Foundation Requirements and Recommendations for Elevated Homes Hurricane Sandy Recovery Fact Sheet
|
|
|
- Damian Stokes
- 10 years ago
- Views:
Transcription
1 Foundation Requirements and Recommendations for Elevated Homes Hurricane Sandy Recovery Fact Sheet May Many homes in New York and New Jersey damaged during Hurricane Sandy experienced flood levels that exceeded the base flood elevation (BFE). The Federal Emergency Management Agency s (FEMA) Mitigation Assessment Teams (MATs) observed several construction and foundation types in the disaster area. The assessment teams also observed narrow building lots and lots with constrained access that will pose construction challenges if those homes are required to be elevated or if owners elect to elevate them to reduce exposure to future flooding (Figure 1). Base flood elevation (BFE): The height of the base (1-percent annual chance or 100-year) flood in relation to a specified datum. Flood Insurance Rate Map (FIRM): an official map of a community, on which the Federal Insurance Administrator has delineated both the special hazard areas and the risk premium zones applicable to the community. Special Flood Hazard Area (SFHA): the land in the flood plain within a community subject to a 1 percent or greater chance of flooding in any given year. This fact sheet is intended to assist architects, builders, code officials, planners, and engineers with reconstruction and new construction to create elevated flood-resistant homes. The concepts in this fact sheet will help qualified, registered design professionals (licensed engineers or architects) determine proper site-specific foundation design recommendations when working on narrow lots and lots with constrained access. This fact sheet assumes the reader is familiar with National Flood Insurance Program (NFIP) Special Flood Hazard Area (SFHA) zone designations, including Coastal A Zones. For more information about the coastal SFHA zone designations, visit coastal-mapping-basics. Figure 1: Homes on small, tightly spaced lots, typical throughout coastal New York and New Jersey, present access and construction challenges when being transitioned to a raised pile foundation (Rockaway, NY). Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes F EMA-DRs-4085-NY and NJ / May 2013 page 1 of 14
2 Of critical importance is how high a home must be elevated to reduce the risk of flooding. The minimum required elevation is based on the base flood elevation(bfe) shown on Flood Insurance Rate Maps (FIRMs), which are now being updated in many areas impacted by Hurricane Sandy to reflect changes to the physical, climatological, and scientific baseline that have occurred since the last maps were published. Shortly after Hurricane Sandy, FEMA issued Advisory BFEs (ABFEs) to help communities and homeowners make informed decisions as they rebuild. Additional elevation above the ABFE or Effective BFE, otherwise known as freeboard, may be required by a community. This fact sheet includes: A description of basic NFIP criteria as they relate to flood insurance rates. It is financially advantageous for homeowners to renovate their homes in accordance with NFIP criteria. The first three pages of the Fact Sheet summarize some of the basic concepts about the NFIP. Design guidance for restoration projects involving existing elevated homes damaged by Hurricane Sandy. Many of these homes present renovation challenges because of their location on constrained building lots or the need to elevate a closed-foundation home on an open foundation. Design guidance begins on page four of this Fact Sheet. National Flood Insurance Program Requirements Communities that participate in the NFIP are required to adopt and enforce local regulations that apply to structures and all development located in areas mapped as SFHAs. The NFIP establishes minimum criteria and design performance requirements. These criteria specify how new structures and structures that have sustained Substantial Damage or are undergoing Substantial Improvement are to be constructed to minimize or eliminate the potential for flood damage. Flood Insurance Rate Reform On July 6, 2012, President Obama approved the Biggert- Waters Flood Insurance Reform Act of 2012 (BW12) which significantly changes the NFIP rating structure used to write flood insurance policies. Flood insurance premium rates are determined based on actual flood risk. Grandfathering and Federal flood insurance premium subsidies for many older structures will be eliminated over time. For more information about BW12, consult FEMA s Flood Insurance Reform Act of 2012: Impact of changes to the NFIP (2013), available at Substantial Improvement / Substantial Damage The NFIP requires that homes within mapped flood hazard areas, if determined by a community to have sustained Substantial Damage or be undergoing Substantial Improvement, be brought into full compliance with the flood provisions of current building code and local floodplain ordinances that meet or exceed the NFIP criteria. Homes that do not meet the definitions of Substantial Damage or Designers, builders, and homeowners should consult with local building officials to determine whether local codes and regulations have more restrictive definitions and requirements, such as freeboard. Basement: Any area of the building, including any sunken room or sunken portion of a room, having its floor below ground level (subgrade) on all sides. Substantial Damage: Defined by the NFIP as damage of any origin sustained by a structure whereby the cost of restoring the structure to its before-damaged condition would equal or exceed 50 percent of the market value of the structure before the damage occurred. Substantial Improvement: Defined by the NFIP as any reconstruction, rehabilitation, addition, or other improvement of a structure, the cost of which equals or exceeds 50 percent of the market value of the structure before the start of construction of the improvement. This term includes structures that have incurred Substantial Damage, regardless of the actual repair work performed. Refer to FEMA P-758, Substantial Improvement / Substantial Damage Desk Reference (2010) for more information at viewrecord.do?id=4160. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 2 of 14
3 Substantial Improvement are not required to be elevated. However, even if not required, homeowners should consider elevating to minimize damage in the event of a flood. Elevating homes to or above the BFE will substantially lower flood insurance premiums. It is the community s responsibility to determine whether a building has sustained Substantial Damage or if proposed improvements are considered Substantial Improvements. The local official may ask homeowners for information about the costs to repair damaged homes and market value information based on a recent property appraisal. Other methods to estimate market value can be found in FEMA P-758, Substantial Improvement / Substantial Damage Desk Reference (2010). The Substantial Damage and Substantial Improvement requirements are included in community floodplain management regulations and building codes. Know the Flood Risk before Repairing or Reconstructing the Home Homeowners, builders, and design professionals need to know the flood risk for the location of the home in order to determine how high a home needs to be elevated. Most flooding that occurs is from either riverine or ocean sources. The first step in identifying flood risk is to determine whether a home is located within an SFHA and what BFE applies. This is done by reviewing the relevant FIRM and Flood Insurance Study (FIS), and talking to local floodplain administrators or building FIRMs and ABFE Maps Post-Hurricane Sandy ABFE maps are available for parts of New York and New Jersey at FIRMs for all other participating communities are available at and information on the publication of FIRMs is available at officials. The local official will confirm the location of the home using information from the FIRM and FIS. In addition, information on the source and type of flooding risks that could potentially affect the property, such as velocity flows, wave action, debris impact, and depth of flooding, is necessary to determine the type of foundation needed and other requirements. Even homes elevated sufficiently to meet minimum NFIP criteria can experience flooding above the base flood. Many communities require that homes be elevated above the BFE. Consult Hurricane Sandy Recovery Advisory No. 5, Designing for Flood Levels Above the Base Flood Elevation (2013), for more information. Advisory Base Flood Elevations: FEMA recommends that the best available data be used to plan for new construction and for homes that are being elevated or undergoing significant reconstruction or repair. This will ensure that all recovery construction is built stronger, safer, and less vulnerable to future flooding events. Some communities have adopted the ABFEs issued after Hurricane Sandy. In those communities, reconstruction and repair of residential buildings that have been determined to have incurred Substantial Damage or are undergoing Substantial Improvement must be elevated to the ABFE rather than the BFEs shown on the Effective FIRM. Freeboard, which is additional elevation above the ABFE or Effective BFE, may also be required by the community. New FIRMS. FEMA will begin to release new preliminary flood hazard information through work maps and eventually preliminary FIRMs to replace the ABFE data. Similar to the advisory data, the revised flood hazard information will be posted on FEMA s Geoplatform and for public review and use as it becomes available. Stakeholders are encouraged to check these Web sites frequently as FEMA will replace the advisory data with the preliminary data as it is developed through the year. Preliminary FIRMs will undergo a public review period and statutory appeal period prior to being adopted by communities as the Effective FIRM. In certain locations, the new FIRMs may result in higher base flood elevations or higher risk zone designations than are shown on current FIRMs. These new base flood elevations and flood risk zones will affect the minimum building requirements. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 3 of 14
4 Once the new FIRMs are published, the NFIP flood premiums will be rated using the new flood zones and BFEs. Homes elevated to the previous BFE will have flood insurance rated based on the new FIRMs and may be subject to higher premiums. Homeowners who already have elevated homes should reevaluate their risk based on the ABFEs, even if their homes had only minor damage or were not damaged during Sandy. For more information about the implications of flood insurance related to elevating a home, consult Hurricane Sandy Recovery Advisory No. 7, Reducing Flood Risk and Flood Insurance Premiums for Existing Buildings (2013). Construction Types of Buildings Damaged in Hurricane Sandy The damaged homes observed by FEMA s MATs were of several different construction types, including wood frame, masonry, and masonry veneer. Some homes had basements, some had crawlspaces, some had masonry piers, and some were slabs-on-grade. Figure 2 shows these typical foundation types. The homeowner, in conjunction with the local official and/or design professional, can decide the best course of action for a damaged home based on information from the Substantial Damage determination, the condition of the building, and an evaluation of the flood risk. Possible actions may include elevating the home, relocating it to a site outside the SFHA, or demolishing it and building a new home. If the home can be elevated, the type of compliant foundation design that can be used is determined by the construction type, foundation type, and the flood zone in which the home is located. For example, generally the most appropriate elevation technique for frame homes is to elevate on extended foundation walls or open foundations. Techniques used for masonry homes include: 1) extend the walls of the home upward and raise the lower floor to or above the required elevation; and 2) abandon the lowest floor by converting it to a garage or storage area, and move the living area to an upper floor. In terms of foundation types, slab-on-grade homes are generally more difficult to elevate than homes on basement, crawlspace, or pier foundations. Elevating homes with basement foundations involves elevating or relocating utility equipment usually found in basements and filling in the basement. Figure 2: Types of homes observed in the disaster area. Compliant Designs for Homes Located in Zone A Homes located in Zone A should have foundations that comply with local floodplain management and building code requirements. Compliance with the requirements and determination of NFIP flood insurance premiums are based on the elevation of the top of the lowest floor, which is defined as the lowest floor of the lowest enclosed area including the basement. However, unfinished or flood damage-resistant areas, usable solely for parking of vehicles, building access, or storage in an area other than a basement are not considered lowest floors, provided the areas are not built so as to render the structure in violation of the applicable design requirements. For more specific information about the NFIP criteria, consult Hurricane Sandy Recovery Advisory No. 5, Designing for Flood Levels Above the Base Flood Elevation (2013). Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 4 of 14
5 All new homes and homes determined to have sustained Substantial Damage or that will be Substantially Improved must adhere to the following criteria: All buildings must be properly anchored to resist, flotation, collapse, and lateral movement. The top of the lowest floor must elevated to, or above, the required elevation (Figure 3). Homes can be elevated on perimeter foundation walls, or on piles, piers, or columns. If permitted by the community, elevation can also be achieved by placing fill under the structure. If the community permits fill to be placed below the BFE, the fill Scour refers to a localized loss of soil, often around a foundation element due to flood flow obstruction or interaction. Scour can be determined by procedures included in FEMA P-55, Coastal Construction Manual (2011). Erosion is the process of the gradual wearing away of land masses. Erosion estimations should be based on local historical data. These data can be obtained from local and State agencies, universities, site-specific studies, and consultation with a design professional knowledgeable about the area. must be compacted and protected against scour and erosion. It is easiest to place fill before a home is constructed or, for existing homes, when the home is temporarily relocated. Basements are not permitted. To be compliant, existing below-grade areas must be backfilled. Walls of enclosed areas below elevated homes must have flood openings that allow floodwaters to automatically equalize during an event. For more information, consult FEMA NFIP Technical Bulletin 1, Openings in Foundation Walls and Walls of Enclosures (2008). Enclosed areas below elevated buildings are permitted to be used only for parking, building access, and storage. Utilities, including electrical, heating, ventilation, plumbing, air-conditioning equipment (including ductwork) must be elevated above the BFE, or specifically designed to prevent water from entering or accumulating within the components during flooding. Flood damage-resistant construction materials must be used below the BFE. For more information, consult FEMA NFIP Technical Bulletin 2, Flood Damage Resistant Materials Requirements (2008). When the lowest floor is set, and again prior to final inspection, builders must obtain elevation certificates to document compliance. Owners need these certificates to obtain NFIP flood insurance. Construction of the home and other development must not result in any increase in flood levels within the community during the occurrence of the Base Flood discharge. Figure 3: Examples of NFIP-compliant homes in Zone A where the top of the lowest floor is located above the BFE. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 5 of 14
6 Compliant Designs for Homes Located in Zone V The NFIP criteria, the community s floodplain management regulations, and building codes all require homes in coastal high hazard areas (Zone V) to have open foundations (piers, columns, or piles). Open foundations are required in areas subject to high-velocity wave action because the reduced surface area of the foundation reduces the hydrodynamic and breaking wave loads acting on the building and the building s vulnerability to scour and erosion. Foundation performance in areas subject to storm surge and wave loads improves significantly with a deep, open foundation. These foundations, including alternatives described in this fact sheet, are usually constructed with treated timber, concrete, or steel piles driven to a depth such that the strength of the foundation is not compromised by the erosion and scour common for coastal storm surges. Because the NFIP requires a licensed engineer or architect to design and certify foundations for buildings in Zone V, as well as many of the other factors that go into designing foundations, some decisions about types of foundation elements and connections are the responsibility of the registered design professional. All new homes and homes determined to have sustained Substantial Damage or that will be Substantially Improved must adhere to the following criteria: All residential buildings must be properly anchored. The NFIP requires open pile or column foundations and structures attached thereto to be anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Open foundations (piers, pilings, or columns) are required (Figure 4). Closed foundations, such as solid masonry or concrete walls, and use of fill, are not permitted. Basements are not permitted. To be compliant, existing below-grade areas must be backfilled to or above the adjacent ground surface. The bottom of the lowest horizontal structural member of the lowest floor must elevated to the required elevation. Enclosed areas below elevated buildings are permitted to be used only for parking, building access, and storage. Areas below elevated buildings must be free of obstructions. The space below the lowest floor can be enclosed by non-supporting breakaway walls, open-wood lattice work, and insect screening intended to collapse under wind and water loads. For more information, consult FEMA NFIP Technical Bulletin 5, Free of Obstruction Requirements for Buildings Located in Coastal High Hazard Areas (2008). Walls must be designed to break away under base flood conditions when used to enclose areas below elevated buildings. For more information, consult FEMA NFIP Technical Bulletin 9, Design and Construction Guidance for Breakaway Walls (2008). Flood damage-resistant construction materials must be used below the BFE. For more information, consult FEMA NFIP Technical Bulletin 2, Flood Damage Resistant Materials Requirements (2008). Utilities, including electrical, heating, ventilation, plumbing, and air-conditioning equipment (including ductwork) must be elevated on platforms, which may be attached to the building above the BFE. When the lowest floor is set, and again prior to final inspection, builders must obtain elevation certificates to document compliance. Owners need these certificates to obtain NFIP flood insurance. The design and methods of construction must be certified by a registered design professional to be in accordance with an accepted standard of practice for meeting Zone V design requirements. The current accepted standard of practice is ASCE 24, Flood Resistant Design and Construction. The IRC allows ASCE 24 to be used as an alternative to the Zone V requirements. FEMA recommends that designers use it when designing homes in Zone V. ASCE 24 has more detailed criteria and commentary and specifically requires foundation designs to account for erosion and scour, among other considerations. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 6 of 14
7 Figure 4: Examples of NFIP-compliant foundations in Zone V in which the bottom of the lowest horizontal structural member is located above the BFE. All new residential buildings must be landward of the reach of mean high tide to protect these buildings from damaging waves. Further, man-made alteration of sand dunes and mangrove stands is prohibited if potential for flood damage is increased. Solutions for Elevated Construction on Open Foundations Homes on small lots or with limited access require special methods to elevate-in-place (Figure 5). Small lots may not have adequate space on which to relocate a home while new foundation piles are driven. Horizontal and vertical clearances needed to elevate-in-place and drive traditional piles may also be inadequate. Alternative (non-timber pile) open foundations may be more feasible when lot size is a constraining factor. One solution for elevating a home on a small lot is to place a system of concrete columns and construct grade beams to support the elevated home. For more information on grade beams, consult Section of FEMA P-55, Coastal Construction Manual (2011). Another option for elevating a home on a small lot, if permitted by local building codes, is to incorporate deep foundation elements, such as micropiles, into the footings to increase building support and resist the lateral and uplift loads caused by high winds, flooding, scour, or erosion. Foundation elements such as micropiles or helical piles can Figure 5: Elevating tightly spaced homes, such as these in Breezy Point, NY, presents construction challenges. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes F EMA-DRs-4085-NY and NJ / May 2013 page 7 of 14
8 be installed even if there are minimal horizontal or low vertical clearances, and when there are limitations on disturbance to neighboring homes. Achieving proper open foundation designs for small lots may require owners to consult with a geotechnical engineer and a structural engineer, who may also need to work with an elevation contractor and a specialty foundation contractor. The need to protect neighboring homes and utilities also affects construction risks and costs, and will need to be considered when selecting the appropriate foundation alternative. Pier Foundations Pier (a type of column) foundations are typically constructed of either reinforced concrete or reinforced masonry columns. Piers are generally placed on footings to support the elevated home. Without footings, piers function as short piles and rarely have sufficient capacity to resist uplift, lateral, and gravity loads. Additionally, when exposed to lateral loads, discrete footings can rotate (Figure 6) and therefore, piers supported by discrete footings are not recommended in coastal environments. Piers supported with continuous concrete footings provide much greater resistance to lateral loads because the footings can act as an integrated unit to resist rotation. The integrated footing system must be steel reinforced to resist moment forces that develop at the base of the piers as a result of lateral loads on the foundation and elevated home. Pier foundations are typically shallow due to excavation constraints and are appropriate only where there is limited potential for erosion and scour. To prevent the continuous footing system from being undermined, the foundations must extend below the maximum estimated depth for long- and short-term erosion and localized scour. In some case, existing pier foundations may be retrofitted with grade beams to provide enhanced lateral support. See the section titled Pile Foundations for more information on grade beams. Pile Foundations Figure 6: Discrete pier footings undermined by erosion and scour in Mantoloking, NJ. Pile foundations are required in Zone V coastal environments so that waves can pass more easily under elevated homes. Traditional piles are typically constructed of treated timber, steel, or precast concrete and are driven into the ground to a depth required to resist vertical and lateral loads from gravity, wind, and flood forces. Pile foundations use the soil s resistance to support the elevated home. Critical aspects of a pile foundation include the pile size and spacing, installation method, embedment depth, bracing, and the connection to the elevated home. Piles that are properly sized, spaced, installed, and braced, and have adequate embedment into the soil (with consideration for erosion and scour effects) will perform properly and allow the home to remain standing and intact following a design flood event. For more information about scour and erosion, refer to section of FEMA s Hurricane Ike in Texas and Louisiana: Mitigation Assessment Team Report (2009). Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 8 of 14
9 Piles can be used with or without grade beams. When used without grade beams, piles extend to the lowest floor of the elevated home. Improved performance is achieved when the piles extend beyond the lowest floor to an upper floor level, although owners should check with an insurance agent to understand how the extended piles will be rated for flood insurance. Using grade beams provides resistance to rotation (also called fixity ) in the top of the embedded piles and improves stiffness of the pile foundation system against lateral loading. When used together, piles and grade beams work together to support the elevated home and transfer vertical and lateral loads imposed on the elevated home and foundation to the ground below. Design and installation of grade beams should include the following concepts: Grade beam design criteria should include resisting lateral flood loads from both hydrodynamic forces and flood-borne debris impacts. Grade beams are to provide horizontal bracing of piers or piles and should not directly support any vertical load-carrying elements such as floor slabs. They should be designed to be self-supporting between vertical foundation members, such as piles, to account for cases when erosion and scour extend below the grade beam. According to NFIP requirements, grade beams that are structurally connected to slabs are considered to be the lowest horizontal structural member supporting the slab, which is a nonconforming use below BFE and severely increases flood insurance premiums if present. Micropile Foundations Foundations supported on micropiles function similarly to deep pile foundations. Micropiles are defined in the International Building Code (IBC) as 12-inch-diameter (305mm) or less, bored, grouted-in-place piles incorporating steel pipe (casing) and/or steel reinforcement. When used for new construction, traditional driven piles are typically more cost effective than micropiles. However, micropiles may be the only feasible and cost effective retrofitting solution when access is limited, horizontal or vertical clearances are limited, or when strict control of vibrations and settlement is required (Figure 7). Figure 7: Example of a micropile drill rig. Micropiles are usually smaller in diameter than traditional piles and can be designed to perform under a wide variety of soil conditions. Micropiles can be designed to resist compressive, tensile, or shear structural loads for most situations (Figure 8a). The equipment used to install these piles is compact (such as small, front-end loader attachments), and results in less disturbance and vibration to existing homes than traditional pile-driving equipment. Current best practices, including Federal Highway Administration (FHWA) criteria described in FHWA NHI , Micropile Design and Construction Guidelines Manual (FHWA 2005) should be used to develop micropile design capacity. Micropiles can be used for underpinning applications, such as halting structural movement, repairing or replacing inadequate foundations, and providing scour and erosion protection, and can transfer loads to deeper, more competent bearing strata. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 9 of 14
10 Figure 8: Example of a grouted micropile (8a) and a helical pile (8b). With a relatively small diameter, micropiles have limited lateral capacity compared to larger traditional piles, and may require grade beams or bracing to resist lateral loads, including flood loads. The bracing must be designed to limit deflections under flood forces when exposed by scour and erosion, or under other conditions of reduced lateral soil support such as areas of soft, weak soils, soils with seismic liquefaction potential, or in areas where subsurface voids are present. A detailed geotechnical investigation must be completed to determine the quality of the bearing soil or rock strata, whether grouting is needed to fill voids, and to select an installation method (i.e., drilling through rock or boulders vs. driving piles through soft material). Helical piles are a type of micropile with an auger helix on the end of a slender shaft, which is drilled into the ground (Figure 8b). A helical pile is defined in the 2012 IBC as a manufactured steel, deep foundation element consisting of a central shaft and one or more helical bearing plates. Each helical bearing plate is formed into a screw thread with a uniform defined pitch. Helical bearing plates attached to the central shaft act as the bearing surface to resist compressive forces from the elevated structure. Increased bearing capacities can be provided by using larger diameter helixes or by attaching more piles to the foundation. As with other micropiles, there is little lateral resistance provided by the helical pile itself, so resistance must be provided by a strong moment-resisting connection to the foundation. Helical piles can be a cost-effective solution to deep/open foundation requirements where access and vertical and horizontal clearances are limited. Design Considerations To successfully elevate a home on an open foundation, site-specific conditions must be identified. Once the sitespecific conditions are identified and evaluated, a proper design can then be implemented. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 10 of 14
11 Site-Specific Design Considerations for Homes Elevated on Open Foundations Some of the site-specific factors that must be considered include soil conditions; the required elevation; the flood, wind, and seismic loads the building must be designed to resist; and whether the existing home is structurally sound enough to elevate-in-place. Table 1 presents design considerations for elevating buildings on open Table 1: Design Considerations for Elevating Buildings on Open Foundations in Zone V (and Coastal A Zones) Overall Category State and local requirements Structural condition of home Geotechnical condition of site Access, horizontal and vertical clearance on the lot Basements and crawlspaces Utilities Data Needed State and local building code requirements Local flood ordinance requirements Zoning ordinance requirements BFE or ABFE, if applicable Natural resources conservation regulations Structural strength of load paths. Determine whether the home is structurally strong enough to be lifted Structural strength of the existing footings. Determine whether the footings are adequate for the proposed modification Determine whether a shallow foundation is feasible Determine whether a deep foundation is required Predicted flood conditions, including the effects of scour and long-term erosion Elevation of the water table Potential for exposure to water or salt-laden air Availability of access for large construction equipment to the lot or possibility of temporarily relocating the home Adequacy of horizontal and vertical clearances and access Presence of a basement or crawlspace Presence of utilities located below the BFE/ABFE; utilities include mechanical, electrical, and plumbing (MEP) and heating, ventilation and air conditioning (HVAC) equipment Consider Open foundations are required in Zone V For new homes and homes that have sustained Substantial Damage or will be Substantially Improved, open foundations including piers, columns, and piles, and micropiles may be used Elevating to (or above) the BFE/ABFE will help protect the home in future storms and reduce flood insurance costs How connections can be improved to strengthen the home How the footings can be strengthened or replaced Piers/Columns are appropriate for shallow foundations Piles, piers/columns and micropiles are appropriate for deep foundations Piling and Pier/Column foundations with footings and grade beams can be designed to withstand 3-foot wave loads, but may fail if erosion and scour undermine the foundation Micropile foundations may not be able to withstand lateral loads when exposed by scour and erosion Grade beams can be elevated above the water table, but the pile or pier/column must be designed to resist cantilever action, moments, and deflection at the top. Deeper embedment may be necessary Provide corrosion protection if needed Anchors should be galvanized or grouted underground to mitigate corrosion Where there are corrosive soils or a shallow variable groundwater table and the micropile is subject to increased corrosion, micropiles should be fully grouted Traditional driven-pile foundations are often preferred if there is enough room to temporarily move the home while the new open foundation is constructed. Pile-driving technologies are available depending on site constraints, including low-head-room rigs or hammers, to elevate the home in place. These technologies are typically associated with micropiles When buildings are very close together, excavating to construct columns/piers with spread footings or grade beams could adversely affect neighboring buildings When buildings are very close together, lifting beams may not have required clearance for installation Basements must be filled in if NFIP compliance is required or desired Existing basement or crawl space walls must be analyzed to determine if additional reinforcement is required to resist design loads associated with elevating the building, as well as the loads of the design level event Utilities and their controls should be elevated above the BFE/ ABFE Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 11 of 14
12 foundations. Once all of this information has been evaluated, the design professional will be able to prepare cost estimates to determine which foundation design is the best value. Table 2 presents relative costs and a number of considerations associated with elevating homes on different foundation types. Table 2: Comparison of Relative Costs and Considerations Associated with Elevating Homes on Alternative Open Foundations in Tight, Narrow Lots Consideration Requires moving home off footprint Column/Pier Foundation Traditional Pile Foundation Micropile Foundation No Yes No Elevate-in-place Yes No Yes Impacts to neighboring properties Medium to High High Low Foundation $ $$$ $$ Cost Foundation connection $$ $ $$ Elevation $$ $$$ $$ Ease of installation Yes Maybe Yes Design basis IBC 1 /ASCE 24/FEMA P-55 2 IBC 1 /ASCE 24/FEMA P-55 2 IBC 1 /ASCE 24/ FEMA P-55 2 /FHWA NHI IBC, International Building Code 2 Coastal Construction Manual (2011) 3 Micropile Design and Construction Guidelines Manual (2005) Open Foundation and Elevation Design Process The design process for elevating homes on open foundations is shown in Figure 9. Pile design: Pile design requires some additional steps. Remove existing structure to allow access for pile-driving equipment Determine pile depth based on pile load and soil strata Determine pile spacing based on pile capacity, building loads, and span capacity of the building and grade beams Achieve lateral capacity by increasing the number of piles or by properly connecting batter piles/anchors to the piles and footings with a pile cap Design the new access to the building and utility extensions Micropile installation: Contractor qualifications should be specified prior to bidding elevation projects. Qualifications should include prior experience, bonding/insurance, licensure, and familiarity with local construction and soil types. To ensure the foundation is installed properly, micropile installation should be supervised by an experienced contractor who has recently completed similar projects in similar soils. Geotechnical conditions can vary greatly across one property and an experienced contractor will be able to make field decisions when obstructions, refusal, voids, soft soils, and other unanticipated subsurface conditions are encountered. To be successful, micropiles must be installed with an adequate embedment and must be able to resist the load capacity. Load testing of piles is recommended to verify design calculations and the adequacy Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 12 of 14
13 of a contractor s installation methods. Regardless of the resistance measured during installation or through load testing, the minimum embedment depth specified by the design professional must be satisfied for the pile to perform as designed. Useful Links and Resources Publications ASCE (American Society of Civil Engineers). ASCE 24, Flood Resistant Design and Construction. ASCE. ASCE 7, Minimum Design Loads for Buildings and Other Structures. FEMA (Federal Emergency Management Agency) FEMA NFIP Technical Bulletin 1, Openings in Foundation Walls and Walls of Enclosures. Available at gov/library/viewrecord.do?id=1579. FEMA FEMA NFIP Technical Bulletin 2, Flood Damage Resistant Materials Requirements. Available at FEMA FEMA NFIP Technical Bulletin 5, Free of Obstruction Requirements. Available at library/viewrecord.do?id=1718. FEMA FEMA NFIP Technical Bulletin 9, Design and Construction Guidance for Breakaway Walls. Available at FEMA Homeowner s Guide to Retrofitting. FEMA P-312. Available at do?id=1420. FEMA Hurricane Ike in Texas and Louisiana: Mitigation Assessment Team Report. Available at library/viewrecord.do?id=3577. FEMA Hurricane Ike Recovery Advisories. Available at Figure 9: 12-step design process for elevating homes. FEMA Recommended Residential Construction for Coastal Areas Building on Strong and Safe Foundations. FEMA P-550. Available at do?id=1853. FEMA Substantial Improvement / Substantial Damage Desk Reference. FEMA P-758. Available at gov/library/viewrecord.do?id=4160. FEMA Coastal Construction Manual. FEMA P-55. Available at omsearch=fromsearch&id=1671. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 13 of 14
14 FEMA Changes in the Flood Insurance Program: Preliminary Considerations for Rebuilding. Available at FEMA Comparison of Select NFIP and Building Code Requirements for Special Flood Hazard Areas. FEMA Quick Reference Guide. Available at FEMA Engineering Principles and Practices of Retrofitting Floodprone Residential Structures. FEMA P-259. Available at FEMA Flood Insurance Reform Act of 2012: Impact of changes to the NFIP. Available at library/viewrecord.do?id=7187. FEMA Hurricane Sandy Recovery Advisories and Fact Sheets Available from building-science/hurricane-sandy-building-science-activities-resources. Hurricane Sandy Recovery Advisory No. 1, Improving Connections in Elevated Coastal Residential Buildings Hurricane Sandy Recovery Advisory No. 3, Restoring Mechanical, Electrical and Plumbing Systems in Non- Substantially Damaged Residential Buildings Hurricane Sandy Recovery Advisory No. 5, Designing for Flood Levels Above the Base Flood Elevation. Hurricane Sandy Recovery Advisory No. 7, Reducing Flood Risk and Flood Insurance Premiums for Existing Buildings. FEMA Hurricane Sandy Mitigation Assessment Report. FHWA (Federal Highway Administration) Micropile Design and Construction Guidelines Manual, FHWA NHI ICC (International Code Council) International Building Code. Country Club Hills, IL. ICC International Residential Code for One- and Two-Family Dwellings. Country Club Hills, IL. Web Sites Deep Foundation Institute, asp International Association of Certified Home Inspectors, house raising, International Association of Structural Movers, Information on FEMA FIRMs, and www. floodsmart.gov Post-Hurricane Sandy ABFE maps for parts of New York and New Jersey, For more information, see the FEMA Building Science Frequently Asked Questions website at If you have any additional questions on FEMA Building Science Publications, contact the helpline at or You may also sign up for the FEMA Building Science subscription, which is updated with publication releases and FEMA Building Science activities. Subscribe at com/accounts/usdhsfema/subscriber/new?topic_ id=usdhsfema_193. Visit the Building Science Branch of the Risk Reduction Division at FEMA s Federal Insurance and Mitigation Administration at building-science. To order publications, contact the FEMA Distribution Center: Call: (Monday Friday, 8 a.m. 5 p.m., EST) Fax: [email protected] Additional FEMA documents can be found in the FEMA Library at Please scan this QR code to visit the FEMA Building Science web page. Hurricane Sandy Fact Sheet: Open Foundation Requirements for Elevated Homes FEMA-DRs-4085-NY and NJ / May 2013 page 14 of 14
Elevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
Table of Contents. Comments on the Technical Bulletins should be directed to:
Openings in Foundation Walls and Walls of Enclosures Below Elevated Buildings in Special Flood Hazard Areas in accordance with the National Flood Insurance Program Technical Bulletin 1 / August 2008 Table
Openings in Foundation Walls for Buildings Located in Special Flood Hazard Areas
Openings in Foundation Walls for Buildings Located in Special Flood Hazard Areas in accordance with the National Flood Insurance Program FEDERAL EMERGENCY MANAGEMENT AGENCY FEDERAL INSURANCE ADMINISTRATION
1. GENERAL ADVISORY BASE FLOOD ELEVATION (ABFE) QUESTIONS
INTRODUCTION As communities begin to recover from the devastating effects of Hurricane Sandy, it is important to recognize lessons learned and to employ mitigation actions that ensure structures are rebuilt
http://library1.municode.com/default/docview/10251/1/101/103
Page 1 of 8 ARTICLE II. FLOOD DAMAGE PREVENTION* *Cross references: Buildings and building regulations, ch. 67; floor elevation standards, 67-32; flood damage prevention for utility systems, 67-34; drainage
Updated Federal Emergency Management Agency Flood Insurance Rate Maps and Zoning Ordinance Update. July 16, 2015 Policy Committee
Updated Federal Emergency Management Agency Flood Insurance Rate Maps and Zoning Ordinance Update July 16, 2015 Policy Committee FEMA Map Update Costal Analysis and mapping study by FEMA in 2009 Changes
Summary of Coastal Construction Requirements and Recommendations
Summary of Coastal Construction Requirements and Recommendations HOME BUILDER S GUIDE TO COASTAL CONSTRUCTION FEMA 499/August 2005 Technical Fact Sheet No. 2 Purpose: To summarize National Flood Insurance
REBUILDING BELMAR ABFE FLOOD MAPS &THE REBUILDING PROCESS
REBUILDING BELMAR ABFE FLOOD MAPS &THE REBUILDING PROCESS REBUILDING BELMAR ABFE Maps Preliminary FIRM Maps Flood Insurance Increased Cost of Compliance (ICC) Elevation of Structures Building Permits Acronyms
780 CMR 120.G FLOOD-RESISTANT CONSTRUCTION AND CONSTRUCTION IN COASTAL DUNES Note that this Appendix is unique to Massachusetts
780 CMR 120.G FLOOD-RESISTANT CONSTRUCTION AND CONSTRUCTION IN COASTAL DUNES Note that this Appendix is unique to Massachusetts 120.G.101.1 General: All buildings and structures erected in areas prone
CHAPTER 3 page 69 LOCAL FLOODPLAIN REGULATIONS AND NFIP STANDARDS
CHAPTER 3 page 69 LOCAL FLOODPLAIN REGULATIONS AND NFIP STANDARDS LOCAL FLOODPLAIN REGULATIONS AND NFIP STANDARDS, page 69 THE PARTICIPATION OF A COMMUNITY IN THE NFIP IS MADE POSSIBLE BY ITS ADOPTION
Quick RefeRence Guide comparison of Select nfip and Building code Requirements for Special flood Hazard Areas
Quick RefeRence Guide comparison of Select nfip and Building code Requirements for Special flood Hazard Areas This guide illustrates the similarities and highlights the differences between the National
4.3.5 - Breakaway Walls
4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free
FLOOD DAMAGE PREVENTION ORDINANCE
FLOOD DAMAGE PREVENTION ORDINANCE SECTION 1.0 STATUTORY AUTHORIZATION, FINDINGS FO FACT, PURPOSE, AND OBJECTIVES 1.1 STATUTORY AUTHORIZATION The Legislature of the State of Washington has in RCW delegated
Above the Flood: Elevating Your Floodprone House. Federal Emergency Management Agency. Federal Emergency Management Agency
FEMA 347/May 2000 Above the Flood: Elevating Your Floodprone House Mitigation Directorate 500 C Street, SW Washington, DC 20472 www.fema.gov Table of Contents Chapter 1 Introduction... 1-1 Chapter 2 Homeowner
Above the Flood: Elevating Your Floodprone House. FEMA 347/ May 2000 FEMA
Above the Flood: Elevating Your Floodprone House FEMA 347/ May 2000 FEMA Cover photograph provided by The Weather Channel. Acknowledgments The support and contributions of the following individuals and
Reducing Flood Risk to Residential Buildings That Cannot Be Elevated
Reducing Flood Risk to Residential Buildings That Cannot Be Elevated FEMA P-1037 / September 2015 Elevated utility readable from standing height ~6.5' above grade Basement infill with gravel Approximate
EXISTING STRUCTURES 1) FAIR MARKET VALUE OF STRUCTURE(s) BEFORE IMPROVEMENT: 2) COST OF IMPROVEMENTS:
Date Received: Received By: Project/Permit Number: Fee: (To be Completed by MOA) FLOOD HAZARD PERMIT APPLICATION (Please fill out application completely; Indicate NA if necessary. Property information
Substantial Improvement/Substantial Damage for Floodplain Administrators Mitigation Fact Sheet
Substantial Improvement/Substantial Damage for Floodplain Administrators Mitigation Fact Sheet Substantial Improvement/Substantial Damage are everyday issues, not just post-disaster; and they apply to
SECTION 19 RESIDENTIAL CONSTRUCTION IN FLOODZONES
SECTION 19 RESIDENTIAL CONSTRUCTION IN FLOODZONES The purpose of the following information and documents are to clarify procedures used by the Sonoma County Permit & Resource Management Department to enforce
LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION
LOWEST FLOOR GUIDE This section is to be used as a guide for identifying the lowest floor for rating buildings being considered for coverage under the National Flood Insurance Program (NFIP). I. LOWEST
Frequently-Asked Questions about Floodplains and Flood Insurance FLOOD INSURANCE
Frequently-Asked Questions about Floodplains and Flood Insurance What is a floodplain? The floodplain is any area covered by water during normal water flows, and which could be inundated as a result of
Free-of-Obstruction Requirements
Free-of-Obstruction Requirements for Buildings Located in Coastal High Hazard Areas in accordance with the National Flood Insurance Program Technical Bulletin 5 /August 2008 Table of Contents Introduction...1
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
SECTION 15 FLOODPLAIN MANAGEMENT
SECTION 15 15.1 Purpose Certain areas of the City of Gardiner, Maine, are subject to periodic flooding, causing serious damages to properties within these areas. Relief is available in the form of flood
Presenters. The Ups and Downs of Home Elevations 4/29/2016. Hazard Mitigation Grant (HMA) Programs
The Ups and Downs of Home Elevations Presenters Kathy C. Hopkins, Texas Water Development Board Jeff Ward, Jeffrey, Ward and Associates Jamie Galloway, City of Nassau Bay 2 Hazard Mitigation Grant (HMA)
Control filling, grading, dredging, and other development which may increase erosion or flood damage; and
ARTICLE 16. FLOOD DAMAGE PREVENTION Section 16-1: Findings of Fact The flood hazard areas of the Town of Lillington are subject to periodic inundation which results in loss of life and property, health
Elevator Installation for Buildings Located in Special Flood Hazard Areas in accordance with the National Flood Insurance Program
Elevator Installation for Buildings Located in Special Flood Hazard Areas in accordance with the National Flood Insurance Program FEDERAL EMERGENCY MANAGEMENT AGENCY FEDERAL INSURANCE ADMINISTRATION FIA-TB-4
New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations
from New construction foundations don t have to be a headache. The CHANCE Helical Pier Foundation System gives you the performance of concrete without the drawbacks and liabilities of driven piles and
Status of Building Codes in New Jersey and New York: The Future of Resilience in a Post-Sandy Environment
Status of Building Codes in New Jersey and New York: The Future of Resilience in a Post-Sandy Environment Sandy devastated properties in several states, but primarily in New York and New Jersey. Now, as
STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
Elevation Certificates. Brad Loar FEMA Region IV
Elevation Certificates Brad Loar FEMA Region IV What is the purpose of the Elevation Certificate? The Elevation Certificate is an important administrative tool of the National Flood Insurance Program (NFIP).
Repairs, Remodeling, Additions, and Retrofitting
Repairs, Remodeling, Additions, and Retrofitting HOME BUILDER S GUIDE TO COASTAL CONSTRUCTION FEMA 499/August 2005 Technical Fact Sheet No. 30 Purpose: To outline National Flood Insurance Program (NFIP)
PRELIMINARY DIGITAL FLOOD INSURANCE RATE MAPS (DFIRM)
INTRODUCTION This Mississippi Guidance document has been prepared to explain to community officials how the Preliminary Digital Flood Insurance Rate Maps (DFIRMs) and Preliminary Flood Insurance Study
LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
D Sample Notices to Property Owners, Sample Affidavits, and Other Material
D Sample Notices to Property Owners, Sample Affidavits, and Other Material These samples are offered to illustrate specific points in the Desk Reference. States and communities should examine them carefully
FOUNDATION TECHNICAL CATEGORY 3 (TC3) AUGUST 2012
FOUNDATION TECHNICAL CATEGORY 3 (TC3) AUGUST 2012 Building and Housing has published technical guidance for foundation repairs and reconstruction for residential properties in green zone Foundation Technical
Kentucky Model Flood Damage Prevention Ordinance. 2015 KAMM Annual Conference Carey Johnson Kentucky Division of Water
Kentucky Model Flood Damage Prevention Ordinance 2015 KAMM Annual Conference Carey Johnson Kentucky Division of Water Flood Damage Prevention Ordinance Also referred to as Floodplain Management Ordinance
Substantial Improvement/ Substantial Damage Desk Reference. FEMA P-758 / May 2010 FEMA
Substantial Improvement/ Substantial Damage Desk Reference FEMA P-758 / May 2010 FEMA Substantial Improvement/ Substantial Damage Desk Reference FEMA P-758 / May 2010 Preface When buildings undergo repair
ORDINANCE NO. 2003-09
ORDINANCE NO. 2003-09 AN ORDINANCE AMENDING THE HERNANDO COUNTY CODE OF ORDINANCES CHAPTER 13. FLOOD DAMAGE PREVENTION AND PROTECTION; BY PROVIDING FOR AUTHORITY; BY AMENDING ARTICLE I, SECTION 13-5, DEFINITIONS,
National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination
Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)
ARTICLE 12 FLOOD DAMAGE PREVENTION
ARTICLE 12 FLOOD DAMAGE PREVENTION SECTION 12.1 AUTHORIZATION 12.1.1 General The Legislature of the State of North Carolina has in Part 6, Article 21 of Chapter 143; Parts 3 and 4 of Article 18 of Chapter
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION. Previous Section Table of Contents
Previous Section Table of Contents Next Section This section is to be used as a guide for identifying the lowest floor for rating buildings being considered for coverage under the National Flood Insurance
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
Elevations Certificates: Update 2009 Presented by Wendy Lathrop, PLS, CFM
Elevations Certificates: Update 2009 Presented by Wendy Lathrop, PLS, CFM The objectives of the National Flood Insurance Program (NFIP): Reduce the exposure to flood damages through the use of minimum
Agenda. Presenter. The Current Form. Adobe Fillable Form. Elevation Certificates FEMA Form 81-31. Elevation Certificates Training 11/14/2013
NORFMA Floodplain Conference November 14, 2013 Boise, Idaho Agenda Introductions & Housekeeping Overview Basics of FEMA Form 81-31 Building Diagrams Exercise Common Errors Using ECs in Floodplain Development
LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION
This section is to be used as a guide for identifying the lowest floor for rating buildings being considered for coverage under the National Flood Insurance Program. I. LOWEST FLOOR DETERMINATION The following
10-01. Technical Bulletin
Technical Bulletin 10-01 Ensuring That Structures Built on Fill In or Near Special Flood Hazard Areas Are Reasonably Safe From Flooding in accordance with the National Flood Insurance Program FEDERAL EMERGENCY
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Jeff R. Hill, P.E. Hayward Baker Inc. 111 W. Port Plaza Drive Suite 600 St. Louis, MO 63146 314-542-3040 [email protected]
Flood Damage Prevention
City of Talent Flood Damage Prevention General Ordinances, Title 8, Chapter 5 Adopted by Ordinance No. 752 on 4 February 2004 SECTION 1.0: STATUTORY AUTHORIZATION, FINDINGS OF FACT, PURPOSE, AND OBJECTIVES
Protecting Building Utilities FromFloodDamage PrinciplesandPracticesfor thedesign andconstruction of FloodResistant BuildingUtilitySystems
First Edition FEMA348 HVAC Protecting Building Utilities FromFloodDamage PrinciplesandPracticesfor thedesign andconstruction of FloodResistant BuildingUtilitySystems FUEL ELECTRICAL SEWAGE WATER FEDERALEMERGENCYMANAGEMENT
Sample Flood Damage Prevention Ordinance
Sample Flood Damage Prevention Ordinance COUNTY OF RABUN STATE OF GEORGIA ORDINANCE AN ORDINANCE ADOPTING FLOOD DAMAGE PREVENTION REGULATIONS OF THE CITY OF CLAYTON, GEORGIA WHEREAS; The Mayor and City
LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION
Previous Section Main Menu Table of Contents Next Section This section is to be used as a guide for identifying the lowest floor for rating buildings being considered for coverage under the National Flood
Appeal means a request for a review of the county's interpretation of any provision of this article or a request for a variance.
ARTICLE XI. FLOOD DAMAGE PREVENTION* *Cross references: Waterways, ch. 78. DIVISION 1. GENERALLY Sec. 42-966. Definitions. The following words, terms and phrases, when used in this article, shall have
Administrative Procedures Regarding the Application of Flood Damage Prevention
Administrative Procedures Regarding the Application of Flood Damage Prevention A floodplain development permit, conforming to the provisions of the Flood Damage Prevention Ordinance ( the Ordinance, shall
SECTION 1.0 STATUTORY AUTHORIZATION AND PURPOSE
A local law for Flood Damage Prevention as authorized by the New York State Constitution, Article IX, Section 2, and Environmental Conservation Law, Article 36 1.1 FINDINGS SECTION 1.0 STATUTORY AUTHORIZATION
DEPARTMENT OF PLANNING AND DEVELOPMENT
DEPARTMENT OF PLANNING AND DEVELOPMENT FLOODPLAIN DEVELOPMENT PERMIT APPLICATION FOR NON-RESIDENTIAL DEVELOPMENT Property Owner Telephone Street/P.O. Box City State ZIP Agent (if any) Relationship to Property
CASS COUNTY COMMISSION POLICY MANUAL 38.07 ADOPTED DATE: FEBRUARY 2, 1998 PAGE 1 OF 9
CASS COUNTY COMMISSION POLICY MANUAL 38.07 SUBJECT: ORDINANCE #1998-2 (FLOOD DAMAGE PREVENTION) ADOPTED DATE: FEBRUARY 2, 1998 PAGE 1 OF 9 NORTH DAKOTA COUNTY OF CASS ORDINANCE #1998-2 Be it ordained and
Kanawha County Floodplain Regulations Quick Guide & Overview
Kanawha County Floodplain Regulations Quick Guide & Overview CHUCK GRISHABER, CFM KANAWHA COUNTY FLOOD PLAIN MANAGER Office: 304.357.0570 Mobile: 304-356.0979 Fax: 304.357.0572 [email protected]
FLOOD DAMAGE PREVENTION ORDINANCE CITY OF NEW HAVEN, CONNECTICUT
FLOOD DAMAGE PREVENTION ORDINANCE CITY OF NEW HAVEN, CONNECTICUT SECTION 1 - STATUTORY AUTHORIZATION, FINDING OF FACT, PURPOSE AND OBJECTIVES 1.1 Statutory Authorization In Section 7-148(c)(7) of the General
CHAPTER XXII FLOOD DAMAGE PREVENTION
CHAPTER XXII FLOOD DAMAGE PREVENTION 22-1 PURPOSE AND POLICY. It is hereby found that the flood hazard areas of the Township are subject to periodic inundation which results in loss of life, property,
Florida Division of Emergency Management
FLOODPLAIN MANAGEMENT IN FLORIDA 2012 Florida Division of Emergency Management Bureau of Mitigation State Floodplain Management Office 2555 Shumard Oak Boulevard, Tallahassee, FL 32399 www.floridadisaster.org
Chapter 9 FLOOD DAMAGE PREVENTION AND CONTROL* ARTICLE I. IN GENERAL
Chapter 9 FLOOD DAMAGE PREVENTION AND CONTROL* Art. I. In General, 9-1--9-25 Art. II. Administration, 9-26--9-55 Div. 1. Generally, 9-26--9-40 Div. 2. Development Permit, 9-41--9-55 Art. III. Provisions
A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.
A Solid Foundation Solution for Homeowners from Our products are made with 90% Recycled Material Down. Right. Solid. GREEN. Stop the damaging effects of foundation settling... Sinking foundations, cracked
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM
Shepherd University Board of Governors June 9, 2005 Agenda Item No. 9 SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM In 1994 construction began on the Byrd Science and
Ordinance No. The Flood Damage Prevention Ordinance of the Borough of Mantoloking
Ordinance No. The Flood Damage Prevention Ordinance of the Borough of Mantoloking TABLE OF CONTENTS Article I STATUTORY AUTHORIZATION, FINDINGS OF FACT, PURPOSE AND OBJECTIVES Section 1.1 Statutory Authorization
rescue and relief efforts in the aftermath of flooding, (iii) repair of flood damaged public facilities and utilities, and
1. Purpose (1) It is the purpose of this Ordinance to protect human life, health, and property from flood conditions, to preserve the ability of floodplains to carry and discharge a base flood, and to
NY Rising Housing Recovery Program
NY Rising Housing Recovery Program Home Elevation Design Guidance 12/11/2014 The following provides construction related information to a Homeowner and/or Design Professional for designing and elevating
How To Manage A Flood
Chapter 15.36 FLOOD DAMAGE PREVENTION* Sections: ARTICLE I. STATUTORY AUTHORIZATION, FINDINGS OF FACT, PURPOSE AND METHODS 15.36.010 Statutory authorization. 15.36.020 Findings of fact. 15.36.030 Statement
SPECIFIC RATING GUIDELINES
NATIONAL FLOOD INSURANCE PROGRAM SPECIFIC RATING GUIDELINES April 2015 FEDERAL EMERGENCY MANAGEMENT AGENCY FEDERAL INSURANCE AND MITIGATION ADMINISTRATION RISK INSURANCE DIVISION UNDERWRITING BRANCH This
9.0 Protecting Service Equipment
9.0 Protecting Service Equipment Homes are typically provided with a variety of building support service equipment. Five major services make up the mechanical, electrical, and plumbing (MEP) systems found
BALDWIN COUNTY FLOOD DAMAGE PREVENTION ORDINANCE
BALDWIN COUNTY FLOOD DAMAGE PREVENTION ORDINANCE BALDWIN COUNTY COMMISSION 1 P a g e FLOOD DAMAGE PREVENTION ORDINANCE OF BALDWIN COUNTY, ALABAMA Adopted by the Baldwin County Commission: January 3, 1978
NATIONAL FLOOD INSURANCE PROGRAM COMMUNITY FLOODPLAIN MANAGEMENT REGULATIONS REVIEW CHECKLIST
COMMUNIT FLOODPLAIN MANAGEMENT REGULATIONS Community:_Montpelier_ C.I.D. _505518_ State_Vermont_ Ned Swanberg, VT DEC 241.4596 [email protected] 10/5/10 Review of: Montpelier Zoning Regs (Flood)
Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations
Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations Nathan A. Ingraffea, P.E., S.E. Associate, KPFF Consulting Engineers, Portland, Oregon, USA Abstract The use of steel sheet
USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch
USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and
FLOOD DAMAGE PREVENTION ORDINANCE CITY OF NEW HAVEN, CONNECTICUT
FLOOD DAMAGE PREVENTION ORDINANCE CITY OF NEW HAVEN, CONNECTICUT SECTION 1 - STATUTORY AUTHORIZATION, FINDING OF FACT, PURPOSE AND OBJECTIVES 1.1 Statutory Authorization In Section 7-148(c)(7) of the General
PREVENTION. City of Orem FLOOD DAMAGE PREVENTION 10-1-1
City of Orem FLOOD DAMAGE PREVENTION 10-1-1 CHAPTER 10. Article 10-1. Article 10-2. Article 10-3. Article 10-4. Article 10-5. FLOOD DAMAGE PREVENTION Purposes Definitions General Provisions Administration
FLOODPLAIN MANAGEMENT IN SOUTH CAROLINA. Quick Guide. South Carolina Department of Natural Resources Flood Mitigation Programs http://www.dnr.sc.
FLOODPLAIN MANAGEMENT IN SOUTH CAROLINA 2008 Quick Guide South Carolina Department of Natural Resources Flood Mitigation Programs http://www.dnr.sc.gov Table of Contents 1... About This Guide 2... Introduction
BE IT ORDAINED by the Borough Council of the Borough of Little Silver, County of. Chapter XXII, Flood Damage Prevention
736-13 ORDINANCE AMENDING CHAPTER XXII (FLOOD DAMAGE PREVENTION) OF THE REVISED GENERAL ORDINANCES OF THE BOROUGH OF LITTLE SILVER, COUNTY OF MONMOUTH AND STATE OF NEW JERSEY (1973) BE IT ORDAINED by the