Electroluminescent (EL) Parallel Panels



Similar documents
Electroluminescent Materials

How To Make A Thin Film Electroluminescent Display (Tfel) Display

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

How To Use A Power Supply On A Powerline 2.2 (Ai)

User s Manual AURORA 1.2K/2.2K

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

Guideline Laser Series

EMERGENCY EGRESS LIGHTING POWER SUPPLY PART NO COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

Backlight Technology Overview

How To Use A Power Supply Unit (Upu)

How To Use A Ds340 (Dsp)

Stroom voor elke toepassing

INDICATOR LAMPS & LED REPLACEMENT LAMPS

Handheld portable appliance testers

RY2 miniature industrial relays

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Electronic Control Devices The European Product Catalogue 2007

22" Widescreen LED Monitor VA2261-2

Neal O Hara. Business Development Manager

Displays ready for Signage

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

SECTION 13. Multipliers. Outline of Multiplier Design Process:

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

WINGLIKE ELECTRONICS CO.,LTD

BATRON DOCUMENT NUMBER AND REVISION VL-FS-BTHQ 21605VSS-02 REV.A (BTHQ 21605VSS-FSTF-LED05W(1 DIE)) Feb/2002 BTHQ FSTF-LED WHITE 1/15

Information sheet. 1) Solar Panels - Basics. 2) Solar Panels Functionality

22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224

User Manual for CH-PFC76810

Multi-Function Ground

SUCCESS EPCOS Capacitors

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Emergency lighting units EM powerled

10000HXL31/15000HXL31/20000HXL31


PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Online UPS. PowerWalker VFI 1000R/1U

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

FOR MESSRS. : WC1602A PAGE: 1/12 CONTENTS

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

Product Catalogue Windo and PromoDek are registered trademarks of Windo Displays, The Netherlands

NC-12 Modbus Application

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

VG2435Sm :10 Ergonomic Multimedia Display. Overview. See More, Work More with a 16:10 Aspect Ratio Display

USER MANUAL Online UPS 1K/2K/3K Rack

TruPower-Portable-500W. Solar Starter kit

2013 Wireless Video Intercom INSTALLATION GUIDE

NX safety stand-alone

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

LG Transparent Display Introduction

Digital input modules

19" 5:4, Flicker Free IPS LED Monitor with VGA and DVI VA951S

User s Manual Before using the inverter, you need to read and save the safety instructions.

ST Series POWER SUPPLIES USER INSTRUCTIONS

RADIANT PLASMA 4700 Plasma Spark Generator

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Data International Co., Ltd. DATAVISION APPROVAL SHEET. Approved Checked Prepared Sheet Code:

CARD CUTTER MACHINE STUDENT.MANUAL

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Index. ROPIX P18 Hardware ROPIX P18 Software ROPIX P18

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

User Manual 1K/2K/3K Online UPS

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Solid-State Timer H3G

USER MANUAL Online UPS 1K/2K/3K

A&C Solutions: please contact us.

Adjustment functions for both span and shift have been incorporated

Agilent 4339B/4349B High Resistance Meters

COMPALARM AP GENERAL MAIN FEATURES

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Preset Counter signo 721

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

User Guide. 4 wire Earth Resistance Tester Model GRT300

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

K-Type Thermocouple Sensor User s Guide

Instruction Manual for IV-08MTV LCD Color Monitor

CQM1-SF200/CS1W-SF200

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

High-ohmic/high-voltage resistors

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Thermal-Magnetic Circuit Breaker M1-..

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70

Transcription:

Electroluminescent (EL) Parallel Panels

Surelight Electroluminescent (EL) Parallel Panels EL Parallel Panel Data Sheet Electroluminescent technology is the new paper thin, enticing light source that is revolutionising the way businesses market their branded message to target audiences. Electroluminescent Panels (EL Panels) are set to take over back lit posters with 75% of energy saving amongst a host of other light source based products that are energy deficient, expensive and bulky. EL Panels can be used across a wide range of applications including retail displays, signage, advertising, architecture, automotive applications, entertainment, safety lighting and more. Surelight s Electroluminescent Panels can be customised to illuminate in any size, shape, colour or sequence, making them ideal for making eye catching retail displays or engaging animated point of sale displays. Surelight s Electroluminescent Panels have been used in a wide range of bars and night clubs in both signage or in architectural roles, built into stone counter tops, tables or even floors, the list of applications of our Electroluminescent Panels is endless.

Specifications are typical and may change without notice EL Parallel Panel Construction Description Electroluminescent Parallel Panels from surelight.com are made of a multi layer material containing fluorescent dyes, dispersed in a binder with a high electrical constant. When an alternating current (AC) is applied, the EL Panel (sheet) emits light. EL Panels emit light from 50VAC and increase in brightness AC with higher voltage up to 200VAC. The frequency should be over 50Hz. Brightness increases with higher frequency up to 1000Hz. However we recommend that frequencies in the range of 400-600Hz and voltages of no greater than 160VAC are used, otherwise the parallel panels life will rapidly deteriorate. Transparent electrode film Luminescent layer Insulating layer Back electrode Protective Layer Features Ultra thin Flexible Highly efficient - Low energy, low temperature Easily cut to desired shape Vibration & shock resistant Different section can be activated separately Ordering EL Parallel Panels from Surelight.com There are several ways to order EL Panels: As standard format: A2 609 x 435 mm A3 435 x 317 mm A4 312 x 230 mm Y1 415 x 135 mm As special format: Any size (within the above standard formats) can be ordered Custom Size: Special form and formats can be arranged from your specification Custom Shape: Custom shaped panels can be arranged from your specification Animated Multi EL Panel displays: Whilst the production method is more technical than tradition shaped EL Panels, Surelight offer multi EL Panel animation for point of sale, advertising applications, retail display etc, please contact us for more information regarding Animated EL Panel displays. All Surelight s EL Panel range are supplied pre-laminated for added protection with appropriate connections, inverters are sold separately in our online shop or by contacting us directly.

Specifications are typical and may change without notice EL Parallel Panel - Applications, Colours & Connections EL Parallel Panel Applications LCD Backlighting Automotive Instrument Panels Advertising Display Retail Display Signage Architecture Electronics; Watches, Mobile phones, other appliances Race car Number Panels (for night racing) Safety Lighting EL Parallel Panel Colours/Brightness We believe that Surelight s EL Parallel Panels are the brightest currently available anywhere in the world, denser coatings and higher quality phosphor on our EL Panels make them second to none. Item Unit Minimum Typical Maximum High Brightness Brightness cd/m 2 70 105 - White Chromaticity X 0.26 0.29 0.32 Y 0.36 0.40 0.44 High Brightness Brightness cd/m 2 80 125 - Aqua (Blue/ Green) Chromaticity X 0.165 0.195 0.225 Y 0.44 0.48 0.46 EL Parallel Panel lamination All Surelight EL Panel range are supplied pre-encapsulated (laminated) unless otherwise requested at the time of ordering. Lamination protects against moisture and mechanical damage. EL Parallel Panel Connections Most Surelight EL Panels are supplied pre-connected unless otherwise requested at the time of ordering. Surelight use the highest quality connections, these connections have been designed to easily snap together making connecting and removing our EL Panels simple. Surelight Connection view from EL Panel back Surelight Connection on an unlit High Brightness Aqua EL Panel

EL Parallel Panel - Available Standard Sizes Specifications are typical and may change without notice Bus bar Encapsulation (Clear) EL Panel (Lit Area) Connection Tab 614 mm 144 mm 594 mm 124 mm 22 mm 435 mm 420 mm A2 22 mm 418 mm 403 mm Y1 440 mm 420 mm 317 mm 312 mm 297 mm 225 mm 210 mm 297 mm A3 22 mm A4 22 mm Sizes may vary slightly depending on connection orientation

Specifications are typical and may change without notice EL Parallel Panel - Life Time Brightness versus accumulated lighting time Relative brightness in % of initial value 100 90 80 70 60 50 40 30 20 10 Conditions: 100VAC, 400Hz, 20 o C, 65%RH 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Unlike most other lighting which can critically fail, EL Panel brightness decreases with time. Factors which have an impact on lifetime: Higher Voltage Higher Frequency DC Supply High Ambient Humidity High Ambient Temperature Accumulated lighting time in hours Brightness can be increased by using a higher voltage or higher frequency. Higher voltage slightly decreases life time, but is preferred if higher supply current can be accepted. Higher frequency considerably reduces lifetime, but is useful where low supply current is essential, higher frequency is most suited to applications with a short operating time. DC supply should be avoided as lifetime of EL Panel will be reduced, If it is not possible to avoid DC, the + pole must ne connected to the top (transparent) electrode.

Supply Current - Current in ma/cm 2 versus supply voltage 0.25 0.2 ma/cm 2 0.15 0.1 0.05 20 40 60 80 100 120 140 160 Supply Voltage (AC 400Hz) Brightness in cd/m 2 versus supply voltage 120 110 100 90 80 70 60 cd/m 2 50 40 30 20 10 0 20 40 60 80 100 120 140 Supply Voltage (AC 400Hz) Type: High Brightness Aqua Type: High Brightness White

EL Parallel Panel - Plug & Play System Specifications are typical and may change without notice Surelight Offers: EL Parallel Panels in a plug and play system Standard Laminated EL Parallel Panels - A2, A3, A4 - Y1 with connectors (inverter sold separately) Custom size EL Parallel Panels Custom shaped EL Parallel Panels Power Supply Units A range of inverters to power any size of EL Parallel Panel. Typical Plug & Play EL Parallel Panel Setup Mains Power Supply 95-240V AC input 12V DC output EL Panel 12V DC Battery or Inverter Connectors A 12VDC power supply is required, either from a mains PSU with 12DC output or a 12VDC Battery.

Specifications are typical and may change without notice EL Parallel Panel - Evaluation Kits Try our EL Parallel Panels We believe our Parallel EL Panels are of the highest quality and the brightest in the world. Surelight EL Parallel Panel Evaluation kits are the perfect way to try or EL Panels. For those who have never used or seen EL Panels in action before an EL Panel Evaluation Kit can give you a good idea if EL is right for your particular project. Our EL Panel Evaluation Kits are available for purchase in our Online Shop or by contacting Surelight directly. Available in 3 sizes: small, medium or large