General Purpose ph/orp Sensors



Similar documents
General Purpose ph/orp Sensor

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

ENDURANCE Conductivity Sensors

For additional information, please visit our website at

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

Trace Dissolved Oxygen Sensor

Toroidal Conductivity Sensor

Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor

Dissolved Oxygen Sensors

Combination ph/redox (ORP) Sensors

Multi-Parameter Electrochemical / Optical Water Quality System

Sanitary and CIP Toroidal Sensor

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

PART 1 - INTRODUCTION...

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Digital inductive conductivity transmitter

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Rosemount 1199 Submersible Seal

Baumann Way Bronze or Stainless Steel Control Valve

Rosemount 1199 Submersible Seal

Baumann Flexsleev Sanitary Control Valve

Monitoring Water Quality For Today s Demanding World

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

The Theory of ph Measurement

Instruction Manual PN /rev.E March 2010 Model 381. ph/orp Sensor

Sanitary Type Electronic Flow Switches

Galvanic Parts Per Million Dissolved Oxygen Systems

Electronic Flow Switches

Turbine Flowmeters for Gas Applications

Baumann Little Scotty Bronze Control Valve

SITRANS F flowmeters SITRANS F M

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

CONDUCTIVITY, ph/orp, & AMPEROMETRIC HART ANALYZERS/CONTROLLERS

In-Line Electronic Flow Switches

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Self Purging Liquid Trap (SPLT ) User s Manual

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

WEL Series ph/orp ELECTRODES

Low Frequency Velocity Sensor

Commercial Gas Water Heaters

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Automation & Sanitization REPLACEMENT PARTS

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Stainless Steel Valves For the Sanitary Industries

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Fisher 657 and 667 Diaphragm Actuators

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

The Unique Accelabar Flow Meter

Instruction Manual LIQ-MAN-5081P/rev.J January Model 5081-P. Two-Wire ph/orp Transmitter

B150 Series Commercial Brewer. Direct Plumb Kit

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

Block and Bleed Gauge Valves M25 and M251

Micro Motion 3098 Gas Specific Gravity Meter

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

How To Use A Flowmeter

ExStik TM ph Waterproof Meters

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Installing a Probe. Typical Installation

Typical Aluminum GFM Mass Flow Meter

Rosemount 333 HART Tri-Loop

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

167D Series Switching Valves

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Fisher 377 Trip Valve

Analytical Service Certification Program

Model 111 Mass Flow Instruments

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Copper Meter Resetters

F9MXE. Product Specifications

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

DissolvedOxygenMonitor

Rosemount 333 HART Tri-Loop

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

Models SFP33 & SFP32 Pressure Transmitters

Analytical Sensors. Comprehensive Liquid Analysis Sensors Optimized for Pure Water Treatment. THORNTON Leading Pure Water Analytics

Powers Controls TH 192 S Single Temperature Room Thermostat

Baumann 24000SB Barstock Control Valve

In-Line Electronic Flow Switches

G9MXE. Product Specifications

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Your safety and the safety of others are very important.

Transcription:

General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double junction reference. Enhanced performance and increased life with minimized glass cracking provided by field-proven AccuGlass ph glass formulations. VP8 quick cable-to-sensor release, provided by the watertight VP8 multiple-pin connector, eliminates cable twisting. Maximum chemical resistance provided by rugged polyphenylene sulfide body, completely sealed to eliminate sensor leakage. NEW 3/4 and 1 mounting solutions to meet a variety of application installation requirements. Optimum versatility with various mounting options provided by one-piece construction with process threads in two places. Operates in sub-zero temperatures down to -10 C (14 F). Responds to changes in ph at a minimum conductivity of 0.1mS/cm when used with the low flow cell panel. 3900 Insertion/Submersion Sensor Features and Applications General purpose ph/orp 3900/3900VP sensor. The double junction reference aids in the sensor s resistance to harsh environments and helps prolong sensor life. The 3900 and 3900VP are provided with a double junction reference, which protects the reference element from poisoning ions such as ammonia, chlorine, cyanides, and sulfides in the process. Both models are made with porous Teflon junction positioned near the ph/ ORP-sensitive membrane. The SMART preamplifier option becomes enabled when used with the 56, 1056, 1057 analyzers and on the 6081P wireless transmitter. The ph-loop capabilities include auto-recognition of the SMART sensor, automatic upload of calibration data and associated time stamp, historical recording of ph diagnostics (slope, offset, reference impedance, glass impedance). This trending data allows technicians to predict frequency of maintenance and estimate sensor life for a particular process condition. Additional SMART features include factory calibration, resetting SMART sensor calibration data, user menus, and manufacturing information. The AccuGlass ph glass formulations exceed industry standards. The AccuGlass ph glass is a result of many years of glass research resulting in a formulation which has been found to increase the life of the sensor. Unlike other ph glasses presently on the market, this glass resists cracking especially at higher temperatures and reduces sodium ion error commonly found in high ph applications. Overall, the AccuGlass formulation enhances the sensor performance to measure ph more accurately and have a longer sensor life than ever before.

General Purpose ph/orp Sensors December 2014 Features and Applications (cont.) The 3900VP is offered with a watertight sensor-to-cable connector which eliminates re-wiring and cable twisting when replacing sensors. The Variopol VP multiple pin connector is an integral part of each sensor model and uses a mating VP cable. Once the cable is installed and wired to the analyzer, sensors are easily replaced without replacing the cable and without rewiring the analyzer. Also the cable can be disconnected from the sensor before removal from the process which eliminates cable twisting. The 3900 and 3900VP are housed in a molded PPS body, making each sensor virtually indestructible and chemically resistant. Complete encapsulation eliminates leakage or high humidity problems traditionally found in other ph/orp designs. The simplified construction, designed with user convenience in mind does not require electrolyte (KCl) replenishment or any high maintenance troubleshooting procedures. Installation is easily achieved through the wide variety of mounting configurations. Both models feature 1 and ¾ inch (MNPT) front facing connections for insertion, submersion, or flow-through ph and ORP applications. Both models are combination sensors (ph, reference, and temperature within sensor body) and measure ph or ORP (Oxidation/Reduction Potential) of aqueous solutions in pipelines, open tanks, or ponds. The 3900 and 3900VP are suitable for virtually all applications and are compatible with Rosemount Analytical and other manufacturers instruments. Physical Performance and Specifications Sensor Type: General purpose 3900 Measured Range: ph: AccuGlass 0-14 ORP: -1500 to +1500 mv Percent Linearity Over ph Range: Range Operating Temperature: -10 to 100 C (14 to 212 F) Automatic temperature compensation -10 to 100 C (14 to 212 F) Maximum Pressure: 790 kpa [abs] (100 psig) at 100 C (212 F) CRN rating: 60 psig up to 100 C (212 F). Materials of Construction: stainless steel, glass, Teflon, polyphenylene sulfide (PPS), EPDM and silicone Conductivity: Responds to changes in ph at a minimum conductivity of 0.1mS/cm when used with the low flow cell panel. The sample flow rate must be controlled to 2gph (7.6L/hr). Materials of ORP: Platinum Process Connections: Front facing: 3/4 and 1 MNPT Rear facing: 1 MNPT Integral Cable: 32 ft (10m) cable with integral preamp; 15 ft (4.7m) cable without preamp sensor VP8 Cable: use 24281-XX, 2.5 ft (.8m) to 100 ft (31m) Weight/Shipping Weight: 0.45 kg/0.9 kg (1 lb/2 lb) Hazardous Location Approvals: Linearity 0-7 97% 1-7 98% 4-7 98% 7-10 99% 7-12 97% 7-13 96% 7-14 95% 2 RosemountAnalytical.com

December 2014 General Purpose ph/orp Sensors Dimensional drawing for the 3900 and 3900VP 3900 3900VP RosemountAnalytical.com 3

General Purpose ph/orp Sensors December 2014 Installations and Accessories Specifications Typical Flow Through insertion installation using PN 2002011 Pipe Tee (sensor must be installed at least 10 above the horizon) Horizontal Pipe Tee (PN 2002011) Pressure/Temperature Ratings psig (kpa [abs]) F ( C) 150 (1136) 150 (65) 128 (984) 160 (71) 102 (805) 170 (77) 80 (653) 180 (82) 57 (494) 200 (93) 48 (432) 210 (99) Low Flow Cell PN 24091-00 Inlet and outlet connections are stainless steel and take 1/4-inch OD tubing. Flow cell is polycarbonate with 1/4-inch FNPT fittings. MILLIMETER INCH WETTED MATERIALS: BODY & NUT - POLYESTER/ POLYCARBONATE FITTINGS - 316 SST SEALS - SILICONE FLOW CELL RATINGS TEMPERATURE: 32-158 F (0-70 C) MAX. PRESSURE: 90 PSIG (721 kpa [abs]) FLOW RATE: 2-5 GPH (7.6-18.9 LPH) Flow-through tee (2 inch) (PN 915240-03, -04, -05) The following Flow-through Tee s are available for the 3900: 915240-03 915240-04 915240-05. For a new installation use the appropriate tee (915240-xx) and add the S10283-LQD adapter. When replacing an existing 399 with a 3900 sensor, add the S10283-LQD adapter to convert the tee to accept the 3900 sensor. MILLIMETER INCH Adapter 4 RosemountAnalytical.com

December 2014 General Purpose ph/orp Sensors Jet Spray Cleaner PN 12707-00 The Jet Spray Cleaner eliminates routine, manual sensor maintenance by cleaning the sensor with water or compressed air. Flow through the cleaner can be controlled by a solenoid valve. Jet Spray Cleaner shown with 3900VP ph sensor NOTE: The Jet Spray Cleaner can be used with Handrail Mounting Assembly (PN 11275-01, not shown) or can be mounted through conduit as shown above. Low Flow Panel PN SQP10077-LQD Low Flow Panel Specifications Inlet flow Inlet pressure Temperature 3-80 gph (11.4-304 L/hr) 3 65 psig (122 549 kpa abs)* 32-122 F (0-50 C) *The minimum inlet pressure is required to open a check valve, which prevents the flow cell from draining if sample flow is lost. Removing the check valve lowers the inlet pressure requirement to a few feet of water head. RosemountAnalytical.com 5

General Purpose ph/orp Sensors December 2014 3900/3900VP ph/orp Sensor The 3900/3900VP ph/orp Sensor is housed in a PSS plastic body with built-in solution ground for advanced diagnostics. A Pt-100 RTD is offered for temperature compensator. The sensor is available with an integral cable or VP8 connector. Integral preamplifier (-01) is the standard SMART preamplifier option, and is compatible with the XMT, 56, 5081, 6081, 54e and 1056 analyzers/transmitters. Junction box kits with preamplifiers can be ordered separately if an analyzer/ transmitter with an integral preamplifier is not located within 15 ft. of the sensor. 3900 ph/orp Sensor - New Generation general purpose sensor CODE Preamplifier Option 01 SMART Preamplifier, 32 cable 02 No preamplifier, 15 cable Code Measuring Electrode 10 General Purpose Low resistivity GPLR ph Glass (0-14pH) 12 Platinum ORP Example 3900-01- 12 3900VP ph/orp Sensor - New Generation general purpose sensor with VP CODE Preamplifier option 01 *SMART Preamplifier 02 No preamplifier CODE Measuring Electrode 10 General Purpose Low resistivity (GPLR) ph Glass (0-14pH) 12 Platinum ORP Example 3900-02- 10 * A mating VP connector cable is required for all first time installations of 3900VP sensors. See accessories listing on next page. 3900VP Insertion/Submersion Sensor with VP connector and mating VP cable 6 RosemountAnalytical.com

December 2014 General Purpose ph/orp Sensors Accessories Other Accessories Part Number VP Connector Cables-Use for 1st time Installation of a 3900 VP Sensor 24281-00 15 ft. cable with mating VP8 connector 24281-01 25 ft. cable with mating VP8 connector 24281-02 2.5 ft. cable with mating VP8 connector 24281-03 50 ft. cable with mating VP8 connector 24281-04 100 ft. cable with mating VP8 connector 24281-05 4 ft. cable with mating VP8 connector 24281-06 10 ft. cable with mating VP8 connector 24281-07 20 ft. cable with mating VP8 connector 24281-08 30 ft. cable with mating VP8 connector Mounting Accessories 12707-00 Jet Spray Cleaner 23242-02 Insertion adapter 24091-00 Low flow cell 23555-00 Junction Box with Preamplifier for the 54e, 3081, 4081, 5081, XMT, 1055, 1056 2002011 CPVC flow through Tee, 1-1/2 in. NPT process connection 11275-01 Sensor handrail assembly 9200273 Extension cable, gray 9200348 Extension cable, blue 915240-03 PVC flow through Tee, 3/4 in. NPT process connection 915240-04 PVC flow through Tee, 1 in. NPT process connection 915240-05 PVC flow through Tee, 1-1/2 in. NPT process connection Calibration Accessories 9210012 Buffer solution, 4.01 ph, 16oz 9210013 Buffer solution, 6.86 ph, 16oz 9210014 Buffer solution, 9.18 ph, 16oz R508-8oz. ORP solution, 460mV ±10 @ 20 C SQP10077-LQD Low Flow Control Panel RosemountAnalytical.com 7

LIQ_PDS_3900 Rev. F December 2014 facebook.com/emersonrosemountanalytical AnalyticExpert.com twitter.com/raihome youtube.com/user/rosemountanalytical 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 RosemountAnalytical.com 2014 Rosemount Analytical, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.