Our target is an EqualLogic PS100 Storage Array with a portal address of



Similar documents
QNAP and Failover Technologies

istorage Server: High-Availability iscsi SAN for Windows Server 2008 & Hyper-V Clustering

Drobo How-To Guide. Topics. What You Will Need. Configure Windows iscsi Multipath I/O (MPIO) with Drobo iscsi SAN

N5 NETWORKING BEST PRACTICES

Step-by-Step Guide to Open-E DSS V7 Active-Active Load Balanced iscsi HA Cluster

Compellent Storage Center

Configuring Security for FTP Traffic

istorage Server: High Availability iscsi SAN for Windows Server 2012 Cluster

Introduction to MPIO, MCS, Trunking, and LACP

How to Create a Virtual Switch in VMware ESXi

Configuring the BIG-IP and Check Point VPN-1 /FireWall-1

Deploying Silver Peak VXOA Physical And Virtual Appliances with Dell EqualLogic Isolated iscsi SANs including Dell 3-2-1

Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering

Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center

Step-by-Step Guide. to configure Open-E DSS V7 Active-Active iscsi Failover on Intel Server Systems R2224GZ4GC4. Software Version: DSS ver. 7.

Step-by-Step Guide to Open-E DSS V7 Active-Active iscsi Failover

Configuring Windows Server Clusters

Load Balancing IBM Lotus Instant Messaging and Web Conferencing Servers with F5 Networks BIG-IP System

Chapter 6 Configuring the SSL VPN Tunnel Client and Port Forwarding

Configuration of a Load-Balanced and Fail-Over Merak Cluster using Windows Server 2003 Network Load Balancing

How To Set Up A Two Node Hyperv Cluster With Failover Clustering And Cluster Shared Volume (Csv) Enabled

IntraVUE Plug Scanner/Recorder Installation and Start-Up

Configuring MassTransit Server to listen on ports less than 1024 using WaterRoof on Macintosh Workstations

vsphere Networking ESXi 5.0 vcenter Server 5.0 EN

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

1 PC to WX64 direction connection with crossover cable or hub/switch

PowerLink Bandwidth Aggregation Redundant WAN Link and VPN Fail-Over Solutions

Quick Guide of HiDDNS Settings (with UPnP)

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

StarWind iscsi SAN Configuring HA File Server for SMB NAS

ipad Installation and Setup

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Introducing the BIG-IP and SharePoint Portal Server 2003 configuration

Quick Guide of DDNS Settings

STORAGE SIMPLIFIED: INTEGRATING DELL EQUALLOGIC PS SERIES STORAGE INTO YOUR HP BLADE SERVER ENVIRONMENT

StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers

Microsoft Windows Server Multiprotocol Multipathing with the Oracle ZFS Storage Appliance

Configuring Security for SMTP Traffic

Using Cisco UC320W with Windows Small Business Server

MaxSea TimeZero NN3D Radar Connection Checklist

Dell Compellent Storage Center

Installation Guide July 2009

Quick Note 53. Ethernet to W-WAN failover with logical Ethernet interface.

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)

Network Load Balancing

NETFORT LANGUARDIAN INSTALLING LANGUARDIAN ON MICROSOFT HYPER V

How to Enable/Disable TCP Offload Overview

Deploying the BIG-IP System with Oracle E-Business Suite 11i

ADVANCED NETWORK CONFIGURATION GUIDE

HP ProLiant DL380 G5 High Availability Storage Server

Appendix C Network Planning for Dual WAN Ports

Chapter 6 Virtual Private Networking Using SSL Connections

Lab - Configure a Windows 7 Firewall

Link Load Balancing :50:44 UTC Citrix Systems, Inc. All rights reserved. Terms of Use Trademarks Privacy Statement

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

F-SECURE MESSAGING SECURITY GATEWAY

Configuring a customer owned router to function as a switch with Ultra TV

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

Basic ViPNet VPN Deployment Schemes. Supplement to ViPNet Documentation

Coyote Point Systems White Paper

NNAS-D5 Quick Installation Guide

Configuring Network Address Translation (NAT)

Deployments and Tests in an iscsi SAN

Multi-Homing Dual WAN Firewall Router

Owner of the content within this article is Written by Marc Grote

Windows Host Utilities 6.0 Installation and Setup Guide

Guide to the LBaaS plugin ver for Fuel

Biznet GIO Cloud Connecting VM via Windows Remote Desktop

Multipathing Configuration for Software iscsi Using Port Binding

Parallels Plesk Panel

HP StoreVirtual DSM for Microsoft MPIO Deployment Guide

Setting Up Your FTP Server

StorSimple Appliance Quick Start Guide

DDNS Management System User Manual V1.0

Using Multipathing Technology to Achieve a High Availability Solution

LOAD BALANCING 2X APPLICATIONSERVER XG SECURE CLIENT GATEWAYS THROUGH MICROSOFT NETWORK LOAD BALANCING

Drobo How-To Guide. Use a Drobo iscsi Array as a Target for Veeam Backups

Configuring the Beckhoff BK9000 Network Parameters

Configuring the WT-4 for ftp (Ad-hoc Mode)

Windows Host Utilities Installation and Setup Guide

DEPLOYMENT GUIDE Version 1.2. Deploying the BIG-IP system v10 with Microsoft Exchange Outlook Web Access 2007

Load Balancing. Outlook Web Access. Web Mail Using Equalizer

Quick Guide of DDNS Settings

White Paper. ThinRDP Load Balancing

Introduction. Versions Used Windows Server 2003

DEPLOYMENT GUIDE. Deploying F5 for High Availability and Scalability of Microsoft Dynamics 4.0

Optimum Business SIP Trunk Set-up Guide

Setup for Windows XP Connect to your Windows XP machine with: FileBrowser, NetPortal & ServerControl

Configuring Routers and Their Settings

Host Integration Tools

Lab - Configure a Windows Vista Firewall

D-Link Central WiFiManager Configuration Guide

Veritas Cluster Server

Setting up Scan to

Requirements Collax Security Gateway Collax Business Server or Collax Platform Server including Collax SSL VPN module

MULTI WAN TECHNICAL OVERVIEW

How to connect your new virtual machine to the Internet

Configure Windows 95 after a Domain name change Configure TCP/IP correctly using DHCP Eliminate Network Traffic by Disabling Sharing

Transcription:

iscsi Multi-Path I/O (MPIO) Example This is a example of how to create an MPIO connection to an iscsi target in a high performance environment. By high performance, we mean that we have an isolated VLAN for iscsi traffic, and that only iscsi traffic will travel on the VLAN. All nonessential protocols (Netbios, client for Microsoft networks, etc.) have been unbound from our iscsi interfaces. We will be connecting to a target that supports active-active using the Microsoft DSM Round-Robin mode. This document is provided as a convenience only. If you have access to the Microsoft iscsi initiator Users Guide version 2.06 or later, you should reference that document, as it has a much more thorough treatment of this subject. Furthermore, that document should be regarded as authoritative if there are conflicts with these instructions, unless those conflicts are specific to the way Alacritech products function. Before starting, you need to make sure that the target you plan to use supports MPIO, and that it supports active-active connections. If the target supports MPIO, but does not support active-active, you can still make an MPIO connection, but the only supported mode will be failover. There's nothing wrong with failover mode, it gives you network redundancy, but it does not provide the performance increase that the other MPIO modes do. The other thing you should know is whether you target manufacturer has their own MPIO DSM (Device Specific Module). If they do, it may be preferable to use their DSM mode instead of using the round-robin mode that we use in this example. Our target is an EqualLogic PS100 Storage Array with a portal address of 192.168.51.1/22. The target has 3 ethernet interfaces all on this subnet. The target has already had a volume set up, and has been configured so that our initiator host has access to it. The inititator host is running Windows Server 2003 R2 SP2, and has the Windows iscsi initiator version 2.07, including MPIO, installed. It has an Alacritech SES2002XT dual port iscsi Accelerator that we will be using to connect to the target. The iscsi interfaces are configured as follows: C:\Temp>ipconfig Windows IP Configuration... Ethernet adapter 3A_iSCSI: Connection-specific DNS Suffix. : IP Address............ : 192.168.50.105 Subnet Mask........... : 255.255.252.0 Default Gateway......... : Ethernet adapter 3B_iSCSI: Connection-specific DNS Suffix. : Alacritech Documentation 1

IP Address............ : 192.168.50.125 Subnet Mask........... : 255.255.252.0 Default Gateway......... : After opening the iscsi initiator applet, the first thing we do is add the portal address of the PS100. Once the portal address has been entered, the available targets are displayed. It is not obvious which target we want to log on to, so we need to look at the configuration of the target itself. Since that process is different for each manufacturer s target, we won t cover that here, but by default, we know the highlighted target is the one we want. Alacritech Documentation 2

Click "Log On", and check both the box for persistent connections and the box for Multi- Path. Alacritech Documentation 3

We then select "Advanced" so that we can configure the individual connects. Set "Local adapter" to "Microsoft iscsi Initiator", and select one of the two IP addresses on our iscsi network as the source IP. Alacritech Documentation 4

Next we select the destination address. On most targets we would see several destination addresses here, one for each ethernet interface, and we would chose one. The PS100 is different though. Because EqualLogic uses a technology called iscsi redirect, we see only one address here. We select that address, and the PS100 will take care of redirecting the connection to the appropriate interface. Alacritech Documentation 5

After hitting "OK" several times, we get back to the target window which now shows as "connected". Alacritech Documentation 6

Now we simply repeat the login process. The only difference is that this time we select a different IP source address. Had this been a target that exports all target addresses, we would also select a different target address, but the iscsi redirect implementation on the PS100 makes this unnecessary. Alacritech Documentation 7

Now we are back at our target window, and it looks no different than it did after logging on the first time. Select the target again and hit the "Details" button. Alacritech Documentation 8

This opens the target properties pane. Now select the "Devices" tab and highlight one of the available devices. Alacritech Documentation 9

With a device highlighted, activate the "Advanced" button to bring up the "Device Details" pane. This pane should show the "Load Balance Policy" as "Fail over only", and should show one connection as active, and one as standby. Alacritech Documentation 10

Change the "Load Balance Policy" to "Round-Robin". All paths should immediately change to active, and your MPIO connection will now be fully functional. The bandwidth to target is now equal to the sum of the bandwidth of completely independent paths. In this example, we have two completely independent paths of one gigabit each, so the bandwidth to target is two gigabit. Had we more network interfaces available we could increase the bandwidth even further. Alacritech Documentation 11

If we now run the command netstat -nt we see that we have a connection from 192.168.50.105:2817 to 192.168.51.2:3260, and from 192.168.50.125:2819 to 192.168.51.4:3260, and that both connections are offloaded, indicating that everything is working as it should. Alacritech Documentation 12