Now That s IDEAL. Now That s IDEAL. LISTEN. RESEARCH. DESIGN. DELIVER.

Similar documents
Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

High Capacity Helical Piles Limited Access Projects

ATLAS RESISTANCE Pier Foundation Systems

New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

Stability. Security. Integrity.

System. Stability. Security. Integrity. 150 Helical Anchor

How to Design Helical Piles per the 2009 International Building Code

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Pro-Lift Steel Pile Foundation Repair

Designed and Engineered to Perform

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

Helical Piles. A Practical Guide to Design and Installation

RAM JACK INTRODUCTION

Outline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.

Transmission Foundations. helical piles and guy anchors for transmission structures.

DESIGN, INSTALLATION AND TESTING OF HELICAL PILES & ANCHORS. Presented by: Donald A. Deardorff, P.E. CHANCE Civil Construction Centralia, MO USA

Comprehensive Design Example 2: Foundations for Bulk Storage Facility

Page B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LOAD TESTS

TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR

Helical Foundation Systems

Helical Piles and Anchors Hydraulically Driven Push Piers Polyurethane Injection Supplemental Support Systems

Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils

Transmission Foundations Case History : Helical piles Hydro One Networks Inc.

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Underpinning Systems 14.1 FOUNDATION REPAIR. Helical Piles

Dynamic Load Testing of Helical Piles

load on the soil. For this article s examples, load bearing values given by the following table will be assumed.

Helical Pier Foundation System U.S. Patents 5,011,336; 5,120,163; 5,213,448

Residential Deck Safety, Construction, and Repair

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

Helical Pier Foundations

UNDERPINNING OF NEW STUDENT HOUSING BUILDING USING MICROPILES, NORTH CAROLINA USA

Design and Construction of Auger Cast Piles

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Structural Foundation System

Atlantic Foundation & Repair

LARGE DIAMETER PIPELINE INNOVATIVE FAST TRACKED REPAIR

Step 11 Static Load Testing

Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate

US 51 Ohio River Bridge Engineering and Environmental Study

POST FOUNDATION REPAIR PERFORMANCE RESIDENTIAL AND OTHER LOW-RISE BUILDINGS ON EXPANSIVE SOILS. The Repair Committee of

World Leader in earth anchoring since for Residential and Commercial Construction and Repairs

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

MANUFACTURED HOUSING USED AS DWELLINGS

ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE

PDCA Driven-Pile Terms and Definitions

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Safe & Sound Bridge Terminology

Geotechnical Building Works (GBW) Submission Requirements

The International Workshop on Micropiles, 2007

INTRODUCTION. Intro-1. Copyright 2003 Hubbell, Inc. Helical Screw Foundation System Design Manual for New Construction A.B.

E ER TITAN PRODUCTS. Foundation Repair

MAT 75 STRUCTURAL SUPPORT SYSTEM

DESIGNING STRUCTURES IN EXPANSIVE CLAY

by Greg DiBernardo Working With Helical Piers Steel piles are an affordable foundation option for small jobs and tricky sites

High Strain Dynamic Load Testing of Drilled Shafts

5/1/2013. Topics. The challenge is to better maintain native characteristics of soils during and after construction

The Do s and Don ts of Foundation Beam Installation. Presented By WAFRP Members:

SECTION 1 GENERAL REQUIREMENTS

EVALUATING INSTALLATION DISTURBANCE OF HELICAL ANCHORS IN CLAY FROM FIELD VANE TESTS

EXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

METHOD OF STATEMENT FOR STATIC LOADING TEST

CITY OF LOS ANGELES CALIFORNIA

Roller Chain Coupling

Federation of Piling Specialists July 2010

Kentucky Lake Bridge Pile Load Testing Overview Ohio Transportation Engineering Conference Columbus, Ohio 10/28/2015

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Supplier ID: Local Office: GLASGOW 69 Buchanan Street Glasgow G1 3HL

6 RETROFITTING POST & PIER HOUSES

PILE FOUNDATIONS FM 5-134

The demand for new roadway

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

GEORGE J. CAMBOURAKIS, P.E., C. ENG. PRESIDENT & CHIEF STRUCTURAL ENGINEER

Structural Failures Cost Lives and Time

Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area

BUTE Department of Construction Management and Technology

Planning Information. Passenger and Freight Elevators.

Chapter 3 Pre-Installation, Foundations and Piers

Shaft- Mounted Speed Reducers

vulcanhammer.net This document downloaded from

Robert B. Bittner, P.E., President, Ben C. Gerwick, Inc. San Francisco, CA, USA

Emergency repair of Bridge B421

Foundation Requirements and Recommendations for Elevated Homes Hurricane Sandy Recovery Fact Sheet

SECTION STORM DRAINAGE SYSTEM

MEMORANDUM West Swann Avenue, Suite 225 Tampa, Florida Phone (813) Fax (813)

Steel Design Guide Series. Column Base Plates

Introduction to Minimal Excavation Foundations

Offshore Structures. Offshore Drilling Equipment

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

DAVID A. EASTWOOD, P.E.

Transcription:

The Leading Edge SM

At IDEAL, we try not to complicate things. We discover needs and problems, then work out solutions. It takes real teamwork to accomplish truly great things. That s you and us, working together, with all the up-to-date knowledge and experience we can employ to put a project together. Now That s IDEAL. Now That s IDEAL. We specialize in manufacturing state-of-the-art products for use in the industrial, commercial, municipal, and residential industries. We make it a priority to design and produce the very best in products and equipment for applications including underpinning, tie-back anchors, and piles for new construction. We are committed to unparalleled customer service and support to ensure excellence in the design and performance of projects relating to foundation remediation, helical piling, and other foundation systems. LISTEN. RESEARCH. DESIGN. DELIVER.

New Construction LTD The Leading Edge SM Extension Early screwpiles applications lighthouse foundations Bolted Coupling First generation screwpile Lead Section Helix Tension anchor LTD (Load transfer device) CounterForce Underpinning Bracket (patent pending)

APPLICATION AND USES OF HELICAL PIERS AND ANCHORS A helical pier is a deep foundation. Its purpose is to transfer a structural load to deeper, stronger, and less compressible materials bypassing any weaker and more compressible materials that would be unsuitable for the support of a conventional shallow foundation. As a deep foundation, a helical pier should be considered for most applications that would call for a driven pile, drilled pier, or mini pile. Breakwall reinforcement Gridwork for towers Underpinning commercial building New foundations 40-100 ton capacity Boardwalk

Uses of helical piers include the support of new structures and the underpinning of existing structures that have settled excessively. Helical anchors are used for resisting upward forces, lateral forces, and overturning moments. Applications include communications towers, advertising signs, silos, below-grade tanks subjected to hydrostatic uplift, and tie-back anchors for both permanent and temporary earth-retaining structures. Light pole base Towers Train bridge underpinning New homes Retaining wall It is important to note that the uses of the helical unit continue to expand with product developments and engineering experience. Installation 80 kip tie-back anchors wall stabilization Airport weather station

FOR MANY APPLICATIONS HELICAL UNITS MAY OFFER SIGNIFICANT ADVANTAGES OVER OTHER SYSTEMS. SOME OF THESE INCLUDE: Wide range of allowable loads Adaptability to a variety of installation angles Lower cost than driven or drilled piles do not go as deep to reach the same capacity Ease and speed of installation Minimal support equipment Suitability for low-headroom and other limitedaccess areas Easy cutoffs No concrete-related delays Little or no dependence on weather Little or no earthwork and spoil material (a particular advantage at contaminated sites) Minimal vibration and noise Easily removed and reused in temporary applications Eco-Sensitive installation 300 Ton capacities Tie-back anchor installation with difficult access Difficult-to-access and low clearance pharmaceutical structures

PIPE SHAFTS HAVE THE FOLLOWING ADVANTAGES OVER SQUARE SHAFTS: Greater section modulus increased lateral stability Greater ultimate and allowable loads 7-inch standard material 300-ton ultimate capacity Less eccentricity (straighter) Greater resistance to buckling Higher torque capacity Inspectability post installation depth and plumb Can be filled with grout or concrete for increased capacity Allows for post-installation depth and plumbness inspection 1-1/2 Square: Max 5500 ft lbs. torque 2-7/8 Round: Max 8000 ft lbs. torque Round and square visual comparison of lead sections on a marine breakwall project tie-back anchors Round and square lateral stability Round shaft Square shaft

Our Mission To provide our clients and associates with Leading Edge technology, products, equipment and support to ensure excellence in the design and performance of projects relating to foundation remediation, helical piling, tension anchors and other foundation systems. The IDEAL Group 999 Picture Parkway Webster, New York 14580 1-800-789-4810