Interoperability List IEC 60870-5-103 REG-P. Creation Date: 28/04/2003 Release Date: 21/05/2013 Release: V1.4



Similar documents
INTERNATIONAL STANDARD

Voltage Regulator SPAU 341 C. Product Guide

Special Publication. Operation and Monitoring of MSCDN-Systems

INDEX. IEC Controlled Station Interoperability com.tom WEB-PLC 8.0.2

SAGE Sistema Aberto de Gerenciamento de Energia. Documento de Interoperabilidade do Protocolo IEC/ no SAGE

Trip circuit supervision relay. Type RXTCS

CONFIGURABLE SAFETY RELAYS

Secure My-d TM and Mifare TM RFID reader system by using a security access module Erich Englbrecht (info@eonline.de) V0.1draft

SCADAPack E IEC Interoperability Profile Documents

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

FACTORY AUTOMATION MANUAL ID-NET SETUP PROCEDURE USING PROGRAMMING BARCODES

KNX Panasonic Air Conditioners

SUBJECT: APPENDIX A2: MESSAGES PER BUSINESS DOMAIN DDNEA FOR EMCS PHASE 3 (ECP3-FITSDEV3-SC01-DDNEA_P3_APP_A2)

CONFIGURABLE SAFETY RELAYS

Current and voltage measuring relays

How To Configure An Iec (Runtu) For A Testnet (Rntu)

Protection and Substation Automation. Training Programmes

Rack mounted telephone- and leased line modem for industrial applications

IntesisBox Modbus Server SAMSUNG Air Conditioners

T Substation Maintenance and Commissioning Test Equipment

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

User's Guide bintec R4100 / R4300 Serial Unit. Copyright July 17, 2006 Funkwerk Enterprise Communications GmbH Version 0.9

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

IntesisBox KNX LG Air Conditioning

Date Rev. Details Author

Power network telecommunication

SECTION DETECTION AND ALARM

Capacitor Protection Relay SPAJ 160 C. Product Guide

M-Bus-Logger Data Logger

Implementation of a New Substation Restoration System Using Protective Relays and a Logic Processor

This recommendation was prepared by the Technical Commission of EUROMAP.

Comparison of protocols used in remote monitoring: DNP 3.0, IEC & Modbus

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Technical Specification Of Substation Protection & Control System with IEC BHEL s Perspective

Network Analyzer for Low-, Medium- and High-Voltage Networks

Auxiliary equipment for communication with the EuroProt protective devices

RS - SPM. Serial parallel translator module

Remote Monitoring and REC 501 Control Unit Product Guide

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

IntesisBox KNX Modbus RTU master

How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (

EGCP-3 MC Revision H Software Revision F. Explanation of Software Changes Made for the EGCP-3 MC Control. Application Note 51298

A DNP3 Protocol Primer

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Disturbance Recoder SPCR 8C27. Product Guide

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

RPDO 1 TPDO 1 TPDO 5 TPDO 6 TPDO 7 TPDO 8

Modbus Server SAMSUNG Air Conditioners

Inwall 4 Input / 4 Output Module

CALL MANAGER INSTALLATION

IntesisBox Modbus Server Fidelio IP

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

XP Series Balances Operation Manual

PREMIUM CLEAN ROOM MONITOR MODELS 8630-CRM-S 8630-CRM-P

Telephone- and leased line modem for industrial applications TD-36

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Inwall Room Temperature Unit

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

Catalog. Arc Guard System TM TVOC-2

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

Power network telecommunication

O pen F ram e Tou c h M on i t or

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

Three-phase monitoring relay CM-PFE

Evaluation Board. i-modul and Socket. Manual

1-Port R422/485 Serial PCIe Card

Barcode Reader Series BCL 31, BCL 32, BCL 34

Comparative Market Analysis of Project Management Systems

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

User Manual Revision English

Communication Unit 560CMU05 Data sheet

Addendum to the Operating Instructions

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:



Copyright 1980 by the Association for Supervision and Curriculum Development. All rights reserved.




PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

LDCDP GdW. L force Controls. Ä.GdWä. Software Manual. Industrial PC. WindowsR CE Thin Client. Operating system

Teleprotection Schemes and Equipment. James W. Ebrecht Young Power Equipment Scottsdale, AZ

Electric Rotary Actuator - On/Off or programmable control actuator

ICP-CP500. User's Guide ICP-CP500 Codepads

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Pressure Switch for gas and air

OPT SERIAL TO FIBER OPTIC CONVERTER

ABB i-bus KNX Switch Actuators SA/S Product Information

Computer Gateway Specification and Technical Data

ELCOMPONENT LTD. User Manual

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Information Board User s Guide

Transcription:

Interoperability List IEC 60870-5-103 REG-P g Creation Date: 28/04/2003 Release Date: 21/05/2013 Release: V1.4

We take care of it. History of document Author Department Phone Version Date Wolfgang Borchers Fa. TELE-DATA (+49) (0) 911 628 108 95 V0.1 28/04/1999 Wolfgang Borchers Fa. TELE-DATA (+49) (0) 911 628 108 95 V1.0 28/08/2003 Wolfgang Borchers Fa. TELE-DATA (+49) (0) 911 628 108 95 V1.1 03/02/2002 Wolfgang Borchers Fa. TELE-DATA (+49) (0) 911 628 108 95 V1.2 16/05/2013 Distribution list Name Department Location Phone Mr. Schobert a.eberle Nuremberg (+49) (0) 911 628 108 48 Mr. Haussel a.eberle Nuremberg (+49) (0) 911 628 108 77 Mr. Straussberger a.eberle Nuremberg (+49) (0) 911 628 108 76 Mr. Sybel a.eberle Nuremberg (+49) (0) 911 628 108 70 The persons responsible for establishing the agreed contents of this document are: Name Department Location Phone Signature Date Mr. Borchers www.a-eberle.de Nuremberg (+49) (0) 911 628 108 95 16/06/2013 The persons responsible for establishing this document are: Name Department Location Phone Signature Date Mr. Sybel a.eberle Nuremberg (+49) (0) 911 628 108 70 Mr. Straussberger a.eberle Nuremberg (+49) (0) 911 628 108 76 Page 2

Document changes/updates (The overview contains only the changes concerning the released/distributed document) Changed chapters /pages Responsibility Version Reason of change / change request All chapters Borchers 1.0 Review All chapters Borchers 1.1 Baud rate corrected, increased set-point types, measurand type 11 and 12, new company profile LEREF "Verzeichnis Ueberschrift" \* MERGEFORMAT Index Fehler! Verwenden Sie die Registerkarte 'Start', um Verzeichnis Ueberschrift Page 3

We take care of it. 1 Interoperability list... 5 1.1 Physical Iayer... 5 1.1.1 Electrical Interface... 5 1.1.2 Optical interface... 5 1.1.3 Transmission speed... 5 1.2 Application Iayer... 6 1.2.1 Transmission mode for application data... 6 1.2.2 COMMON ADRDESS of ASDU... 6 1.2.3 Selection of standard information numbers in monitor direction... 6 1.2.4 Selection of standard information numbers in control direction... 10 1.2.5 Basic application functions... 10 1.2.6 Miscellaneous... 10 Page 4

1. Interoperability list 1.1 Physical Iayer 1.1.1 Electrical Interface EIA RS-485 EIA RS-232 10-20mA 1.1.2 Optical interface Glass fibre Plastic fibre,please order separately F-SMA type connector ST type connector 1.1.3 Transmission speed 100 bit/s 200 bit/s 300 bit/s 600 bit/s 1200 bit/s 2400 bit/s 4800 bit/s 9600 bit/s 19200 bit/s LEREF "Verzeichnis Ueberschrift" \* MERGEFORMAT Index Fehler! Verwenden Sie die Registerkarte 'Start', um Verzeichnis Ueberschrift Page 5

We take care of it. 1.2 Application Iayer 1.2.1 Transmission mode for application data Mode 1 (least significant octet first), as defined in 4.10 of IEC 60870-5-4, is used exclusively in this companion standard. 1.2.2 COMMON ADRDESS of ASDU One COMMON ADDRESS OF ASDU (identical with station address) 1.2.3 Selection of standard information numbers in monitor direction System functions in monitor direction INF Semantics <0>:= End of general interrogation <1>:= Time synchronization <2>:= Reset FCB <3>:= Reset CU <4>:= Start/restart <5>:= Power on Status indications in monitor direction INF Semantics <16:= Auto/Man, Rückmeldung Hand/Auto <17:= Teleprotection active <18:= Protection active <19:= LED reset <20:= Monitor direction blocked <21:= Test mode <22:= Local parameter setting <23:= Characteristic 1 <24:= Characteristic 2 <25:= Characteristic 3 <26:= Characteristic 4 <27:= Auxiliary input 1 <28:= Auxiliary input 2 <29:= Auxiliary input 3 <30:= Auxiliary input 4 <31:= running tap, Lauflampe Page 6

Supervision indications in monitor direction <32:= 24V Automat <34:= Lauflampe MaxZeit <35:= Parallelprogramm läuft j/n <36:= >U j/n <37:= <U j/n <38:= Schnellschaltung j/ <39:= Auslösung j/n <40:= Stillsetzung j/n <47:= Group a!arm Fault indications in monitor direction <44>:= U > <45>:= U < <46>:= I > <49>:= Error regulator <50>:= Verzögerungsart linear/integral <51>:= Regelverzögerung2 ein/aus <52>:= Anzeige V/kV <53>:= Meßschaltung A/C <54>:= Stufenstellung / Tap position (wird im Meßwertblock übertragen) REG-P specifics in control direction <55:= Rated value 1, Sollwert 1 <56:= Rated value 2, Sollwert 2 <57:= Rated value 3 <59:= <60:= Delay 1 <61:= Delay 2 <62:= U < LEREF "Verzeichnis Ueberschrift" \* MERGEFORMAT Index Fehler! Verwenden Sie die Registerkarte 'Start', um Verzeichnis Ueberschrift Page 7

We take care of it. Fault indications in monitor direction <64>:= U> <65>:= Überspannung max. <66>:= Unterspannung max. <67>:= Schnellregelung rück <68>:= Schnellregelung vor <69>:= Kreisblindstrom max. <70>:= <71>:= <72>:= K-factor <73>:= Factor adjust-kv <74>:= UX <75>:= UR <76>:= Loadshedding 1 <77>:= Loadshedding 2 <78>:= Loadshedding 3 <79>:= <80>:= Zone 3 <81>:= Zone 4 <82>:= Zone 5 <83>:= Zone 6 <84>:= General start/pick-up <85>:= Breaker failure <86>:= Trip measuring system L 1 <87>:= Trip measuring system L 2 <88>:= Trip measuring system L 3 <89>:= Trip measuring system E <90>:= Trip I> <91>:= Trip I>> <92>:= rip IN> <93>:= Trip IN>> Page 8

Auto-reclosure indications in monitor direction <128>:= CB on' by AR <129>:= CB on' by long-time AR <130>:= AR blocked Measurands in monitor direction <144>:= Measurand <145>:= Measurands I, V <146>:= Measurands l, V, P, 0 <147>:= Measurands I N. V EN <148>:= Measurands I L1,2,3, V L1,2,3, P, Q,f Generic functions in monitor direction <240>:= Read headings of all defined groups <241>:= Read values or attributes of all entries of one group <243>:= Read directory of a single entry <244>:= Read value or attribute of a single entry <245>:= End of general interrogation of generic data <249>:= Write entry with confirmation <250>:= Write entry with execution <251>:= Write entry aborted LEREF "Verzeichnis Ueberschrift" \* MERGEFORMAT Index Fehler! Verwenden Sie die Registerkarte 'Start', um Verzeichnis Ueberschrift Page 9

We take care of it. 1.2.4 Selection of standard information numbers in control direction System functions in control direction INF Semantics <0>:= lnitiation of general interrogation <0>:= Time synchronization General commands in control direction INF Semantics <16>:= Auto/Man, Umschaltung Hand / Auto <17>:= higher tap, Trafo höher <18>:= lower tap, Trafo tiefer <55>:= Rated value 1 select, Sollwert1 aktivieren <56>:= Rated value 2 select, Sollwert2 aktivieren <57>:= Rated value X select, X= 1..4, Sollwertanwahl als Messwert <65>:= Grenzwert Überspannung 1.2.5 Basic application functions Test mode Blocking of monitor direction Disturbance data Generic services Private data 1.2.6 Miscellaneous Measurands are transmitted only in case of a modification of any measurand of described block. Page 10

Page 11

A. Eberle GmbH & Co. KG Frankenstraße 160 D-90461 Nuremberg Germany Tel.: +49 (0) 911 / 62 81 08-0 Fax: +49 (0) 911 / 62 81 08 96 E-Mail: info@a-eberle.de http://www.a-eberle.de Software - Version: Copyright 2013 by A. Eberle GmbH & Co. KG Subject to change without prior notice. REG-PE(D) Interoperability List IEC 60870-5-104