SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.



Similar documents
UNIVERSITY OF ROCHESTER DESIGN STANDARDS OCTOBER 18, 2013

Ventilation Solutions Kitchens. fantech

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Evaluate, Clean, and Tune Guidance

ROOF TOP MOUNTED Air Handler Specification

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION MORTUARY REFRIGERATORS

CE6500 Energy Recovery Ventilator

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

Installation. Centrifugal Roof and Wall Exhausters

SECTION HEAT PUMPS

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller

Commercial Gas Furnace Upflow

SECTION GENERAL PROVISIONS FOR HVAC WORK

product application guide

Mechanical Rooftop Custom Capabilities

Roller Chain Coupling

SECTION AIR CONDITIONING UNIT

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

SECTION HVAC AIR DISTRIBUTION

FAIRBANKS NIJHUIS FIRE PUMPS.

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

A. Section includes air conditioning units, controls and control panels.

POWERS Controls No. 4 Pneumatic Damper Actuator

Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment

AC Electric Motors best practice

MEMBRANE VACUUM MINI PUMPS

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

Air technology solutions for demanding applications. Product overview.

Element D Services Heating, Ventilating, and Air Conditioning

Tube Type Oil Skimmer Comparison

ICQ Series - square centrifugal

COMMISSIONING OF HVAC SYSTEMS

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

AABC Specifications for Testing and Balancing HVAC Systems

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Fire Pump Plan Review March 2010

University of Houston Master Construction Specifications Insert Project Name

Owner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING!

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

We will discuss common industrial applications with guides for the proper use of electric motors on these.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

DESIGN CLARIFICATION (DC)

MAC-120HE-01 Air-Cooled Chiller

Roof Curbs, Extensions and Equipment Supports

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Diesel Engine Driven Generators Page 1 of 6

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

Johnson Air-Rotation Systems

RPV - RP - RA air handling units

Mechanical Heating Ventilation and Air Conditioning Ductwork and Duct Accessories

Horizontal Jet Pumps 1/3-1-1/2 HP

city of edmonds development information

CHILLED WATER DATA ROOM UNITS

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Operation and Installation Manual. Max Series

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

CORROSION RESISTANT FRP FANS & BLOWERS

DIVISION 23 - HVAC HVAC Air Distribution

Heating, Ventilation and Air Conditioning

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

SP H/M/L AFLR /1464/ /1469/ /22/ AFLR /8 1468/1209/ /6050/ /31/28 115

Pump Maintenance - Repair

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Ø5/16" HOLES FOR FASTENING TO CURB

Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

SUSPENSION DIAGNOSIS

ORTHOBLOC Drive systems. Installation. This manual is to be given to the end user en / k. R max - 5 mm.

Rotary Phase Converters

HVAC Design Requirements

Installation, Safety, Operation & Maintenance Instructions And Parts List

Acoustical Design Guidelines for HVAC Systems in Schools

BUYERS GUIDE. IMPORTANT: Spoken promises are difficult to enforce. Ask the dealer to put all promises in writing. Keep this form.

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Single Package Vertical Air Conditioners. Vert-I-Pak

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

New 27 hp 2 Cylinder Liquid-Cooled Engine

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

1.2 Refrigerant Equipment. General

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

Attachment J-C18.1. HVAC Work Instructions

300 Series PA Pump and Cooler Assemblies

HVAC Checklist - Long Form

Crawford Inspection Services C.C.B. #

SECTION AIR INLETS AND OUTLETS

Transcription:

PART 1 GENERAL SECTION 23 34 13 HVAC FANS 1.01 SUMMARY A. Section Includes: 1. Exhaust fans. 2. Transfer fans. B. Related Documents: 1. Drawings and general provisions of the Contract, including General Conditions and Division 1 Specification Sections, apply to the work of this Section. 2. Where contradictions occur between this Section and Division 1, the more stringent of the two shall apply. Engineer shall determine which is more stringent. 3. Motors: Comply with requirements in Division 23 Common Motor Requirements for HVAC Equipment. 1.02 DESIGN REQUIREMENTS A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer. B. Fans for smoke control systems shall comply with UL Power Ventilators for Smoke Control Systems 1.03 QUALITY ASSURANCE A. Quality Standards: 1. ARI 670. 2. Provide fans with AMCA Certified Rating Seal. 1.04 SUBMITTALS A. Submit manufacturer's product data including: 1. Performance data: a. Fan Curves. b. Sound Data. 2. Accessories descriptions. 3. Support requirements. 4. Operating weight. 5. Drawings showing: a. Dimensions of complete assembly. b. Curb if used. c. Sizes and locations of duct connections. d. Maintenance clearances. 6. Where called for in the schedule, include the fan moment of inertia (WR 2 ) and the (WR 2 ) capability of the fan motor corrected for the fan/motor speed ratio. Loveland Library HVAC FANS 23 34 13-1

PART 2 PRODUCTS 2.01 IN-LINE CENTRIFUGAL EXHAUST FANS A. Approved Manufacturers: 4. Jenn Air. 5. Penn. 6. Twin City. B. Performance: As scheduled. C. Housing: 1. Minimum 18 gauge galvanized steel with integral duct collars. 2. Bolted construction. 3. Corrosion resistant fasteners. 4. Bolted access doors on three sides. 5. Pivoting motor plate and engraved nameplate. D. Wheel: 1. Centrifugal backward inclined. 2. 100% aluminum. 3. Machined cast aluminum hub. 4. Balanced to AMCA Standard 204-96. E. Bearings: 1. Heavy duty. 2. Greasable ball-type in pillow block cast iron housing. 3. Minimum L50 life in excess of 200,000 hours at maximum operating speed. F. Belts: Oil and heat resistant, non-static type. G. Drives: 1. Machined cast iron 2. Keyed to the wheel and rotor shafts. 3. Sized for 150% of the installed motor horsepower. 4. Variable pitch where scheduled. H. Accessories: As scheduled. 2.02 CABINET EXHAUST/TRANSFER FAN A. Approved Manufacturers: 4. Jenn air. 5. Nutone 6. Penn. 7. Twin City. B. Performance: As scheduled. C. Cabinet: Steel with internal acoustic liner. Loveland Library HVAC FANS 23 34 13-2

D. Grille: Aluminum, removable. E. Wheel: Centrifugal, steel. F. Damper: Integral, backdraft flapper type. G. Accessories: As scheduled. 2.03 CENTRIFUGAL ROOF EXHAUST FANS A. Manufacturers: 4. Jenn Air. 5. Penn. 6. Twin City. B. Model and Performance: As scheduled. C. Features: 1. Aluminum housing. 2. Ball bearings. 3. Factory-fabricated roof curb. D. Accessories: 1. Bird screen. 2. Disconnect switch. 3. Backdraft damper: 0.2 inches W.C. max. pd. 4. Motorized type backdraft damper where indicated. PART 3 EXECUTION 3.01 INSTALLATION A. Install units with clearances for service and maintenance. B. Label fans according to requirements specified in Division 23 Section Identification for HVAC Piping and Equipment. 3.02 LUBRICATION A. Insure that fans are properly lubricated. 3.03 NOISE AND VIBRATION A. Insure that fans are properly supported on vibration isolators. B. Insure that flexible duct connections are properly made. C. Check fan for improper balance. Re-balance if necessary. D. Check for proper rotation. 3.04 ACCESS A. Provide for proper access to all parts of fan needing inspection or service with access Loveland Library HVAC FANS 23 34 13-3

doors in fan or ductwork. Loveland Library HVAC FANS 23 34 13-4

3.05 ADJUSTING A. Adjust belt tension. END OF SECTION Loveland Library HVAC FANS 23 34 13-5