COMMERCIAL GAS-FIRED BOILERS

Similar documents
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

SL280UHV SERIES GAS FURNACE WARNING

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Your safety and the safety of others are very important.

CARING FOR YOUR WATER HEATER

G670 Intermittent Pilot Ignition Controls

PACKAGED FIRE TUBE BOILER

Tankless Water Heater

Preventing Overheated Boiler Incidents

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

BERMAD Fire Protection

Boiler Preparation, Start-Up and Shutdown

BERMAD Fire Protection

Operating instructions

The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS

37E73A-903 & 906 INTELLI-VENT

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS


Fossil fuel heating equipment

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Boiler and Burner Cleaning and Servicing Specifications

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WARNING: IMPROPER SERVICING AND START-UP OF THIS EQUIPMENT MAY CREATE A POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING.


INDIRECT WATER HEATER. Installation and Operating Instruction Manual

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Service Manual Models: 502, 752, 1002, 1302,

Model Description / Applications. Intermittent Pilot Gas Ignition Control

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Evaluate, Clean, and Tune Guidance

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Operating instructions

GAS SAFETY PRECAUTIONS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

OTF Oil Fired Pool Heater

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Factory owners must ensure the boiler is:

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

OBSOLETE. VS8420 Millivolt Gas Valve


Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

USER S INFORMATION MANUAL

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Energy Saving Fact Sheet Boilers

Service Manual Models: ER152, ER202, ER252, ER302, and ER402

DC400 Dispensing Cutoff System

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

PREPIPED LIQUID FUEL MANIFOLDS PLPM

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

Manual for Fire Suppression & Methane Detection System

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

PBX Series Quick Fit Connector Bimetallic Steam Traps

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS

Commercial Gas Water Heaters

Installation and maintenance instructions. Danfoss Vent

Air Conditioning Sign-Off Sheet

What you can expect from your Solar Hot Water System

Energy Saver SERVICE MANUAL COMMERCIAL 24 VOLT FLUE DAMPER SERIES WATER HEATER ATMOSPHERIC GAS WATER HEATERS

S8910U Universal Hot Surface Ignition Module

/2010 US/CA

Caution! Observe the safety instructions of this installation and maintenance manual before placing the boiler in operation. Danger!

EXHIBIT A SCOPE OF WORK

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Baxi Combi 80e & 105e

SERVICE MANUAL. Flammable Vapor Ignition Resistant Water Heaters. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

Instruction Manual for Residential Manufactured Home Gas Water Heaters

Instantaneous gas water heater

Product and Safety Information... 2,3 Service and Maintenance Munchkin Operation Primary Water

For installation guide see reverse of book

Float and Thermostatic Traps Series H, C and X

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Fuels Safety Program FS DIRECTOR S PUBLIC SAFETY ORDER

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

2010 Residential Water Heater Replacement Check List

Transcription:

Supplement Manual to 321078-000 Instruction Manual COMMERCIAL GAS-FIRED BOILERS MODELS: UP-FLOW MODELS HW 420/520/670 SERIES 302/303 25589 Highway 1 McBee, SC 29101 WITH ELECTRONIC INTERMITTENT PILOT IGNITION SUPPLEMENT MANUAL to 321078-000 INSTRUCTION MANUAL CSD - 1 MODELS WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. This supplement is to be used when the authority having jurisdiction requires that the installation must conform to the standard for Controls and Safety Devices for Automatically Fired Boilers, ASME CSD-1. The rules of the code cover the requirements for the assembly, operation and maintenance of controls and safety devices on an automatically operated boiler. An installation that conforms with the instruction manual and the specific requirements set forth in this supplement is said to be in compliance with ASME CSD-1. The gas control string that meets the requirements of CSD-1 is shown in Figure 1 of this supplement. The boiler is fitted with a single stage (high fire) control. This control is the same found on standard HW units with the addition of extra valving that allows for periodic leak testing. A two trial ignition module, United Technologies 1003-617A (AOS P/N 320941-000) along with United Technologies 1145-2 CSD-1 Control Lockout Module (AOS P/N 320942-000) are installed in place of Honeywell S86XX Module used on HW standard models. The two trial module's alarm output will be energized if the pilot burner does not ignite within 15 seconds of two trials, which will trigger the UT 1145-2 Control Lockout to shut down the power to the ignition module and to illuminate the red LED. If the lockout does occur, the red reset button on the control lockout module must be pressed before the ignition is again operative. Thank you for buying this energy efficient boiler. We appreciate your confidence in our products. PLACE THESE INSTRUCTIONS ADJACENT TO BOILER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE PRINTED IN THE U.S.A. 0911 321488-000

TABLE OF CONTENTS TABLE OF CONTENTS... 2 GAS CONTROL DIAGRAM... 3 WIRING DIAGRAM... 4 OPERATING SEQUENCE... 5 OPERATING SEQUENCE WHEN WIRED AS SHOWN... 5 TESTING AND MAINTENANCE... 6 INSTRUCTIONS FOR TESTING AND MAINTENANCE... 7 DAILY CHECKS... 7 WEEKLY CHECKS... 7 MONTHLY CHECKS... 7 SEMI-ANNUAL CHECKS... 7 ANNUAL CHECKS... 7 2

GAS CONTROL DIAGRAM Figure 1. CSD-1 GAS CONTROL DIAGRAM CSD-1 required components are factory installed and are shown in Figure 2. The Safety High Limit Manual Reset, White-Rodgers 11B55-104 (P.N. 98054-1) is factory set for installation as a Hydronic Heating Boiler, with maximum stop setting of 250 F. For installation as a Hot Water Supply Boiler, the stop must be reset to a maximum of 210 F. For additional information on this Hot Water Boiler installation, see Instruction Manual 321078-000. The wiring changes brought about by the addition of the Figure 2 manual reset High Limit, and the Flow Switch are reflected on the wiring diagrams shown in Figure 3. Boilers are shipped with a 50 lb. Relief Valve installed for installation as a Hot-Water Heating Boiler. For installation as a Hot-Water Supply Boiler the Relief Valve must be replaced. See Instruction Manual 321078-000 for further information on relief valve for Hot-Water Supply systems. Figure 2. CSD-1 OUTLET MANIFOLD 3

WIRING DIAGRAM Figure 3. WIRING DIAGRAM 4

All units are built with an ignition control module that provides the ignition sequence, pilot flame monitoring, and safety shut off of the gas valves. The CSD-1 ignition control modules are of two 15 seconds pilot trials with 5 minutes waiting period between the two trials. If the pilot flame is not established/confirmed during the first 15 seconds ignition trial, or if the pilot flame signal is lost after main burner is ON, the United Technologies (UT) ignition module will de-energize the gas valve and wait for 5 minutes. It will start one more 15 seconds trial for ignition. If the pilot flame is still not established, the alarm contacts on the ignition module will be energized, which will cause the CSD-1 lockout module to shut down the power to the ignition module and illuminate the red LED. The ignition module will be in "Lockout" mode until the reset button on the lockout module is pressed. OPERATING SEQUENCE WHEN WIRED AS SHOWN 1. With power supplied the unit becomes activated. 2. When the System Controller (i.e., tank temperature control, thermostat, building controller, etc.) closes "calling for heat", power will activate the circulating pump. Power is also supplied to the normally open contacts of the flow switch. 3. With the pump providing sufficient water flow, the flow switch will close contacts; allowing power to be supplied to the transformer through the manual reset high limit. 4. Power continues through the normally closed auto reset high limits to energize the ignition control module. Opening the contacts on either high limit immediately shuts down the control module. 5. Once energized, the control module tries for ignition by starting a control timer, opening the pilot gas valve (PV) and generating a high voltage pulse. Gas and ignition sparks are supplied at the pilot until the pilot lights or the control timer terminates the ignition trial. If the pilot does not light, or the module does not recognize a stable flame, the module will de-energize the gas valve for 5 minutes, then starts the second and last 15 second trial for ignition. 6. When the pilot flame has been established and accepted by the control module sensing circuit, power is allowed to energize the main gas valve (MV). This valve opens, allowing gas to flow to the main burner which is then ignited by the pilot flame. Failure of the pilot flame at any time during operation will cause the control module to shut down the gas valve. 7. The system continues to operate until "call for heat" is satisfied. The unit then shuts down. The thermal balancer keeps the pump operating approximately one (1) extra minute for heat exchanger post-purge. The unit will continue to operate automatically as required. OPERATING SEQUENCE 5

TESTING AND MAINTENANCE Where required by the local authorities having jurisdiction, a fuel cleaning device such as a filter or strainer should be installed in the main gas supply line to the unit (see Figure 1 on Page 3). A gas service pressure regulator is required to maintain the gas supply pressure below the maximum allowable pressure indicated on the appliance rating plate. A gas pressure relief valve, if required by the local code authority, should be installed upstream of all operating and safety controls in the gas train and downstream of the gas pressure regulator in the gas supply line (see Figure 1 on Page 3). Pertinent operating, cleaning and testing procedures are outlined in this supplement in the TESTING AND MAINTENANCE section. A Manufacturer s/installing Contractor s Report for ASME CSD - 1 Certification and Reporting (CG-500) requirements is provided with the instructions. This report shall be made available to the authorized inspection agency or the inspector for action as required by the local jurisdiction. Installing contractors shall maintain a data report for each installation completed. It is the responsibility of the installing contractor to deliver the pertinent operating, cleaning and testing procedures together with the complete wiring and piping diagrams, to the owner/user and to obtain a receipt for the instructions. The receipt shall be filed with the installation report. TESTING AND MAINTENANCE Periodic testing of all boiler controls and safety devices is required to verify correct operation. Precautions shall be taken to protect against bodily injury or property damage while tests are being conducted. Cover plates that require removal in order to gain access to items requiring maintenance or testing shall be replaced before the boiler is put back in service. Since it is essential to have all control and safety devices operating as intended at all times, a periodic testing and maintenance schedule should be set up and followed with results being logged on a regular basis. Operators or maintenance technicians should follow the recommended procedures set forth in the instructions and allow for any additional circumstances that arise based on the particular installation when preparing a maintenance program. The operator or technician should thoroughly understand the operating procedures and be able to recognize an equipment malfunction. Obtain a receipt for the instructions. The receipt shall be filed with the installation report. Table 1, provided herein is a recommended guideline to follow for periodic testing of the boiler's safety devices and controls. Detailed maintenance procedures are included here as well. Table 1. PERIODIC TESTING PROCEDURES ITEMS FREQUENCY ACCOMPLISHED BY REMARKS 1. Gauges and Indicators Daily Operator Visually inspect, log observations. 2. Burner Flame Daily Operator Visually inspect for uniform blue flames. 3. Pilot Burner Daily Operator Visually inspect for uniform flame envelope. 4. Flame Failure Detection Weekly Operator Close Pilot Manual Shutoff Valve, check safety shutdown time, log results. 5. Gas Valves Weekly Operator Open Operating Control, listen for valve closure, check for voltage. 6. Flow Switch Weekly Operator See detailed instructions. 7. Vent System Monthly Operator See detailed instructions. 8. Optional Power Vent Monthly Operator See detailed instructions. 9. Burner Components Monthly Service Technician See Owner s Manual 10. Heat Exchanger Assembly Semi-Annually Service Technician See detailed instructions. 11. Transformer Semi-Annually Service Technician Check primary and secondary voltage, log results. 12. Manual Reset High Limit and Annually Service Technician See detailed instructions. Auto Reset High Limit 13. Safety Valves As Required Operator See detailed instructions. 14. Drip Leg and Gas Strainer As Required Operator See detailed instructions. 6

DAILY CHECKS INSTRUCTIONS FOR TESTING AND MAINTENANCE 1. Thermometers and temperature gauges should be visibly inspected on a daily basis for normal operation. These items should be noted and the differential temperatures recorded during operation. If the temperature differential increases by five (5) degrees Fahrenheit (3 degrees C) over the original installation, a general deliming of the heat exchanger may be required. 2. Visually inspect main burner flame by viewing upwards between the burners from the front bottom of the boiler. Inspect for well-defined blue flames. Check for smooth lightoff. 3. Visually inspect pilot burner for a well-defined flame pattern. Pilot flame should envelop 3/8 to 1/2 inch (9 to 12 mm) of the top of the insulated rod on the pilot burner. WEEKLY CHECKS 4. When satisfied, or on lockout, the main gas valves should shut off within five(5) seconds. With the system operating, momentarily turn the system controller down to shut down the boiler. Listen for valve closure, noting timing. Verify that there is no voltage present at the valves. Return the system controller to its normal setting. 5. When a pilot flame failure is detected the boiler should shut off within four (4) seconds. With the boiler operating, close the manual pilot shut-off valve, which is located in the pilot gas supply line. Note gas valve closure time. Verify that there is no voltage present at the valves. 6. Flow switch operation is checked by verifying the switch position during operation. With the cover removed, and water flowing through the system, observe that the switch closes the circuit between terminal #1 (common) and terminal #2 (flow closes circuit). When flow stops, this switch will open the circuit, shutting down the boiler. Note your observations. MONTHLY CHECKS 7. The flue collector and draft hood are to be visually inspected internally for any signs of deterioration. Significant corrosion can signal high moisture content or chemical reactions in the flue gases. The use of a mirror and light source allows for easy inspection through the draft hood opening. 8. On optional power vent system, the blower prover switch may be checked by disconnecting the pressure switch tube. The boiler will shut down if already operating, or not start if it is not. Reconnecting the tube will allow the boiler to fire. Note your observations. SEMI-ANNUAL CHECKS 9. Burners shall be maintained per the operating instructions of the Instruction Manual. 10. The heat exchanger is to be visually inspected for build up of deposits or tube distortion. This is best accomplished when the burners are removed for their inspection. Light deposits are to be brushed clear. Heavy deposits or tube repairs may require removal of the heat exchanger. As well, heavy deposits may indicate the need for more frequent inspections and changes in operating parameters. Refer to the Instruction Manual regarding air supply and corrosion. 11. The transformer's primary and secondary voltages can be checked with a voltmeter and the voltages recorded. ANNUAL CHECKS 12. The Manual Reset High Limit may be checked by recording the temperature settings, changing the auto reset limit (auto reset limit may require temporarily jumping the 2 terminals to bypass the control for higher temperature) and system controller to a higher set point than the limit itself and running the boiler. Allow the boiler to shut down on Manual High Limit. After shut down, the boiler should not fire up until the manual reset button is depressed and power to the unit is reset. The auto reset limit and the system controller may be tested in similar fashion but a shut down on either will not require the power to the boiler to be reset. Note: If jumper wire was used be sure to remove it. Return all temperature settings to the original positions upon completion of test. 13. Redundant Safety Gas Valves may be checked for proper closure upon shutdown and should stop the flow of gas to the burner within five (5) seconds of being de-energized. Downstream of each valve is a smaller leak test valve. Removal of the plug will allow the connection of a gas pressure gauge for the purpose of testing - see Figure 1 on Page 3. The Redundant Safety Gas Valve first valve seat may be checked with the boiler off. Close the manual valve located ahead of the redundant valve. Open the first leak test valve, note the gauge pressure and verify it is stable. Open the manual valve allowing gas to flow against the first valve seal. A steady increase in gas pressure indicates gas is leaking past the valve seat and the redundant valve should be replaced. To check the second redundant valve seat, first disconnect the electrical supply wire (brown) from TH terminal on redundant valve. With the firing valve closed, open the leak test valve downstream of the redundant safety valve, note the gauge pressure and verify it is stable. Operate the boiler to call for heat allowing the pilot burner to light. The first valve seat will open allowing gas against the second valve seat. A steady increase in gas pressure indicates fuel is leaking past the second valve seat and the redundant valve should be replaced. 14. The sediment trap (dirt leg) and gas strainer (if required) should be inspected periodically for accumulation of foreign debris that could cause blockage. Gas should be shut off ahead of the particular device to be cleaned or inspected to prevent gas leakage. 7