How To Power Supply In Data Centres



Similar documents
Low and Medium Voltage Division Erlangen, February 18, New MCCBs for Increased Line Protection and Availability

Case Study. Cool and green: Citigroup s Frankfurt Data Center

Infrastructure & Cities Sector

Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply.

Smart solutions for fleets of all types & sizes of power generation. Marcus König, E F IE SGS / September 2013

Green Data Centers. Energy Efficiency Data Centers. André ROUYER Director of Standardization & Environment. The importance of standardization

Siemens solution for Smart cities. Smart cities a picture of the future

Protection notice / Copyright notice

Data Centers: Definitions, Concepts and Concerns

Datacenter Business Opportunities in Finland. Toni Mattila

Data & Digitalization: Cities of the future

Green Cloud Computing: Case Study Sri Lanka & Pakistan

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

An addendum for France & the UK to Cloud Computing the IT Solution for the 21 st Century

Value stacking with Data Center Infrastructure Management (DCIM) - driving energy and capacity efficiency -

Smarter Buildings & Management of Buildings

Code of Conduct on Data Centre Energy Efficiency. Endorser Guidelines and Registration Form. Version 3.0.0

Data center solutions from Siemens. For the factories of the 21 st century. siemens.com/datacenters

The energy self-sufficient family home of the future

NetVision. NetVision: Smart Energy Smart Grids and Smart Meters - Towards Smarter Energy Management. Solution Datasheet

Our future depends on intelligent infrastructures. siemens.com/intelligent-infrastructures. Answers for infrastructure and cities.

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

Nuclear Power Plant Electrical Power Supply System Requirements

How To Make The Power Grid A Communications System For A Smart Grid

Maximum uptime thanks to integrated data center solutions from Siemens

Zurich West Data Center

Siemens Answers for DoD Installations

PV And Storage: Solutions with Potential

May 26, 2011, Strategic Planner Circle Innovation Management at Siemens Building Technologies Division Lucas Schmid, Head of Strategy

The Trellis Dynamic Infrastructure Optimization Platform

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency.

DC Pro Assessment Tools. November 14, 2010

Top Ten Emerging Industries of the Future

Tank Terminals Proven Solutions for Liquid Bulk Storage and Distribution Terminals

Analysis of the Brazilian Data Center Power Supplies Market

Reducing Data Center Energy Consumption

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Common mistakes in datacentre planning

How green is your data center?

Non-Stop Manufacturing Excellence. Automotive. Answers for industry.

San Francisco Chapter. Deborah Grove, Principal Grove-Associates

DATA CENTER. Enhancing the Energy Efficiency and Use of Green Energy in Data Centers

KNX city concept. Dipl.-Ing. Lutz Steiner, KNX Scientific

DataCenter 2020: first results for energy-optimization at existing data centers

Green Computing: Datacentres

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

Data Center Power Distribution at the Cabinet Level: The top 12 questions you need to ask to improve data center energy effciency

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

How do you design maximum data security?

Resilient Urban Infrastructure

Future Grids: challenges and opportunities

Services the Next Level. How Industry Services from Siemens help you discover a new source of competitive advantage. siemens.com/industry-services

Green Data Centers. Jay Taylor Director Global Standards, Codes and Environment (512)

Energy Savings in the Data Center Starts with Power Monitoring

ENERGY EFFICIENT DATA CENTRES AND STORAGE. Peter James University of Bradford

How to build your Data Center Digitice roadshow Vaasa

Power Generation Power Plants. Electrical Engineering Systems for Power Plants

Fiscal Year Guidance Achieved Execution of Vision 2020 Begun

BU Control Technologies, Decathlon TM Product Overview. ABB in the Data Center Overview

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

GE Energy. Solutions

StruxureWare. How to reconcile efficiency and availability in a virtualized data center. for data centers

Capacity Planning in the Modern Datacenter

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Market Growth and New Regulations Demand Network Modernization

Background Information

ICT and the Green Data Centre

Managing Data Centre Heat Issues

IT BUSINESS. Hal Grant, EVP IT. February 19, 2015

optimize your data center environment for greater compliancy, security and efficiency Data Center Services

Security of electricity supply

DOE Data Center Energy Efficiency Program

Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper

Colocation, Hot Seat Services, Disaster Recovery Services, Secure and Controlled Environment

Seize the benefits of green energy and the smart grid

Data Center Facility Basics

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell

Saving Energy For Your Organisation. Top 10 energy saving tips

Introduction to Hitachi Group Environment- conscious Data Center Programme for inspiring change

Applying Data Center Infrastructure Management in Collocation Data Centers

Siemens Transportation Systems Siemens Media Summit

Transcription:

Infrastructure & Cities Sector Background Information Low and Medium Voltage Division Erlangen, November 2013 Framework for Electric Power Distribution in Data Centres Electric power supply is the prerequisite of all Data Centres operations, i.e. computers, screens, hard drives, network components and data lines. It is not only the ICT equipment for which electrical energy must be readily available, but also for infrastructure tasks which includes cooling, air conditioning, fire surveillance and fire fighting, security and access control, lighting, lifts, drives, motors and much more (see Fig. 1). Fig. 1: Power supply is an integral part of the infrastructure in data centres The following performance criteria are important for drawing up a concept of the power supply system: - availability - cost efficiency - reliability Siemens AG Wittelsbacher Platz 2, 80333 Munich, Germany Corporate Communications and Government Affairs Head: Stephan Heimbach : ICLMV20131003e Infrastructure & Cities Sector Low and Medium Voltage Division Freyeslebenstraße 1, 91058 Erlangen Germany Page 1/5

- environmental impact - speed It is the planner's task to optimally design the power supply. In this context a planer must consider both his customer's specifications and legislation or directives. Those general customer requirements which at all costs must be currently considered in planning the electrical power supply as conditioned by the deployment and environmental requirements are: - Energy efficiency - Redundancy - Security - Expandability - Operational Management - Quality The specific characteristics of these factors influence the performance criteria called for, on the basis of which a power distribution infrastructure is planned. For example, additional redundancy integrated in power distribution may improve the availability and reliability of the data centre. However, the higher cost involved for redundant components may have a negative impact on cost efficiency, and an unfavourable utilisation of redundant components in operation may bring about drawbacks in efficiency and thus associated higher energy losses and an avoidable environmental burden. Power Consumption in Data Centres The basic expectation is that the world-wide power demand of data centres will rise. Based on the assumptions of 2007, Microsoft [1], for example, forecasts a continuous rapid upsurge in power consumption. The growth rates of previous years will be continued and the Power-Usage-Efficiency (PUE) factor of 2.0 (i.e. the ratio of the total power demand of a data centre compared to the power demand of its ICT components see [2]) will remain unchanged. In Western Europe, power consumption is set to nearly double from 56 TWh to 104 TWh between 2007 and 2020 according to the European Commission [3]. Even so, this correlates with the values, since it can be expected that the development in : ICLMV20131003e Page 2/5

emerging countries such as China, India or Russia will speed up considerably over the next few years. Other factors of uncertainty which may lead to deviations in estimates of future developments are for instance: - the development of the global economy and competition - protectionism, regulation or liberalisation of markets - changes in the cost of power generation - changes in the cost of labour and material - impact of environmental issues in connection with power generation and consumption - development trends in ICT and infrastructure components for data centres - development trends in user behaviour with regard to Data Centres services such as cloud computing, network applications, security requirements Considering the high requirements placed on the environment of a Data Centre, such as - connectivity to the electric power distribution network and data transmission lines - ambient climatic conditions - avoidance of transportation hubs and industrial plants posing hazards - distance away from military facilities, landfill sites, waste incineration plants and - a low probability of natural catastrophes occurring, it becomes increasingly difficult to find suitable localities for the construction of new data centres on green fields ("green field investments"). Therefore, the modification and extension of data centres ("brown field investments") as well as a consideration of the extendibility of modular systems will become more and more important. Likewise, in-plant power generation and its utilisation in the data centre can increasingly be factored into planning. In this context, a coincidence of power consumption and cooling demand would be advantageous conditional upon the required computation and communication capacity. : ICLMV20131003e Page 3/5

Direct Current in Data Centres Of late IT experts have been discussing the use of electric power supply systems with direct current application for ICT components. Lawrence Berkeley National Laboratory (LBNL) predicted energy efficiency benefits of more than 28% for an average data centre, since the transformation steps from direct current (DC) to alternating current (AC) and vice versa would be avoided [4]. Hower, Data Centers power supply with DC needs to be further investigated. The main positive is that electronic loads are natively DC consumers and the feed in from renewable generation sources like photovoltaic is also DC. DC distribution holds the promise that it will enhance energy efficiency by reducing the need for repeated DC-to-AC and AC-to-DC conversion. However, state-of-the-art Alternating Current (AC) electrical power supply has strong arguments to stay as the lead technology for more than another decade. Without considering the technical details, it can be assumed that owing to the current market situation for servers, storage system and network equipment, no abrupt turn-around towards a second product line of DC power supply components will take place. A consistent and reliable DC approach for electrical power distribution is still not meeting the high power requirements of today s data center needs. Similar energy savings can still be realized through reliable high efficiency AC systems. Power Supply Failures and Their Commercial Effects In data centres, the relevant electrical components must be supplied with electricity with the utmost of reliability 24 hours a day. Malfunctions or even a power blackout and the resulting data losses and operational interruptions will cause substantial economic losses for a data centre operator. Consequential damage owing to the loss of image and trust can be expected in addition. Often, the consequences of IT failures are under-estimated since it is only the lost working time which is factored in the calculation of breakdown costs. Consequential damage, such as the loss of business and customer/investor confidence and possibly even contractual penalties, is not taken into account. The best examples are just-in-time deliveries given in contracts for work and services or building contracts. If delays are caused by IT failure, penalties for breach of contract may be claimed. At the same time, IT managers made the experience in the past that the most frequent reason for operational downtimes is due to problems with the electrical power : ICLMV20131003e Page 4/5

supply of the data centre. And her Siemens power distribution technology can help out by providing the utmost quality and reliability along the entire life cycle of a data centre. Despite a high reliability of supply, it is the distribution system operator (DSO) who is responsible again and again for an interruption to the power supply. The majority of these failures lasts less than a second so that they are hardly noticed. But even interruptions of more than ten milliseconds and voltage dips can impair IT operations and result in financial losses. Therefore, precision planning of safety power supply (SPS) and uninterruptible power supply (UPS) is of vital importance for data centres. Also for this requirement Siemens power supply solutions developed with preferred partners provides an stable and unmatched up-time. [1] Projecting Annual New Datacenter Construction Market Size; 2011 Microsoft [2] White paper # 6: Green Grid Data Center Power Efficiency Metrics: Pue and DCIE; 2008 The Green Grid [3] Code of Conduct on Data Centres Energy Efficiency Version 1.0; 2008 EU Commission DG JRC [4] DC Power for Improved Data Center Efficiency; 2008 Lawrence Berkeley National Laboratory Contact for journalists: Siemens AG Heiko Jahr, Tel.: +49 9131 7 29 575 E-Mail: heiko.jahr@siemens.com The Siemens Infrastructure & Cities Sector (Munich, Germany), with approximately 90,000 employees, focuses on sustainable technologies for metropolitan areas and their infrastructures. Its offering includes products, systems and solutions for intelligent traffic management, rail-bound transportation, smart grids, energy efficient buildings, and safety and security. The Sector comprises the divisions Building Technologies, Low and Medium Voltage, Mobility and Logistics, Rail Systems and Smart Grid. For more information, visit http://www.siemens.com/infrastructure-cities The Siemens Low and Medium Voltage Division (Erlangen, Germany) serves the entire product, system, and solutions business for reliable power distribution and supply at the low- and medium-voltage levels. The Division s portfolio includes switchgear and busbar trunking systems, power supply solutions, distribution boards, protection, switching, measuring and monitoring devices as well as energy storage systems for the integration of renewable energy into the grid. The systems are supplemented by communications-enabled software tools that can link power distribution systems to building or industry automation systems. Low and Medium Voltage ensures the efficient supply of power for power grids, infrastructure, buildings, and industry. Additional information is available at: http://www.siemens.com/powerdistribution : ICLMV20131003e Page 5/5