CAN/ULC-S561-03 Installation and Services for Fire Signal Receiving Centres and Systems- Ottawa 2013



Similar documents
OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

Fire Alarm System Monitoring - CAN/ULC-S561-03

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Module 4, Lesson 12 Fire Alarm Systems

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Alarm Systems Using Wireless or Other Transmission Technology as a Single Path of Communication. Purpose. References. Description of Code Reference

DTW Works Master Specification Version 2006

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Agenda. Agenda (continued) Fundamentals of Fire Alarm Systems

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

The Evolution of Requirements for Supervising Station Alarm Systems

January 1, RE: TG-7FS Sole Path Cellular Alarm Communicator. To whom it may concern:

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

NATIONAL FIRE ALARM AND SIGNALING CODE

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

HERNANDO COUNTY FIRE ALARM GUIDELINES

UL s Perspective on IP Signaling Larry Shudak Principal Engineer Signaling and Security Control Equipment Underwriters Laboratories Inc.

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Fire Prevention Coffee Break Training. November 2015

Design Standards Fire Alarm Systems Division (1995 CMS); (2004 CMS) Amended Feb 2015

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

Loop Start or Ground Start?

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

Michael Catalano 24 Nassau Avenue, Islip NY Phone (631) Chief Fire Marshal Fax (631)

BASIC FIRE ALARM TRAINING

Commercial Fire Alarm Standards July 1, 2010 Edition Page 1 of 14

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

Voice Over IP Digital Phone Concerns with Security and Fire Alarm Communications Systems

BUILDING DESIGN STANDARDS UNIVERSITY SERVICES ELECTRONIC SAFETY AND SECURITY - DIVISION 28 Fire Alarm Systems

PLAN REVIEW GUIDE FOR FIRE ALARM

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

1.0 General. Inspection, Testing, and Maintenance 1 of 8

Central Station Interface with Fire Alarm and the Relevant Codes & Standards

Fire Alarm Engineering Best Practices. CFAA NCA Technical Seminar 2014

Ark Tsisserev, P.Eng. Senior Technical Manager CFAA Technical Seminar April 15, 2015

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

Fire Alarm Systems Certification

TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS

SECTION FIRE ALARM AND DETECTION SYSTEMS

Fire Alarm Submittal Requirements and Acceptance Testing

Fire Alarm System Plans Review Checklist Property location Date of Review

Bold items are particular to the City of Euless

Your Canadian Security Specialists. Eddie D Orazio

Fire Alarm Trainee Log Book

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

The Pennsylvania State University Physical Security Office. Intrusion Alarm. Performance Specification

Fire Alarm Log Book. Any activity regarding this system must be documented in writing.

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

CHAPTER. Fire Alarm Systems APPROVAL AND ACCEPTANCE. Shop Drawings

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SECTION FIRE ALARM AND DETECTION SYSTEM

Sprinkler and Fire Alarm Systems for the Building Official

Installation Instructions & Owner s Operation Manual for Two to Eight Zone 2400 Series Fire Alarm Control Panels

Austin Independent School District Police Department Policy and Procedure Manual

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

UL Fire Door Inspection Service. UL Fire Alarm Certification Program. A valuable but misunderstood resource for jurisdictions

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

rpsa FIRE PROTECTION ENGINEERS

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

Peter Lowitt President Lowitt Alarms and Security Systems, Inc. Chairman CSAA Public Sector Liaison Committee

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.

FIRE ALARM APPLICATION

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

EXHIBIT A SCOPE OF WORK

FIRE CODE INTERPRETATION

LOCAL LAW BE ENACTED BY THE BOARD OF TRUSTEES OF THE VILLAGE OF MAMARONECK AS FOLLOWS:

Phone Company or Phony Company? Part 2 by Dean K. Wilson, P.E.

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

AlarmNet Network Overview

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

TITLE 9-1 BURGLAR AND HOLDUP ALARM USERS REGISTRATION; FALSE ALARM

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

What Should I Expect From My Alarm Monitoring Station?

Transcription:

CAN/ULC-S561-03 Installation and Services for Fire Signal Receiving Centres and Systems- Ottawa 2013 Alan Cavers, Engineering Manager Underwriters Laboratories of Canada Dec. 2013 Copyright 1995-2007 Underwriters' Laboratories of Canada. All rights reserved. No portion of this material may be reprinted in any form without the express written permission of Underwriters Laboratories of Canada or as otherwise provided in writing.

CAN/ULC-S561-03 Fire/Sprinkler Alarm Monitoring Ontario p/2

Top 10 Things to Know About CAN/ULC-S561-03 1. Referenced in the OBC and OFC 2. Covers Signal Receiving Stations and Installations 3. Trained Staff 4. Signal Transmitting and Receiving Equipment 5. Communication Systems p/3

10 Things - continued 6. Types of Systems 7. What is a compliant system 8. Transmission times 9. Periodic testing 10. ULC Certificate Program p/4

Why is this important to you? Installed Systems must meet the intent of the Code. Know how to combine fire and burglar alarm detection systems. Understanding the AHJ requests for compliant systems p/5

CAN/ULC-S561-03 Signals to the Fire Department New Buildings - OBC Existing Buildings OFC p/6

Mandated in Ontario Signals to the Fire Department Ontario Building Code - 3.2.4.7 (4) (CAN/ULC-S561) Ontario Fire Code - 6.3.1.2 (2) (CAN/ULC-S561) p/7

All Code References OBC 3.2.4.5 (1) CAN/ULC-S524-06 OBC 3.2.4.5.(2) CAN/ULC-S537-04 OBC 3.2.4.7 (4) CAN/ULC-S561-03 OFC 6.3.1.2. (1) CAN/ULC-S536-04 OFC 6.3.1.2 (2) CAN/ULC-S561-03 p/8

Fire Alarm System Monitoring 5.15.1 (CAN/ULC-S524) - The interconnection wiring from the fire alarm control unit or transponder to the fire signal receiving centre shall comply with CAN/ULC-S561, Installation and Services for Fire Signal Receiving Centres and Systems. CAN/ULC-S537-04 Appendix C2 (G) Documentation to include the name and number of the Fire Signal Receiving Centre (CAN/ULC-S561) Extension of the Fire Alarm System p/9

Fire Alarm Installation BUILDING and ELECTRICAL PERMIT FIRE ALARM SYSTEM INSTALLED FIRE ALARM SYSTEM VERIFIED VERIFICATION Documentation ULC CERTIFICATE/ Document Protective Signaling Certificate Building/Fire Official Acceptance Occupancy Granted p/10

New Fire Alarm - Documents New Building Building and Electrical Permit Fire Alarm System- Design/ Build documentation from the Engineer on record Stamped by the AHJ Fire Alarm System is installed to CAN/ULC-S524 Verification CAN/ULC-S537-04 Documentation to be provided to the building owner and building official Letter form the Engineer on record Sign-off on the design/build Letter from the Electrical Contractor- Installation to CAN/ULC-S524 Verification Report- No Deficiencies Certificate or Document Monitoring of the Fire Alarm System in Accordance with CAN/ULC-S561-03 p/11

What makes up a compliant System? Compliant System Protected Premise Transmitter Fire Alarm Panel Sprinkler Riser Communication Path Active or Passive Multiplex,Internet DACT c/w Cell Fire Signal Receiving Centre Receiving Units Sufficient Staff p/12

New Systems- CAN/ULC-S561 Shall use CAN/ULC-S559 compliant Signal Transmitting unit. Communication Channel Active/Passive newest technology Manufacturer s Installation Instructions p/13

Existing Systems- CAN/ULC-S561 Will accept CAN/ULC-S527 compliant signal transmitting units - Must upgrade connecting wiring - conduit - supervision of fire alarm, trouble & supervision - communicate alarms within 60 sec. Signal Receiving Centre shall be CAN/ULC-S561 compliant p/14

Signal Receiving Centres Full Service Signal Receiving Centre Shared Service Signal Receiving Centre Proprietary Signal Receiving Centre p/15

Full and Shared Service Signal Receiving Centres Two Hour Fire Separation Security Vestibule ( two door entry) Standby Power Compliant Signal Receiving Units Compliant Station Automation Software Sufficient Trained Staff to handle signals Full Service Trained Technicians on Staff Shared Service- Partner with ULC Listed Alarm Service Companies p/16

Proprietary Signal Receiving Centres Two Hour Fire Separation Exception: Sprinklered = 1hour Single Locked Door Protect own properties Trained Staff to handle signal receiving and alarm installation p/17

Qualification of Personnel Recognized by the AHJ Must have knowledge of the fire alarm panel and the interconnection with the fire alarm transmitter. Working on Transmitter No Requirement p/18

Typical Installation p/19

Newer Installation- Passive p/20

New Installation- S561 Compliant p/21

System Requirements for Installation ULC Listed Transmitter(S559/S527 Compliant) Electrical Permit required for 120v Supply Grounding of Transmitter (manufacturer s specifications) AC Power from a separate breaker - label Transformer properly installed p/22

System Requirements for Installation Install CA38A Jack No direct wiring Do not twist wires or EOL s under terminal screws Metallic conduit protection all connecting wires Standby Batteries (24hrs)- Dated Additional modules/relays properly mounted (Stand-offs, tie raps) p/23

Additional requirements Supervised connections- (loop troubles) - fire alarm, fire trouble, fire supervisory Supervise removable terminal strips Monitor for AC failure Monitor for Communication failure Fire alarm signals transmitted in 60 sec. Dispatch on fire in 30 seconds p/24

Communication Paths Active System - DVACS- active multiplex - GSM Units - Internet constantly supervised - 24 hr standby power - Router, modem, Switches No VOIP allowed p/25

Communication Paths Passive Communication Signals- Fire alarm on both paths - Separate paths- Telco and Cell - Telco and internet - Local annunciation - Exception- No cell service or internet - Separate path - Conduit on a single run - Local annunciation - Relocate the transmitter or use antenna extension p/26

Communication Systems Methods of Communications: Passive or Active Maximum Time to receive a fire alarm signal from a protected premises 60 seconds A communication system shall be continuously supervised to detect line faults Passive Systems Communication Path tested ever 24hrs. p/27

Signaling Services Clause 9.4 Fire Alarm Control Units: Alarm, troubles and Supervisory Signals Restoration Power failure conditions Restoration Alarm Signal shall be transmitted regardless of an abnormal condition at the protected premises. Fire Alarm Signal shall always be the highest priority Integral communication devices in fire alarm panels shall be programmed to transmit alarm, trouble & supervisory conditions. p/28

Standalone Sprinkler Risers Waterflow Fire Trouble Fire Supervisory p/29

Trimmed Sprinkler p/30

Periodic Testing p/31

Waterflow Switch p/32

Gate Valve p/33

Periodic Testing Fire Alarm System - Annually Waterflow Every two months Supervisory- Gate Valves, Pressure - Every Six months p/34

Disposition of Signals Clause 9.4.4 Fire Alarm Signals from a Fire Panel or Extinguishing System: Contact fire department within 30 seconds Contact persons designated by the owner within 5 minutes p/35

Disposition of Signals Cont s Fire Trouble and Supervisory Communication Troubles Signal Transmitting Unit Troubles - Contact Owner within 5 min. - Dispatch service within 4hrs. p/36

Removable Terminal Strip p/37

Removable Terminal Strip p/38

CAN/ULC-S561-03 Property Managers and Alarm Companies Shall Comply to OFC Signals to the Fire Department by way of Fire Alarm Monitoring System in Compliance to CAN/ULC-S561-03 Shall provide a Certificate of Compliance attesting that the fire alarm monitoring system is in compliance to the applicable Standard. Submit document to AHJ Usually done by a ULC Listed Fire Alarm Monitoring/ Installation Company p/39

ULC Certificate Program Copyright 1995-2007 Underwriters' Laboratories of Canada. All rights reserved. No portion of this material may be reprinted in any form without the express written permission of Underwriters Laboratories of Canada or as otherwise provided in writing.

ULC Certificate for Monitoring p/41

Benefits of the ULC Certificate to the Local Authorities Extra Set of Eyes and Ears Allows for a quicker inspection by Building and Fire Officials Confidence in the Fire Alarm Monitoring System meets all the requirements of CAN/ULC-S561-03 Systems are audited on a random basis Non-compliant systems can result in the cancellation of the ULC Certificate p/42

Who can issue a ULC Certificate? Full Service Monitoring Station - ULC Installation and monitoring Same company Proprietary Monitoring Service Trained Staff Shared Service Monitoring Station with Installation Company - ULC Two different companies

ULC Certificate Program For CAN/ULC-S561-03 Compliant Systems, ULC can issue a Certificate stating Compliance to the Standard- Meets OBC & OFC The ULC Certificate is the only proof that the entire fire alarm monitoring system is compliant Each site is issued a certificate is subject to a random audit p/44

Proper Certified Installation p/45

Improper Installation The Unknown? What you get when no one Polices system installations! p/46

System Modifications p/47

Adding Unlisted Relays p/48

ULC Listings- Online Directories WWW.ULC.CA- Online Directories Category Codes associated to ULC Listings DAYRC- CAN/ULC-S559-04 Equipment DAYYC- CAN/ULC-S561-03 Shared Installation Co. DAYIC - CAN/ULC-S561-03 Shared and Full Service Fire Signal Receiving Centres p/49

Questions p/51

CAN/ULC-S561-03 THANK YOU Contact Information Alan Cavers, Engineering Manager, Fire & Security Systems Group, Underwriters Laboratories of Canada Phone- 1-416-697-6762 E-mail alan.n.cavers@ul.com p/52

Improper Installation p/53

Improper Installation p/54