AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES

Similar documents
AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

Analysis of data centre cooling energy efficiency

State of the Art Energy Efficient Data Centre Air Conditioning

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Legacy Data Centres Upgrading the cooling capabilities What are the options?

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Direct Fresh Air Free Cooling of Data Centres

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Elements of Energy Efficiency in Data Centre Cooling Architecture

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Technical Systems. Helen Bedford

AIRAH Presentation April 30 th 2014

HVAC Infrastructure Retrofit Solutions

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Reducing Data Center Energy Consumption

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

DataCenter 2020: first results for energy-optimization at existing data centers

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers

The Different Types of Air Conditioning Equipment for IT Environments

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

White Paper: Free Cooling and the Efficiency of your Data Centre

- White Paper - Data Centre Cooling. Best Practice

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

News in Data Center Cooling

Improving Data Center Energy Efficiency Through Environmental Optimization

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

White Paper #10. Energy Efficiency in Computer Data Centers

European Code of Conduct for Data Centre. Presentation of the Awards 2013

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

STULZ View On DataCenter Cooling

Blade Server & Data Room Cooling Specialists

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

Defining Quality. Building Comfort. Precision. Air Conditioning

University of St Andrews. Energy Efficient Data Centre Cooling

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Webinar: Precision Cooling in Data Centres and other applications 24 June 2014

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

Free Cooling for Data Centers

Dealing with Thermal Issues in Data Center Universal Aisle Containment

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

FNT EXPERT PAPER. // Data Center Efficiency AUTHOR. Using CFD to Optimize Cooling in Design and Operation.

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Capgemini UK Infrastructure Outsourcing

Cooling kw Heating kw

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Knowledge for optimal efficiency

Element D Services Heating, Ventilating, and Air Conditioning

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Green Data Centre Design

Daikin Altherma Hybrid Heat Pump

HEATING, VENTILATION & AIR CONDITIONING

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Data Centre. Flexible, high efficiency cooling solutions. CONDITIONING CONDENSING UNITS CONTROLS SERVICE TRAINING

Eni Green Data Center - Specification

IBM Portable Modular Data Center Overview for Critical Facilities Round Table

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

How To Improve Energy Efficiency In A Data Center

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

TelecityGroup plc. Outstanding data centres. Expertise you can trust.

Design Best Practices for Data Centers

European Code of Conduct for Data Centre. Presentation of the Awards 2016

EHDC. Cooling system for Data Center and server cabinets.

How to Build a Data Centre Cooling Budget. Ian Cathcart

APC APPLICATION NOTE #112

Daikin Altherma Hybrid Heat Pump

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Alfa Laval Abatigo. Redefining adiabatic cooling

Daikin Altherma Hybrid Heat Pump

Scalable. Affordable. Flexible. Fast.

How To Benchmark Power Production

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

System solution for data centres

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods By: Daniel Kennedy

Transcription:

AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA

GLOBAL DATA CENTRE IP TRAFFIC WILL TRIPLE WITHIN 5 YEARS Global data centre IP traffic has set a constant growth path, with a CAGR of 25% during the period 2012-2017. In particular, the growth will be driven by three main factors: The need for bigger online storage resources; The new possibility to analyze a bigger amount of data (a phenomenon called big data analysis, applied in the analysis of complex systems such as weather forecasts or social behavior prediction); The growing demand for cloud requirements. Cloud data centre traffic will grow with a CAGR of 35% from 2012 to 2017, at a faster rate than the traditional IP traffic, establishing a 4,5-fold growth during this period. Zettabytes / Year Global cloud traffic crossed the zettabyte threshold in Year 2012, and by 2017 over two-thirds of all data centre traffic will be based in the cloud. Cloud traffic will represent 69% of total data centre traffic by 2017. Significant promoters of cloud traffic growth are the rapid adoption of and migration to cloud architectures, along with the ability cloud data centres offer in handling significantly higher traffic loads. This notable growth in data centre traffic will also transform into a significant growth in data centre air conditioning needs, which is expected to grow with a CAGR of about 12% till 2018. The market value will grow from the actual $ 4,91billion to $ 8,07 billion in 2018, doubling in size. 8 7 6 5 4 3 2 1 0 2,6 3,3 4,2 5,2 6,4 7,7 2012 2013 2014 2015 2016 2017 A HIGH ENERGY CONSUMPTION APPLICATION Data centres represent a high-density building typology, with a consequently very high power density. A data centre requires an average of 10-15 times more energy than a standard office building, at times reaching 40 times. In addition, the field of Information and Communication Technology (ICT) is one of the main causes of growth in energy consumptions in Europe. The density of the servers is in fact growing rapidly, and as a consequence so is the power demand of the air conditioning systems dedicated to them. The air conditioning of a server room represents a significant portion of the total energy consumption of the data centre, representing 31% of the total energy usage of the entire data centre. It is thus of paramount importance that the air conditioning system applied within data centres achieves the highest efficiencies and lowest energy consumptions. In fact an optimised data centre air conditioning solution represents a significant cost saving and powerful contribution to global carbon footprint reductions. Distribution of energy consumptions in a data centre 31% 4% 8% 11% 46% Air Conditioning Lighting UPS Server Others 2 Aermec

DATA CENTRE COOLING REQUIREMENTS Data centre cooling systems represent a significant portion of a facility s capital expenditure and use a substantial amount of energy. ASHRAE (American Society of Heating, Refrigerating, and Air-conditioning Engineers) publishes specific guidelines for temperature and humidity control within data centres. The 3rd Edition of the Thermal Guidelines for Data Processing Environments defines a recommended operating window and four allowable ranges, designated A1 though A4. The new allowable ranges (A3 and A4) are intended to remove obstacles to new data centre cooling strategies such as free cooling systems. Free-cooling takes advantage of a facility s local climate by using outside air to cool IT equipment either directly or via a cooling medium, avoiding the use of mechanical refrigeration whenever possible. Relative Humidity 90% 80% 70% 60% 50% 40% 30% 0 5 10 Saturation Temperature C 15 20 25 Class A1 Allowable envelope Classes A1-A4 Recommended envelope Class A2 Allowable envelope Class A3 Allowable envelope Class A4 Allowable envelope 0 0 10 20 30 40 50 20% 10% 20 15 10 5 Humidity Ratio - grams of moisture per kilogram of dry air Dry bulb temperature C ENERGY EFFICIENCY & PUE LEVELS: A MARKET SURVEY PUE (Power Usage Effectiveness) is a measure of how efficiently a computer data centre uses energy. Specifically, it measures how much energy is used by the computing equipment (in contrast to cooling and other overheads). It is defined as the ratio of the total amount of energy used by a data centre facility to the energy delivered to the computing equipment. The closer to a PUE of 1,0 the more efficient the data centre. A 2013 independent market survey defined that 41% of data centre CIOs reported their PUE was above or equal to 2,0, whilst the registered average PUE was 2,53. Only 1% of those interviewed reported their PUE was lower than 1,4. Current market average PUE = 2,53 PUE achieved by 1,40 only 1% of market Aermec 3

AERMEC: TECHNOLOGY YOU CAN TRUST Aermec, founded in 1961, counts amongst Europe s longest established Air Conditioning suppliers. A true pioneer, with over 50 years of innovative customer focused solutions, Aermec is present on all continents worldwide and with Subsidiaries and Affiliates in France, Germany, Italy, the Netherlands, Poland, Russia, Spain and the UK. The Aermec Group of companies includes a total of 6 centres of excellence spanning the full air conditioning portfolio, with a turnover in excess of 305m and over 1600 employees. A total of 8 Group manufacturing locations create the advanced product solutions Aermec offers its clientele. Aermec is well established in the data centre market, with a multiple year experience and prestigious projects aimed at reducing the overall cost of ownership of modern data centres. This process is achieved by applying state of the art product solutions with a strong focus on integrated design and sophisticated analyses of individual data centre customer requirements, with the aim of achieving a personalised and optimised solution for each and every individual installation site. Product quality is an Aermec hallmark. Premium components are utilised throughout, each unit exiting the Aermec factories undergoes meticulous testing processes, and numerous certifications including Eurovent, MCS, cul and AHRI testify to Aermec s attention to detail. 4 Aermec

2MW TESTING FACILITIES Aermec s 2MW testing facilities Aermec s advanced labs extend to 2MW cooling capacity per single unit in what is probably Europe s largest test facility, which will offer Eurovent certification. Specific labs within Aermec also cater for extreme temperature testing, ventilation and heat exchange measurements, noise level verification and vibration testing. Aermec furthermore utilizes a simulated data centre installation including both a data hall simulator and an ambient air simulator recreating typical ambient temperature and humidity conditions. AERMEC & DATA Aermec s experience in data centre cooling technologies spans many years and countless individual projects in a total of 17 nations. In fact in the last 3 years alone Aermec has installed roughly 1000MW of air conditioning into the data centre market. Aermec s expert professional project approach, combined with system efficiency and reliability, renders Aermec a natural choice in data centre applications. Aermec s main manufacturing facilities near Verona, Italy EXPERT SUPPORT AT ALL TIMES Aermec offers a focused technical support during all stages within the project, accompanying its customers in strategic data centre decisions and providing a full portfolio of services at every stage, including: System energy efficiency analysis using innovative energy simulation softwares; Aermec allows customers to evaluate the overall system efficiency in order to obtain the lowest possible PUE. Accurate real operation condition witness tests in Aermec s advanced testing laboratories, allowing customers to validate the performance of the units prior to start-up. Safety in time: evolved devices supplied with the system allow 24/7 control and supervision of the systems, even remotely, ensuring maximum reliability and peace of mind. Aermec service personnel are available at all times for fast and efficient troubleshooting and on-site interventions. Aermec 5

DATA DATA CENTRE DESIGN SOLUTIONS According to the specific data centre characteristics, the geographical and thus ambient conditions in which the data centre is located, and the individual target requirements of the User, differing data centre cooling typologies can be applied. Air return Air return CRAH CRAC Condenser or Dry Cooler Chiller Air supply Air supply CHILLED WATER SYSTEMS DIRECT EXPANSION SYSTEMS Precision Air Conditioners featuring one or more chilled water coils (CRAH), operating in combination with one or more external water chillers. The water chiller can be in standard or freecooling configuration. In alternative to the CRAH units, which are generally positioned peripherally to the server rack, In-Rack conditioners can be utilised, which supply air conditioning within the server racks themselves. Precision Air Conditioners featuring one or more direct expansion circuits (CRAC), either in air-cooled configuration with external condensers or in water-cooled configuration with external dry coolers. In alternative to the CRAC units, which are generally positioned peripherally to the server rack, In-Rack conditioners can be utilised, which supply air conditioning within the server racks themselves. AIr return Cooling units with direct exchange Air expulsion Air return Cooling units with indirect exchange Air expulsion External air intake Air supply Integration chiller 6 Air supply DIRECT COOLING SYSTEMS ADIABATIC INDIRECT COOLING SYSTEMS Air Handling Units featuring a cooling circuit which introduces cold air directly into the data centre and expels hot air to ambient. Fresh air is mechanically distributed into the data centre via ducting. Direct cooling systems are integrated with filters and may feature additional forms of adiabatic cooling or dehumidification. Packaged units which expel heat from the data centre by passing it through a heat exchanger where it exchanges with ambient air, creating free-cooling. Adiabatic cooling is utilised to support the cooling process at higher ambient temperatures. Mechanical cooling may be supplied as a top-up beyond the standard cooling process. Aermec

DESIGNING YOUR OPTIMISED DATA CENTRE An optimised data centre starts with a clear vision as to the overall project objectives: Aermec s unique ACES energy simulation software supports this process by evaluating the performances of differing data centre solutions. ACES considers variable loads and all year round operation, evaluating climate profiles and cooling loads. The load demand profile is defined by the specific server requirements, including primary circuit pumping. The instantaneous efficiencies of each proposed system are calculated using complex algorithms which account for both differing loads and water and ambient temperatures, maximizing efficiency and chiller cycling whilst accounting for the total Precision Air Conditioner (PAC) load needs at specific ambient temperatures and load levels. All factors causing possible efficiency losses are accounted for, including chiller switching sequences, pump input powers and PAC operation. ACES calculates the efficiencies of each individual solution and the resulting efficiency of the whole system. ACES considers the current and future installation site design, the required cooling load, the climatic profile, the use of the facility, potential renewable energy integrations, the available space, noise constraints, redundancy, maintenance needs and more beyond. Ambient Tª (ºC) All of these inputs are considered to generate a customized and optimized proposal. ACES furthermore cross compares the performance of multiple chillers, the PAC system, AHU and server control devices, primary and secondary pumping equipment, system lay out, etc. ACES accounts for the complications created by the multiple variables, applying an interactive analysis process which calculates the best possible solution considering all the involved variables. Ambient Tª (ºC) 25.0 20.0 15.0 10.0 5.0 25.0 20.0 15.0 10.0 5.0 0.00 0.00 2 2 4 4 6 6 8 8 10 10 12 12 14 14 Hours Hours of the day of the 16day 16 18 18 20 20 22 22 AMBIENT AMBIENT TEMPERATURE PROFILE PROFILE Delta OF Delta T K T K Jan JanFeb March March April May July Sept Nov May June JulyAug Sept Oct NovDec Feb April June Aug Oct Dec ACHIEVING THE LOWEST ppue Aermec data centre systems are capable of achieving market leading ppue levels, offering significant reductions in carbon footprints and energy consumptions. More specifically Aermec chiller solutions applying Dynamic Setpoint can achieve a ppue down to 1,07 in a London data centre, with an IEC Indirect Evaporative Cooler in the same location achieving ppue = 1,04. Traditional free cooling chillers by contrast generally achieve ppue = 1,80, with the market average being 2,10. ppue 1,04 ppue 1,07 ppue 1,80 ppue 2,10 DATA CENTRE CFD ANALYSES Aermec CFD simulations, customized to customers individual data centre designs, offer an important simulated consultancy which spans beyond the single components. These allow specific hot spots to be identified, verify the opti mised distribution of air and cooling loads and offer an important contribution within the establishment of the most efficient overall data centre design solution. Aermec 7

THE AERMEC DATA CENTRE SOLUTIONS WATER CHILLERS NS_I Aermec water chillers offer a wide range of cooling capacities to meet the needs of small, medium and large data centres. Free-cooling technology exploits the favourable environmental conditions to supply chilled water without the use of mechanical cooling, maximizing efficiencies and energy savings. NS_I (260-1300kW) Chillers with inverter screw compressors Shell & tube heat exchangers Water available at -6 C to +15 C Standard and free-cooling configurations TBX NSM_HWT TBX (260-860kW) Chillers with Turbocor compressors featuring magnetic levitation Shell & tube heat exchangers Water available at +5 C to +18 C NSM_HWT (250-1600kW) Chillers with screw compressors Shell & tube heat exchangers Water available up to +30 C with external air temperatures up to +46 C Standard, free-cooling and glycol-free configurations PRECISION AIR CONDITIONERS Aermec s wide range of Precision Air Conditioners cater for the differing data room conditioning needs. Efficient and flexible product solutions can be applied within numerous differing configurations. A wide range of options and accessories allows perfect alignment according to the needs of individual installations, providing complete and optimised control of the temperature, humidity and indoor air quality within data centres. AIR-COOLED DIRECT EXPANSION CONFIGURATIONS Cooling range 6 180kW Down-flow and Up-flow versions DC inverter compressors, EC fans, electronic expansion valves WATER-COOLED DIRECT EXPANSION CONFIGURATIONS Cooling range 6 180kW Down-flow and Up-flow versions DC inverter compressors, EC fans, electronic expansion valves CHILLED WATER CONFIGURATIONS Cooling range 10 300kW Down-flow and Up-flow versions EC fans 8 Aermec

IN - RACK UNITS Aermec s In-Rack Precision Air Conditioners are positioned within the data hall. In contrast with CRAC and CRAH units, which are generally positioned in peripheral areas within the data hall, In-Rack units are positioned within the server racks themselves, providing a highly effective localised cooling right where it is needed. Both direct expansion (20 40kW) and chilled water (10 40kW) solutions are offered. REMOTE CONDENSERS AND DRY COOLERS Aermec direct expansion Precision Air Conditioners find their ideal external cooling source when combined with the extensive range of Aermec remote condensers (for air-cooled solutions) and dry coolers (for water-cooled solutions). Horizontal and compact V-coil configurations are available, with a multitude of options and accessories for all individual needs. The highly robust design is ideal for year-round data centre operation. UNDERFLOOR UNITS UFB offers localised micro-climate air conditioning support within critical areas in the data hall. Installed within the raised floor and thus creating no intrusion, it supplies fresh underfloor air into the data hall when needed, as determined by an on-board controller; alternatively UFB recirculates the air within the data hall itself. Integrated filters are standard, with an electrical heater as an option. UFB can be easily repositioned within the data hall, occupying the exact dimensions of a single raised floor panel. INDIRECT EVAPORATIVE COOLERS IEC is a fully packaged air conditioning unit which removes heat from the data hall return air and rejects this to ambient via a heat exchange process, subsequently returning the suitably cooled air back into the data hall via a highly energy efficient free-cooling process. An adiabatic spray system preceding the heat exchanger within the ambient air circuit intervenes when ambient conditions require it, operating in support of the freecooling. Optional mechanical cooling is offered and intervenes as top-up cooling together with the free-cooling and adiabatic cooling processes. Aermec 9

AERMEC CHILLERS ENSURE LOWEST PUE S Dynamic Set Point Dynamic Set Point (DSP) automatically and continuously optimises chilled water outlet temperatures as ambient and IT loads vary, ensuring the highest amount of free cooling is achieved all year round. DSP s control algorithm affords maximum efficiency across the widest operating spectrum. By optimising the efficiency characteristics of single compressor, DSP ensures each compressor works at its peak performance (as opposed to systems where each compressor is loaded up once the full load per circuit is reached). Freecooling is maximised by allowing chilled water outlet temperatures to rise to 30 C using uniquely developed compressors. Furthermore, DYNAMIC SET POINT specifically redesigned Precision Air Conditioner water coils cater for low load scenarios, overcoming laminar flow issues, with DSP fully exploiting the resilience DYNAMIC SET POINT designed into the system at low load conditions. DSP noticeably reduces Carbon Footprints whilst allowing flexibility in build programs and load profiles, with a plug and play philosophy allowing modules to be added as and when client IT loads increase. DSP is rapidly proving itself to be the most energy efficient chilled water system available. Cumulative hours London (UK) 700 600 500 400 300 200 100 of the year spent in free-cooling -5.0 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 Ambient Temperature ( C) Data refers to London (UK) for a 350kW chiller operating with chilled water at 18/24 C 21% 75% Total free-cooling 21% Partial free-cooling 4% Mechanical cooling The most evolved free-cooling technologies Free-cooling translates into cooling for free, the more this can be exploited the higher the energy savings. Aermec optimises free-cooling, a concept whereby ambient air is used for cooling when the ambient temperature is lower than the data hall air (direct free-cooling) or the chilled water (indirect free-cooling). In hydronic solutions free-cooling starts when external conditions ensure even a minimum coverage of the thermal load requirements, applying modulating free-cooling to maximize the free external source; the percentage of free-cooling increases proportionally in relation to the temperature difference between the internal and external environments, thus notably reducing the contribution of mechanical cooling and maximizing overall system efficiency. 4% Supervision & Connectivity Solutions Multichiller sequence controlling manages the entire system, evaluating the effective load request to achieve the best overall system efficiency, optimising free-cooling and ensuring tight temperature control. Aermec data centre solutions can furthermore be easily and fully integrated with BMS and Supervisor systems (LONWORKS, BACNET, MODBUS, etc.) to ensure an optimised and simplified system overview. Optimised system architecture When the powers involved are high, significant energy savings can be obtained by ensuring optimised cooling of the data room. Aermec applies its unique Hot Aisle Containment HT (High Temperature) design solution, allowing higher operating temperatures in accordance with ASHRAE data centre operating envelopes, thus notably increasing the overall efficiency of the system. Thermal energy recovery Aermec chillers allow for the recuperation of the heat within the system, which can then be made available for auxiliaries and other peripheral functions. This free-heating solution offers a further additional energy saving potential within the overall data centre solution. 10 Aermec

IEC: HIGHEST ENERGY EFFICIENCIES IEC applies free-cooling using ambient air for the majority of its operation, adding adiabatic cooling only when required. Mechanical cooling is generally totally avoided, as per the example showing the operating area for a typical data centre in Frankfurt (Germany), where mechanical cooling can be avoided altogether. IEC operating area in Frankfurt (Germany) SC 10-15 -10-5 0 5 10 15 Saturation Temperature C 20 25 30 90% 80% AC 70% 60% 50% Relative Humidity % 40% 0,030 0,025 0,020 0,015 0,010 0,005 0,000 15 20 25 30 35 40 45 50 55 60 30% 20% MC 10% Humidity Ratio - grams of moisture per kilogram of dry air Dry bulb Temperature C STANDARD COOLING (SC) takes place when the ambient air temperature lies below the indoor air temperature. The external air passes through the heat exchanger, thus removing heat from the data centre. No adiabatic cooling is required, due to the advantageous external temperature conditions. ADIABATIC COOLING (AC) uses adiabatic water sprays preceding the heat exchanger to pre-cool the ambient air and thus boost the standard cooling process. The water entering the air flow evaporates, thus increasing the heat exchanger s heat rejection capacity, improving system efficiency MECHANICAL TOP-UP COOLING (MC, optional) uses refrigeration or chilled water. Mechanical cooling rarely operates, if at all, in those conditions where external temperatures are too high, and always operates together with both standard and adiabatic cooling, adding a percentage of additional cooling. ADVANCED PRECISION AIR CONDITIONERS Free-cooling operation Beyond CRAH units combined with free-cooling chillers, direct expansion CRAC units can also operate in either total or partial free-cooling. CRAC free-cooling solutions offer notable energy savings. Twin source cooling Aermec Precision Air Conditioners are available with twin source operation, either in configurations allowing both direct expansion and chilled water operation using a single unit, or by applying two distinct chilled water sources. Lowest partial load energy consumptions Inverter driven compressors offer a complete power variability for perfect control and lowest energy use. This is combined with electronic expansion valves ensuring further partial load savings. Brushless EC fans are applied again to notably reduce power usage at partial load conditions. Design by density Differing data centres present differing densities. Low, medium and high density applications each present distinct challenges and correspondingly distinct optimised solutions. The complete range of Aermec Precision Air Conditioners cover the specific needs these various scenarios present. Aermec 11

Aermec S.p.A. Via Roma, 996 37040 Bevilacqua (VR) - Italia Tel. + 39 0442 633111 Fax +39 0442 93577 marketing@aermec.com www.aermec.com All specifications are subject to change without prior notice. Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions.