How To Use A Detector 2



Similar documents
Technical Information

On-line Machine Condition Monitoring [The CMS System]

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Intelligent Vibration Monitoring

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Expat kiss_fft gsoap smartgwt Linux Qt md5 zlig log 4cpp sqlite gcc/g++/libc/libc++ gwt

Technical Data. FLIR T (incl. Wi-Fi)

Machinery condition monitoring software

TR Series Surface Roughness Tester for workshop and laboratory

Vibration Monitoring System Adash 3600

Manual Software for efector octavis. VES001 Version / / 2010

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Product Information Sheet UH36 Hi Pot Tester

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

VIBROCONTROL Sensitive Machine Monitoring

FAG Induction Heating Devices HEATER. Quality and Safety Redefined

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

Measuring electric and magnetic fields

Realtime FFT processing in Rohde & Schwarz receivers

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Alignment Laser System.

9000 Series Accelerometers Specifications

Nardalert S3 Non-Ionizing Radiation Monitor

SNC-VL10P Video Network Camera

Network analyzer and spectrum analyzer two in one

E420 SHAFT ALIGNMENT. Entry level measurement and alignment system for rotating machines BUILT-IN WIRELESS UNITS LARGE COLOUR DISPLAY QUICK START

New thermometers and accessories to grow your business

AM 300 Field Portable Leaf Area Meter. The World Wide Market Leader. World Class Precision. 40 years of experience in plant science

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

HD2030 [ GB ] Four channel vibration analyzer. Base screen: single axis measurements. Base screen: vector measurements.

Current Monitoring Kit QUICK START GUIDE

Selective and broadband low frequency field analysis

Ultrasound Condition Monitoring

Current Monitoring Kit

Frequency selective monitoring and logging of environmental electromagnetic fields

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Data Sheet FUJITSU Display L27T-1 LED Display

WXGA (1280 x 800), 3500 lumens, up to 7,000 hours lamp, HDMI, throw ratio, wireless ViewSync

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

How To Sell A Talan

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

GPRS/MMS/SMS Digital Infrared Trail Camera User s Manual WCM-3004

EFC Frequency converters

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

Data Sheet FUJITSU Display E19-7 LED

Field Service Application

GSM HOME SECURITY SYSTEM

CX380X Advanced Spectrum and Burst QAM Analyzer

Advanced Systems Tester 900AST

Product Overview 9100D

User and installation manual

NEW. EVEN MORE data acquisition and test stand automation

Field Service Application

Series 7500 Torque Sensor

Continuous, remote monitoring and logging of electromagnetic fields

LMS Test.Xpress Powering personal productivity

SONAPHONE. The New Device Class for Preventive Maintenance

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Analogue/Digital Analogue and Differential Oscilloscopes

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Technical Data FLIR E40bx (incl. Wi-Fi)

MultiViu Flex 7 Data Sheet

Data Sheet Fujitsu Display B19-7 LED Displays

Handheld Spectrum Analyzer

Series 6000 Torque measured metal bellow coupling

1 Technical Description Lokal-200PC

Industrial Balances PREMIUM Series 490 IBK/ITK/ISK

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

DSA800 Series Spectrum Analyzer

Online Infrared Flue Gas Analyzer Gasboard 3000

Ultrasonic Load Monitoring

Physical Specifications (Custom design available.)

Datenblatt - Fiche technique - Data sheet

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

DAB+ / FM Tuner Model: TU-201

Practical On-Line Vibration Monitoring for Papermachines

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Controls. LCD Display. Tuning Up Time Set and Station Scan

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

BLOOD COLLECTION MIXER

GSM COMMUNICATORS CATALOGUE

FREJA 300 Relay Testing System

Home alarm system. User s manual. Profile To better understand this product, please read the user s manual carefully before using.

Measurement Solutions for Refrigeration Technology.

R&S ZNC Vector Network Analyzer Specifications

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer with Color Alert

Transcription:

Technical Information TI No. WL 80-62 E January 2003 Detector II the mobile phone among the data collectors Maintenance Products

Application Condition-based maintenance Principle of operation Application The Detector II is a vibration measuring instrument and data collector rolled into one. Together with the PC software Trendline it was developed for measuring data in the offline monitoring of production plants. The Detector II is user friendly, very easy to operate and very light in weight. This makes the Detector II the ideal instrument for monitoring large production plants where long distances have to be covered on a measuring round. With this device users can determine vibration accelerations and vibration velocities in free definable frequency bands. Machine vibrations according to ISO 10816 can be monitored as well as the condition of rolling bearings with the principle of demodulation detection method. Moreover, raw signals and demodulated signals can be saved for more detailed analyses of the vibration signals in the time domain and in the frequency domain. Imbalances and faulty alignment can be detected as well as rolling bearing damage or gearing defects. In addition, the device features a separate temperature sensor. The device is also suitable for personnel without any knowledge of vibration measurement. Handling the device is uncomplicated and can be learned quickly. The user can generate individual measuring rounds and is then systematically guided from measuring point to measuring point. The acceleration sensor can be attached to the machine by means of its magnetic base. The user can at any time leave a previously specified measuring round and easily add additional measuring points on site. The data are measured and saved simply by pressing a key. Principle of operation The Detector II measures vibration signals at previously specified measuring points by means of a sensor and calculates the RMS values of vibration velocity, vibration acceleration and demodulated acceleration. These values, which characterise the condition of a machine or machine component, are described in more detail in the table on page 6. Frequency bands spanning 2 Hz to 20 khz with any desired frequency width and center frequency can be defined and monitored. The Detector II features a dynamic memory management unit; and the basic device FIS.DETECTORII.SET can save up to 24 time signals. With an expanded memory the FIS.DETECTORII.SET.1MB can save up to 116 time signals. With an infrared sensor plugged into the Detector II, the device can even be used for non-contact temperature measurements. After a measuring round the measured values are transferred to a computer where they are evaluated, analysed and graphically displayed by means of the Trendline software. Condition-based maintenance Condition-based maintenance means recognizing damage on time, having set schedules for repairs, optimally utilizing the life of a bearing, and reducing costs considerably in particular the costs resulting from production loss. The purchase cost of a diagnosis device, which is a must for this kind of maintenance, pays off in no time at all especially if you opt for the reasonably-priced, easy-to-operate and handy Detector II. FAG 3

Principle of operation User friendly The configuration contains the exact positions of the measuring points within the plant to be monitored. It also contains the sensor sensitivity and the threshold values for main alarm and pre-alarm for every measuring point. The configuration is generated by means of the Trendline software and transferred to the Detector prior to a measurement. The pickup sensor has to be securely attached as close as possible to the point to be monitored. As a rule, it is affixed by means of the screwed-on magnetic base. If this is not possible, e.g. with an aluminium housing, a small iron plate or washer with the size of the magnetic base is attached at the measuring point, for example by means of a hard-curing instant adhesive (e.g. cyanoacrylate adhesive). On the Detector II this measuring point is selected in the configuration, and the measurement is started. During the measurement the speed must be constant (at least 120 min -1 is required to determine the characteristic value for V sel and 600 min -1 to determine the characteristic value in accordance with ISO 10816). The device records the sensor signals within the previously selected bandwidths and calculates the characteristic values. For every configuration the Detector II compares the newly measured characteristic values with the threshold values for a main alarm and for a prealarm specified for this measuring point. If one of these threshold values is exceeded, this is indicated by the device. After a measuring campaign the saved values are transferred to the computer. By means of the trend analysis the user can estimate when an alarm is likely to be triggered. When an alarm is triggered, an alarm report can automatically be generated and printed. To ensure comparability of the values, they must be recorded under identical conditions. After a initial reference measurement, several measurements are conducted at regular intervals. E-mail button on the Detector II One particularly helpful feature of the software, especially for users with only little experience in the field of vibration measurement, is the e-mail button. The user simply sends at the touch of a button measured data to a vibration expert by e- mail. In this way an external diagnosis expert can be consulted in a simple manner for tricky analyses. Our F IS service department is always happy to help you with such analyses! User friendly The display of the Detector II shows all the information needed to operate the device: selection of the measuring point, user guidance during measurements, the measuring results, the system settings. The Detector is easy to operate, with just six keys of the foil keyboard. FAG 4

Features Order code and scope of delivery Features if you wish: you collect data, we make a remote diagnosis portable, handy, user friendly diagnosis device light weight (450 g) operation with one hand via 6 keys foil keyboard, protected from dust and splash water working temperature 0 to 50 C automatically switches off after ca. 2 minutes if no key is pressed monitoring functions: - general vibration condition, - rolling bearing condition, - data acquisition of up to 1200 measuring points, - headset jack for acoustic noise evaluation saving and display of up to 4 measuring values permits easy condition evaluation simple PC trend graphics software with database for WIN 95/98/NT/2000 sensor cable length up to 50 m possible Order code and scope of delivery Order code: FIS.DETECTORII.SET (Detector set with 256 kbyte RAM) or FIS.DETECTORII.SET.1MB (Detector set with 1 MByte RAM) DETECTOR II Scope of delivery: Basic device with storage battery Acceleration pickup with magnetic base Temperature sensor Power pack PC data cable Operating instructions Protective bag PC software Trendline Case Accessories Additional attachable bag for the acceleration pickup holder Sensor extension cables (5 m or 15 m) available on request. FAG 5

Selection of characteristic values Characteristic values and signals that can be Measuring range / resolution Frequency range Display on selected for every measuring point Characteristic value: vibration severity according to ISO 10816 ISO 10816 = 0 999.9 mm/s 10 Hz 1 khz Detector and PC (VDI 2056) (broadband RMS value of vibration velocity) for a general evaluation of the machine condition in accordance with ISO 10816 Characteristic value: vibration severity (freely selectable) V sel = 0 999.9 mm/s Freely selectable Detector and PC (RMS value of vibration velocity, e.g. for detecting imbalances between 2 Hz and and faulty alignment) 1 khz Characteristic value: acceleration A eff = 0 25 g 2 khz - 20 khz Detector and PC (broadband RMS value of vibration acceleration, e.g. for monitoring gears) Characteristic value: acceleration (freely selectable) A sel = 0 25 g Freely selectable Detector and PC (e.g. for selective monitoring of gearings) between 2 Hz and 20 khz Characteristic value: demodulated signal, 100 Hz/1000 Hz D eff/tp100/1000hz = 0 25 g 0 Hz 100 Hz/ Detector and PC (RMS value of the demodulated signal up to 100/ 1000 Hz, e.g. 0 Hz 1000 Hz for monitoring the rolling bearing condition) Characteristic value: demodulated signal D sel/tp100/1000hz = 0 25 g Freely selectable Detector and PC 100 Hz/1000 Hz (freely selectable) 0 Hz 100 Hz/ (e.g. for selective monitoring of the rolling bearing condition) 0 Hz 1000 Hz Time signal of vibration acceleration +/- 25 g 2 Hz to 1 khz PC up to 1 khz, 4096 values Time signal of vibration acceleration +/- 25 g 2 Hz to 20 khz PC up to 20 khz, 4096 values Demodulated signal +/- 25 g 0 Hz to 100 Hz PC up to 100 Hz, 0 Hz to 1 khz up to 1 khz Frequency spectrum (Fast Fourier Transformation, FFT) +/- 999.9 mm/s, 2 Hz to 1 khz PC of the time signal of the vibration velocity up to 1 khz Resolution: 0.73 Hz Frequency spectrum (Fast Fourier Transformation, FFT) +/- 25 g, 2 Hz to 20 khz PC of the time signal of the vibration acceleration up to 20 khz Resolution: 14.6 Hz Frequency spectrum (Fast Fourier Transformation, FFT) +/- 25 g, 0 Hz to 100 Hz PC of the time signal of the demodulated signal, optionally Resolution: or up to 100 Hz or up to 1 khz 0.073 Hz (for 100 Hz) 0 Hz to 1 khz 0.73 Hz (for 1 khz) Measuring point temperature Temp = - 15 C to 240 C -------------------------- Detector and PC On a PC the user can specify for every measuring point if, and under which conditions, certain time signals are to be saved as well. Three different time signals can be measured, i.e. vibration acceleration (2 Hz 1 khz, 3 khz scan rate), vibration acceleration (2 Hz 20 khz, 60 khz scan rate) and demodulated signal (0 Hz 100 Hz/1 khz; 300 Hz/3 khz scan rate). The Detector can save up to 24 time signals (basic device) or 116 time signals (with an expanded memory). FAG 6

Technical data Device designation Detector II, order code FIS.DETECTORII.SET with an expanded memory: FIS.DETECTORII.SET.1MB Dynamic random access memory max. 1200 measuring points without time signals, basic device: 256 kbyte, up to 24 time signals can be saved, with an expanded memory: 1 Mbyte, up to 116 time signals can be saved PC interface RS 232, baud rate: 38.2 kbps or 57.6 kbps Display illuminated graphics display (LCD), 128 x 64 pixels, dimensions: 55 x 33 mm Inputs BNC jack for ICP acceleration pickup, sensitivity [mv/g] can be adjusted as required, 9-pin jack for pyrometer (IR temperature sensor), 9-pin DIP jack with RS232 interface for supplied PC data cable, battery charger jack Output jack for headset with 3.5-mm jack plug (walkman), signal: envelope Detector languages switchable: German, English, French, Dutch, Italian, Turkish, Spanish, Portuguese, Swedish and Finnish, Please inquire about the availability of other languages Keyboard 6 soft keys Manual currently in German and English Power supply rechargeable NiMH storage batteries Operating time ca. 8 hours (continuous use) Temperature range 0... +50 C (working temperature) -20... +70 C (transport and storage temperature) Dimensions 230 x 70 x 45 mm (L x W x H) Mass (basic device) ca. 450 g Protective bag two compartments, black nylon, 2 transparent windows, openings with velcro fasteners, velcro holders for cable and sensor, carrying strap PC software (Trendline) runs under WINDOWS 95/98/NT/2000 - configuration of the Detector II via RS232 interface - hierarchic factory and measuring point manager, can also generate machine graphics - generation of as many measuring rounds on PC as required - integrated database for saving the measured values - graphic presentation of the measured values and their development, trend analysis and trend extrapolation - presentation of the recorded time signals - presentation of the FFT of the time signals - report generator for alarms and measured values - available in German and English, availability in other languages will be indicated on inquiry Temperature measurement IR temperature sensor, handheld device for non-contact temperature measurement, measuring range -15... +240 C (1 mv/ C/ F), spectral range 8 14 µm, smallest target 2.5 mm, distance ratio 4 : 1, plugs into DETECTOR II FAG 7

FAG Kugelfischer AG & Co. KG Industrial Bearings and Services Postfach 1260 D-97419 Schweinfurt Georg-Schäfer-Straße 30 D-97421 Schweinfurt Service-Hotline: Tel. +49 2407 9149-99 e-mail: support@fis-services.de www.fis-services.de FAG Detector II - the mobile phone among the data collectors Every care has been taken to ensure the correctness of the information contained in this publication but no liability can be accepted for any errors or omissions. We reserve the right to make changes which serve technical progress. by FAG 2003 This publication or parts thereof may not be reproduced without our permission. TI No. WL 80-62 E/97/01/03 Printed in Germany