be provided with solder-joint ends instead of threaded ends. 2. Ball Valves: Two piece, full port, brass with stainless-steel trim. 23 05 23-6

3.6 SOCKET WELD CONNECTIONS A. Make all socket weld connections in accordance with ASME Power Piping Code B31.1. 3.7 THREADED CONNECTIONS A. Note the internal length of threads in valve ends, and proximity of valve internal seat or wall, to determine how far pipe should be threaded into valve. B. Align threads at point of assembly. C. Apply appropriate tape or thread compound to the external pipe threads (except where dry seal threading is specified). D. Assemble joint, wrench tight. Wrench on valve shall e on the valve end into which the pipe is being threaded. 3.8 FLANGED CONNECTIONS A. Align flange surfaces parallel. B. Assemble joints by sequencing bolt tightening to make initial contact of flanges and gaskets as flat and parallel as possible. Use suitable lubricants on bolt threads. Tighten bolts gradually and uniformly with a torque wrench. C. For dead-end service, butterfly valves require flanges both upstream and downstream for proper shutoff and retention. 3.9 FIELD QUALITY CONTROL A. Tests: After piping systems have been tested and put into service, but before final adjusting and balancing, inspect valves for leaks. Adjust or replace packing to stop leaks; replace valves if leak persists. 3.10 ADJUSTING AND CLEANING A. Valve Adjustment: After piping systems have been tested and put into service, but before final testing, adjusting, and balancing, inspect each valve for possible leaks. Adjust or replace packing to stop leaks, replace valve if leak persists. B. Valve Identification: Tag each valve with non-corrosive tag and Owner approved numbering scheme. C. Cleaning: Clean mill scale, grease, and protective coatings from exterior of valves and prepare valves to receive finish painting or insulation. END OF SECTION 23 05 23 23 05 23-7