Agilent E1470A 60-Channel 50 Ω RF Cascade Multiplexer

Similar documents
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Microwave Multiplexer Module

Agilent Test Solutions for Multiport and Balanced Devices

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Agilent 8753ET/8753ES Network Analyzers

Agilent Measuring Noninsertable Devices

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Agilent E5063A ENA Series Network Analyzer

Agilent E5100A Network Analyzer

Agilent 4339B/4349B High Resistance Meters

The Next Generation in Automated Oscilloscope Test

HIGH RELIABILITY POWER SUPPLY TESTING

Agilent U2000 Series USB Power Sensors

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Transponder for GainMaker Amplifiers

Agilent U2000 Series USB Power Sensors

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Agilent 4338B Milliohm Meter

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent 8904A Multifunction Synthesizer dc to 600 khz

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent Technologies 3000 Series Oscilloscopes

Agilent 87421A/87422A Power Supply

Agilent Technologies Storage Area Network (SAN) Test System 1730 Series 1, 2 and 4Gb/s Fibre Channel Traffic Generators and Analyzers

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Improving Chromatic Dispersion and PMD Measurement Accuracy

APPLICATION NOTES POWER DIVIDERS. Things to consider

Agilent 8509C Lightwave Polarization Analyzer

Agilent 8720 Family Microwave Vector Network Analyzers

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Getting Started with the Xilinx Zynq All Programmable SoC Mini-ITX Development Kit

1.44 kw Programmable DC Power Supplies XLN Series

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

iva Cable & Antenna Analyzer

Installation Guide. N5101A Baseband Studio PCI Card. Overview

Agilent P940xA/C Solid State PIN Diode Switches

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Connectors, Adapters, and Tools

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

iva Cable & Antenna Analyzer

Model 201 Wiegand Touchpad Reader Installation Guide

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

High Power Programmable DC Power Supplies PVS Series

Selecting RJ Bandwidth in EZJIT Plus Software

In this section we tell you how to set the fault mode selection plug, key your I/O chassis, install your module and make your wiring connections.

Model CFA-24 Transparent Cable Farm Automation Switch

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

R&S SMZ Frequency Multiplier Specifications

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

Agilent U2000 Series USB Power Sensors

Installation Guide. Zip ATAPI Drive. Quick Start Information Installation Notes Technical Notes Troubleshooting Drive Specifications

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Times Microwave Systems Hermetically Sealed Assemblies

DSA800 Series Spectrum Analyzer

Phase II Design for a Multiband LMR Antenna System

Welch Allyn Vital Signs Monitor 300 Series

Prisma IP 10 GbE VOD Line Card

Mobile Communications DC Sources W

Agilent E6832A W-CDMA Calibration Application

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Multi-Range Programmable DC Power Supplies 9115 Series

R&S ZCxxx Millimeter-Wave Converters Specifications

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

Agilent Balanced Measurement Example: Differential Amplifiers

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Agilent 8590C/E Series Spectrum Analyzers and Accessories Configuration Guide

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Creating Datalogging Applications in Microsoft Excel

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

HP 8590 C/E/L/Q and EM Series Spectrum Analyzers and Accessories Configuration Guide

Compact EGC Amplifier Model 93251

COAXICON Contacts. RF Coax Connectors. Product Facts

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Orbit PCI Mk 2 Network Card. User Manual. Part No Issue 4

ISHIDA BC Scale to Scale Communications

802.11ac Power Measurement and Timing Analysis

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

X8 Option 2 - Technology

Contents i. CNX MIDI Interface Expansion Card: CNXMIDI 0

Physical Specifications (Custom design available.)

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power

JDSU PathTrak. HCU200 Install User s Guide

USB Smart Power Sensor

Transcription:

Agilent E1470A 60-Channel 50 Ω RF Cascade Multiplexer Data Sheet 1-Slot, C-size, register based Twenty 3:1 multiplexer configurations 3:1, 6:1, 9:1 up to 60:1 by cascading twenty multiplexers 500 MHz bandwidth Simultaneous multiple cascade combinations Isolation 50 db at 200 MHz Description The Agilent Technologies E1470A 50 Ω RF Multiplexer is a C-size, 1-slot, register-based VXI module. It is a high density multiplexer featuring twenty 3:1 multiplexers for maximum design flexibility. The twenty 3:1 multiplexers can be arranged in a cascade configuration to form a single 60-channel RF multiplexer, or they can be configured into multiple sets of cascade multiplexers. The E1470A provides a reliable, high quality means of switching your RF system. High isolation is maintained over a wide bandwidth. The twenty independent 3:1 multiplexers can be configured to other multiplexer sizes by specifying a valid path from a COM to a channel in a different bank. Various sizes of multiplexers can be configured from a single E1470A module. Agilent E1470A Refer to the Agilent Technologies Website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable. Programming The E1470A is programmable with SCPI commands or with register reads/writes, making programming and system configuration easy. For example, you can use SCPI commands to specify a source channel, as well as a destination or common connection i.e., PATH 01, 002 (SCPI). Switching is then done automatically.

Configuration The twenty independent 3:1 multiplexers can be configured to other multiplexer sizes by specifying a valid path from a COM to a channel in a different bank. Various sizes of multiplexers can be configured from a single E1470A module. For example, a 6:1 multiplexer can be formed using COM 01 as the common for channels 000 002 and 010 012. A second 6:1 multiplexer can be configured using COM 11 for channels 100 102 and 110 112. Cable and Connectors Each module is shipped with kit Agilent E1470-80003 containing ten cable housing assemblies (P/N 1250-2563) and 80 cable jacks. You must use male jacks (P/N E1470-22101) in the supplied connector housing (P/N 1250-2563). These male jacks allow you to use all the connector sockets available on the E1470A. You can also use individual single jacks from Johnson Components (P/N 131-4304-011/020) or standard SMB male connector jacks. The standard SMB male connector jacks do not allow for adjacent slots to be used due to their outside diameter size. Jacks are for use with double-shielded cables RG316 and RG188. Cable hex crimp size is 0.151. Individual jacks for single-shielded cables are available from Johnson Components, P/N 131-4303-011 for use with single-shielded cables RG174, RG188, and RG316. Johnson Components: U.S.A.Tel.: 1-800-247-8256 Outside U.S.A. Tel.: (507) 835-6222 Fax.: (507) 835-8356 Product Specifications Input Maximum voltage (center or shieldto-center, shield or chassis): 30 V Maximum current (per channel or common): ac rms: 450 ma Maximum power (per channel or common): ac: 10 VA dc Closed channel resistance (typical): ac <1.5 Ω typ. Note: For ac performance, ZL=ZS=ZO, 40 C, RH 95% for C-size, RH 65% for B-size. Characteristic impedance (Zo): 50 Ω Insertion loss: <10 MHz: <0.25 typ. <100 MHz: <0.6 typ. <500 MHz: <3 db (3:1) Crosstalk (channel-to-channel): <10 MHz: < 80 db <100 MHz: < 60 db Crosstalk (channel-to-channel, one channel closed or channel-to-common) (terminated): <200 MHz: < 50 db <500 MHz: < 40 db VSWR: <100 MHz: (3:1) <1.4 <200 MHz: (3:1) <1.45 <500 MHz: (3:1) <1.7 Additional Specifications 3 db bandwidth: 500 MHz: 3:1 200 MHz: 30:1 100 MHz: 60:1 Terminated isolation: 10 MHz: < 80 db 100 MHz: < 60 db 200 MHz: < 50 db (CH000-132 to COM 05 or CH200-322 to COM 25): 500 MHz: < 40 db 3:1 VSWR (CH000-132 to COM 05 or CH200-322 to COM 25): 100 MHz: <1.4 200 MHz: <1.45 500 MHz: <1.7 30:1 VSWR (CH000-132 to COM 05 or CH200-322 to COM 25): 200 MHz: <1.5 60:1 VSWR (CH000-132 to COM 05 or CH200-322 to COM 25): 100 MHz: <1.5 2

General Characteristics Cooling/Slot Relays: Power up/down state: Minimum relay life: No load: Rated load: General Specifications VXI Characteristics Non-latching armature All open 5x10E6 operations 10E5 operations (10 W RF) Watts/slot: 17.50 P mm H 2 O: 0.25 Air Flow liter/s: 1.30 Ordering Information Description 60-Channel RF Cascade Multiplexer Product No. E1470A VXI device type: Register based, A16, slave only Size: C Slots: 1 Connectors: P1/2 Shared memory: None VXI buses: None Instrument Drivers - See the Agilent Technologies Website (http://www.agilent.com/find/inst_drivers) for driver availability and downloading. Command module firmware: Downloadable Command module firmware rev: A.08 I-SCPI Win 3.1: I-SCPI Series 700: C-SCPI LynxOS: No C-SCPI Series 700: Panel Drivers: No VXIplug&play Win Framework: No VXIplug&play Win95/NT Framework: No VXIplug&play HP-UX Framework: No Module Current I PM I DM +5 V: 3.5 0.01 +12 V: 0 0 12 V: 0 0 +24 V: 0 0 24 V: 0 0 5.2 V 0 0 2 V: 0 0 3

4

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: "Our Promise" and "Your Advantage." Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test & measurement needs. Online assistance: www.agilent.com/find/assist Phone or Fax United States: (tel) 1 800 829 4444 Canada: (tel) 1 877 894 4414 (fax) (905) 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 (e-mail) tm_asia@agilent.com Data Subject to Change Agilent Technologies, Inc. 2001 Printed in the U.S.A. May 1, 2004 5965-5610E