Liebert PPC Second Generation Power Distribution Cabinet



Similar documents
Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Liebert NXC from 10 to 200 kva

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Liebert PPC Precision Power Center

Model #: SMART2200CRMXL

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Power Management Module 2. Installation

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

BC Pro UPS System Standby UPS System

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

Eaton 93PM UPS Where aesthetics meet intelligence.

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Internet Office UPS System Standby UPS for PCs, workstations and more

Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager

DCIM Readiness on the Rise as Significant Data Center Capacity Remains Unused. A Research Report from the Experts in Business-Critical Continuity TM

Galaxy VM. Three-phase power protection. schneider-electric.com

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

Uninterruptible Power Supply

Protecting The Critical IT Infrastructure of the United States

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

CUSTOMER EXPERIENCE CENTER

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Applications. Remote Display Mounting Kits

Zenith Series MDU & RDU. Critical Power Distribution Units

APC 3Phase Power Distribution

Internet Office 500VA Tower Standby 120V UPS with USB port

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

TrueAlarm Fire Alarm Systems

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Enterprise Remote Monitoring

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Protecting Our Information, Protecting Our Resources

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Liebert. Liebert Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

Hospital IT and Facilities Special Report Top concerns in the hospital include budget, power requirements

How To Improve Energy Efficiency In Data Center Management

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

How To Make A Data Center More Efficient

IT White Paper. N + 1 Become Too Many + 1?

Harmonics in your electrical system

LIFE Technology Enabling Remote Service Delivery

Solution Analysis White Paper CHOOSING THE RIGHT UPS FOR SMALL AND MIDSIZE DATA CENTERS: A COST AND RELIABILITY COMPARISON

LIEBERT VNSA Installation Sheet

Power Meter Series 700

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

MAJORSINE Power Inverter

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

PX100 MBP with Configurable Distribution

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

The Effect of Regular, Skilled Preventive Maintenance on Critical Power System Reliability

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

Emerson Smart Firewall

How To Get The Most Out Of Your Data Center Service From Liebert

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Power Quality for Information Technology System

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Eaton 93PM UPS Efficient. Scalable. Innovative.

Power Distribution Considerations for Data Center Racks

Transcription:

Liebert PPC Second Generation Power Distribution Cabinet

Emerson Network Power Delivers The Packaged Power Solution Creating high quality power is a major step towards protecting the operation of a critical facility. But don t stop there. Once you ve created a better level of power, you need to make sure that it can be distributed properly to each piece of important equipment. Critical Power Distribution Made Easy This is why Emerson Network Power designed the Liebert PPC Second Generation to bring you a distribution system that will close the power delivery loop in your critical facility. The Liebert PPC offers the benefits of a custom-tailored power system, with the convenience and cost savings of a pre-packaged, factory-tested unit. Housed in a single, self-contained cabinet, it combines distribution, computer-grade grounding, isolation, and power monitoring to provide the protection your vital computer or communications equipment demands. Available in 15-225 capacity systems for raised floor applications and top-exit models, the Liebert PPC offers flexible expansion capabilities to fit growing sites. The 150,, 225, 300, 430 and 800 are available with Square D I-Line panelboard distribution which extend the Liebert PPC line giving you more flexibility and more capacity in one cabinet. A Proven System The packaged system approach of the Liebert PPC is convenient and space-saving, reducing installation time and cost compared to a conventional approach using multiple interconnected components. The Liebert PPC is built on a proven system design used in thousands of installations, and unlike one-of-a-kind, built-up distribution constructed at the site, it undergoes thorough factory testing as a complete system to assure reliable, consistent performance. The Liebert PPC Offers A Number Of Benefits: Reliability Improved Power Quality Results in optimum equipment operation, reducing downtime and extending service life. Computer-Grade Grounding The Liebert PPC automatically establishes a single point ground to meet major manufacturers recommendations and the requirements of the National Electric Code. Monitoring Built-in metering and alarm annunciation with communication capabilities to Liebert centralized monitoring. Flexibility Handles Non-Linear Loads Fully compatible with the non-linear loads and other electronic equipment. Expansion Capability Add-on panelboards, optional Liebert EXC and flexible cabling can be installed with minimal disruption to meet growing needs. Location Flexibility The unit can be easily relocated to protect your investment. UL and ULc Listed as a Complete System Meets safety requirements for fast, hasslefree inspection and building code approvals. Low Total Cost Of Ownership Space Savings Compact single cabinet conserves valuable floor space. Easy Installation Single input cable connection reduces installation time and cost. TP-1 Listed Isolation Transformer Provides increased efficiency. Liebert PPC - 430. 2

An All-In-One Power System All At An Affordable Price A Noticeable Improvement In Power Quality There are a number of integral features that allow Liebert PPC Second Generation to offer a higher quality level of electrical power for your critical applications: The main input breaker with low voltage shunt trip accessory provides primary transformer overcurrent protection, a power disconnecting means, and a method to interface with shutdown controls. Double-Shielded, copper, TP-1 Listed Isolation Transformer that provides higher efficiency than standard transformers. Supplemental transformer protection is provided by temperature sensors in each winding to alarm abnormally high winding temperature or shutdown unit before isolation damage. One or more, individually enclosed panelboards with panelboard main breaker and individual isolated neutral and ground busbars distribute power to the sensitive load equipment. conduit landings are provided for each output panelboard to accommodate the large number of dedicated branch circuits recommended for sensitive electronic loads. Oversized neutral components safely withstand neutral currents of at least 1.73 times full load currents. System shutdown controls, including manual restart, overtemperature shutdown and emergency power off, are included. Optional shielded output cables for each load reduce EMI and RFI. Liebert PPC - 150-225 Bottom Entry/Exit with two Square D 72 pole Panelboards. The Liebert PPC approach gives you an easily installed package a single power connection to the building wiring simplifies hook-up and reduces installation time and cost. Flexible cables can be specified in lengths and sizes to match sensitive electronic loads, making the system easy to relocate or expand. A choice of service access allows greater location flexibility and smaller installed footprint. And since the power source is right there in the room, it eliminates difficulties in establishing a proper ground. The system also eliminates potentially harmful harmonic neutral current from the building wiring system. 3

Designed From The Ground Up For Effective Power Distribution Several key features have allowed Emerson Network Power to build a packaged power distribution system that combines a high level of power quality effectiveness with a cost that is less than conventional built-up systems. Computer Grade Grounding The Liebert PPC Second Generation establishes a single point ground for the critical load. Power ground and computer ground points are identical minimizing ground-loop currents and common mode disturbances. Short output cables maintain the integrity of the isolation and conditioning. Secure Distribution And Circuit Identification Distribution panels are in the computer room which limits access to authorized personnel only. Each breaker has an adjacent identification tag for rapid circuit ID. Each output cable is labeled at each end with circuit number, length, type of receptacle and circuit identification. Non-Linear Load Compatibility The basic Liebert PPC is designed to accommodate moderate levels of harmonic currents. Where severe levels of harmonic currents are anticipated, a K-Factor transformer option for harmonic current cancellation is available. Optional System Enhancements A host of options enable you to design the Liebert packaged power system to your exact needs: A Liebert EXC can be placed adjacent to Liebert PPC, adding up to six additional panel boards. Transient voltage surge suppression (TVSS) is available for increased protection from damaging voltage surges. Very short interconnecting wiring provides superior surge clamping performance. K20 transformer safely withstands high harmonic currents associated with electronic loads without derating. Liebert PPC - 15-125 Bottom Entry/Exit with Square D 72 pole Panelboard. 4

System Monitoring Enhances Visibility and Performance Panelboard Monitoring The integral Current Plus Monitoring (CPM) optional display monitors the current and voltage of the panelboard. The display includes a monochrome LCD, power and alarm LEDs, audible alarm, and a silence push button. It provides true RMS measurements and battery backed memory. Monitored parameters include: Voltage - Line-to-Line Neutral Current Voltage Total Harmonic Current Total Harmonic Branch Circuit Monitoring Advanced monitoring is available through the optional Liebert Distribution Monitoring (LDMF) display. This option provides a large LCD screen that allows viewing of monitored information for the panelboard as well as each individual branch circuit breaker. Alarm data may be viewed from this display for up-to-date breaker status. It provides true RMS measurements and battery backed memory. Monitored parameters are the same as those for the CPM monitor, plus for each branch circuit: Phase current kw-hours kw Percent load Centralized Monitoring An optional Liebert SiteScan interface allows centralized monitoring of the Liebert PPC Second Generation. A Liebert IntelliSlot communications card may be installed to allow monitoring through a Building Management System (BMS). RJ-45 Ethernet and BACnet options are available. Voltage - Line-to-Line Neutral Current Voltage Total Harmonic Current Total Harmonic Voltage - Line-to-Neutral Ground Current Power Factor Distortion (THD) Crest Factor Voltage - Line-to-Neutral Ground Current Power Factor Distortion (THD) Crest Factor Central Monitoring Interface Liebert PPC are compatible with our Liebert SiteScan centralized monitoring systems, allowing single point monitoring and alarm of power conditions. These microprocessor-based systems provide historical data on room conditions for future requirement planning and troubleshooting. In addition, for communication of monitored parameters and alarm information to other monitoring systems. Liebert IntelliSlot SNMP/Web, Modbus over IP and Modbus 485 cards can also be used to enable cost-effective monitoring of a Liebert PPC by your facility or network monitoring system. Event Management And Reporting Liebert SiteScan Web will show you exactly where the problem is not some cryptic message that will leave you guessing. Events and alarms associated with a specific system, area or equipment selected in the navigation tree are displayed. This view allows you to monitor alarm or event information geographically, as well as to acknowledge events, sort events by category, actions and verify reporting actions. Data Analysis And Trend Reporting With Liebert SiteScan Web you get powerful tools to analyze data and use it to prevent specific problems from occurring again. The operator can view trends by using the navigation tree and selecting the trends button in the graphic window. Users can create custom trend data that consist of one or more multiple data points. 5

Raising The Standard Of Power In Non-Raised Floor Applications Liebert PPC - 800 Bottom and Top Entry/Exit. The innovative top-exit Liebert PPC Second Generation takes packaged power systems to new heights literally. By placing the input and output conduit connections at the top of the unit, the top-exit Liebert PPC brings the benefits of high quality packaged power systems to non-raised floor applications. What s more, the unit retains the normal bottom output cable exit for easy relocation and expansion flexibility. Added Flexibility Enables You To Bring Packaged Power To Even More Locations Ideal for conditioned grade power distribution in applications where there is no raised floor, the top-exit Liebert PPC brings the flexibility and space-saving benefits of a packaged power system to a variety of applications: Office areas LANS Laboratories High-tech manufacturing sites Process control rooms Medical imaging suites Grouped workstations High Efficiency Power Distribution In Far Less Space Compared to a conventional power distribution system built at the site and using multiple interconnected components, PPC UNIT SITE PLANNING the top-exit Liebert PPC DIMENSIONS provides a much smaller footprint, reduced installation time, less cost and easier service access. SW XFMR PS1 PS2 PPC 66" 68" Liebert PPC - 150-225. 104" Conventional System = 47.7 Sq. Ft. 80" PPC = 37.8 Sq. Ft. 6

Specifications 15 30 50 75 100 125 150 225 150 225 300 430 800 60 Hz Voltage* Circuit Breaker (Amps) 20, 25, 60 40, 50, 110 70, 80, Panelboard Poles Dimension (in) Std Opt** W D H or 72 or 72 or 72 84, 108 84, 108 84, 108 100, or 84, 108 125, 300 72 125, or 84, 108 175, 400 72 175, or 84, 108, 450 72, 250, 250, 350 300, 350 60 Hz with I-Line Panel Board Voltage* Circuit Breaker (Amps) 250 250 350 300 350 400 500 700 1000 1 Panel Board Weight (lbs) Heat BTU/HR 32 32 77 650 2500 32 32 77 750 4 32 32 77 850 6 32 32 77 1050 8150 32 32 77 1275 9900 32 32 77 1450 11500 N/A 44 32 77 1750 12500 N/A 44 32 77 2100 15500 N/A 44 32 77 2250 15800 Dimension (in) W D H Weight (lbs) : 15-225, 3-phase 3-phase, 3 wire plus ground 208,, or volts; 60 Hz 208, 380, 400 or 415 volts; 50 Hz (Transformerless system require 3-phase, 4W & G) 3-phase, 4 wire plus ground 120/208 volts; 60 Hz 120/208, 220/380, 230/400, or 240/415 volts; 50 Hz Transformer: TP1 Double-Shielded, all copper windings. Class H 220 C insulation. Voltage Adjustments: -10% to +5% of nominal in 2 1/2% increments Noise Attenuation: 120 db common mode Efficiency: 96 to 98.6% Ground: Single-point reference on separately derived systems. Distribution: Individually protected panelboards with plug-in or bolt-on breakers and optional flexible output cables. Cooling System: Convection Heat BTU/HR Square D I-Line 86 32 77 2250 14127 Square D I-Line 86 32 77 2 16987 Square D I-Line 86 32 77 2750 18684 Square D I-Line 86 32 77 3150 21119 Square D I-Line 104 32 77 3976 26511 Square D I-Line 172 32 77 8020 41388 50 Hz Voltage* 15 30 50 75 100 125 150 225 Circuit Breaker (Amps) 30 60 100 150 225, 250, 250 300 400 450 Top Exit Voltage* Panelboard Poles Dimension (mm) Weight (kg) Std Opt** W D H 54 42, 54 54 54 54 54 Circuit Breaker (Amps) 20, 25, 60 40, 50, 110 70, 80, 100, 25, 300 125, 75, 400 175,, 450, 250, 250, 350 300,350 Heat (kw) 810 810 1960 318 0.73 810 810 1960 363 1.35 810 810 1960 420 1.82 810 810 1960 522 2.39 810 810 1960 635 2.90 810 810 1960 715 3.37 N/A 1120 810 1960 862 3.66 N/A 1120 810 1960 1043 4.54 N/A 1120 810 1960 1111 4.63 Panelboard Poles Dimension (in) Std W D H Weight (kg) Heat BTU/HR 32 32 77 650 2500 32 32 77 750 4 32 32 77 850 6 32 32 77 1050 8150 32 32 77 1270 9900 32 32 77 1450 11500 44 32 77 1750 12500 44 32 77 2100 15500 44 32 77 2250 15800 Monitored Parameters: and output voltages;, neutral and ground currents; voltage THD; current THD, K-factor and crest factor; ; kw; Power factor; Percent load; kw-hrs; and Frequency. Alarm Conditions: over- and under-voltages; output overload; neutral and ground over currents; output voltage THD; transformers over temperature; frequency deviation; phase sequence error; phase loss; 5 customer specified alarm conditions. The standard output voltage is 208/120 volts, for 60 Hz units. *Other voltages available, consult factory. ** Models are 44 (112cm) wide. *** A maximum of eleven 250A frame or eight 400A LA frame or six A LI frame output breakers can be installed in a Square D I-Line panelboard. 800 has two Square D I-Line panelboards. 7

Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, a business of Emerson (NYSE:EMR), delivers software, hardware and services that maximize availability, capacity and efficiency for data centers, healthcare and industrial facilities. A trusted industry leader in smart infrastructure technologies, Emerson Network Power provides innovative data center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and uncompromised availability regardless of capacity demands. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.emersonnetworkpower.com Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX Contact@EmersonNetworkPower.com Emerson Network Power Caribbean and Latin America Office United States of America +1-954-984-3452 Phone Ask.Cala@Emerson.com liebert.com 24 x 7 Tech Support 800 222 5877 Phone 614 841 6755 (outside U.S.) EmersonNetworkPower.com While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2013 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Liebert is a registered trademark of the Liebert Corporation. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2013 Emerson Electric Co. SL-20194 (R8/13) Printed in USA