The compact unit series



Similar documents
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

ECOCIAT. Domestic hot water heat recovery unit

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

squrboxbox heat recovery squrboxbox I technical information

CRAC Precision climate control units for data centres

Comparison between Decentralised and Centralised Air Conditioning Systems

RPV - RP - RA air handling units

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

LG Electronics AE Company, Commercial Air Conditioning

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Under sill units. Type FSL-B-ZAS

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Combi Unit Genius. The energy efficient Building Service Centre

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

How To Get A Passive House

You make dreams a reality. We provide the efficient Air-Conditioning.

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

york air-conditioning products Residential & VRF News 2015

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Rotary screw compressors kw 5,5 7, , bar MODULO

HEATER, AIR CONDITIONING AND VENTILATION

Cooling kw Heating kw

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Operation and Installation Manual. Max Series

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

UDSA - UDSBD unit heater

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Weiss Mobile Air Conditioning Systems

Compact. Efficient. TROX.

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

FULL DC INVERTER SYSTEMS

KONRAD. Hybrid Fancoil Series

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

FLEXIT S4 R S6 R S7 R

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Test Report issued under the responsibility of:

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

HDA

CE6500 Energy Recovery Ventilator

Flexit air handling unit K2 R

Split units TH with hermetic compressors

Zehnder Focus 200. Ventilation device

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

PLUG and PLAY VRV Connection

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

Cooking at the Speed of light!

Commercial Gas Furnace Upflow

Material test chamber with mechanical convection

SECTION MORTUARY REFRIGERATORS

CADB and CADT-D / DI / DC Series

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06

HERZ-Thermal Actuators

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Bring the fresh in. Dedicated Outside Air Systems

Topvex SX/C, Topvex TX/C. Air Handling Unit

ABB i-bus KNX Fan Coil Controller FC/S 1.1

We have been working in an ideal climate for thirty years.

Heat Recovery based on Exhaust Air

All the best brands all under one roof

ROTARY SCREW COMPRESSOR. RMD kw

Condensing unit type EPSILON-ECHOS LE Technical information manual

Air-water systems for efficient air conditioning

Lesson 36 Selection Of Air Conditioning Systems

RRV934. Multi-controller. Synco living

ThermoStar Refrigeration Air Dryers

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

Smile. The All-In-One Heating Controller

AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET

High-efficient gas boiler CompactGas

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

lindab we simplify construction Air Handling Units Product Overview

Electronic Control Devices The European Product Catalogue 2007

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

HEAVY DUTY STORAGE GAS

Installation and maintenance instructions. Danfoss Vent

Screw Compressors ESM Fixed Speed & VS Variable Speed

HP switch LP switch Discharge thermo Comp. Surface thermo

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Half the cost Half the carbon

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Chilled Water Precision Air Conditioner For Critical Application

94122E FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

Transcription:

The compact unit series

The easy way to maintain a good climate i High, efficient energy recovery with an efficiency of 80 90 % i Energy-saving fan motors utilising EC technology for minimal energy consumption i Noise reduction by utilising sound-absorbing casings and optimally designed components i Easy operation by using state of the art controlling systems i High quality manufacturing, easy to install, reduced maintenance costs i Designed in accordance to VDI 6022 The EASYAIR air handling units are equipped with a highly efficient energy recovery system. The air handling units guarantee an efficiency of 80 90 % in accordance with the European Guideline DIN EN 308. The components are specifically designed to optimise efficiency. The aerodynamic efficient arrangement of the components combined with reduced pressure losses on the air side and the fans with modern EC drive technology, enable an extremely energy saving operation throughout the year. The intelligent control system of the EASYAIR is easy to handle. The control unit manages the energy-optimised operation of all components. The complete unit is delivered as a plug-in system, no wiring installation work, just conncet for power (and often cooling and heating medium) and EASYAIR can be started immediately. EASYAIR can be chosen within air volume ranges from 650 to 13.000 m³/h (different sizes). By using these components in addition to the high quality casing of the unit it is possible to reduce acoustic emissions significantly. 2

External VRF unit (LG) I Cooling function in Summer I Heat-pump function in Winter I Built-in, internal direct evaporator I External inverter unit I Inverter control unit is integrated in the EASYAIR control system. Monovalent cold and heat supply for air processing AL-KO THERM GMBH cooperates closely with LG Electronics to efficiently develop a soft and hardware solution in order to assist a rapid start-up of the airhandling-system as well as a trouble-free operation of the unit. AL-KO supplies the product as a complete package (including start-up-service). 3

Performance data Rotary heat exchanger (thermal wheel) Silencer-module outdoor air and waste air as a complete unit Silencer-module extract air and supply air as a complete unit Heating-module WWE Electric heating-module ELE waste air extract air Height Heating-cooling module WKE Evaporator-module WDV supply air outdoor air H* SD A B C SD 229 Length 765 * Equipment stands option (50 120 mm) technical data Rotary heat exchanger Type Air volume 1 (m 3 /h) / efficiency 2 (%) / Sound power level 3 (db(a)) SFP 4 SA/RA Length 5 Width 6 Height min nominal max W/m³ s mm mm mm RO-01 650 / 90 / 79 1.350 / 82 / 82 1.700 / 79 / 85 954 / 824 1.530 712 953 RO-02 1.000 / 90 / 81 2.000 / 83 / 81 2.600 / 79 / 83 867 / 652 1.530 865 1.259 RO-03 1.500 / 90 / 80 3.000 / 82 / 82 3.800 / 79 / 84 764 / 603 1.530 1.018 1.259 RO-04 2.000 / 90 / 79 4.000 / 83 / 86 5.100 / 79 / 89 694 / 561 1.683 1.171 1.565 RO-05 2.700 / 90 / 81 5.400 / 82 / 88 6.500 / 80 / 92 724 / 574 1.683 1.324 1.565 RO-06 3.300 / 88 / 83 6.300 / 80 / 90 7.500 / 78 / 89 737 / 649 1.683 1.324 2.177 RO-07 4.200 / 90 / 86 8.400 / 82 / 87 10.200 / 80 / 91 747 / 598 1.989 1.630 1.871 RO-08 5.000 / 88 / 84 10.000 / 80 / 90 11.000 / 77 / 90 780 / 679 2.142 1.630 2.177 RO-09 6.000 / 90 / 88 12.000 / 82 / 89 13.000 / 81 / 92 681 / 579 2.142 1.936 2.177 Plate heat-exchanger Type Air volume 1 (m 3 /h) / efficiency 2 (%) / Sound power level 3 (db(a)) SFP 4 SA/RA Lenght 5 Width 6 Height min nominal max W/m³ s mm mm mm PL-01 650 / 85 / 78 1.350 / 82 / 82 1.700 / 81 / 85 925 / 737 2.066 712 953 PL-02 1.000 / 85 / 78 2.000 / 82 / 81 2.500 / 81 / 83 780 / 581 2.066 1.018 953 PL-03 1.500 / 85 / 78 3.000 / 82 / 85 3.700 / 82 / 87 784 / 656 2.372 1.018 1.259 PL-04 2.000 / 85 / 78 4.000 / 82 / 86 5.000 / 82 / 87 748 / 608 2.525 1.324 1.259 PL-05 2.500 / 85 / 79 5.000 / 82 / 87 6.200 / 82 / 91 748 / 608 2.601 1.630 1.259 1 External pressure loss; supply air 300 Pa, exhaust air 250 Pa 2 Efficiency of heat recovery according to DIN EN 308 (without condensation) 3 Sound power levels in the supply air duct with dampers 4 Specific Fan Power (SFP) in accordance with EnEV 2009 at a nominal air volume and external duct pressure losses; supply air 300 Pa, exhaust air 250 Pa, incl. dampers and filters (F7 / F5) 4 To get current, detailed technical data please use EASYAIRselect: http://easyair.al-ko.de

Plate-heat exchanger (counter-flow) waste air Silencer-module outdoor air and waste air as a complete unit Silencer-module extract air and supply air as a complete unit extract air Heating-module WWE Electric heating-module ELE Height outdoor air Heating-cooling module WKE Evaporator-module WDV supply air H* SD A B C SD 229 Length 765 * Equipment stands option (50 120 mm) A 7 B 7 C 7 Duct connection (mm) 5 Weight Max. connection power mm mm mm Length Height kg kw A 8,9 - - - 612 306 307 3,1 6,9 - - - 765 459 378 2,1 6,7 - - - 918 459 448 4,2 8,5 735 383 658 1.071 612 640 6,9 12,5 735 383 658 1.224 612 705 6,9 12,5 735 383 658 1.224 918 815 6,9 12,5 868 536 791 1.530 765 1.008 9,7 16,5 944 536 868 1.530 918 1.133 9,7 16,5 944 536 868 1.836 918 1.280 10,4 17,5 A 7 B 7 C 7 Duct connection (mm) 5 Weight Max. connection power mm mm mm Length Height kg kw A 8,9 612 306 365 3,1 6,9 918 306 428 3,1 6,9 918 459 556 4,2 8,5 612 1.378 573 1.224 459 730 4,2 8,5 689 1.378 573 1.530 459 846 7,2 12,9 5 With duct connections (option), the unit length increases on both sides by approx. 65 mm 6 Additional width for repair switch 80 mm (detachable during transport) 7 max. Module dimensions for unit in split execution (for installation purposes) 8 Power supply 3 400 V, 50 Hz 9 Without power for optional electric air heater 5

Performance data Rotary heat exchanger (thermal wheel) Silencer-module outdoor air and waste air as a complete unit Silencer-module extract air and supply air as a complete unit Heating-module WWE Electric heating-module ELE waste air extract air Height Heating-cooling module WKE Evaporator-module WDV supply air outdoor air H* SD A B C SD 229 Length 765 * Equipment stands option (50 120 mm) technical data Rotary heat exchanger (options) Type Sound absorber (SD) long Sound absorber (SD) short Length (mm) 10 damping (db) 11 Weight (kg) 12 Length (mm) 10 damping (db) 11 Weight (kg) 12 RO-01 1.377 30 245 765 17 166 RO-02 1.377 30 257 765 17 176 RO-03 1.377 30 284 765 17 193 RO-04 1.683 36 492 1.071 24 339 RO-05 1.683 36 520 1.071 24 364 RO-06 1.989 43 674 1.071 24 404 RO-07 1.989 43 742 1.071 24 434 RO-08 1.683 36 702 1.071 24 476 RO-09 1.989 43 1.006 1.377 30 770 Plate heat-exchanger (options) Type Sound absorber (SD) long Sound absorber (SD) short Length (mm) 10 damping (db) 11 Weight (kg) 12 Length (mm) 10 damping (db) 11 Weight (kg) 12 PL-01 1.377 30 245 765 17 166 PL-02 1.377 30 257 765 17 176 PL-03 1.377 30 284 765 17 193 PL-04 1.377 30 334 765 17 234 PL-05 1.989 43 588 1.071 24 356 10 additional length with silencer-module 11 built-in silencer to suit frequency 250 Hz 12 additional weight; only for silencer-module 13 Power supply 3 400 V, 50 Hz 6 To get current, detailed technical data please use EASYAIRselect: http://easyair.al-ko.de

Plate-heat exchanger (counter-flow) waste air Silencer-module outdoor air and waste air as a complete unit Silencer-module extract air and supply air as a complete unit extract air Heating-module WWE Electric heating-module ELE Height outdoor air Heating-cooling module WKE Evaporator-module WDV supply air H* SD A B C SD 229 Length 765 * Equipment stands option (50 120 mm) ELE WWE WKE WDV kw (heating) A 13 kw 14 (heating) kw 15 (cooling) kw 14 (heating) kw 16 (cooling) kw 17 (heating) 3,0 4,5 2,8 4,5 2,8 4,5 6,5 4,0 6,8 4,0 8,1 5,4 7,0 10,1 6,2 10,2 6,2 13,1 8,0 9,0 13,0 8,2 13,8 8,2 18,2 10,7 12,0 17,3 11,0 18,2 11,0 23,4 14,5 15,0 21,7 14,5 21,5 14,5 29,8 16,9 17,2 28,4 17,2 37,9 22,5 23,6 34,6 23,6 45,6 26,8 24,7 40,9 24,7 47,5 32,2 ELE WWE WKE WDV kw (heating) A 13 kw 14 (heating) kw 15 (cooling) kw 14 (heating) kw 16 (cooling) kw 17 (heating) 3,0 4,5 2,8 4,5 2,8 4,5 6,5 4,0 6,8 4,0 8,1 5,4 7,0 10,1 6,2 10,2 6,2 13,1 8,0 9,0 13,0 8,2 13,8 8,2 18,2 10,7 11,6 16,7 10,5 17,1 10,5 23,4 14,5 14 Heating performance during warming, up to 6 K, Medium 50/35 C 15 Cooling performance, with 10 K air-cooling (from 27 C to 17 C) 16 Cooling performance with 9 K air-cooling 17 Heating performance during warming up to 8 K Medium 6 / 12 C 7

Unit design and options EnEV 2009 (Energy Saving Regulation) EASYAIR air handling units are manufactured and designed in accordance with the European Guideline EnEV 2009. It must also be highlighted that, as a result of the high efficiency of the heat recovery (80 90 %), achieved from the energy efficient motor technology for the fans and due to the intelligent control of all components, all EASYAIR air handling units are far superior to the current requirements as laid down in EnEV 2009. VDI 6022 (hygienic requirements) All EASYAIR air handling units are manufactured and designed according to the European Guideline VDI 6022. The casings of all EASYAIR air handling units are powder-coated on both sides. Other components are made from galvanized steel. All EASYAIR air handling units provide easy access for any possible service and maintenance works in accordance with VDI 6022. Heat recovery A choice can be made between rotary (thermal wheel) or plate heat exchanger-units. Rotary heat exchangers are preferred when recirculating air operation is possible. To prevent cross-flow contamination between supply and exhaust air, the use of plate heat exchangers is recommended. I RO- = with Rotary heat exchanger I PL- = with Plate heat exchanger Equipment stands All the EASYAIR air units can be ordered with practical, individual stands which allow the units to be adjusted to each and every situation. The EASYAIR unit can therefore be correctly assembled in most situations, even when the sub-surface is not ideal. I RO- = with rotary, heat-exchanger without a stand I RC- = with rotary, heat-exchanger with a stand I PL- = with a plate, heat-exchanger without a stand I PC- = with a plate, heat-exchanger with a stand Unit sizes Both types of heat recovery units are available in various sizes. For each size as well as their optimized air volumes, please refer to pages 4 and 5. I RO-04 = Size 04, for air volumes between 2.000 and 5.100 m³/h. Sample for selection is done by choosing an EASYAIR with rotary heat-exchanger (RO-), size 04 (RO-04). Service side Of course, it can be chosen where the service side of the EASYAIR should be located so that easy access is ensured for maintenance and service. The location of the service side is always based on the direction of the supply air. The service side in the right hand, supply air direction conforms to the illustration shown on pages 4 and 5 (f. e.). I RO-04-R = Service side in supply air direction right I RO-04-L = Service side in supply air direction left Splitted design / outdoor design For unit size 04, there is the possibility to order EASYAIR in a split design. Thus, the air handling unit can be installed very easily, even e.g. when the access openings (building doors) are limited in width or height. Please refer to the dimension table on pages 4/5 and 6/ 7. All EASYAIR units can be ordered for outdoor installation as weatherproof units. Weatherproof units are only available as one-part units and have a weatherproof roof with drip tray. As an option, weatherproof units are available with an intake and extract hood. I RO-04-R-X = Casing in non-split design I RO-04-R-T = Casing in split design I RO-04-R-W = Casing for outdoor installation I RO-04-R-H = Casing for outdoor installation with an intake and extract hood Filter classes As standard, the EASYAIR is supplied with highly efficient air filters. In the supply air there is a F7 and in the exhaust air there is a F5 filter installed. The quality of the filters are according to VDI 6022. 8

I RO-04-R-X-75 = Supply air F7, extract air F5 I RO-04-R-X-E75 = Supply air F7, extract air F5 incl. spare filters Dampers The EASYAIR is supplied with internal, air tight dampers (tightness class 2). One damper at the air inlet for outside air and one damper at the air outlet for extract air. Therefore, additional dampers are not required to be installed in the supply and/or extract air ducts for the majority of applications. The internal dampers are supplied with actuators. Silencer module (sound absorber) The noise emmissions from the EASYAIR -Equipment, which are already designed to be minimal, can be further reduced by ordering an optional silencer module. Various silencing options are available and our two silencing units, with differential insulation levels and measurements can comply with most requirements. I SD00 = without silencer module I SD10 = a short, silencer module built into the external/internal air-supply side I * I SD22 = two, longer silencer-modules installed on both sides of the unit for intake and output outlets. * Both parameters can be incorporated in the order, with values from 0, 1 and 2. 0 = without silencer module 1 = with a short, silencer module 2 = with a longer, silencer module First figure = implementation on the external/input- air side Second figure = implementation on the ventilation/ extract side (compare with the technical drawing on pages 4/5 and 6/7). Rotary heat exchanger (thermal wheel) I Optimised energy recovery I Particularly suitable for variable air flows I Compact construction Applications: I Schools, offices, administrative buildings I Club houses, function rooms I Shops I Sport halls Plate heat-exchanger (counter flow) I Supply and extract air is completely separated (no cross flow contamination) I Optimised energy recovery I Reduced maintenance costs Applications: I Exhaust air for toilets I Locker rooms I Medical buildings, health centres I Retirement homes Note: Due to the separation of the supply and extract air, the application of plate heat exchangers for hygienic systems is possible without any restrictions. Fan with EC motor I Maximum motor efficiency I Compact construction I Integrated vibration decoupling I Energy efficient operation I Extended sustainability I Low maintenance costs The modern motor technology of the EASYAIR air handling units ensures a quiet and energy efficient operation in all application areas. 9

Unit design and options Duct connections Acoustically insulated duct connec tions are available for all EASYAIR air handling units and utilize the complete open cross-section of the unit. Using these duct connections, the duct of the EASYAIR air handling unit is well insulated against the transmission of sound and vibration. External noise transmission is substantially reduced. I RO-04-R-X-75-MK-Z = with duct connections I RO-04-R-X-75-MK-O = without duct connections I RO-04-R-X-75-MK-C = with a constant, temperature protection shield connector Electric air heater (option) An electric air heater can be connected to each EASYAIR (up to unit size -06). This electric air heater is directly installed on the air outlet and is available with a performance between 3 and 15 kw. In case the outside air temperatures are low, you can slightly increase the room temperature until the desired temperature has been achieved. I -ELE = with electric air heater Hot water air heater (option) Each EASYAIR can be supplied with a hot water air heater. This heater is directly installed at the air outlet. In this case, you also have the simple option to slightly increase the room temperature during cold periods and to provide a comfortable room temperature. The heater is supplied with frost protection. I -WWE = with hot water air heater (LPHW) Heater/cooler module (option) For demanding applications, you can also connect an additional module to the EASYAIR (refer to pages 4 and 5). In this module you will find all the required accessories to provide a wide range of applications for cooling and heating. The module is equipped with a drip separator. I -WKE = module with heater (LPHW), cooler (LPCW) and drip separator Evaporator / Condenser Module (Option) EASYAIR -units with dimensions from -02 can be operated with a reversible cooling and/or heating machine which enables the heating and cooling processes to function without additional hot and/or cold water supplies. The chosen system comprises of an add-on, complete evaporator, expansion valve and control unit. These components are pre-installed and are integrated in the high quality unit housing of the EASYAIR Add-on. A inverter-controlling unit from LG (Multi V) is installed as an external operating unit. This unit justifies its inclusion due to the high COP/EER- Values and is operated with the highlyefficient cooling element R410A. Control The EASYAIR air handling units have standard integrated controller. All the internal components of the units are prewired and ready for use. An extract air temperature sensor in combination with a heating and /or cooling coil guarantees a constant supply air temperature. The majority of the energy efficient, control functions are integrated in the software and are easily extended by using additional options. The available options are as follows: I -RA = Room sensor I -DK = Constant pressure control I -VK = Constant air volume control I - AQ = AL-KO air quality control in the extract duct I -RC = Remote control with 10 m cable I -BL = Bus module LON I -BM = Bus module Modbus I -BB = Bus module Bacnet/Ethernet I -CX = Without control Note: The measurement values (data points) and communication commands are permanently configured and are independent of the Bus module and cannot be changed. Without control All field devices are wired for easy connection to an on-site controller, on a terminal strip. Therefore, there is no separat unit or on-site wiring required. Furthermore, a main switch for allphase switching is installed on the unit. The power fuse is not included in the design and must be supplied on site. 10

For EASYAIR units with rotary heat-exchangers, the connections of the drive motor are supplied through the terminal strip. The unit has no integrated rotor control. Only a rotor drive with integrated speed set point input is provided. The operation is additionally monitored using a potential-free (closing) contact fed through the terminal strip. quality of the extract air. If this sensor detects odours or emissions in the extract air (VOC = Volatile Organic Compounds), the quantity of air is increased and, within a short period of time, good quality air is guaranteed in the room again. If there are e.g. only a few people in the room, the AIRQUALITIZER can reduce the air volume (partial load operation) and you are able to reduce the operating costs. By using this intelligent air flow management, only the required air flow is conveyed. The AL-KO air-quality controller AIRQUALITIZER monitors the 11

Order Code I WRG Type, Equipment stand and unit dimensions; compare with pages 4/5 and page 8 RO-04-R-X-75-SD11-0-hhh I R Service side in I X I 75 I SD00 I O I ELE (option) supply air direction Casing in non-split Supply air F7, Without silencer Without duct with electric air heater right design extract air F5 I T I E75 I L Service side in Casing in split Supply air F7, supply air direction design extract air F5 incl. left spare filters I W Casing for outdoor installation I H Casing for outdoor installation with intake and extract hood Reference Note: The alphabetical key for the control system's options can be found on Page 10. I SD01 With a short silencer module (sound absorber), only on the inlet and outlet connection I * I SD20 With a longer silencer (sound absorber) module; only installed on the external /intake air vent connection Reference Note: Further installation possibilities are depicted on Page 9. connections I Z With duct Connections I C With a temperatureresistant, protection shield I WWE (option) hot water heater I WKE (option) Module with heater (LPHW) and cooler (LPCW) and drip separator I WDV (option) Additional module with a reversible evaporator incl. TA and a VRF external unit 12/2011; Technical improvements may affect the information provided. AL-KO THERM GMBH Bereich Luft- und Klimatechnik Hauptstraße 248 250 89343 Jettingen-Scheppach Germany Fon + 49 8225 39-0 Fax + 49 8225 39-2113 easyair@al-ko.de www.al-ko.com The easy way to EASYAIR http://easyair.al-ko.de