Oxford Instruments Austin, Inc.

Similar documents
Electronic Control Devices The European Product Catalogue 2007

INSTALLATION INSTRUCTIONS

INTMOD485-LH Protocol Converter

Absolute Rotary Encoder E6CP

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Applied Electronics. Commercial Dimming System UPDATE NOTICE

OEM-EP Pressure Controllers

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size ( inches [ mm])

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels

USER MANUAL MODEL

FX07 Field Controller

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

The basic set up for your K2 to run PSK31 By Glenn Maclean WA7SPY

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Operating Instructions

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

USER MANUAL V5.0 ST100

WD-AMX Water Detection Controllers

Transmitter Interface Program

Modular I/O System Analog and Digital Interface Modules

Cryogenic Temperature Monitors Model 12 and Model 14 Two or four input channels with Ethernet connectivity

Pace plc. DC60Xu HD HD DTA. Monday, June 25, Private & Confidential

Local supplier shall be ISO 9001 & OHSAS Certified Company.

Industrial Bar Code Scanners

Configuring a Macintosh Laptop to Use Multiple Displays

iloq P10S.10/20 Programming device User's Guide

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Compaq Presario MyMovieSTUDIO. Getting Started

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

K-Type Thermocouple Sensor User s Guide

SMART Board interactive whiteboard system

MyChron Expansion User Manual

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

FX07 Field Controller

LSM-480 USER MANUAL. A.D.J. SUPPLY EUROPE B.V. Junostraat EW Kerkrade The Netherlands

SecureLinx Spider Duo Quick Start Guide

HP ProDisplay P19A LED Backlit Monitor. User Guide

High-Quality Laser Printers With Built-in Duplex Featuring...

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

K9 Heat Alarm Owners Manual HA-1520

HT580 User Reference Guide. Version 1.0

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Connector and Cable Specifications

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Home Theater PC Chassis

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Accessories. Remote Annunciator Module RAM7 RAM7: Remote Annunciator Module. Quick reference. v. 1.0_in

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Digital input modules

Hand-held thermometer Model CTH7000

BOS 73K... BOS 74K...

Cryogenic Vacuum Pumps

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

How To Power A Schen

PCS0100en Persy Control Services B.V. Netherlands

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Welcome to the topic on creating key performance indicators in SAP Business One, release 9.1 version for SAP HANA.

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

4-Channel Thermometer / Datalogger

A project to optimise quality and energy efficiency must include metering

LCD MONITOR / 8 CHANNEL DVR COMBO

Polyphase kwh Electricity Meter

Product Specification instalert Rapid Messenger Variable Message Sign

POINTS POSITION INDICATOR PPI4

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Innovative Electronics for a Changing World INDEX

Repeaters and Mimics Data Sheet

Technical Data Sheet. 3DLevelScanner

Advantium 2 Plus Alarm

PDS-750-TR Touring Power Supply Operator s Manual

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

SoundLAB Software Download Software from the Bogen website:

Series 2000 Audit and Calibration Users Guide

D-MAX WEB GUIDE CONTROLLER WITH OPERATOR INTERFACE PANEL QUICK START SETUP MANUAL

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

User's Guide. Integrating Sound Level Datalogger. Model Introduction

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Product Description Sheet RB15 200D Gantry Robot Item No

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

3500/93 System Display

4 Troubleshooting Your Projector

Speedlink software will run on Windows NT, Windows 7, and Windows 8; it will run on both 32 byte and 64 byte versions of Windows.

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Video to PC Adapter. Model: Operation Manual

Industrial Bar Code Scanners

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

Transcription:

Installation Data Data Sheet Sheet Oxford Instruments Austin, Inc. Issue 01 / January 2013 / Original Instructions

E350 Cryogenic Temperature Monitor Overview Continuous visual update using backlit LCD display Drives a single diode, intended for cryogenic temperature measurement Supports user selection from four pre-defined diode curves Description The E350 Cryogenic Temperature Monitor drives a single diode temperature sensor, and provides a visual display of the temperature on a backlit LCD module. The high resolution measurement sensing circuitry of E350 provides noise rejection to deliver precise, accurate temperature readings. The diode curve is user selectable from four (4) pre-defined curves providing an interface for common diodes. Temperature conversion is provided by a 10µA constant current source using a spline interpolation (piecewise polynomial). E350 Installation 1 1 IEC Power Entry. Universal Power input accepts 110 or 220 VAC at 50 or 260 Hz D-sub 9 Temperature Sensor. Connect temperature sensor according to the following pin out: Pin 1: Shield (GND) Pin 2: No Connect (NC) Pin 3: NC Pin 4: Diode Sensor Positive Pin 5: Diode Sensor Negative Pin 6 Pin 9: NC 2 E350 Back Panel

E350 User Interface The E350 provides a continuous display of the temperature measurement on a backlit 16x2 LCD character display. The top line of the display provides an indication of the temperature status. As temperature increases, the bar graph grows from left to right. 50.7 K Lower temperature indication (50.7 K) illustrated by fewer bars on the visual display. 275.6 K In addition, the front panel LED s color gives the user a visual indication of the temperature range as shown below: Red Temperature > 20 K Yellow Temperature between 15 K and 20 K Green Temperature < 15 K

The user can select the diode curve which corresponds to the type of the temperature diode sensor connected to the E350. To select a diode curve: 1. Press the MENU button. 2. Scroll through the standard diode options by pressing the UP and DOWN buttons. 3. When the appropriate diode curve has been selected, press MENU again. E350 supports the following four types of standard temperature sensor diodes: Austin Scientific (ASC) Temperature Diode CTI Temperature Diode DT-470 Silicon Diode DT-670 Silicon Diode The user selected diode type is stored to permanent memory to ensure the unit powers up in the same state it was powered down.

Technical Specifications The technical specifications for the E350 Temperature Monitor are listed in the table below. E350 Specifications Features Display Temperature Reading of 1 Diode Four Selectable Diode Curves Power 110/220 VAC Input @ 50/60 Hz (Universal Input) Connectors IEC Power Input DB9F (Temperature ( Diode Cable) Dimensions 4.37 37 (W) x 6.20 (L) x 2.56 (H) Order Information The contact information is listed below: Sales & Marketing 1-800-611-8871 Technical Support 1-800-404-1055 or 1-512-441-6893 Web Information http://www.oxford-instruments.com/austin Use the following Table to determine the P/N and optional accessories when placing order with Oxford Instruments Austin, Inc. E35 350 Cryogenic Temperature Monitor 99-00076-010 Configuration Cable Type Single Cryopump or coldhead E350 kit, includes power cable and one 10ft standard single diode cable. For kit with other cable length, see below 15 Ft 20 Ft 50Ft Standard Single Diode Cable 99-00076-015 99-00076-020 99-00076-050 Revision History Date Reason Revision July 2008 Initial Release 1.0.1 January 2013 Update to new corporate format 1.0.2 1.0.3