Passive Fire Protection

Similar documents
CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Waterproofing construction Joints

12.1 Schlüter -KERDI-BOARD

Composite Panel Firewall Systems

Introduction to cable fire stopping

Tremco Fire Protection Systems Group Technical Bulletin

Flamesafe Firestopping Products. Firestopping Products.

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

Fire Collars For Plastic Pipe Penetration

Adhesives. Sticking to what we know best! Bonding and cleaning Window and door construction PVC, aluminium and wood. 33/08 made by Weiss

Concrete Waterproofing Systems. Integral Protection.

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

FIRESTOPPING & SMOKE SEALS

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces

FIRESTOPPING. Cable. Firestopping is the technology used to

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

FireWall. High performance fireresistant. FireWall.

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Fire Security Systems

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

Fire Barriers & Fire Stopping

plumbing products guide

CABLE TRENCH INSTALLATION GUIDE

GPD Rubber Press Seals

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

GYPSUM AREA SEPARATION FIREWALLS GA

Mapei systems for radiating floor heating with high thermal efficiency

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

Eurooppalainen tekninen hyväksyntä ETA-12/0045 European Technical Approval

Fire Barrier Duct Wrap 15A

Swimming Pool Tiling Specialists

sound reduction systems for commercial, educational and industrial environments

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Complete Firestop Systems Guide

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

Fire Stopping and Sealing Product: Penetration Seals

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

Technical Data Sheet Astro Flexi Coat. UIC of product-type: FLEXCS CPR-JA5014

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

POLYURETHANE FOAM CONCEPT

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

pinta ACOUSTIC PANEL [1/7]

H-Stud Area Separation Wall System

Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications

Puddle Flange. FRANK Puddle Flange

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

BETONYP building boards. The modern way of living.

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

European Organisation for Technical Approvals

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Re-Enterable Solutions. Permanent Solutions. Fail Safe Firestop Solution

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Excerpts from the Canadian National Building Code (NBC)

WATERPROOFING OF WET ROOMS

Guide for SOLID CONCRETE BLOCK SEALS

LATICRETE 290 Premium Floor and Wall Thin-set Adhesive PRODUCT DESCRIPTION

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

Schluter -Shower System Installation Handbook Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds

TECHNICAL DATA SHEET. TOPECA, Lda Rua do Mosqueiro Cercal Ourém PORTUGAL. Tel.: Fax.:

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Rockwool Flexi Insulation Application Guide

B. Product Schedule: For each penetration firestopping system. Include location and design designation of qualified testing and inspecting agency.

ASFP Ireland - Fire Safety Certification. Colin Keeley Senior Site Inspector & Training Officer 22 nd September 2011

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Mineral waterproof coating PCI Dichtschlämme

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

PRODUCT INFORMATION : ADHESIVES DELIVERING THE FUTURE OF COMPOSITE SOLUTIONS ADHESIVES. contact@gurit.com

Management Consultancy Training. Asbestos Materials. Residential Guide

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

USER GUIDE Easier, Safer, Betta! gripsetbetta.com WATERPROOFING

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Ubiflex. Non-lead flashing system

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Saferand easierinstallation

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

IMPACT DAMAGE RESISTANT WALL SYSTEMS

Mold Preventing I nterior System

Hydrophobe VII., Lisbon

Transcription:

Firestopping Passive Fire Protection

FS20 Firestop Compound 6 hour fire rated penetration seals for electrical and mechanical services

FS20 Firestop Compound FS20 Firestop Compound is a Fire-Rated Penetration Seal It is a dry mortar mix with a controlled swelling effect to provide a non-shrink homogeneous and smoke gas-tight fire seal. Has Fire-Ratings up to 6 hours Has applications for cables, pipes and ductwork Can be utilized as a structural mortar Easily applied by pump, Trowel or hand Covers large penetration sizes Easy retrofitting of cables

FS20 Firestop Compound No permanent formwork required for smaller penetrations No sealant required after cure Large packaging 22kg 2 hours 75mm thickness 3.15 Bags / m2 3-6 hours 100mm thickness 4.2 Bags / m2

Notable FS20 Approvals Firestopping IFC Approved BS476, Part 22 2 hours 75mm BS476, Part 22 3-6 hours 100mm AS1530, Part 4 2 hours 75mm AS1530, Part 4 3-6 hours 100mm Acoustic 50mm 39dB Acoustic 100mm 46dB Acoustic 150mm 51dB

Sizes and Ratings Firestopping Non-Structural Applications

Sizes and Ratings Firestopping Structural Standard reinforcement can be Applications placed in the placed in the penetration to make it a fire rated Structual penetration seal

FS21 Firestop Panel 4 hour fire rated penetration seals for electrical and mechanical services

FS21 Firestop Panel FS21 Firestop Panel is a Fire-Rated Penetration Seal FS21 Firestop Panel consist of High Density Rockwool and FS15 / FS23A Has Fire-Ratings up to 4 hours Consists of single coated Panel Has applications for cables, pipes and ductwork Is water and Weather resistant Has mechanical resistance Large penetration sizes Easy retrofitting of cables

Notable FS21 Approvals Firestopping IFC Approved BS 476, Part 20 4 hours BS 476, Part 22 4 hours AS1530, Part 4 2 hours 75mm AS1530, Part 4 3-6 hours 100mm

Sizes and Ratings Firestopping Non-Structural Applications

Types of Applications Firestopping

Application of FS21 Firestop Panel Firestopping Friction fit only required Slots into opening around cable trays FS23A Sealant applied at joins, cable trays and substrate (as glue) FS21 Panels 1200 x 600 x 50mm (pre-coated) Angle fixture at slab base for larger penetrations

FS22 Firestop Pillows 4 hour fire rated expanding Pillows for cable penetrations

FS22 Firestop Pillows Expanding pillows for cable penetrations Pillows consist of a tightly woven fire proof bag and contents Has Fire-Rating up to 4 hours Expands up to 45% under fire Has applications for cables, pipes and ductwork Water and Weather resistant Dust free No sealant required around the pillows Flexible Perfect for high traffic penetrations Easy retrofitting of cables

FS22 Firestop Pillows Up to 4-hour fire rating for multiple cables 50mm, 100mm, 150mm and 200mm widths Cost effective quick installation Dust free and no sealant required Can reduce Insurance Premiums due to lowering the fire risk

FS22 Firestop Pillows Firestopping FS22 Firestop Pillows not only have a fire proof bag, but also contain ceramic fillers which bonds together under fire. 130 o C (266 o F) Glueing effect 280 o C (536 o F) Expanding effect (45%) 800 o C (1475 o F) Ceramic effect (hardening to ceramic block)

FS22 Firestop Pillow Approvals IFC Approved BS476, Part 20 4 hours BS EN 1366-3 4 hours AS1530, Part 4 4 hours

FS23 Intumescent Sealant 2 hour fire rated High Expansion Intumescent Sealant for electrical cable and pipe penetrations

FS23 Intumescent Sealant FS23 Intumescent Sealant is a high expansion, durable and flexible, one component water based fire rated intumescent sealant. Has Fire-Rating up to 2 hours Expands under fire Has applications for cables, Steel, copper and plastic pipes Water and Weather resistant Packaged in 310ml Cartridges Colour: Dark Grey

FS23 Intumescent Sealant Firestopping Clean and wet substrate Standard Applicator required Installed at 40mm 75mm thickness Mineral wool used for backing (FS21)

FS23 Approvals Firestopping IFC Approved BS476, Part 20 2 hours BS EN 1366-3 2 hours AS1530, Part 4 2 hours

FS23A Intumescent Sealant 4 hour fire rated Intumescent Sealant for joints and electrical cable / pipe penetrations

FS23A Intumescent Sealant FS23A Intumescent Sealant is a durable and flexible, one component water based fire rated intumescent sealant. Has Fire-Rating up to 4 hours Expands under fire Has applications for cables, Steel, copper and plastic pipes and joints Water and Weather resistant Packaged in 310ml Cartridges Standard Applicator required Installed at 10mm 20mm depth PE Backing Foam Also used in conjunction with FS21

FS23A Approvals Firestopping IFC Approved BS476, Part 20 & 22 4 hours BS EN 1366-3 4 hours AS1530, Part 4 4 hours

FS24 Firestop Collars 4 hour fire rated Pipe Collars for pipe penetrations

FS24 Firestop Collars FS24 Firestop Collars suitable for plastic pipe 30mm to 200mm Dia. Has Fire-Rating up to 4 hours Suitable for sealing PVC, UPVC, CPVC, PP, HDPE, MDPE, PE Plastic pipes Large annular gaps filled with FS23 HE Intumescent Sealant Simple to install Colour Red for ease of identification Collar is placed fush to the wall or underside of floor Securely fastened with Fire resistant screws 1 collar required for underside of floor 1 collar either side of wall

FS24 Approvals Firestopping IFC Approved BS476, Part 20 4 hours BS EN 1366-3 4 hours AS1530, Part 4 4 hours