Voltage Tolerance Boundary



Similar documents
Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost

Power Quality Standards for Electric Service

Power Quality for Information Technology System

Developing a Utility/Customer Partnership To Improve Power Quality and Performance

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

230 VOLT STANDARDISATION-THE NEXT STEPS

Fundamentals of Power

Power Quality. Uninterruptible Power Supply

Supply Standards: Electricity Supply Standard July JULY 2011 ISSUE 6 UNCLASSIFIED UNCONTROLLED COPY IF PRINTED

AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation

Introduction. Harmonics and IEEE 519 Page 1 of 19

POWER QUALITY IN YOUR HOME

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

SECTION DVD01: VOLTAGE DROP/VOLTAGE FLICKER AND TRANSFORMER SIZING GUIDELINES

Low Voltage Transformer Through-Fault Protection: A System Approach

Technical Comparison of On-line vs. Line-interactive UPS designs

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Short Circuit Current Calculations

Equipment Performance Due to Voltage Sags Test Results for Contactor and Induction Motor

Nuclear Power Plant Electrical Power Supply System Requirements

Guidelines for ATS selection: How to choose the right transfer solution for your power application.

Which UPS is right for the job?

Engineering innovation

T-016: Paralleling Application Manual

Transfer Equipment Controls

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Qualitative Analysis of Power Distribution Configurations for Data Centers

Critical-Power Automatic Transfer Systems Design and Application

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Distribution Operations with High-penetration of Beyond the Meter Intermittent Renewables. Bob Yinger Southern California Edison April 15, 2014

Solar Power Plant Design and Interconnection

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile

Calculation of Voltage Sag Indices for Distribution Networks

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

ENA Customer Guide to Electricity Supply

Data center power dynamics within the settings of regional power grid

ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe

Grounding of AC generators and switching the neutral in emergency and standby power systems

Fusible Disconnect Switch

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

Calculating voltage dips in power systems using probability distributions of dip durations and implementation of the Moving Fault Node method

Advanced Protection of Distribution Networks with Distributed Generators

Power Quality & Custom Power

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Unitil Energy Systems, Inc. Interconnection Standards For Inverters Sized Up To 100 kva

Line Reactors and AC Drives

American National Standard For Electric Power Systems and Equipment Voltage Ratings (60 Hertz)

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

Typical Data Requirements Data Required for Power System Evaluation

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Application of Four-Pole Circuit Breakers within Data Centers

Power Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM. Technical Note No. 7 August 2003

The Seven Types of Power Problems

Voltage Unbalance and Motors

Specifying a Variable Frequency Drive s

Unified requirements for systems with voltages above 1 kv up to 15 kv

1. The type of service available at any particular location should be determined by inquiry at PG&E's local office.

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS

Rotary Phase Converters

C.I.8.2 Offsite Power System. C.I Description

Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller

Power surges can also be generated by equipment in your facility such as:

Evaluating Water-Damaged Electrical Equipment

Arc Terminator Active Arc-Resistant Switchgear

Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering

conventional system operation

SECTION VARIABLE FREQUENCY DRIVES

Intel architecture. Platform Basics. White Paper Todd Langley Systems Engineer/ Architect Intel Corporation. September 2010

Power Supplies 3. SDN-P DIN Rail Series

Diesel Engine Driven Generators Page 1 of 6

SDG&E Electric Distribution System Interconnection Handbook. <Revised as of 10/21/2015>

Ingegneria Elettrotecnica. Development of Human Visual System Analysis Methods for the Implementation of a New Instrument for Flicker Measurements

DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit Ann Arbor Mt. Clemens Port Huron

Motor Protection Voltage Unbalance and Single-Phasing

ELECTRICAL INSPECTION BULLETIN (Effective )

Checking Capacitor Banks for Failed Capacitors

System Grounding and Ground-Fault Protection Methods for UPS-Supplied Power Systems

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

INTRODUCTION TO SYNCHRONIZING AUTOMATIC SYNCHRONIZING CONSIDERATIONS AND APPLICATIONS

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

Cisco Nexus 7000 Series Power Supply Modules

RC NETWORKS SALES GUIDE

A Practical Guide to Dielectric Testing

Joslyn Clark Controls, Inc.

How SafePlug Smart Receptacles Can Save Money in Commercial Buildings

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

Transcription:

Pacific Gas and Electric Company Voltage Tolerance Boundary The only national standard for utilization voltage regulation is ANSI C84.1. Its title is American National Standard for Electric Power Systems and Equipment Voltage Ratings (60 Hertz). The first version in 1954 was a combination of two standards, one from the Edison Electric Institute that represents utilities and the second from NEMA that stands for National Electrical Manufacturers Association. It establishes nominal voltage ratings for utilities to regulate the service delivery and it establishes operating tolerances at the point of use. The design and operation of power systems and the design of equipment to be supplied from such systems should be coordinated with respect to these voltages. In doing so, the equipment will perform satisfactorily in conformance with product standards throughout the range of actual utilization voltages that will be encountered on the system. These limits shall apply to sustained voltage levels and not to momentary voltage excursions that may occur from such causes as switching operations, fault clearing, motor starting currents, and the like. To further this objective, this standard establishes, for each nominal system voltage, two ranges for service voltage and utilization voltage variations, designated as Range A and Range B, the limits of which are illustrated in figure 1 based on a 120 volt nominal system. Voltage (120-V Base) 128 126 124 120 116 114 112 (b) Utilization Voltage Range A 120-600 V Systems Systems of more than 600 V 127 Utilization Voltage Range B 120-600 V Systems Systems of more than 600 V Nominal System Voltage 110 108 (a) 106 104 Figure 1. Voltage Ranges, ANSI C84.1 (a) NOTES: (a) These shaded portions of the ranges do not apply to circuits supplying lighting loads (b) This shaded portion of the range does not apply to 120-600-volt systems. (c) The difference between minimum service and minimum utilization voltages is intended to allow for voltage drop in the customer s wiring system. This difference is greater for service at more than 600 volts to allow for additional voltage drop in transformations between service voltage and utilization equipment. 1

Basically, the Range A service voltage range is plus or minus 5% of nominal. The Range B utilization voltage range is plus 6% to minus 13% of nominal. For range A, the occurrence of service voltages outside of these limits should be infrequent. Utilization equipment shall be designed and rated to give fully satisfactory performance throughout this range (A). Range B includes voltages above and below Range A limits that necessarily result from practical design and operating conditions on supply or user systems, or both. Although such conditions are a part of practical operations, they shall be limited in extent, frequency, and duration. When they occur, on a sustained basis, corrective measures shall be undertaken within a reasonable time to improve voltages to meet Range A requirements. Insofar as practicable, utilization equipment shall be designed to give acceptable performance in the extremes of the range of utilization voltages, although not necessarily as good performance as in Range A. It should be recognized that because of conditions beyond the control of the supplier or user, or both, there will be infrequent and limited periods when sustained voltages outside Range B limits will occur. Utilization equipment may not operate satisfactorily under these conditions, and protective devices may operate to protect the equipment. ANSI C84 does not explain that typically, the nameplate nominal voltage is not the same as the utility nominal voltage. Refer to table 1. ANSI C84 also does not explain that in general, NEMA, National Electrical Manufacturers Association recommends that all electrical appliances and motors should operate at nameplate plus or minus 10% satisfactorily, however not necessarily at an optimum condition. The reason that the nameplate nominal is lower than the service entrance voltage is the acknowledgment that there will be a voltage drop within the electrical distribution system of the end users premise. The National Electrical Code allows up to a 5% drop. There can be a <3% drop in a feeder and an additional <3% drop in individual branch circuits. Table 1. National Steady State Voltage Regulation Standards Nominal Service Utilization Nameplate NEMA Standard -5%, +%5-13%, +6% Motor -10%, +10% 120 114-126 104.4-127.2 115 103.5-126.5 208 197.6-218.4 181-220.5 200 180-220 240 228-252 208.9-254.4 230 207-253 277 263.2-290.9 241-293.6 480 456-504 417.6-508.8 460 414-506 bandwidth bandwidth bandwidth 10% 19% 20% Utilities actively regulate distribution voltages slowly by means of tap changing regulators and by switching capacitors to follow changes in load. These voltage changes are small incremental steps necessary to keep the service delivery voltage within an acceptable range as customers add and subtract load during the day. This slow regulation maintains a sustained voltage range. Sustained usually means a period greater than two minutes. 2

The reason for the CBEMA curve is for changes in voltage shorter than two minutes. As described above, there will be excursions outside the acceptable ranges for short momentary periods. NEW ITIC VALUES 1996 OLD CBEMA CURVE 1977 Duration of Disturbance in Cycles (c) and Seconds (s) Footnote: ITIC = Information Technology Industrial Council CBEMA = Computer and Business Electronic Manufacturers Association ANSI Steady State values are plus 6% to minus 13% measured at end-use equipment Computer and electronic equipment manufacturers usually specify maximum momentary voltage deviations within which their equipment can operate without sustaining errors or equipment damage. This curve shows an envelope of voltage tolerances that is representative of power-conscious computer and other electronic equipment manufacturers. The original CBEMA curve is referenced in ANSI/IEEE Std 446-1987, A Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications. The CBEMA group has changed names to ITIC to represent a broader spectrum of the industry. The wider tolerance curve was created in 1996 to indicate the improved ride through capability of power conscious manufacturers. The original CBEMA curve was established as a guideline 3

for computers in data centers with extensive power quality mitigation measures in place such as motor-generator sets and isolation transformers. For equipment located outside this protected environment, there will be frequent events outside the curve. Some power quality monitors now include the CBEMA/ITIC mask to provide a frame of reference when reviewing recorded events. The assumption is that events within the curve should not cause disruption or damage. Equipment experiencing problems will need some form of mitigation to isolate itself from the electrical distribution system. Before mitigating these disturbances, it is important to understand the equipment s sensitivity level. There are no general equipment susceptibility standards for momentary voltage variations. For a general description of power quality issues and solutions there are three good publications. These are described at the end of this power note. The microelectronics industry has produced two standards in view of the extremely high losses due to power variations in the manufacture of microelectronics; SEMI E10 Standard for Definition and Measurement of Equipment Reliability, Availability, and Maintainability; and SEMI F42 Test Method for Semiconductor Processing Equipment Voltage Sag Immunity. E10 defines the sag ride through capability. F42 defines the test methodology to confirm compliance to the standard. These standards are available from Semiconductor Equipment and Materials International (SEMI), 805 East Middlefield Road, Mountain View, CA 94043. Their web address is www.semi.org. Basically, that industry has decided that if they properly define the problem and provide for a performance test procedure when purchasing new production equipment, they can reduce the number of nuisance tripping problems. An analysis of 30 monitor years of disturbance data collected at major semiconductor manufacturing sites revealed that 15.4% of the events were below the CBEMA 1996 tolerance curve. The average number of occurrences below the CBEMA 1996 curve per site per year was 5.4. The SEMI task force concluded that a higher standard was needed. Duration of Voltage Sag in Seconds 0.05 0.1 0.2 0.5 1.0 100 90 % of Equipment Nominal Voltage 80 70 60 50 40 30 20 10 0 Figure 2. SEMI E10 Voltage Sag Ride-Through Curve 4

Figure two is the approved SEMI E10 Voltage Sag Ride-Through standard. This was determined by statistical data analysis of the frequency and duration of sags and the cost to incorporate ride through mitigation. If you are interested in the development of the SEMI standard, there is a web site where it is spelled out in a document available to the public. The document s name is Guide for the Design of Semiconductor Equipment to Meet Voltage Sag Immunity Standards. The web site address is www.semitech.org. It is classified as a Technology Transfer document #99063760A-TR. Figure three is an overlay of the CBEMA curves and the SEMI E10 curve. The principal improvement in the SEMI curve is lowering the sag ride through curve down to 50% of nominal for the first 200 milliseconds or about 12 cycles. Beyond 12 cycles, the SEMI curve mimics the new CBEMA curve. New/Old CBEMA Curve Compared to SEMI E10 Limits Duration of Voltage SAG in Milliseconds 100 90 3 ms 20 ms 50 ms 100 ms 200 ms 500 ms 1000 ms 10 seconds Steady State 87 80 Original 70 % of Equipment Nominal Voltage 60 50 40 30 20 Original CBEMA Curve New CBEMA SEMI Original CBEMA New CBEMA SEMI One cycle = 16.67 milliseconds @ 60 Hertz 10 0 1/2 cycle 3 cycles 12 cycles 30 cycles 60 cycles Figure 3. Overlay of CBEMA and SEMI curves SEMI E10 sag ride through threshold only defined between 50 milliseconds and one second, (3 cycles--60 cycles). In practice, machine must ride through voltage sag down to 50% of nominal up to 12 cycles. 5

In a parallel development, an IEEE working group generally focusing on sag ride through issues, has produced a standard to analyze the economics of sag ride through mitigation, IEEE Standard 1346-1998, Recommended Practice for Evaluating Electric Power System Compatibility With Electronic Process Equipment. A standard methodology for the technical and financial analysis of voltage sag compatibility between process equipment and electric power systems is recommended. The methodology presented is intended to be used as a planning tool to quantify the voltage sag environment and process sensitivity. It shows how technical and financial alternatives can be evaluated. Unlike the SEMI standard above, this standard does not include performance standards. General power quality references IEEE 1250-1995. Guide for Service to Equipment Sensitive to Momentary Voltage Disturbances. This guide describes momentary voltage disturbances (short duration transients) occurring in AC power distribution and utilization systems, their potential effects on sensitive equipment, and guidance toward mitigation of these effects. IEEE 1100-1999. Recommended Practice for Powering and Grounding Electronic Equipment. Incompatibilities between power system characteristics and equipment tolerances have caused operating problems and loss of productivity in all kinds of power systems - putting facility engineers and system designers in the spotlight to provide effective and efficient solutions. A key element to formulating any solution is the cooperative effort, among power system designers, equipment manufacturers, and the electric utilities, to provide and maintain an acceptable level of load/source compatibility. This is also known as the Emerald Book. IEEE 446-1995. Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications. The Orange Book presents the recommended engineering practices for the selection and application of emergency and standby power systems. It provides commercial/industrial facility designers, operators and owners with guidelines for assuring uninterrupted power. Users in the areas of industrial process operations, medical facilities, and solid-state and computer installations will find the help they need in meeting the demand for uninterrupted power, virtually free of frequency excursions and voltage dips, surges, and transients. To order IEEE standards call 1-800-678-IEEE in US and Canada. For on-line access to IEEE standards information: http://www.standards.ieee.org For on-line access to ITIC curve and definitions: http://www.itic.org/ January 1999 6