TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO
|
|
|
- Brendan McDonald
- 10 years ago
- Views:
Transcription
1 TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO SELON LES NORMES SUIVANTES... > ISO :2004 > ISO :2011 TEST SET FOR THE MEASUREMENT OF AUTOMOTIVE TRANSIENT EMISSIONS AS PER ISO 7637 The measurement of automotive transient emissions as per ISO requires an electronic switch, a mechancical switch and an artificial network. The electronic switch generates slow transients while the mechanical switch, a typical relay used in the vehicle, generates the fast transients. The artifical network represents the typical impedance of the wiring harness. The AN 200N100 is designed to meet the requirements of ISO , CISPR 25 / ISO and CISPR and can be switched accordingly. HIGHLIGHTS > BS 200N100 - Electronic switch, 60V DC/100A: DOMAINES D'APPLICATION AUTOMOBILE > - Volt.Drop <1.2V@100A, <0.2V@25A > - Peak voltage max. 1,000V > - Reverse-polarity/short-circuit protected > BSM 200N40 - Mechanical switch, 12/24V DC/40A > AN 200N100 - ISO , CISPR 25, CISPR > - Frequency range 100kHz - 125MHz > - 1,000V DC, 250V AC (up to 1kHz) EM TEST > PAGE 1/5
2 TRANSIENT EMISSION SET - THE BENEFITS MULTI-PURPOSE AN 200N100 The EM TEST Transient Emission Set consisting of the BS 200N100 electronic switch, the artificial network AN 200N100 and the BSM 200N40 mechanical switch is an easy-to-use, economic and compact solution, fully compliant to ISO Small size of the equipment and short interconnections allow to meet the distances specified by the standard. An optional resistor box RS-Box with shunt resistor is available for transient emission measurements as per ISO :2004 and ISO :2011. The RS-Box offers the required 40ohm shunt resistor and other demanding shunt resistors values of e.g. 10ohm, 20ohm and 120ohm. THREE-IN-ONE ARTIFICIAL NETWORK The AN 200N100 is the multi-purpose artificial network designed to cover four different test requirements. The various configurations are selected by two switches. One switch is used to configure the AN 200N100 mains input (no capacitor as per ISO , 1uF capacitor accross the mains input as per CISPR 25 and ISO or 2uF capacitors in series with a 1ohm resistor as per CISPR ). A second switch is used to switch in the internal 50ohm termination resistor as required. The AN 200N100 is fully adapted to the various test requirements and shows the typical impedance characteristics according to the different standards. EM TEST > PAGE 2/5
3 BS 200N100 - ELECTRONIC SWITCH AN 200N100 - ARTIFICIAL NETWORK SPECIFICATION TECHNICAL DATA Max. 60V DC Max. 100A continuous Peak voltage Max. 1,000V Inrush current Max. 400A for 200ms Voltage drop < 1.2V at 100A < 0.2V at 25A as per ISO , CISPR 25, ISO and CISPR , switchable Frequency range 0.1 to 125MHz 1,000V DC/250V AC up to 1kHz Max. 100A AC/DC continuous Inrush current Max. 400A for 200ms Overvoltage protection By varistors Impedance 5uH // 50ohm for details see diagrams on page 2 Overload protection Short-circuit protected Reverse-polarity protected Insertion loss less than 3dB DUT to receiver output Inductance 5uH +/-10% air-core coil Coupling capacitor 0.1uF SWITCH CHARACTERISTICS Switching time 300ns +/- 20% into test load 50uH/0.6ohm On/Off time 10ms to 500ms, continuously selectable via potentiometer Operation mode Indicatied by LED TRIGGER Power supply/dut connection High-current connectors up to 100A 4mm safety lab connectors up to 32A Test output BNC-connection Manual Manual trigger of a single event Auto Automatic trigger with min. 0.1Hz to max. 1Hz repetition, continuously selectable by potentiometer External In CONNECTIONS Dimensions 318 x 126 x 122 mm (L x W x H) Weight approx. 2.8kg Enternal trigger, negative going edge 0V, BNC input 10V MEASUREMENT Voltage monitor BNC output; divider 1:200 +/-5% Trigger Out BNC output; negative going edge 0V Dimensions, weight 90mm x 125mm x 120mm (LxWxH) approx. 1.3kg Supply voltage 24V DC via mains supply adapter EM TEST > PAGE 3/5
4 BSM 200N40 - MECHANICAL SWITCH OPTIONS SPECIFICATIONS OPTIONAL ACCESSORIES DUT supply 12V/24V CA BS 200N Max. 40A DC continuous, resistive load Calibration load 0.6ohm and 50uH for the verification of the electronic switch characteristic RS-BOX Shunt resistor box with Rs = 10ohm, 20ohm, 40ohm and 120ohm Contact high purity silver contacts, no suppression across relay contact, insulated from the coil circuit TRIGGER Manual Manual trigger of a single event Auto Automatic trigger with min. 0.1Hz to max. 1Hz repetition, continuously selectable by potentiometer External External trigger negative going edge 0V, BNC input Operation Indicated by LED MEASUREMENT Voltage monitor BNC output; divider 1:200 +/-5% CRO trigger BNC output, negative going edge 0V Dimensions, weight 90mm x 105mm x 104mm (LxWxH) approx. 0.8kg Supply voltage 24V DC via mains supply adapter EM TEST > PAGE 4/5
5 COMPÉTENCE DANS TOUS LES DOMAINES CONTACTEZ DIRECTEMENT EM TEST Suisse USA / Canada EM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Téléphone +41 (0)61/ > Fax +41 (0)61/ Internet: > [email protected] AMETEK Compliance Test Solutions > 52 Mayfield Ave. > Edison > NJ Téléphone +1 (732) Internet: > [email protected] Allemagne AMETEK CTS Germany GmbH > Lünener Straße 211 > Kamen > Deutschland Téléphone +49 (0)2307/ > Fax +49 (0)2307/17050 Internet: > [email protected] France EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > Mulhouse > France Téléphone +33 (0) > Fax +33 (0) Internet: > [email protected] Chine E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing > P.R. China Téléphone +86 (0) > Fax +86 (0) Internet: > [email protected] République de Corée EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Téléphone +82 (31) > Fax +82 (31) Internet: > [email protected] Pologne EM TEST Polska > ul. Ogrodowa 31/35, Warszawa > Polska Téléphone +48 (0) Internet: /pl > [email protected] Les informations sur l\'étendue de la livraison, la présentation visuelle et les données techniques correspondent à l\'état de développement du produit au moment de la mise en circulation de la fiche technique. Les données techniques sont susceptibles de changement sans préavis. EM TEST > PAGE 5/5
NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES
NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES SELON LES NORMES SUIVANTES... > AIRBUS > BOEING > DO 160 Section 16 > EN 61000-3-11 > EN 61000-3-12 > EN 61000-3-2 > EN 61000-3-3
AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W
AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W SELON LES NORMES SUIVANTES... > Chrysler CS-11809 (2009) > Chrysler CS-11979 > Chrysler DC-11224 Rev.A > DaimlerChrysler DC-10614 > DaimlerChrysler
VDS 200N SERIES VOLTAGE DROP SIMULATOR - BATTERY SUPPLY SIMULATION AND DC VOLTAGE SOURCE
VDS 200N SERIES VOLTAGE DROP SIMULATOR - BATTERY SUPPLY SIMULATION AND DC VOLTAGE SOURCE FOR TESTS ACCORDING TO... > Audi (Reference vehicles) > BMW - (Airbag ECU) > BMW 600 13.0 (Part 1) > BMW 600 13.0
VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE
VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE FOR TESTS ACCORDING TO... > Audi (Reference vehicles) > BMW - (Airbag ECU) > BMW 600 13.0 (Part 1) > BMW 600
UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY
UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY FOR TESTS ACCORDING TO... > ANSI/IEEE C62.41 > ECE-R10 > EN 61000-4-11 > EN 61000-4-29 > EN 61000-4-4 > EN 61000-4-5 > EN 61000-4-8
UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV
UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV FOR TESTS ACCORDING TO... > ANSI/IEEE C62.41 > ECE-R10 > EN 61000-4-11 > EN 61000-4-12 > EN 61000-4-29 >
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
Single Output Switching Power Supply
.. RS- Code: CLP-A Single Output Switching Power Supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY EMC (Note 6) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
DS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
Coupling/Decoupling Networks (CDN)
Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and
40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE
INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE VINCENT ASSOCIATES 803 LINDEN AVE. ROCHESTER, NEW YORK 14625 SERVICE/ORDERS (800) 828-6972 In NY State (585) 385-5930 Fax (585) 385-6004
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Trip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
R448 & R448 V50 A.V.R.
Armature + 6- This manual is to be given to the end user F1 ST5 Field Slow fuse 250V 10 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 22 ST3 requency ST10 50Hz 60Hz
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications
Product Overview Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications The 2Pro AC family of devices provide integrated overcurrent/overvoltage/ overtemperature
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
TORKEL 820 Battery Load Unit
TORKEL 820 Lightweight Expandable system Rugged and reliable for field use Test without disconnecting the battery from the equipment it serves Description During a power outage, crucial telecommunication
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
L78MxxAB L78MxxAC. Precision 500 ma regulators. Features. Description
L78MxxAB L78MxxAC Precision 500 ma regulators Features Output current to 0.5 A Output voltages of 5; 6; 8; 9; 10; 12; 15; 18; 24 V Thermal overload protection Short circuit protection Output transition
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
Digital Clamp-on DMMs with uncompromising performance
Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. Designed to satisfy
Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID
Tension (kv) Impedance (Ohms) EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID frequency (Hz) Simon DESCHANVRES Yannick VERNAY RTE, CNER, Substations Department t (ms) EMTP-RV Users Group
帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP-235864 DSL-20WA 420024 1 Revision: A Date: 2011.10.24 FOR AC-DC LED DRIVER MODEL NO.
CUSTOMER: PART NUMBER: A200 APPROVAL SHEET FOR AC-DC LED DRIVER MODEL NO. DSL-20WA 420024 1 ORDER NO: SP-235864 承 認 書 确 認 后 請 簽 回 一 份 CUSTOMER APPROVED SIGNATURE DEE VAN ENTERPRISE CO., LTD (Head-Quarter)
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
SINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
Description. Table 1. Device summary
2 A positive voltage regulator IC Description Datasheet - production data Features TO-220 Output current up to 2 A Output voltages of 5; 7.5; 9; 10; 12; 15; 18; 24 V Thermal protection Short circuit protection
COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS
IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Proximity Switches RS (Reed Switch)
Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
R&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
ADJUSTABLE VOLTAGE AND CURRENT REGULATOR
L200 ADJUSTABLE VOLTAGE AND CURRENT REGULATOR ADJUSTABLE OUTPUT CURRENT UP TO 2 A (GUARANTEED UP TO Tj = 150 C) ADJUSTABLE OUTPUT VOLTAGE DOWN TO 2.85 V INPUT OVERVOLTAGE PROTECTION (UP TO 60 V, 10 ms)
Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison
Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison Roland Spriessler 1, Markus Fuhrer 2, 1,2 EM Test, Sternenhofstrasse 15, CH-4153 Reinach (BL),
INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: [email protected] INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Power Electronics Testings
Power Electronics Testings Test Solution www.chromaate.com Turnkey Test & Automation Solution Provider www.chromaate.com A Light Emitting Diode (LED), with low power consumption, compact size, long life
1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim
Automotive sensor simulator Operating manual AutoSim Contents Introduction.. page 3 Technical specifications.... page 4 Typical application of AutoSim simulator..... page 4 Device appearance... page 5
Description Part-No. Type PU. Nominal voltage DC12V 768001 Relais-SNR 12V 1W 20 DC 24 V 768002 Relais-SNR 24V 1W 20
Replacement relay, 1COcontact, 6 A, : AgSnO 2,AgSnO 2 +5 µm HV Relay with AgSnO 2 Nominal voltage DC12V 768001 Relais-SNR 12V 1W 20 768002 Relais-SNR 24V 1W 20 DC 60 V 768003 Relais-SNR 60V 1W 20 Relay
Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE
Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing
Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The