INSTRUCTION MANUAL 2044-01 T1 TO RS422 INTERFACE



Similar documents
F2400 FOM II Series Fiber Optic Modem Technical Manual

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

TTL to RS232 Adapter User Guide

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

T-Extender E-Extender

Chapter 4 T1 Interface Card

MS900AC-B-LS User Information

3-4 SAS/SATA II HDD Canister Deluxe version

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams


ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Powerware Relay-Serial Card User s Guide

Transformer-coupled passive transmit path with a fixed insertion loss of approximately 1.0dB.

AS-801 Promotion-On- Hold Segregator. Version 2.10

Advantium 2 Plus Alarm

DK40 Datasheet & Hardware manual Version 2

Cable Pinouts. SRP I/O Module

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Hi5. HD-SDI/SDI To HDMI Video and Audio Converter User Manual. December 17, 2008 P/N For Hi5 Serial Number or Later

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

ASP-DTH. DVI & Audio to HDMI Converter. User Manual. Manual Number:

SATA and SAS Hard Drive Backplane

Unattended Answering Device Instruction Manual

HYDRA Z Owner s Manual

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

RIU-IP Remote IP Interface User Guide

Crow Limited Warranty. Print Version 017

T3 Mux M13 Multiplexer

2x1 DisplayPort KVM. EXT-DPKVM-241 User Manual.

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

PS 155 WIRELESS INTERCOM USER MANUAL

Model SRMD Setra Remote Monitoring Display

G.703 Fractional T1 Access Unit. User Guide

PagePac PAGEPAL V

Dolphin 9900 Mobile Computers

INSTRUCTION MANUAL. MCR1 Memory Card Reader 5/93. Copyright (c) 1993 Campbell Scientific, Inc.

Contents. Safety Warnings... 1

HA5. HDMI To HD-SDI/SDI Video and Audio Converter User Manual

DVI Audio to HDMI Adapter

LDG DTS-4/4R Desktop Coaxial Switch / Remote

BroadBand PowerShield. User Manual

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

New MINIMAG Magnetic Stripe Reader

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

DS2186. Transmit Line Interface FEATURES PIN ASSIGNMENT

Testing PCI/ISA & PCMCIA Serial Cards

Zetron Desktop Microphone Manual F

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

USER INSTRUCTIONS DESCRIPTION:

Flarm LED indicator. Version 1.1

Appendix D T1 Overview

24-Port Channelized E1/T1 Line Card Overview

BACnet Automation Interface Module (Network Version)

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

CMT6104 IDE Controller and Hard Drive Carrier utilitymodule User s Manual

Installation and Operation Guide for PD4100 Series Power Control Centers

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Bluetooth UART/RS232 Module

User Manual. Humidity-Temperature Chart Recorder. Model RH520

CAMPUS-RS CSU/DS-1 INTERFACE CARDS

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Usage, Installation, Warranty and Service Information

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

How To Install A Power Supply (Uplast) With A Battery Pack

Communication Unit 560CMU05 Data sheet

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

PS/2 Extender USER MANUAL.

Laser Barcode Scanner

Application Note. PCIEC-85 PCI Express Jumper. High Speed Designs in PCI Express Applications Generation GT/s

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

3 U CompactPCI Backplane with 4 Slots

Contents i. CNX MIDI Interface Expansion Card: CNXMIDI 0

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

RLH Single Channel T1 Fiber Link Card System

Magnetic Stripe Reader-Writer. Magnetic Stripe Reader-Writer. RS232 & USB-RS232 Interface Quickstart Manual

User Guide. DVI-D Fiber Optic Cable. DVI + Digital Audio to HDMI Converter. HDMI to DVI + Digital Audio Converter DVI-3510a.

Technical Information Jumpers, Connectors and Memory JXM7031 (7031-xxx) MicroATX Motherboard Dual Jasper Forest Processors

User Guide. HDMI Active Cable Extender. DVI-7370c

T1 Networking Made Easy

RIGtalk. Revision 5. Owner s Manual 2012.

GPS 35 USB. installation and quick start guide

2100 POS System User Guide

ASKING FOR ASSISTANCE

HARDWARE MANUAL. BrightSign HD120, HD220, HD1020. BrightSign, LLC Lark Ave., Suite 200 Los Gatos, CA

HagUsb USB to S/PDIF Converter

INSTRUCTION MANUAL MODEL PCD-88

Transcription:

INSTRUCTION MANUAL 044-0 T TO RS4 INTERFACE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form without the prior permission of Cross Technologies, Inc. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. In all correspondence with Cross Technologies, Inc., regarding this publication, please refer to 044-0-000. First Edition, JUNE 99 CROSS TECHNOLOGIES, INC. 0 SHILOH ROAD, ALPHARETTA, GEORGIA 0005 PHONE (0) -005 FAX (0) -94 web www.crosstechnologies.com e-mail info@crosstechnologies.com

INSTRUCTION MANUAL 044-0 T TO RS4 INTERFACE TABLE OF CONTENTS. Equipment Description.... Technical Specifications....0 Installation.... Controls and Indicators... PAGE. Mechanical.... Jumper Settings....4 Installation...4.0 Circuit Description... CROSS TECHNOLOGIES, INC. 0 SHILOH ROAD, ALPHARETTA, GEORGIA 0005 PHONE (0) -005 FAX (0) -94 web www.crosstechnologies.com e-mail info@crosstechnologies.com WARRANTY - The following warranty applies to all Cross Technologies products. All Cross Technologies products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies obligation under this warranty is limited to repairing or, at Cross Technologies option, replacing parts, subassemblies, or entire assemblies. Cross Technologies shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. 044-0 Manual Page /9/9

INSTRUCTION MANUAL 044-0-T TO RS4 INTERFACE. Equipment Description The 044-0-T To RS4 Interface goes in position,4,,or of a Wegener Model 0 or 5 mainframe or position of a Wegener Model 0 mainframe. The T Interface Card receives T data and converts it to RS4 clock and data and simultaneously receives RS4 clock and data and converts it to T data. Three jumper straps select line lengths from 0 to 55 feet. The unit provides BZS/AMI encoding and decoding. It connects to DSX- cross connects and the RS4 interface is compatible with Wegener data products.. Technical Specifications Inputs - T (per ANSI T.40),.544 Mb/s, impedance = 00 Ω RS4 clock and data, terminated impedance = 0 Ω Outputs - T (per ANSI T.40),.544 Mb/s, impedance = 00 Ω RS4 clock and data, terminated impedance = 0 Ω Other Connectors Mechanical Current.0 Installation RJ45 00 type PCB with piggy-back connector board. Board installs in even slots of a 0, 0, or 5 mainframe + 5VDC 0 milliamps FIGURE. 044-0 Front Panel. Controls and Indicators - Controls - None Indicators - DS, Red LED that lights on loss of T receive signal (turns red when 5 consecutive zeros have been detected; normal when a.5% ones density signal returns). Mechanical -The 044-0-T To RS4 Interface goes in position, 4,, or of a Wegener Model 0 or 5 mainframe or position of a Wegener Model 0 mainframe. See Figure... Jumper Settings - See Figure. and Table and Table 044-0 Manual Page /9/9

.4 Installation -The T Interface Card receives T data and converts it to RS4 clock and data and simultaneously receives RS4 clock and data and converts it to T data.. Set jumpers JP - JP5 as desired (see Figure. and Table and Table ). Install the 044-0-T To RS4 Interface in position, 4,, or of a Wegener Model 0 or 5 mainframe or position of a Wegener Model 0 mainframe. See Figure... The T input and output goes to J. The RS4 input goes to J4 and the RS4 output goes to J. 4. Figure. shows connections of the 044-0 with a T subcarrier modulator (0-9) and a T subcarrier demodulator (0-9). Figure.4 shows the cable between the RJ45 connector and the pin white connectors used in this setup. Figure.5 shows the 044-0 edge connections and a section of the Wegener 0 and 5 backplane. TABLE - JUMPER DESCRIPTION JP # Description Dot Non-dot Normal COMMENTS JP LEN 0 See Table OPERATE DOT LINE LENGTH SELECTION BIT 0 JP LEN See Table OPERATE NON LINE LENGTH SELECTION BIT JP LEN See Table OPERATE DOT LINE LENGTH SELECTION BIT JP4 T Receive Code BZS AMI NON Selects the coding format for the input (receive) data JP5 T Transmit Code BZS AMI NON Selects the coding format for the output (transmit) data TABLE - LENGTH SELECTION CHART OPTION SELECTED JP (LEN0) JP (LEN) JP (LEN) 0 - FEET DOT NON NON - FEET NON DOT DOT - 99 FEET NON DOT NON 99-5 FEET NON NON DOT 5-55 FEET NON NON NON NOT USED DOT DOT NON PCM-0 G.0 DOT DOT DOT FCC Part, Option A DOT NON DOT ANSI T.40 DOT NON NON JP JP JP JP4 JP5 U U DS U T IN / OUT J RS 4 OUT J RS 4 IN J4 FIGURE. 044-0 On-Card Jumpers and Controls 044-0 Manual Page 4 /9/9

0 FRONT 4 5 9 P. S. 0 REAR J4 J4 T PINS 5 TX RING 4 TX TIP RX RING RX TIP J45 J40 J0 J0 J0 POWER SUPPLY 044-0 T To RS4 Interface ( fits in even slots of a 0 mainframe) J4 T IN / OUT (J) RS 4 OUT (J) RS 4 IN (J4) RS4 PINS GND CLK B CLK A 5 RR/RTS B 4 RR/RTS A DATA B DATA A GND 0 FRONT P. S. RS4 PINS T PINS J0 J9 J J J4 J5 J J 4 POWER SUPPLY 044-0 T To RS4 Interface ( fits in slot of a 0 mainframe) T IN / OUT (J) RS 4 OUT (J) RS 4 IN (J4) FIGURE. - 044-0 MAINFRAME INTERFACE 044-0 Manual Page 5 /9/9

0 FRONT 4 5 9 P. S. 0 REAR MOD DATA T IN/OUT DEMOD DATA J4 J4 POWER SUPPLY J4 J45 J40 J0 J0 J0 RJ45 TO PIN WHITE CONN CABLE MOD CLK DEMOD CLK FIGURE. - 044-0 AND T SC MODULATOR (0-9) AND T SC DEMODULATOR (0-9) RJ45 DATA + DATA - PIN WHITE CLOCK + CLOCK - PIN WHITE FIGURE.4 - RJ45 CONNECTOR TO PIN WHITE CONNECTOR CABLE 044-0 Manual Page /9/9

044-0 CARD, TOP 0 MAINFRAME - LOOKING AT THE BACKPLANE FROM THE CONNECTOR SIDE B A J GROUND... +5 VOLTS... -5 VOLTS... GROUND... 4 5 9 0 4 5 +5 VOLTS -5 VOLTS 4 5 9 0 4 5 A 4 5 9 0 4 J J J9 J0 J J 4 5 9 0 J A 4 5 9 0 4 5 = GROUND CONNECTOR EQUIVALENTS J=J=J=J J=J=J=J J=J=J=J J=J=J=J J=J=J=J J=J=J=J J9=J9=J9=J9 A=A=A5=A A=A4=A=A FIGURE 4.0 CONNECTIONS FOR 044-0 CARD IN A 0 MAINFRAME IN SLOTS, 4,, OR. HWW //9 CONNECT0 044-0 Manual Page /9/9

.0 Circuit Description Block diagram - Figure.0 shows the block diagram for the 044-0. The 044-0-T To RS4 Interface receives T data and converts it to RS4 clock and data and simultaneously receives RS4 clock and data and converts it to T data. Three jumper straps (JP, JP, JP) select line lengths from 0 to 55 feet. The unit provides BZS/AMI encoding and decoding by selection of JP4 (receive side) and JP5 (transmit side). T data goes through transformer T into IC, U which provides the T processing necessary to provide RS4 clock and data which is output via U. RS4 data is received by U and sent to the T processing IC, U. The T data out of U goes to transformer T. U also lights red LED, DS when loss of signal is detected (alarms when 5 consecutive zeros have been detected; normal when a.5% ones density signal returns). TRANSFORMER U RS4 BALANCED DATA OUT J, PINS, T IN J, PINS, T OUT J, PINS 4,5 T T TRANSFORMER U TI INTERFACE IC U U RS4 BALANCED CLOCK OUT J, PINS, RS4 BALANCED DATA IN J4, PINS, U RS4 BALANCED CLOCK IN J4, PINS, FIGURE.0 MODEL 044-0-T TO RS4 INTERFACE BLOCK DIAGRAM 044-0 Manual Page /9/9