INTRODUCTION. Intro-1. Copyright 2003 Hubbell, Inc. Helical Screw Foundation System Design Manual for New Construction A.B.
|
|
|
- Penelope Ball
- 10 years ago
- Views:
Transcription
1 INTRODUCTION Definition: Helical Screw Foundation The helical screw foundation can be devised into a deep foundation system to support or resist any load or application. Installed by lightweight mobile equipment, it can be loaded immediately. The helical screw foundation s elegant simplicity is its greatest asset. Its mechanical design and manufacture balance the capacities of its three basic parts and maximize the efficient use of their material. Essential Elements 1. At least one bearing plate Matching dies form each steel bearing plate into a true helix. This is to minimize soil disturbance during installation (as opposed to the inclined plane of an auger which mixes soil as it excavates). Properly formed helical plates do not measurably disturb the soil. On the lower end of an installed screw foundation, the helical bearing plates transfer the load to the bearing stratum deep below the ground surface. Deep is defined by as five helix diameters vertically below the surface where the helical plate can develop full capacity of the plate-to-soil interaction. 2. A central shaft During installation, the central steel shaft transmits torque to the helical plate(s). Once in place, the shaft transfers the axial load to the helical plate(s) and on to the bearing stratum. Theoretically, the shaft needs to be only large enough for stress in the shaft to remain below the shaft material s allowable stress level. Realistically, the shaft also needs to be strong enough to resist the torque required for installation and large enough in section for the soil to resist buckling. 3. A termination The termination connects the structure to the top of the helical screw foundation and transfers the load down the shaft to the helical plate(s) and on to the bearing soil. To evenly distribute the structure load to the helical screw foundations, the termination may be a manufactured bracket or an attachment produced on site as prescribed by the structural designer. Such aspects dictate the termination s configuration as a function of its application and may range from a simple threaded bar to a complex weldment, as is appropriate to interface with the structure. Intro-1
2 History and Science of Helical Screw Foundations In 1833, the helical screw foundation was patented as the screw pile by English inventor Alexander Mitchell. Soon after, he installed screw piles to support lighthouses in tidal basins of England. The concept also was used for lighthouses off the coasts of Maryland, Delaware and Florida. One is still in use offshore at Key Biscayne, FL. From this practical worthy start, innovations of the helical screw foundation have been promulgated by both its academic and commercial advocates. Notable university and industry proponents on record who have expanded the science of earth anchors and foundations include: J.I. Adams, Ontario Hydro; S.P. Clemence, Syracuse University; T.H. Hanna, University of Sheffield; J. A. Howie, University of British Columbia; A.J. Luetenegger, University of Massachusetts; T.E. Rodgers, Virginia Power; and Bill Summerfield, SWEPCO. Today, relatively small and readily available construction equipment can install helical screw foundations almost anywhere. Backhoes, skid-steer loaders and mini-excavators are easily fitted with the necessary hydraulically driven torque motors to place helical screw foundations in construction sites inaccessible by the larger equipment required for other methods. According to site conditions, installation equipment also can include guided-head and articulated-head torque-head machinery, self-propelled, carrier-mounted, tracked, wheeled or floating. Chief Contributor: The following summarizes a short list of A.B. Chance Co. contributions to the helical screw anchor/foundation. The first commercially offered screw anchor was sold by the Chance Co. in For tension applications, it was installed by hand using a small tubular wrench. Other early developments include soil classifying measurement devices. PISA (Power Installed Screw Anchors) In the late 1950 s, the Chance Co. introduced the patented PISA system. This coincided with the advent of truck-mounted hole-digging equipment following World War II. The PISA system since has become the worldwide method of choice for guying pole lines of electric and telephone utilities. The PISA system s all-steel components include one or two helix plates welded to a square hub, a rod threaded on both ends, a forged guy wire eye nut, and a special installing wrench. The square-tube anchor wrench attaches to the Kelly bar of a digger truck, fits over the rod, engages the helical hub and typically installs a PISA anchor in eight to 10 minutes. Rod and wrench extensions may be added to reach soil layers which develop enough resistance to achieve competent anchorage. PISA rods come in 5 / 8, 3 / 4 and 1 diameters. Through Chance Co. testing and close contact with utilities, the PISA anchor family soon expanded to develop higher strengths capable of penetrating harder soils including glacial till. This quickly gave rise to the Company s development of screw anchors with higher capacities and larger dimensions. More recent developments include the SQUARE ONE (1980) and the TOUGH ONE (1989) patented guy anchor families with 10,000 and 15,000 ft-lb installing torque capacities. Unlike previous PISA designs, these anchor designs are driven by a wrench that engages inside, rather than over, their welded socket hubs. Both use the PISA extension rods with threaded couplings. Intro-2
3 RR (Round Rod) Anchors In 1961, Chance developed extendable Type RR multi-helix anchors, originally for use as tiedowns for underground pipelines in poor soil conditions on the Gulf of Mexico coast. These anchors are not driven by a wrench; instead, installing torque is applied directly to their 1 1 / 4 " diameter shafts. Type RR anchors worked well in weak surficial soils, but their shaft (although extendable by plain shafts with bolted upset couplings) did not provide enough torque strength to penetrate very far into firm bearing soils. SS (Square Shaft) Anchors Development of a high-torque, shaft-driven, multi-helix anchor began in 1963, culminating in the Chance Company s introduction of Type SS 1 1 / 2 " Square-Shaft multi-helix anchors in The SS anchor family since has expanded to include higher-strength 1 3 / 4 ", 2" and 2 1 / 4 " square shafts. Extension shafts with upset sockets also lengthen these anchors to penetrate most soils at significant depths for many civil construction applications including guying, foundations, tiebacks and, more recently, soil nails (Chance SOIL SCREW Retention Wall System, 1997). HS (High-Strength) Anchors Later in the 1960 s, Type HS anchors developed first for high-torque guying requirements later were applied as foundation anchors for utility substations and transmission towers. The HS anchor family has 3 1 / 2 " pipe shafts which may be lengthened by extensions with swaged couplings. HS anchors now are used for a wide array of foundation applications. PIF (Power Installed Foundation) Anchors Also launched in this timeframe were non-extendable anchors termed Power Installed Foundations. PIF sizes and load capacities match support requirements for a broad range of equipment, platforms and field enclosures. Most versatile are the 5-ft to 10-ft-long PIF with pipe shafts of 3 1 / 2 ", 4", 6 5 / 8 ", 8 5 / 8 " and 10 3 / 4 " diameters, each with a single helix of 10", 12", 14" or 16" diameter. Integral baseplates permit direct bolt-up connections on either fixed or variable bolt-circle patterns. Bumper Post anchors are similar to the 3 1 / 2 "-shaft PIF, but with fence-type caps instead of baseplates, to serve as traffic barriers around booths, cabinets, doorways, etc. One with a 2 3 / 8 " pipe shaft 69" long is called a Square-Drive Foundation for its 2"-square drive head. The solid head is internally threaded for adding a straight stud or adjustable leveling pad after installation. A smaller non-extendable 35"-long version with a 3 / 4 " solid shaft, driven by such hand tools as a deep socket and ratchet wrench, also accepts the straight stud or leveling pad. Pad-Pod Foundation Anchors Originally conceived for supporting padmounted underground electrical distribution transformers, Pad-Pod Foundation Anchors, are flange-driven with 2"-diameter extendable pipe shafts, each with an 8" or 10" helix. SLF (Street Light Foundation) Anchors 1972 introduced SLF (Street Light Foundation) anchors with pipe shaft diameters of 6 5 / 8 ", 8 5 / 8 " and 10 3 / 4 " in fixed lengths of 5, 8 and 10 feet. Complete with an internal cableway, these foundations with bolt-up baseplates deliver the quick solution their name implies and now are used to support similar loads for a variety of applications. T/C (Tension/Compression) Foundation Anchors Especially designed for utility transmission tower foundations and known as T/C anchors Intro-3
4 for their resistance to such uplift-tension, compression, bending and lateral loads, these 8" pipe shaft anchors may be extended by a unique bolted coupling of their helical plates. HELICAL PIER Foundation Systems In 1985, Chance introduced this patented remedial method for repairing foundations of residential and commercial buildings. Originally based on Type SS helical screw foundation anchors, its special foundation repair brackets transfer structural loads to stable soil strata below weak surface conditions. Since then, the method also has been used to deepen foundations for new construction by installing the helical screw foundations at intervals between footing forms prior to pouring reinforced concrete. HELICAL PULLDOWN Micropiles Developed in 1997, for sites with especially weak surface soils, this Chance patented innovative application of the helical screw foundation integrates Portland-cement-based grout to stiffen its upper shaft. By pulling down a special flowable grout as the foundation is screwed into the soil, the result is a pile with both a friction-bearing central shaft and end-bearing helical plates in competent substrata. Where needed for poor surface conditions, this performance combination converts impossible sites to sound, for not only building construction but also telecom tower foundations in areas inaccessible by equipment for other methods. It employs SS, HS and combinations of these two types of helical screw foundations. Applied Research and Development: In addition to products developed for specific applications, Chance contributions to applied science of helical screw anchors and foundation have been outstanding. Among subjects expanding the body of knowledge are these noteworthy milestones: A.B. Chance Co. Soil Classification Chart In 1945, the Chance Company s first earth anchoring manual classified soils according to holding capacities as related to proper anchor selection. At sites where soil data was available, either by sample excavation or some rudimentary means of probing subsurface strata, this chart imparted a valuable basis for recommending the proper helical screw anchor or foundation for a given load. The chart, as refined over the years and produced here, still serves as a useful reference today. Soil Classification Data Class **7 **8 Intro-4 Common Soil-Type Description Sound hard rock, unweathered Very dense and/or cemented sands; coarse gravel and cobbles Dense fine sands; very hard silts and clays (may be preloaded) Dense sands and gravel; hard silts and clays Medium dense sand and gravel; very stiff to hard silts and clays Medium dense coarse sands and sandy gravels; stiff to very stiff silts and clays Loose to medium dense fine to coarse sands to stiff clays and silts Loose fine sands; Alluvium; loess; medium - stiff and varied clays; fill Peat, organic silts; inundated silts, fly ash very loose sands, very soft to soft clays Geological Soil Classification Granite, Basalt, Massive Limestone Caliche, (Nitrate-bearing gravel/rock), Basal till; boulder clay; caliche; weathered laminated rock Glacial till; weathered shales, schist, gneiss and siltstone Glacial till; hardpan; marls Saprolites, residual soils Dense hydraulic fill; compacted fill; residual soils Flood plain soils; lake clays; adobe; gumbo, fill Miscellaneous fill, swamp marsh Probe Values in.-lbs. (NM) N.A (85-181) (68-85) (45-56) (34-45) (23-34) (11-23) less than 100 (0-11) Typical Blow Count "N" per ASTM-D1586 N.A Class 1 soils are difficult to probe consistently and the ASTM blow count may be of questionable value. **It is advisable to install anchors deep enough, by the use of extensions, to penetrate a Class 5 ot 6, underlying the Class 7 or 8 Soils
5 Torque-to-Capacity Relationships Installation torque-to-load capacity relationship is an empirical method originally developed by. Chance has long promoted the idea that the installation energy (torque) required to install a helical screw foundation can be correlated to its ultimate load capacity in soil. The analogy is similar to screwing a wood screw into a piece of wood. It takes more torsional energy to screw into dense wood, such as oak, than it does to screw into a soft wood, such as pine. Likewise, a wood screw in oak will require more effort to pull out than the same wood screw in pine. The same is true for helical screw foundations in soil. Dense soil requires more torque to install compared to a soft soil; and dense soil will generate more load capacity compared to a soft soil. This relationship is discussed in detail in Step 9. For the torque correlation method to work, torque must be measured. Chance Engineers have developed both mechanical and electronic indicators over the years, many of which are commercially available for torque measurement in the field. Soil mechanics principles In the 1970s and early 1980s, changes in design philosophy led engineers to recognize that a deep buried plate (i.e., screw anchor helix) transferred load to the soil in end-bearing. Theoretical capacity could then be calculated based on Terzaghi s general bearing capacity equation. The individual bearing method, discussed in detail in Step 4, calculates the unit bearing capacity of the soil and multiplies it by the projected area of the helix plate. The capacity of individual helix plate(s) is then summed to obtain the total ultimate capacity of a helical screw foundation. Today, the individual bearing method is commonly used in theoretical capacity calculations. 90+ years of field test data has a long standing tradition of proving theory in the field by conducting literally thousands of load tests. It has been said that soil occurs in infinite variety whose engineering properties can vary widely from place to place. This variability makes in-situ testing a vital part of sound geotechnical engineering judgment. Test results are available from Chance for typical capacity of helical screw foundations in soil. Refer to Step 11 for more information about load testing. HeliCAP Engineering Software Developed by Chance engineers, HeliCAP Engineering Software was designed to assist the designer select the correct helical lead configuration and overall screw foundation length. It also estimates the installation torque. This program, exclusive in the industry, makes the selection of helical screw foundations easier and quicker than any other method. The Appendix contains an application form for HeliCAP Engineering Software. To obtain a copy of the software, fill out the application form and contact your local A.B. Chance Company Civil Construction Distributor. Contact information for each distributor in the network can be found at Inter-helix spacing Load transfer either above or below the helix plate results in a stress zone within a defined soil volume. For individual bearing to work properly, the helix plates must be spaced far enough apart to avoid overlapping their stress zones. The key is to space the helix plates just far enough apart to maximize the bearing capacity of a given soil. This works to reduce the overall length of the screw foundation and increases the likelihood for all helix plates to be located in the same soil layer; which in turn leads to more predictable torque-to-capacity relationships and better load/deflection characteristics. Through years of research, determined that the optimal spacing for helix plates is Intro-5
6 three diameters. More specifically, the optimum space between any two helical plates on a helical screw foundation is three times the diameter of the lower helix. Today, all A.B. Chance helical screw foundations are manufactured using the industry standard of threediameters spacing. Industry Standard: Helical screw foundation form fits function The helical screw foundation is not a sophisticated product, but it continues to serve everexpanding roles in civil construction applications. However, you will not likely find helical screw foundations mentioned in foundation engineering textbooks, at least not as of the publication of the first edition of this design manual. Nor will you find helical screw foundations mentioned in the pile foundation, or pier foundation sections of model building codes. As a result, education about helical screw foundations and anchors is lacking which is one reason for the development of this manual. However, is the only manufacturer of helical screw foundations and anchors to obtain evaluation reports from all three model building code agencies ICBO, BOCA, and SBCCI. Copies of all three evaluation reports are in the Appendix. Applications In its simplest form, the screw foundation is a deep foundation element, i.e., it transfers structure dead and live loads to competent soil strata deep below grade. This is the same for any deep foundation element such as driven piles, drilled shafts, grouted tendons, auger-cast piles, belled piers, etc. Therefore, helicals can be used as a replacement for alternative methods such as drilled shafts and driven piles. Practical constraints primarily related to installation currently limit the maximum design load to 200 kip in compression and 100 kip in tension, which means helical screw foundations can resist relatively light to medium loads, not heavy loads. But as is the case with virtually all engineering problems, more than one solution exists. It is the responsibility of the engineer to evaluate all possible alternatives, and to select the most cost-effective solution. Today, helical screw foundations are commonly used for residential and light commercial construction, machinery/equipment foundations, telecommunication and transmission towers, tiedowns for wind and/or seismic forces, and virtually any application where site access is limited or remote. They have become the foundation of choice for walkways and boardwalks in environmentally sensitive areas, such as wetlands and protected forestland. In expansive soil areas, screw foundations can save money and time when compared to expensive over-excavation and fill options. Helical screw foundations do have several advantages (see following section) that make them the foundation of choice for many applications including these general categories: Machinery/equipment foundations Wind and seismic loading Limited access sites Replacement for drilled/driven piles Intro-6
7 Advantages of Helical Screw Foundations Each project has unique factors that determine the most acceptable foundation system. The following summarizes situations where helical screw foundations present sensible solutions. Projects requiring deep foundations due to weak surface soil Helical screw foundations are designed as end-bearing piles which transfer loads to competent, load-bearing strata. Advantages over other deep foundation systems: Eliminates high-mobilization costs associated with driven piles, drilled shafts or augercast piles. Helical screw foundations don t require spoils to be removed and for flowable sands, soft clays and organic soils, no casings are required, unlike drilled shafts or caissons. Flooded and/or poor surface conditions When surface conditions make spread footings impossible and equipment mobilization difficult, helical screw foundations are a good alternative since installation requires only a mini-excavator, a rubber-tired backhoe or small tracked machine. Limited access In confined areas with low overhead, helical screw foundations can be installed with portable equipment. This is particularly useful for rehabilitation work. Expansive soils The depth of expansive soils from the surface varies, but a typical depth is approximtely 10 feet. The bearing plates of a helical screw foundation are usually placed well below this depth. This means that only the small-cross-section shaft of the helical screw foundation is affected by the expansive soils. The swell force on the shaft is directly proportional to the surface area between the soil and the shaft, and the swell adheasion value. Since helical screw foundations have much smaller shafts than driven piles or auger-cast piles, uplift forces on screw anchors are much smaller. Research by R.L. Hargrave and R.E. Thorsten (1993, Dallas area) demonstrated helical screw foundations effectiveness in expansive soils. Bad weather installation Because helical screw foundations can be installed in any weather, work does not need to be interrupted. Contaminated soils Helical screw foundations are ideal for contaminated soils because no spoils need to be removed. Temporary structures Helical screw foundations can easily be removed by reversing the installation process. This makes removal of temporary structures simple. Remedial applications Helical screw foundations can supplement or replace existing foundations distressed from differential settlement, cracking, heaving, or general foundation failure. Patented systems such as Chance Helical Pier Foundation Systems provide a complete solution. Chance uses a patented system to attach the helical screw foundation to existing foundations and either stabilize the structure against further settlement or lift it back to near original condition. This system is only installed by trained and authorized certified contractors. Helical screw foundations are ideal for remedial work since they can be installed by portable equipment in confined, interior spaces. Additionally, there is no need to worry Intro-7
8 about heavy equipment near existing foundations. And, unlike driven piles, helical screw foundations are vibration-free. The building can continue to operate with little inconvenience to its occupants. Other deep foundation systems such as auger-cast piles disturb the soil, there`by undermining existing foundations. Helical screw foundations do not disturb existing conditions. Summary of Helical Screw Foundation Advantages No need for concrete to cure Install in any weather Quick, easy turnkey installation Immediate loading Small installation equipment Pre-engineered system Easily field modified Torque-to-capacity relationship for production control Solution for: -Restricted access sites -High water table -Weak surface soils Environmentally friendly No vibration No spoils to remove Intro-8
New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations
from New construction foundations don t have to be a headache. The CHANCE Helical Pier Foundation System gives you the performance of concrete without the drawbacks and liabilities of driven piles and
ATLAS RESISTANCE Pier Foundation Systems
ATLAS RESISTANCE Pier Foundation Systems Foundation Repair Systems for Civil Construction Applications: Residential, Commercial, Industrial Atlas Resistance Piers have been used to restore and/or stabilize
System. Stability. Security. Integrity. 150 Helical Anchor
Model 150 HELICAL ANCHOR System PN #MBHAT Stability. Security. Integrity. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair
Stability. Security. Integrity.
Stability. Security. Integrity. PN #MBHPT Foundation Supportworks provides quality helical pile systems for both new construction and retrofit applications. 288 Helical Pile System About Foundation Supportworks
Transmission Foundations. helical piles and guy anchors for transmission structures. www.hubbellpowersystems.com
Transmission Foundations helical piles and guy anchors for transmission structures www.hubbellpowersystems.com Grid locked on your transmission job? Instant Foundation helical piles go places concrete
The Stabilizer TM. Benefits. www.griptite.com. Supplemental support system for sagging beams and floor joists within a crawl space
The Stabilizer TM Supplemental support system for sagging beams and floor joists within a crawl space Pre-drilled holes in steel plate allow for connection to beam or floor joists. Benefits Levels and
A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.
A Solid Foundation Solution for Homeowners from Our products are made with 90% Recycled Material Down. Right. Solid. GREEN. Stop the damaging effects of foundation settling... Sinking foundations, cracked
Comprehensive Design Example 2: Foundations for Bulk Storage Facility
Comprehensive Design Example 2: Foundations for Bulk Storage Facility Problem The project consists of building several dry product storage silos near an existing rail siding in an open field presently
Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.
TM TM Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. SM The Leading Edge. 10 One Major Causes of foundation settlement or more conditions may
How to Design Helical Piles per the 2009 International Building Code
ABSTRACT How to Design Helical Piles per the 2009 International Building Code by Darin Willis, P.E. 1 Helical piles and anchors have been used in construction applications for more than 150 years. The
Designed and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
World Leader in earth anchoring since 1907. for Residential and Commercial Construction and Repairs
Bulletin 01-9901 Rev. 02/03 POWER SYSTEMS, INC. World Leader in earth anchoring since 1907 INSTANT FOUNDATION Systems for Residential and Commercial Construction and Repairs with the speed of steel for
LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
High Capacity Helical Piles Limited Access Projects
High Capacity Helical Piles Limited Access Projects Tel 403 228-1767 Canada, USA, Russia Brendan ODonoghue 519 830-6113 Presentation Summary 1. Helical piles Background on large diameter shafts and helices
DESIGN, INSTALLATION AND TESTING OF HELICAL PILES & ANCHORS. Presented by: Donald A. Deardorff, P.E. CHANCE Civil Construction Centralia, MO USA
DESIGN, INSTALLATION AND TESTING OF HELICAL PILES & ANCHORS Presented by: Donald A. Deardorff, P.E. CHANCE Civil Construction Centralia, MO USA Historical Perspective 1 st Recorded Screw Pile was by Alexander
Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate
Addendum HELICAL PULLDOWN Micropile (HPM) Introduction The HPM is a system for constructing a grout column around the shaft of a standard Helical Screw Foundation (see Figure A1). To begin the process,
Now That s IDEAL. Now That s IDEAL. LISTEN. RESEARCH. DESIGN. DELIVER.
The Leading Edge SM At IDEAL, we try not to complicate things. We discover needs and problems, then work out solutions. It takes real teamwork to accomplish truly great things. That s you and us, working
BUTE Department of Construction Management and Technology
BUTE Department of Construction Management and Technology 02.10.2012 Definition 1: Foundation: The structure, that transmits the load of the building to the soil Definition 2: Load bearing soil (strata):
load on the soil. For this article s examples, load bearing values given by the following table will be assumed.
How Many Piers? By Gary Collins, P.E. A clear-cut guide to helical pier spacing Introduction Helical pier spacing is not an exact science. How many does it take to support a structure adequately or repair
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Jeff R. Hill, P.E. Hayward Baker Inc. 111 W. Port Plaza Drive Suite 600 St. Louis, MO 63146 314-542-3040 [email protected]
ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE
ENGINEERED FOUNDATIONS Department of Public Works Jeff Hill, PE What is an engineered foundation. A Foundation Design Developed by a Trained Professional (Engineer) Types of Foundations (All of which can
DESIGNING STRUCTURES IN EXPANSIVE CLAY
DESIGNING STRUCTURES IN EXPANSIVE CLAY A GUIDE FOR A RCHITECTS AND E NGINEERS Table of Contents 1. Introduction Page 1 2. Common Foundation Systems Page 2 3. Drilled Piers Page 3 a. Skin Friction Piers
Helical Piles. A Practical Guide to Design and Installation
Brochure More information from http://www.researchandmarkets.com/reports/2216946/ Helical Piles. A Practical Guide to Design and Installation Description: An unbiased, comprehensive review of helical pile
STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
Helical Foundation Systems
Helical Foundation Systems The leading edge in helical foundations MacLean-Dixie The Leading Edge MacLean-Dixie s helical foundation systems offer the leading edge. If you re still considering concrete
The International Workshop on Micropiles, 2007
MICROPILE FOUNDATION REPAIR AND UNDERPINNING, ARTS AND SCIENCE MUSEUM, UNIVERSITY OF PUERTO RICO, MAYAGUEZ Presented at: International Society of Micropiles (ISM) The International Workshop on Micropiles,
Design and Construction of Auger Cast Piles
Design and Construction of Auger Cast Piles 101 th Annual Road School 2015 3/11/2015 Malek Smadi, Ph.D., P.E. Principal Engineer - GEOTILL - Fishers, IN [email protected] - www.geotill.com CONTENTS 1.
RAM JACK INTRODUCTION
RAM JACK INTRODUCTION PROVEN BUSINESS MODEL Billions of dollars in damages are caused by inferior soils each year. How much of this business are you profiting from? Our business systems have proven to
Transmission Foundations Case History : Helical piles Hydro One Networks Inc.
Transmission Foundations Case History : Helical piles Hydro One Networks Inc. www.hubbellpowersystems.com Late in 2008, an aerial patrol discovered three 500kV towers with partially-collapsed foundations
BRIDGE RESTORATION AND LANDSLIDE CORRECTION USING STRUCTURAL PIER AND GRADE BEAM
BRIDGE RESTORATION AND LANDSLIDE CORRECTION USING STRUCTURAL PIER AND GRADE BEAM Swaminathan Srinivasan, P.E., M.ASCE H.C. Nutting/Terracon David Tomley, P.E., M.ASCE KZF Design Delivering Success for
DIVISION: 31 00 00 EARTHWORK SECTION: 31 63 00 BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.
0 ICC ES Report ICC ES (800) 4 6587 (56) 699 054 www.icc es.org 000 Most Widely Accepted and Trusted ESR 794 Reissued 05/05 This report is subject to renewal 05/06. DIVISION: 00 00 EARTHWORK SECTION: 6
Step 11 Static Load Testing
Step 11 Static Load Testing Test loading is the most definitive method of determining load capacity of a pile. Testing a pile to failure provides valuable information to the design engineer and is recommended
TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR
TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR If you listen to the hype, it sounds like there must be 20 or 30 different types of piers out there. Company A says they have an
Helical Pier Foundation System U.S. Patents 5,011,336; 5,120,163; 5,213,448
Helical Pier Foundation System U.S. Patents 5,011,336; 5,120,163; 5,213,448 Technical Manual Contents Helical Pier Foundation System History Research and Development Advantages Theory of Foundation Anchor
Quick fix for frost heave:
Quick fix for frost heave: HELICAL PILES Megan Milbradt Civil Engineer Basin Electric Power Shane Vasbinder Civil Engineer Basin Electric Power Concrete piers were 6 inches to 2 feet out of the ground.
Baton Rouge Foundation Repair
Baton Rouge Foundation Repair 13822 Florida Blvd Bldg 3 Baton Rouge, LA 70819 Baton Rouge Foundation Repair offers services to correct the settlement of both Slab foundations and Pier & Beam foundations
PILE FOUNDATIONS FM 5-134
C H A P T E R 6 PILE FOUNDATIONS Section I. GROUP BEHAVIOR 6-1. Group action. Piles are most effective when combined in groups or clusters. Combining piles in a group complicates analysis since the characteristics
PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE
FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances
POST FOUNDATION REPAIR PERFORMANCE RESIDENTIAL AND OTHER LOW-RISE BUILDINGS ON EXPANSIVE SOILS. The Repair Committee of
Issued for Website Publishing Foundation Performance Association - Repair Committee Page 1 of 10 POST FOUNDATION REPAIR PERFORMANCE OF RESIDENTIAL AND OTHER LOW-RISE BUILDINGS ON EXPANSIVE SOILS by The
Page B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LOAD TESTS
Page B-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 Appendix B CONTENTS STATIC (TIEBACKS)... B-3 STATIC AXIAL (COMPRESSION/TENSION)... B-6 STATIC (LATERAL)... B-9 CAPACITY VERIFICATION
Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations
Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations Cambridge City Council - East Cambridgeshire District Council - Fenland District Council, Huntingdonshire
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils Stephen W. Lacz 1, M. ASCE, P.E. and Richard C. Wells 2, F. ASCE, P.E. 1 Senior Professional, Trigon Kleinfelder, Inc., 313 Gallimore
Pole Guying More Complicated Than Meets the Eye. NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. jason.settle@gdsassociates.
Pole Guying More Complicated Than Meets the Eye NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. [email protected] Pole Guying Strength of components NESC vs. RUS Guy Factor Grounding
USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch
USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and
INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
ENCE 4610 Foundation Analysis and Design
This image cannot currently be displayed. ENCE 4610 Foundation Analysis and Design Shallow Foundations Total and Differential Settlement Schmertmann s Method This image cannot currently be displayed. Strength
Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing
Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Dr.-Ing. Bernd Schuppener, Federal Waterways Engineering
Pro-Lift Steel Pile Foundation Repair
Pro-Lift Steel Pile Foundation Repair Pro-Lift Steel Pile Foundation Repair System Pro-lift steel piles are designed for the stresses of Texas soils. They can have multiple steel walls, depending on the
CITY OF LOS ANGELES CALIFORNIA
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska
APPENDIX B Geotechnical Engineering Report GEOTECHNICAL ENGINEERING REPORT Preliminary Geotechnical Study Upper Southeast Salt Creek Sanitary Trunk Sewer Lincoln Wastewater System Lincoln, Nebraska PREPARED
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
How to Design and Build a Fence/G traverse Bridge or Graffiti Project
Outline Project Location Project Description Project History Site Constraints Geotechnical Investigation & Soil Profile Foundation Design Process Photos Project Location Project Limits: The Grand River
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration
Helical Piles and Anchors Hydraulically Driven Push Piers Polyurethane Injection Supplemental Support Systems
Helical Piles and Anchors Hydraulically Driven Push Piers Polyurethane Injection Supplemental Support Systems FSI Technical Manual Second Edition July 2014 NOTICE AND DISCLAIMER The information contained
DESIGN AND PERFORMANCE OF SCREW PILES AND HELICAL ANCHORS IN SOILS
DESIGN AND PERFORMANCE OF SCREW PILES AND HELICAL ANCHORS IN SOILS (A Bibliography of the Technical Literature) prepared by Alan J. Lutenegger Department of Civil & Environmental Engineering University
Soils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
EVALUATING INSTALLATION DISTURBANCE OF HELICAL ANCHORS IN CLAY FROM FIELD VANE TESTS
EVALUATING INSTALLATION DISTURBANCE OF HELICAL ANCHORS IN CLAY FROM FIELD VANE TESTS Alan J. Lutenegger, John Erikson and Nicholas Williams, Department of Civil & Environmental Engineering, University
INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode
INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance
For a Coastal Site. A Pier-and-Beam Foundation. Our company specializes in oceanfront
A Pier-and-Beam Foundation For a Coastal Site Where unstable soil and periodic tidal flooding are a concern, helical piers topped with a concrete stem wall rise to the challenge by Fred Ambrose Our company
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
Anirudhan I.V. Geotechnical Solutions, Chennai
Anirudhan I.V. Geotechnical Solutions, Chennai Often inadequate In some cases, excess In some cases, disoriented Bad investigation Once in a while good ones Depends on one type of investigation, often
CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS
December 2014 CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications...
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
Dynamic Load Testing of Helical Piles
Dynamic Load Testing of Helical Piles ANNUAL KANSAS CITY SPECIALTY SEMINAR 2014 JANUARY 10, 2014 Jorge Beim JWB Consulting LLC Pile Dynamics, Inc. Main Topics Brief description of the Dynamic Load Test
MANUFACTURED HOUSING USED AS DWELLINGS
MANUFACTURED HOUSING USED AS DWELLINGS SECTION AE101 SCOPE AE101.1 General. These provisions shall be applicable only to a manufactured home used as a single dwelling unit and shall apply to the following:
Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations
Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations Nathan A. Ingraffea, P.E., S.E. Associate, KPFF Consulting Engineers, Portland, Oregon, USA Abstract The use of steel sheet
Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE
Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE To satisfy the performance goals of the NEHRP Recommended Seismic Provisions, a number of characteristics are important to the
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
CIVL451. Soil Exploration and Characterization
CIVL451 Soil Exploration and Characterization 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally
Trenching and Excavation Safety
1.0 ACTIVITY DESCRIPTION 1.1 This document provides basic safety guidelines related to excavation and trenching in pipeline construction activities. These guidelines are applicable to the locating, marking
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Chapter 9 Remedial Measures
[This is an annotated version of a chapter from the US Army Corps of Engineers book, Foundations in Expansive Soils. This book is in the public domain. This document is consists of an abbreviated and annotated
How To Design A Foundation
The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural
ALLOWABLE LOADS ON A SINGLE PILE
C H A P T E R 5 ALLOWABLE LOADS ON A SINGLE PILE Section I. BASICS 5-1. Considerations. For safe, economical pile foundations in military construction, it is necessary to determine the allowable load capacity
Helical Pier Foundations
Screw piers are a cost-effective option for steep sites and expansive soils Helical Pier Foundations FOR PROBLEMSITES SITES Our company, HighCraft Builders in Fort Collins, Colo., specializes in room additions
Outline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.
MICROPILES SUBJECT TO LATERAL LOADING Dr. Jesús Gómez, P.E. Micropile Design and Construction Seminar Las Vegas, NV April 3-4, 2008 Outline When are micropiles subject to lateral load? How do we analyze
APPENDIX G SETTLEMENT
APPENDIX G SETTLEMENT TABLE OF CONTENTS G.1 IN T R O D U C T IO N... 1 G.2 MATERIAL PLACEMENT AND COMPACTION... 1 G.2.1 Incom pressible M aterials... 1 G.2.2 Compressible Materials... 2 G.2.3 Soil P lacem
SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS
SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS Vince Luongo Petrifond Foundation Co., Ltd. PROJECT DESCRIPTION The York Durham Sanitary System (YDSS) Interceptor in the Town of Richmond Hill located
COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2
(PREVIEW) SP 36 (Part 2) : 1988 COMPENDIUM OF INDIAN STANDARDS ON SOIL ENGINEERING PART 2 IS 1893 : 1979 (Reaffirmed 1987) CODE OF PRACTICE FOR SUBSURFACE INVESTIGATION FOR FOUNDATIONS 1.1 This code deals
HELICAL SCREW PILE FOUNDATIONS. Presented by: Laurence Boakes Azimuth Structural Engineering Ltd.
HELICAL SCREW PILE FOUNDATIONS Presented by: Laurence Boakes Azimuth Structural Engineering Ltd. Historical Perspective 1 st Recorded use of a Screw Pile was by Alexander Mitchell in 1836 for Moorings
ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT
ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT Description: This work shall consist of furnishing all materials, equipment and labor necessary for conducting an Osterberg Cell (O-Cell) Load
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
Lighthouse Engineering, L.L.C.
Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: [email protected] Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering
symptoms of a faulty foundation
symptoms of a faulty foundation How does drought impact your home's foundation? For many Texas families, their home becomes the single largest investment and also the family fortune. The home's foundation
Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training
Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
COSMOS 2012: Earthquakes in Action COSMOS 2012
COSMOS 2012 What is SFSI and why is it important? Soil issues in Earthquakes Structures where SFSI important Retaining structures (lateral earth pressure) Foundations (spread and pile footings, bearing
Underpinning Systems 14.1 FOUNDATION REPAIR. Helical Piles
Helical Piles Howard A. Perko Copyright 0 2009 by John Wiley & Sons, Inc. All rights reserved. C h a p t e r 14 Underpinning Systems There has been tremendous growth in the use of helical piles for underpinning
1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum
Malaysian Civil Engineering Standard Method of Measurement (MyCESMM) CLASS D: SITE INVESTIGATION WORK Measurement covered under other classes: Excavation not carried out for the purpose of soil investigation
Foundation Underpinning Process and Relationship with Groundwater in West- Central Florida
Foundation Underpinning Process and Relationship with Groundwater in West- Central Florida Ahmed Said, PhD, PE Principal Engineering Consultant, Sinkhole Geotech, Inc. e-mail: [email protected]
Copyright by W. Tom Witherspoon. All Rights Reserved. Soil Stabilzation of Oklahoma, Inc
Copyright by W. Tom Witherspoon All Rights Reserved LOAD CAPACITY TESTING AND ANALYSIS OF RESIDENTIAL UNDERPINNING SYSTEMS IN EXPANSIVE CLAY ENVIRONMENT by WILLIAM THOMAS WITHERSPOON Presented to the Faculty
Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS. J. David Rogers, Ph.D., P.E., R.G.
Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS J. David Rogers, Ph.D., P.E., R.G. Cone Penetration Test CPT soundings can be very effective in site characterization, especially sites with discrete
The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
4.3.5 - Breakaway Walls
4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free
