HP UPS R1500 Generation 3



Similar documents
HP R12000 and R18000 DirectFlow UPS User Guide

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

AU-110 racking guide NBXPN: 023

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

How To Install A Power Supply (Uplast) With A Battery Pack

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

Wall-Mounting your HP computer. User Guide

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Memory Modules User Guide

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

42U/45U 28" Wide Rack Installation & Service Guide

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

HP Port Switches Quick Setup Guide

HP 16/18-Port Cable Management Kit Installation Guide

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

MCR1900 Media Converter 19-Slot Chassis

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

esata External Storage

ATS Overhead Table Shelf System INSTRUCTION MANUAL

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

How To Use A Power Supply Unit (Upu)

Installing Your 960 or 980 Server into a Rackmount Cabinet

HP SATA/SAS hard drive and Solid State Drive installation

Upgrading and Servicing Guide

About the BitStorm 6051 POTS Splitter

HP ProLiant DL165 G7 Server. Installation Instructions

HP 2400/2500 Ultra Light Docking Station User Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

How to Set Up Your NSM4000 Appliance

HP UPS R/T3000 User Guide

MultiVOIP FX SIP Gateways

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

AXIS 291 1U Video Server Rack Installation Guide

MultiVOIP FX FXS-Only SIP Gateways

HP Advanced Wireless Docking Station. User Guide

The power module is Feature Number 8800-F2-901.

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Online UPS. PowerWalker VFI 1000R/1U

Five9NS R2100RS Rack Mount Server. Installation Manual

Installation and Operation Back-UPS 1250, 1300, 1500

About the HotWire Slot Standalone Shelf

The SYSTIMAX ipatch System

QuickSpecs. HP 480/277 Volt Solutions. Overview

APC Step-Down Transformer. User s Manual

User s Manual AURORA 1.2K/2.2K

BX7000 Multi-Access Gateway Getting Started Guide

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

HP UPS T1000/1500 User Guide

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

R5000 Uninterruptible Power System (UPS) Overview

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

HP ProDisplay P19A LED Backlit Monitor. User Guide

Cisco TelePresence MCU 4500 Series safety and compliance information

Advantium 2 Plus Alarm

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

R5000 Uninterruptible Power System (UPS) Overview

StorTrends 3400 Hardware Guide for Onsite Support

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

LIEBERT VNSA Installation Sheet

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

HP Port and 48-Port Switches Quick Setup Guide

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

IP DSLAM IDL Quick Installation Guide

UPGRADING AND SERVICING GUIDE

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

HP 22-in-1 Media Card Reader

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer.

USER MANUAL Online UPS 1K/2K/3K Rack

Powerware 5110 UPS User s manual

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

SuperLoader 3. Quick Start Guide. Installing the Autoloader 0

HP Bluetooth Pendant Headphones User Guide

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

FUSION R400 RAID USB 3.0

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Model 1756 Test Lead Kit

AC Power For Business-Critical Continuity. Liebert PSI. User Manual 750/1000/1500/2200/3000, 230VAC

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

MegaRAID LSIiBBU09 Intelligent Battery Backup Unit

=============================== WARNING

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Small form factor bay converter and hard drive installation

Designjet T2500 emultifunction Series

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

Transcription:

HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001

NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications Commission (FCC) logo or FCC ID on the label. Class A devices do not have an FCC logo or FCC ID on the label. After determining the class of the device, refer to the user guide for complete regulatory compliance notices. Overview The HP UPS R1500 G3 features a 1U rack-mount design and offers power protection for loads up to 1320 VA/1000 W (NA/TWN), 1200 VA/900 W (JPN) or 1500 VA/1000 W (INTL). For more information about any of the topics covered in this document, see the UPS user guide located on the documentation CD or HP website (http://www.hp.com/go/rackandpower). Precautions Save these instructions. This document contains important safety instructions that should be followed during installation, operation, and maintenance of the UPS and batteries. WARNING: A risk of personal injury from electric shock and hazardous energy levels exists. The installation of options and routine maintenance and service of this product must be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with AC power products. WARNING: To prevent personal injury from earth conductor leakage current: Do not operate the UPS while disconnected from the utility power source. Disconnect load devices before disconnecting the UPS from the utility power source. 23 kg 50.5 lb This symbol indicates that the UPS exceeds the recommended weight for one individual to handle safely. WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling. Kit contents Important Safety Information guide This document and/or documentation CD HP Infrastructure Management Pack CD To download the latest software version, see the HP website (http://www.hp.com/go/rackandpower). Warranty information Rails, with mounting hardware Mounting brackets, with associated hardware UPS Front bezel Serial computer interface cable USB computer interface cable Jumper cords for load equipment power (INTL model only) Rear stabilization brackets Tools required A Philips screwdriver is required. Selecting a site WARNING: To prevent fire or electric shock, install the unit in a temperature- and humidity-controlled indoor environment, free of conductive contaminants. When selecting a site, consider the following factors: Elevated operating ambient temperature If the equipment is installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment might be greater than room ambient temperature. Install the equipment in an environment compatible with the operating temperature. Reduced air flow In the rack, the rate of air flow required for safe operation of the equipment must not be compromised. Circuit overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable earthing Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit, such as the use of power strips.

Electrical requirements All models require a dedicated (unshared) branch circuit, suitably rated for the specific UPS as stated in "Input specifications" in the user guide. 2. Loosen the wing nuts or hex nuts, and then extend the brackets to the desired length. Readying the equipment 1. Check the battery recharge date specified on the label that is affixed to the shipping carton. IMPORTANT: Do not use the battery if the recharge date has passed. If the date on the battery recharge date label has passed without the battery being recharged, contact an HP authorized service representative for directions. 2. Transport the packaged unit to its installation location. 3. Unpack the equipment near the rack where the unit will be assembled. CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack. Install the heaviest item first, and continue to populate the rack from the bottom to the top. 3. Use the cage nut tool to install cage nuts or clip nuts into the rear of the rack. Installing the mounting rails WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: The leveling feet are extended to the floor. The full weight of the rack rests on the leveling feet. The stabilizing feet are attached to the rack if it is a single-rack installation. The racks are coupled together in multiple-rack installations. Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason. 1. Attach the side-mounting brackets to the unit. 4. Insert screws through the mounting rail into the cage nuts or clip nuts.

5. Use the cage nut tool to install cage nuts or clip nuts into the front of the rack. 2. Attach the chassis to the rack using the supplied screws. 6. Insert a screw through the bottom hole of the mounting rail into the cage nuts or clip nuts. 3. (optional) Insert the rear stabilization brackets into the mounting rails and then attach the brackets to the UPS. 7. Tighten the wing nuts or hex nuts. Installing the UPS Before installing the unit, review and adhere to all warnings provided in "Precautions (on page 2)." WARNING: A risk of personal injury or damage to the equipment exists. Uneven loading of equipment in the rack might cause the rack to become unstable. Install the heavier components first, and then continue to populate the rack from the bottom to the top. 1. Install the mounting rails. Connecting the batteries WARNING: The unit contains sealed lead-acid battery modules. To prevent fire or chemical burns: Do not attempt to recharge batteries after removal from the unit. Do not disassemble, crush, or puncture the batteries. Do not short the external contacts of the batteries. Do not immerse the batteries in water. Do not expose to temperatures higher than 40 C (104 F). WARNING: To prevent personal injury from hazardous energy: Remove watches, rings, or other metal objects. Use tools with insulated handles. Do not place tools or metal parts on top of batteries. IMPORTANT: Before performing the following tasks, be sure that the unit is powered down and disconnected from the utility power source.

NOTE: A small amount of arcing may occur when connecting the batteries. This is normal and does not damage the unit or present any safety concern. Connect the battery lead to the battery terminal. R1500 G3 JPN/TWN R1500 G3 NA R1500 G3 INTL Output voltage Input voltage range DIP switch 1 DIP switch 2 100 V* 90 106 V Down Down 110 V 99 116 V Down Up 110 V 99 116 V Down Up 120 V* 108 127 V Up N/A 220 V 198 233 V Down Up 230 V* 207 243 V Up N/A 240 V 216 254 V Down Down Connecting the host computer Attaching the UPS front bezel CAUTION: Only one communications port can be connected to the host computer. Connecting more than one will result in unexpected UPS behavior. If an option card is installed, the serial and USB communications ports are automatically disabled. Connect the UPS to a host computer using either the USB cable or the DB9 serial cable included with the UPS. Install HP Power Protector on the host computer. See the HP website (http://www.hp.com/go/rackandpower) to download the latest version of HP Power Protector. NOTE: To install and configure the software, see the software user guide. The software user guide is available for download from the HP website (http://www.hp.com/go/rackandpower). Connecting the serial communications port Selecting the UPS voltage configuration Using a small tool, position the DIP switches according to the desired voltage configuration. CAUTION: Use only the computer interface cable supplied with the UPS to connect the communications port to the host computer. IMPORTANT: Power management software requires the communications port to be appropriately cabled to the host computer. NOTE: An asterisk (*) indicates the default setting. For information about serial port pin assignment, see "Serial communications port pin assignment" in the user guide.

Connecting the USB communications port Connecting devices to the UPS CAUTION: Do not plug laser printers into the UPS output receptacles. The instantaneous current drawn by this type of printer can overload the UPS. Before connecting devices, verify that the UPS will not overload by checking that the ratings of the devices do not exceed the UPS capacity. If the equipment rating is listed in amps, multiply the number of amps by the selected output voltage to determine the VA. Connecting the Network Transient Protectors CAUTION: To avoid damaging the equipment, use the Network Transient Protector with a standard telephone line only, not with a digital PBX. To protect equipment against surges over a network data line: 1. Connect the network wall jack to the UPS Network Transient Protector IN jack. 2. Connect the equipment to the UPS Network Transient Protector OUT jack. After verifying that the UPS will not overload: Connect the device power cords to the output receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or- Connect devices to the output receptacles on the rear panel of the UPS using the jumper cords included with the UPS (INTL model). Powering up the UPS Press and hold the Power On/Standby button (1) until the UPS beeps. The Power On, Load 1 and Load 2 LEDs illuminate, indicating that power is available at the UPS output receptacles. Connecting the UPS to utility power WARNING: To prevent injury from electric shock or damage to the equipment: Plug the input line cord into a grounded (earthed) electrical outlet that is installed near the equipment and is easily accessible. Do not disable the grounding plug on the input line cord. The grounding plug is an important safety feature. Do not use extension cords. 1. Connect the input power cord to the IEC-320-C14 input power connector on the UPS rear panel (INTL model only). 2. Connect the UPS power cord to a grounded utility power outlet. When the UPS is plugged in, the batteries begin to charge. Power to the output receptacles designated for surge and battery backup is not available until the unit is powered up. Charging the UPS batteries With the UPS in Standby mode, allow the batteries to charge before putting the UPS into service. IMPORTANT: Charge the batteries for at least 24 hours before supplying backup power to devices. The batteries charge to: 90% of their capacity within 4 hours 100% of their capacity within 24 hours Installing the optional UPS Network Module NOTE: It is not necessary to power down the UPS before installing the UPS Network Module. For more information about receptacle control, see "Power protector software" in the user guide.

1. Remove the two screws securing the UPS option slot cover plate and remove. Connecting the UPS Network Module The UPS Network Module card is provided to manage the attached servers. RJ 45 network patch panel cables are required to use this card. The RJ 45 network patch panel cables are not included. 2. Install the UPS Network Module along the alignment channels in the option slot. 3. Secure the UPS Network Module using the two screws you removed in step 1. 4. If the UPS is powered up, you can be sure that the UPS Network Module is seated properly and communicating with the UPS by verifying that the UPS Data LED illuminates solid green, and then flashes regularly after 2 minutes.

Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Part Number: 650952-001 January 2011 Edition: 1