NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES SELON LES NORMES SUIVANTES... > AIRBUS > BOEING > DO 160 Section 16 > EN 61000-3-11 > EN 61000-3-12 > EN 61000-3-2 > EN 61000-3-3 > EN 61000-4-13 > EN 61000-4-14 > EN 61000-4-17 > EN 61000-4-27 > EN 61000-4-28 > EN 61000-4-29 > IEC 61000-3-11 > IEC 61000-3-12 Ed.2:2011 > IEC 61000-3-2 > IEC 61000-3-3 > IEC 61000-4-13 > IEC 61000-4-14 > IEC 61000-4-17 > IEC 61000-4-27 >... NETWAVE - SIMULATION OF THE MOST REQUIRED POWER SUPPLY PHENOMENON The NetWave Series are three-phase AC/DC power source, specifically designed to meet the requirements as per the standards IEC/EN 61000-4-13, -4-14, -4-27(*) and -4-28. It is also used as a DC power source to cover the requirements as per the standards IEC/EN 61000-4-17 (Ripple on DC) and IEC/EN 61000-4-29 for voltage dips and interruptions on DC supplies. The NetWave series is well suited for testing inverters (e.g. solar power, wind power) and e-vehicles. Additionally, the NetWave series offers the necessary capabilities for avionics testing as per DO-160, Airbus ABD0100 and Boeing as well as per MIL-STD-704. Optionally the NetWave 3-phase series can be equipped with a power-recovery module to absorb fed-back power (AC/DC) up to nominal power of the NetWave. (*) pre-compliant HIGHLIGHTS > Wide Power Bandwidth; DC - 5kHz > Output Power up to 60,000VA AC / 72,000W DC > Output Voltage up to 3*360V AC (p-n), +/-500V DC > High Inrush Current Capability > Power-recovery up to nominal power (optional) DOMAINES D'APPLICATION INDUSTRIE MÉDICAL RÉSIDENTIEL AÉRONAUTIQUE MILITAIRE ENERGIES RENOUVELABLES www.emtest.com EM TEST > PAGE 1/5
MODEL OVERVIEW TECHNICAL DETAILS 3-PHASE NETWAVE-MODELS NetWave 20.x NetWave 30.x NetWave 60.x TECHNICAL DETAILS 22,500VA AC / 27,000W DC 30,000VA AC / 36,000W DC 60,000VA AC / 72,000W DC NETWAVE 60 NETWAVE 60.2* (@ 66A (RMS) continuous 100A (RMS) short-term (max. 3s) 400A repetitive peak 66A (RMS) continuous 100A (RMS) short-term (max. 3s) 400A repetitive peak NETWAVE 20 NETWAVE 20.2* (@ NETWAVE 30 NETWAVE 30.2* (@ 26A (RMS) continuous 47A (RMS) short-term (max. 3s) 200A repetitive peak 26A (RMS) continuous 47A (RMS) short-term (max. 3s) 200A repetitive peak 33A (RMS) continuous 66A (RMS) short-term (max. 3s) 250A repetitive peak 33A (RMS) continuous 66A (RMS) short-term (max. 3s) 250A repetitive peak * EXTENDED CAPABILITIES FOR NETWAVE 20.2 / 30.2 / 60.2 MODELS Simple mode SourceAC mode Ramp Up/Down Segment "Step" Extern mode Control via MatLab to integrate the NetWave into existing automation environments PLL synchronization with other voltage sources Extended trigger functions Increase/decrease of the main line voltage in fixed steps Ramping of voltage and/or frequency in constant time windows Control of the NetWave by an external control signal POWER RECOVERY (OPTIONAL HARDWARE MODULE) Mains voltage Recoverable power NetWave 20.x NetWave 30.x NetWave 60.x Power factor Available for all 3-phase NetWave models 400V +/- 10% (45Hz - 65Hz) up to nominal AC/DC power of the individual NetWave model Max. 22.5kVA AC / 27kW DC Max. 30kVA AC / 36kW DC Max. 60kVA AC / 72kW DC > 0.92 (cos phi) www.emtest.com EM TEST > PAGE 2/5
GENERAL DATA (ALL MODELS) GENERAL DATA (ALL MODELS) SPECIFICATIONS Output frequency Frequency accuracy, stability Output connectors Interfaces REGULATION Voltage sense DC - 5,000Hz 100ppm Safety lab connectors CEE type 32A (only for NetWave 20.x and NetWave 30.x) GPIB Ethernet RS 232 (input from DPA analyser) Frame bus (internal system bus) Internal or external, 4 wires Distortion (THD) Less than 0.5% Better than 0.1% Stability Better than 0.1% Accuracy Better than 0.5% Max. compensatable drop on wires Current limiter Protection WAVEFORM GENERATOR Segment types DC Segment types AC Segment duration 5% f.s. 5A to Imax for f < 75Hz Over current Over voltage Over temperature Low voltage DC, Ramp, Square, Triangle, Sawtooth, Step, Sine, Sine sweep, Sine ramp, Damped sinewave, Sine ripple, Profile, Square sweep, Noise, Sine Dwell, Sinc, Harmonic, Exponent... Sine, Modulation, Sine sweep, Sweep on Sine, Sine up/down, Sine unbalance, Overswing, Sine offset, Sine Dip, Harmonic, Interharmonic, Interharmonic step, Harmonic distortion... Unlimited DISPLAY AND CONTROLS Display LED indicators Operation TRIGGER AND DUT MONITORING DUT monitors DIMENSIONS Housing Weight Size MAINS Supply voltage Input current Line frequency Connectors AMBIENT CONDITIONS 2-Line LCD, 40 characters Power On Active output channel Functional status hard disk 6 function keys, Test On key: ON/OFF key for the power source 2 inputs, 2 outputs 2 inputs, configurable Frame approx. 650kg (NetWave 20.x) approx. 650kg (NetWave 30.x) approx. 1,000kg (NetWave 60.x) approx. 1670 x 920 x 750mm (NetWave 20.x) approx. 1670 x 920 x 750mm (NetWave 30.x) approx. 1800 x 1200 x 1000mm (NetWave 60.x) 3 x 400V (3P,N,PE); optional 3 x 208V (3P,N,PE) 32A/63A (NetWave 20.x)* 48A/75A (NetWave 30.x)* 96A/160A (NetWave 60.x)* * the higher figure represents the 3s short-term current 45Hz - 65Hz Temperature 0 C - 40 C Rel. humidity CEE type 63A (NetWave 20.x) Screwed terminals (NetWave 30.x and NetWave 60.x) 10% - 90%, non condensing www.emtest.com EM TEST > PAGE 3/5
OPTIONS OTHER SOLUTIONS OPTIONAL SOFTWARE NW3 License 1 NW3 License 2 NW3 License 3 Software license for DO-160 standard for NetWave-series Software license for MIL-STD-704 standard for NetWave-series Software license for Airbus standards for NetWave-series OTHER MODELS NetWave Series (1-phase) OTHER EQUIPMENT DPA 503N AIF 503N16 AIF 503N32 AIF 503N63 AIF 503N75 Single phase Multifunction AC/DC Power sources, up to 7,500VA AC and 9,000W DC 3-phase Harmonics and Flicker analyzer 3-phase flicker impedance, 3x400V, 16A 3x400V, 32A 3x400V, 63A 3x400V, 75A www.emtest.com EM TEST > PAGE 4/5
COMPÉTENCE DANS TOUS LES DOMAINES CONTACTEZ DIRECTEMENT EM TEST Suisse EM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Téléphone +41 (0)61/7179191 > Fax +41 (0)61/7179199 Internet: www.emtest.ch > E-mail: sales.emtest@ametek.com Allemagne EM TEST GmbH > Lünener Straße 211 > 59174 Kamen > Deutschland Téléphone +49 (0)2307/26070-0 > Fax +49 (0)2307/17050 Internet: www.emtest.com > E-mail: info@emtest.de France EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > 68200 Mulhouse > France Téléphone +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55 Internet: www.emtest.fr > E-mail: info@emtest.fr Pologne EM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska Téléphone +48 (0)518 64 35 12 Internet: www.emtest.com/pl > E-mail: info.polska@emtest.de USA / Canada EM TEST USA > 9250 Brown Deer Road > San Diego > CA 92121 Téléphone +1 (858) 699 1685 > Fax +1 (858) 458 0267 Internet: www.emtest.com > E-mail: sales.emtest@ametek.com Chine E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China Téléphone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38 Internet: www.emtest.com > E-mail: info@emtest.com.cn République de Corée EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Téléphone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr Les informations sur l\'étendue de la livraison, la présentation visuelle et les données techniques correspondent à l\'état de développement du produit au moment de la mise en circulation de la fiche technique. Les données techniques sont susceptibles de changement sans préavis. www.emtest.com EM TEST > PAGE 5/5