VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control



Similar documents
97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Single sub-base valve

Proportional pressure regulators VPPE

Combi switchbox with integrated 3/2 way pilot valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

RM/55401/M, Roundline cylinder Magnetic piston, double acting

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

REGTRONIC OPERATING INSTRUCTIONS

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Electronic Pressure Switch EDS 300

On-off valves MS-EM/EE, MS series, NPT

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

zamak nitrile rubber self-extinguishing technopolymer aluminum

How To Use A Flowmeter

Cable Plug acc. to DIN EN , Form A

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

2/2 and 3/2 Way Size 6 Seat Valves

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Pressure transmitter For general industrial applications Model A-10

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

4/2-Way Pneumatic Solenoid Valve

Digital display DA 48

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

type V46, solenoid or pneumatic operated

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Control block VOFA with safety function

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

3/2-way Solenoid Valve, direct-acting, NC or NO

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Control blocks for two-hand start ZSB

Conductive Level Switch FK 2 Technical Data:

MINI MCR-SL-R-UI(-SP)

Electronic Pressure Switch EDS 3000

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

ISO /2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Proximity Switches RS (Reed Switch)

Service units MSB-FRC, MS series

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Series 6000 Torque measured metal bellow coupling

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting

G1/4 Q8. Standard with biased position

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

Electro-pneumatic control valves

Actuators and positioning drives

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

4 Posiflow Proportional Solenoid Valves

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Inductive sensor NI10-M18-Y1X-H1141

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Digital inductive conductivity transmitter

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Relative and absolute pressure switch type 529

Series 7500 Torque Sensor

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

System 8. ü ( System 8

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Actuator for modulating control AME 435

Unit 24: Applications of Pneumatics and Hydraulics

OEM-EP Pressure Controllers

Assisted lift operated 2/2-way solenoid valves Type EV250B

zamak nitrile rubber self-extinguishing technopolymes aluminum

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Pressure switches for gas and air Pressure sensors

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Transcription:

VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request) > > Free of lacquer affecting substances > > Optional: serial interface with VP-Tool Software P = W X µp Technical features Medium: Filtered (5 μm), unlubricated or lubricated condensate-free compressed air or neutral gases Due to the lubricants and their additives, use of lubricated compressed air can affect the dynamics and service life Operation: Proportional solenoid Pressure range: Operating pressure P max: bar ( psi), bar ( psi), bar ( psi) Operating pressure P: (,)... bar (... 9 psi) (,)... bar (... 5 psi) (,)... bar(... psi) Flowrate: See flow characteristics Flow direction: >, > Service life: > Million operations, max. stroke Linearity: < ±, % (p max.) Control accuracy: < ±, % (p max.) Response accuracy: < ±, % (p max.) Hysteresis: < ±,5 % (p max.) Repeat accuracy: < ±,5 % (p max.) values related to C and V d.c. power supply Ambient: Valve series is designed for indoor use at normal industrial ambient Ambient/Media temperature: Media -5... +5 C (+... + F) (no condensation permitted) Ambient -5... + C (+... + F) Air supply must be dry enough to avoid ice formation at temperatures below + C (+5 F). Materials: Valve housing: Aluminium Electronic housing: PAA Seals: NBR, HNBR on request Internal parts : PBT Springs : Steel Option selector VP B Pressure range... bar... bar... bar Nominal size mm D mm E Set point... ma... V/Diff. Profibus DP P Option Serial interface B Serial interface + LED-display * B Connector M/ pin M Fieldbus spec. (on request) N Actual value... V/... ma Profibus DP P * LED-display for bus version not available without notice, the specifications given in this document. ( - d) 5 Norgren GmbH /5 en..5.

VP, -way proportional pressure control valves Function The electronic pressure controller is used in conjunction with an electric set-point (control signal) to quickly and precisely set a pressure at the pressure connection (). Even with consumption of the medium (compressed air or neutral gases) the output pressure is controlled (see flow rate characteristics) Proportional valves are used in many different applications across all sectors of industry. They are used anywhere where precise and fast direct or indirect control of pressure, force, rotational speed etc. is required. Application example: Contact pressure control of welding electrodes in automotive manufacture Assembly The electronic pressure controller consists of: - Proportional solenoid - An integrated pressure sensor - µp-driven control electronics - Serial interface - A pneumatic control plunger - Optional: Fieldbus interface Configuration software VP-Tool (please order separately) LED display for the size of the output pressure Operating principle The valve has a closed loop controller, meaning that the output pressure is constantly being measured by the internal pressure sensor and compared to the specified set-point. If the output pressure is lower than the set pressure or if a higher pressure is desired, the pneumatic control plunger is actuated by the electric proportional solenoid. A connection is then established between connection (input pressure) and (output pressure) until the pressure is the same as the specified set-point. If the output pressure is higher than the set pressure or if a lower pressure is desired, the pneumatic control plunger is actuated by the electric proportional solenoid. A connection is then established between connection (input pressure) and (ventilation connection) until the pressure is the same as the specified set-point. In addition, after the supply voltage is switched off, the output pressure set last is vented down to bar. Electrical parameters Endurance limit in relation to oscillations to DIN EN --: g at -5Hz in switched-off-status Supply Supply voltage UB... V d.c. Residual ripple max. [%] Current consumption NG, max. [A] approx., A at V d.c. at bar NG, static at 5 C (corrected) [A] approx., A at V d.c. Current consumption NG, max. [A] approx., A at V d.c. at bar NG, static at 5 C (corrected) [A] approx., A at V d.c. Current consumption NG, max. [A] approx., A at V d.c. at bar NG, static at 5 C (corrected) [A] approx., A at V d.c. Inputs (signal) Set point W (+/-U d) analogue differential Voltage signal UE (V)... Input resistance RI (kω) Set point W(I) analogue: Current signal UE (ma) Burden (Ω) Outputs (signal) Output pressure actual value X(U) Voltage signal of pneumatic output pressure UA (V) Output current max. IA (ma)... 5 Max. input voltage (V) -...... V =... max. p Durability under shock effect to DIN EN --: g/ shocks Valves should not be used in safety systems that require blocking or exhaust valves Without power the pneumatic connection -> is open Output pressure actual value X(I) Current signal of pneumatic output pressure IA (ma) Load resistance RL (Ω) ()... ma =... max. p 5 recommended Output»pressure reached«x (comp) Switching range (% max. p) +/-% Digital output signal PLC-Level Control pressure outside of Low switching range (X W) Pressure reached (X = W) (V) High Outout current max. (ma) en..5. without notice, the specifications given in this document. ( - d) 5 Norgren GmbH /5

VP, -way proportional pressure control valves Pneumatic parameters Recommended application area by nominal value: NG: Volume (closed) from... 5 cm NG: Volume (closed) from... cm Residual ripple max. [%] Input pressure p max. [bar] // Output pressure p max. [bar] - / - / - Flow quantity NG [l/min] see diagram Flow quantity NG [l/min] see diagram Switching times (%-9%) nominal size at volume cm Typical values for P= bar Pressure build-up (tr) bar... 9 bar [ms] Pressure build-up (tf) bar... 5 bar 5 [ms] Pressure drop (tr) 9 bar... bar 5 [ms] Pressure drop (tf) 5 bar... bar 5 [ms] Switching times (%-9%), nominal size at volume cm Typical values for P= bar Pressure build-up (tr) bar... 9 bar [ms] Pressure build-up (tf) bar... 5 bar 5 [ms] Pressure drop (tr) 9 bar... bar [ms] Pressure drop (tf) 5 bar... bar 5 [ms] Test assembly flow CETOP RP P.: flow characteristic of pneumatic devices Step-response diagram p (bar) tr tf t (ms) /5 without notice, the specifications given in this document. ( - d) 5 Norgren GmbH en..5.

VP, -way proportional pressure control valves Pneumatic characteristics curves Flow rate characteristic as a function of the set-point (voltage/current) and input pressure bar, bar, bar for nominal value and Static characteristics p p = f(w) (bar), 9,,,, 5,,,,, t (ms) Z 5 9 U E[V], p (bar),,, "Z" p = f(w) 5 9 W [%] 5,,,,, 5,,, I E [ma] Flow rate characteristics NG /P= bar, bar, bar p (bar) p (bar) p (bar) 5 5 5 5 5 5 5 Q (l/min) 5 5 5 5 Q (l/min) 5 5 5 5 Q (l/min) Flow rate characteristics NG /connection plat ae / (NG); P= bar, bar, bar p (bar) p (bar) p (bar) 5 5 5 5 Q (l/min) Q (l/min) Q (l/min) Flow rate characteristics NG /connection plate / (NG); P= bar, bar, bar p (bar) p (bar) p (bar) 5 5 5 5 5 5 5 5 Q (l/min) Q (l/min) Q (l/min) en..5. without notice, the specifications given in this document. ( - d) 5 Norgren GmbH /5

VP, -way proportional pressure control valves Functional descriptions, status LED and amplification degree setting General Status LED indicator) Status Status-LED Device off off Device running single-colour green Valve fault* red* Outout current max. (ma) * Potential error sources: - Current supply or internal references outside the permitted range - Valve not adjustable (X W Time out) - Program cycle interrupted Function Option LED indicator Pressure range Display values... bar,...,... bar,...,... bar,..., coloured LED-display LED indicator green pressure devation from setpoint < +/- % LED indicator red pressure devation from setpoint > +/- % Setting controller gain via PC with VP-Tool The gain of the integrated controller is set in the factory to a value which allows universal use of the valve. If necessary, the controller gain can be varied to suit a specific pneumatic application of the valve. When the screw plug is opened the interface connector can connected and via VP-Tool the controller gain can be adjusted. Adjustment by VP-Tool via serial interface Connection diagrams. Standard connection (Mx; -pin) Status 5 5 Assignment Supply: W (I), white X (komp), brown W (-Ud), green W (+Ud), yellow 5 X (I), grey Ub pink GND blue X (U), red Pin Description Colour of connection cable Ub power supply... V d.c. Pink GND power ground/pgnd Blue Input Set point: Pin Description Colour of connection cable -W Analogue GND/set point input voltage... V Green +W Signal/set point input voltage... V Yellow W(I) Set point input current... ma White Depending on the order number, both outputs (U/I) but only the ordered input will be active. Voltage input... V between pins and Current input between pins and Comparator output/pressure switch* Pressure reached: Pin Description Colour of connection cable X (comp) Digital output signal PLC level (I max) =, ma Brown High : pressure reached devation Iw-xI < ± % Low: pressure not reached devation Iw-xI > ± % The output relates to Gnd Pin * selectable via VP-Tool Output 5 5 Pin Description Colour of connection cable 5 X(I) Actual value current... ma Grey X(U) Actual value voltage... V Red Voltage output refers to Gnd Pin. Due to the voltage drop on the ground wire you should consider an accuracy loss of the voltage output. Both outputs are active as standard.. Serial interface connection Connection of serial interface Remove fitting, plug in the interface cable, establish communication with VP-Tool. /5 without notice, the specifications given in this document. ( - d) 5 Norgren GmbH en..5.5

VP, -way proportional pressure control valves Connecting plugs Description Specification Model Connecting plug Mx; -pin; 5 m, x,5 mm, straight 5 Connecting plug Mx; -pin; 5 m, x,5 mm, 9 5 Connecting plug Mx; -pin; screw terminals, 9 5 Connector (Bus only) Mx, 5-pin, 5 m, 9, A-Coded, open (power) 5 Connector (Bus only) Mx, 5-pin, 5 m, straight, A-Coded, open (power) 5 Connector (Bus only) Mx, 5-pin, 5 m, 9, A-Coded, open (power) 5 Connector (Bus only) Mx, 5-pin, 5 m, 9, B-Coded, open (Bus in) 5 Connector (Bus only) Mx, 5-pin, 5 m, 9, B-Coded, open (Bus out) 5 Connector (Bus only) Mx, 5-pin, convertible, 9, B-Coded (Bus in) 59 Connector (Bus only) Mx, 5-pin, convertible, 9, B-Coded (Bus out) 59 Connector with cable (Bus only) Plug Mx, 5-pin, 5m, 9, B-Coded, (Bus in/out) 59 Note: Cable material PUR shielded Connection plates Serial interface accessories Adaptor cable Description Ports Model Connection plate NG G/ 5 Connection plate NG G/ 55 Connection plate NG G/ 5 Connection plate NG G/ 5 Description Adaptor cable with software CD VP tool 599 Model en..5. without notice, the specifications given in this document. ( - d) 5 Norgren GmbH /5

VP, -way proportional pressure control valves Basic dimensions Standard ND,5 M5 Dimensions in mm Projection/First angle 5,5,5 5,5 55,5 Ø5,5 Connection plate M x ø ø 5,5,5 5 9 ~ ~ ~,5,5,5 5,5,5,5 5,5 55,5 ~ 5 Ø 5,5 ND with serial interface, LED indicator 5 Status /5 without notice, the specifications given in this document. ( - d) 5 Norgren GmbH en..5.

VP, -way proportional pressure control valves Dimensions ND M5 Dimensions in mm Projection/First angle 5 5 5 Connection plate,5,5 5 5,5 ø ø, M x ~ ~ ~,5 Ø, Ø 59 9,5 ~ 5 5,5 5,5 Dimensions optional serial interface, LED indicator ND,5 Status en..5. without notice, the specifications given in this document. ( - d) 5 Norgren GmbH /5

VP, -way proportional pressure control valves Connection plate 55, G/ ports preferable for VPxxBDxxxxxxx valve Dimensions in mm Projection/First angle 5, G/ ports optional for VPxxBDxxxxxxx valve 55,5 5,5,5.5,5 A,5 9 5,5 G / A M5 -,5 A,5,5,5 Ø 5,5 A Ø 5,5,5,5 55 5, G/ ports preferable for VPxxBExxxxxxx valve /5 without notice, the specifications given in this document. ( - d) 5 Norgren GmbH en..5.9

VP, -way proportional pressure control valves Connection plate 5, G/ ports optional for VPxxBExxxxxxx valve Dimensions in mm Projection/First angle Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. en..5. without notice, the specifications given in this document. ( - d) 5 Norgren GmbH /5