Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10



Similar documents
INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Los Angeles Fire Department Requirement No. 96 SOLAR PHOTOVOLTAIC SYSTEM

SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE (In partnership with interested local fire officials, building officials, and industry representatives)

Understanding the Cal Fire Solar Photovoltaic Installation Guideline

Understanding the Cal Fire

Developed by CA Matt Paiss, and Bill Brooks, PE

How To Plan Out An Array Of Solar Panels

Solar Panel Installations

BOROUGH OF OAKLAND COUNTY OF BERGEN STATE OF NEW JERSEY ORDINANCE 13-CODE-685

SOLAR PV SYSTEMS PERMITTING PROCESS

County of Riverside Building and Safety Department

RESIDENTIAL PHOTOVOLTAIC SUBMITTAL REQUIREMENTS

City of San Diego Residential Photovoltaic Systems Inspection Guidelines

sdci 420 Seattle Permits Tip Solar Energy Systems GREEN PERMIT REQUIREMENTS Building Permit Types of Solar Energy Systems

City of Riverside Building & Safety Division Phone: (951)

Solar Ready Residential Installation Requirements

Solar PV Safety for the Fire Service. Bill Brooks, Brooks Engineering Panel Lead: Code Official Panel, Solar ABC s

Doe Residence kw DC Roof Mounted Photovoltaic System

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Cooktop Low-Profile Ventilation Hoods

Current as of 11/10/08 1 of 1

Solar Photovoltaic (PV) Systems

Fire Alarm System Plans Review Checklist Property location Date of Review

Supplement - Protocol for Photovoltaic (PV) Plans March 11, 2016

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

D. Permits: A building permit is required for the structural support of all solar energy device installations.

Maximum Floor Area and Maximum Development Area

Chapter 6 ROOF-CEILING SYSTEMS

CALIFORNIA FIRE CODE MATRIX ADOPTION TABLE BUILDING SERVICES AND SYSTEMS

Complete Solar Photovoltaics Steven Magee. Health and Safety

Solar America Board for Codes and Standards

Top Commercial / Residential Electrical Requirements *

Request for Proposals for Photovoltaic System Installation

SOLAR ENERGY FACILITIES ZONING AMENDMENTS

Building Code Clarifications - 7. Fire Resistance

NEC Code Calculations for Solar Installations. for Inspectors and Building Officials

Roof Tutorial. Chapter 3:

HM-W536 Install Guide

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Expedited Permit Process for PV Systems AC Module

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

#1258. WHEREAS, the Board of Commissioners of the Township of Haddon has determined the following:

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Electrical Service Guidelines

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

BOOTH DESIGN RULES NEW!

Excerpts from the Canadian National Building Code (NBC)

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Walking and Working Surface Checklist:

Installation Guide Content for P250xV-240 microinverters

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

AC Module Installation Guide Content

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

BUILDING PERMIT SPECIFICATIONS

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System

Division Yard, Lot, and Space Regulations.

Certification: Building Plans Examiner. Exam ID: B3

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

Building Control Guidance Note

Title: The Receptivity of Roofs for Solar Panels

The replacement or modification of existing windows shall comply with the following requirements:

Submittal Requirements for Solar Photovoltaic Installations 10 kw or Less in One and Two Family (Duplex) Dwellings

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

IRFTS SHADOW SOLAR SOLAR SHADE HOUSE STRUCTURE - ENERGY PRODUCTION AND SUN PROTECTION

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Solar Photovoltaic SPECIFICATION, CHECKLIST AND GUIDE. Renewable Energy Ready Home

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Fall Protection Plan for Residential Roofing Construction. Tim Graboski Roofing, Inc.

Electrical safety of grid-connected solar installations in Western Australia December 2011

Building Construction. Lightweight construction. Conventional Construction

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

800 Communications Circuits

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

LIPA. Long Island Power Authority


Understanding the Fire Hazards of Photovoltaic Systems

Errata NFPA 70. Proposed 2014 Edition

How To Make A House Safe

ELECTRICAL CONTRACTORS, SUPPLIERS AND DISTRICT ENGINEERING, CONSTRUCTION & OPERATIONS PERSONNEL

Please check with your local inspection authority for any additional requirements before installation.

Electrical. This section applies to the design and installation of building power distribution systems.

Electrical Code (NEC) Snake Tray Cable Management Solutions

TOP 10 CHANGES 2013 CALIFORNIA ELECTRICAL CODE 2013 CALIFORNIA ENERGY CODE (ELECTRICAL)

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Transcription:

Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10 This document was developed by the Orange County Fire Chiefs Association, Orange County Fire Marshal Committee. It is based upon the Final Draft Photovoltaic Installation Guideline developed by the California State Fire Marshal (SFM). The technical content of the document is consistent with the SFM document with the exception of formatting, clarifying language and additional provisions pertaining to the requirement for a remote disconnect. The Orange County Fire Marshal Committee desires that this document is adopted by local jurisdictions in order to provide a uniform approach to the fire safety issues associated with photovoltaic system installation.

SOLAR PHOTOVOLTAIC FIRE SAFETY INSTALLATION GUIDELINE TABLE OF CONTENTS Purpose 3 Scope 3 1. General Requirements 3 1.1 Marking 3 1.1.1 Main Service Disconnect 3 1.1.1.1 Marking Content and Format 3 1.1.2 Marking DC Circuit 4 1.1.2.1 Marking Content and Format 4 1.1.3 Inverters 4 1.2. Remote Disconnect 4 1.3 Access Path Ways and Smoke Ventilation 5 1.3.1 Residential Systems- Single and Two Unit Dwellings 6 1.3.1.1 Access 6 1.3.1.2 Ventilation 6 1.3.2 Commercial Buildings and Residential Housing- 3 of more units 6 1.3.2.1 Access 6 1.3.2.2 Pathways 7 1.3.2.3 Ventilation 7 2. Location of DC Conductors 7 3. Non- Habitable Buildings 7 4. Ground Mounted Photovoltaic Arrays 8 Examples 9 2 of 14

PURPOSE: The installation of solar photovoltaic (PV) systems presents additional areas of concern for firefighter safety (energized equipment, trip hazards, etc.) and fire fighting operations (restricting venting locations, limiting walking surfaces on roof structures, etc). This guideline establishes the minimum standard for the layout design, marking, and installation of solar photovoltaic systems and is intended to mitigate the fire safety issues. SCOPE: This guideline applies to all solar photovoltaic systems regardless of size for residential and commercial purposes. 1. GENERAL REQUIREMENTS 1.1 Marking PV Systems shall be marked. Marking is needed to provide emergency responders with appropriate warning and guidance with respect to isolating the solar electric system. This can facilitate identifying energized electrical lines that connect the solar panels to the inverter, as these should not be cut when venting for smoke removal. Materials used for marking shall be weather resistant. UL 969 shall be used as a standard for weather rating (UL listing of markings is not required). 1.1.1 Main Service Disconnect For residential applications, the marking may be placed within the main service disconnect. If the main service disconnect is operable with the service panel closed, then the marking should be placed on the outside cover. For commercial application, the marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the lever is operated. 1.1.1.1 Marking Content and Format Marking Content: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED Red Background White Lettering Minimum 3/8 Letter Height All capital letters Arial or similar font, Non-bold Reflective weather resistant material suitable for the environment (durable adhesive materials must meet this requirement) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED 3 of 14

1.1.2 Marking PV Circuit Marking is required on all interior and exterior PV conduit, raceways, enclosures, cable assemblies, and junction boxes to alert the fire service to avoid cutting them. Marking shall be placed every 10 feet, at turns and above and/or below penetrations, and at all PV combiner and junction boxes. 1.1.2.1 Marking Content and Format Marking Content: CAUTION: SOLAR CIRCUIT Red Background White Lettering Minimum 3/8 Letter Height All capital letters Arial or similar font, Non-bold Reflective weather resistant material suitable for the environment (durable adhesive materials must meet this requirement) CAUTION: SOLAR CIRCUIT 1.1.3 Inverters The inverter is a device used to convert DC electricity from the solar system to AC electricity for use in the building s electrical system or the grid. No markings are required for the inverter. 1.2 Remote Disconnect DC Circuits shall be equipped with a means for remote disconnect located downstream from the photovoltaic array at the point where the circuit enters the structure, or at another approved location. Control of the remote disconnect shall be located within five feet of the building s main electrical panel. The remote disconnect shall be listed and meet the requirements of the California Electrical Code Exceptions: 1. DC Circuits contained in rigid or electrical metallic tubing running between the array combiner box and the main electrical panel which are entirely exterior to the building need not be equipped with a means of remote disconnect other than the disconnects intrinsic to the system. 2. DC Circuits contained in rigid or electrical metallic tubing running between the array combiner box and the main electrical panel that run through the interior of the building when installed a minimum of 18 below the roof assembly when measured parallel to the surface of the roof. 3. The system inverter may be used for remote disconnect when located immediately upstream of the roof penetration where the circuit enters the structure. 4 of 14

Signage shall be located immediately next to the remote disconnect control as follows: Marking Content: CAUTION: SOLAR CIRCUIT DISCONNECT Red Background White Lettering Minimum 3/8 Letter Height All capital letters Arial or similar font, Non-bold Reflective weather resistant material suitable for the environment (durable adhesive materials must meet this requirement) CAUTION: SOLAR CIRCUIT 1.3 Access, Pathways, and Smoke Ventilation Access and spacing requirements shall be observed in order to: 1. Ensure access to the roof 2. Provide pathways to specific areas of the roof 3. Provide for smoke ventilation opportunity areas 4. Provide emergency egress from the roof Exceptions to this requirement may be requested where access, pathway or ventilation requirements are reduced due to: Unique site specific limitations Alternative access opportunities (as from adjoining roofs) Ground level access to the roof area in question Other adequate ventilation opportunities when approved by the fire code official. Adequate ventilation opportunities afforded by panel set back from other rooftop equipment (for example: shading or structural constraints may leave significant areas open for ventilation near HVAC equipment.) Automatic ventilation device. New technology, methods, or other innovations that ensure adequate fire department access, pathways and ventilation opportunities. Designation of ridge, hip, and valley does not apply to roofs with 2-in-12 or less pitch. All roof dimensions are measured to centerlines. A roof access points shall be defined as an area that does not require ladders to be placed over openings (i.e., windows, vents, or doors), that are located at strong points of building 5 of 14

construction and in locations where ladders will not be obstructed by tree limbs, wires, signs or other overhead obstructions. 1.3.1 Residential Single and Two-Unit Residential Dwellings 1.3.1.1 Access Plan review is required if a system is to be installed that will occupy more than 50% (Jurisdiction modification as needed) of the roof area of a residential building. Examples of these requirements appear at the end of these guidelines (Examples 1-4). Residential Buildings with hip roof layouts: Modules shall be located in a manner that provides one three-foot wide clear access pathway from the eave to the ridge on each roof slope where panels are located. The access pathway shall be located at a structurally strong location on the building (such as a bearing wall.) Residential Buildings with a single ridge: Modules shall be located in a manner that provides two three-foot wide access pathways from the eave to the ridge on each roof slope where panels are located. Hips and Valleys: Modules shall be located no closer than one and one half feet to a hip or a valley if panels are to be placed on both sides of a hip or valley. If the panels are to be located on only one side of a hip or valley, that is of equal length then the panels may be placed directly adjacent to the hip or valley. 1.3.1.2 Ventilation Modules shall be located no higher than three feet below the ridge. 1.3.2 Commercial Buildings and Residential Housing with three or more units 1.3.2.1 Access Plan review is required if a system is to be installed that will occupy more than 50% (Jurisdiction modification as needed) of the roof area of a commercial building. Exception: If a local fire department determines that the roof configuration is similar to residential (such as in the case of townhouses, condominiums, or single family attached buildings), the local fire department may make a determination to apply the residential access and ventilation requirements. Examples of these requirements appear at the end of these guidelines (Examples 5-8). There shall be a minimum six foot wide clear perimeter around the edges of the roof. Exception: If either axis of the building is 250 feet or less, there shall be a minimum four feet wide clear perimeter around the edges of the roof. 6 of 14

1.3.2.2 Pathways Pathways shall be established in the design of the solar installation. Pathways shall meet the following requirements: 1. Shall be over structural members. 2. Center line axis pathways shall be provided in both axes of the roof. Center line axis pathways shall run on structural members or over the next closest structural member nearest to the center lines of the roof. 3. It shall be in a straight line not less than four feet clear width to skylights and/or ventilation hatches. 4. It shall be in a straight line not less than four feet clear width to roof fire protection standpipe outlets. 5. It shall provide not less than four feet clear width around roof access hatch with at least one pathway not less than 4 feet in clear width to parapet or roof edge. 1.3.2.3 Ventilation Arrays shall be no greater than 150 by 150 feet in distance in either axis Ventilation options between array sections shall be either: A pathway eight feet or greater in width Four feet or greater in width pathway and bordering on existing roof skylights or ventilation hatches Four feet or greater in width pathway and bordering x 8 venting cutouts every 20 feet on alternating sides of the pathway 2. LOCATION OF DC CONDUCTORS Conduit, wiring systems, and raceways for photovoltaic circuits shall be located as close as possible to the ridge or hip or valley and from the hip or valley as directly as possible to an outside wall to reduce trip hazards and maximize ventilation opportunities. Conduit runs between sub arrays and to DC combiner boxes shall use the design that minimizes the total amount of conduit on the roof by taking the shortest path from the array to the DC combiner box. The DC combiner boxes are to be located such that conduit runs are minimized in the pathways between arrays. To limit the hazard of cutting live conduit in venting operations, DC wiring shall be run in metallic conduit or raceways when located within enclosed spaces in a building and shall be run, to the maximum extent possible, along the bottom of load-bearing members. 3. NON-HABITABLE BUILDINGS These guidelines do not apply to non-habitable structures. Examples of non-habitable structures include, but are not limited to, parking shade structures, carports, solar trellises, etc. 7 of 14

4. GROUND MOUNTED PHOTOVOLTIAC ARRAYS Setback requirements do not apply to ground-mounted, free standing photovoltaic arrays. A clear brush area of 10 is required for ground mounted photovoltaic arrays. 8 of 14

EXAMPLE 1 Cross Gable Roof EXAMPLE 2 Cross Gable with Valley 9 of 14

EXAMPLE 3: Full Gable Example 4: Full Hip Roof 10 of 14

EXAMPLE 5 Large Commercial (Axis > 250 ) 8 Walkways 478 6 150 8 Skylights Typical Roof Hatch 6 6 150 8 32 Structural Members

EXAMPLE 6 Large Commercial (Axis > 250 ) Walkways With 8 x Venting Opportunities Every 20 470 6 150 Skylights Typical Roof Hatch 6 6 150 320 Structural Members 12 of 14

Example 7 Small Commercial (Axis < 250 ) 8 Walkways 200 8 100 8 Structural Members 13 of 14

Example 8 Small Commercial (Axis < 250 ) Walkways Venting Opportunities Every 20 Along Walkway 200 100 5-3 19-2 8-3 Structural Members 14 of 14