DXC Family. Multiservice Access Node FEATURES



Similar documents
DXC-8R/10A/30 Multiservice Access Nodes

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

WEB RANger-II Internet Access Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-E1E Managed E1 and Fractional E1 Access Device

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

IPmux-1E TDM Pseudowire Access Gateway

TDMoEthernet. Description

1. Overview. 2. F-bit Utilization

Loop-IP6700 TDMoEthernet

Optimux-134, Optimux-125

Loop-IP6700 TDMoEthernet

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

Optimux-134, Optimux-125

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

Loop-V4300 MINI DACS E1/ T1 CONVERTER

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Optimux-34, Optimux-25

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

VALIANT COMMUNICATIONS LIMITED

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

ORION TELECOM NETWORKS INC. T1

F2400 FOM II Series Fiber Optic Modem Technical Manual

Octal T1-10/100 RIOP Installation Guide

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

Appendix D T1 Overview

SOLUTIONS FOR AN EVOLVING WORLD IMUX 2000 T1/E1 MDACS. Cross-Connect Switch IMUX 2000 T1/E1 1

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Product Overview. Features CHAPTER

24-Port Channelized E1/T1 Line Card Overview

Chapter 4 T1 Interface Card

Cisco Channelized T1/E1 and ISDN PRI Modules

Intraplex T1 CrossConnect System & Server Installation and Operation Manual Issue 1.1, December 2001

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

T1 Networking Made Easy

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Starlink 9003T1 T1/E1 Dig i tal Trans mis sion Sys tem

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Configuring E1 and T1 Interfaces

Loop-IP6702 TDMoEthernet

Configuring E1 and T1 Interfaces

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

DigiPoints Volume 1. Student Workbook. Module 4 Bandwidth Management

Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I

Updated March 2013 UCC Ensuring the Reliability of the Electric Power Grid. T1/E1 Multiplexer with Common Logic Redundancy

cpci cfxo3120 FXO/FXS VoIP Gateway

Loop Telecom. Total Access Solutions for Enterprise Network, Cellular & Gateway Operator.

DataSMART 681, 696 and 698

SRX 210 Services Gateway T1/E1 Mini-Physical Interface Module

! encor en etworks TM

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Setting Up and Testing the MAX Hardware

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet

Cisco Communication Media Module

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Cisco Third-Generation 1-, 2-, and 4-Port T1/E1 Multiflex Trunk Voice/WAN Interface Cards

Multiband MAX. Multimedia Access Videoconferencing Backup/Overflow. Networking Solutions for High Bandwidth Network Requirements

T3 Mux M13 Multiplexer

LA-110. Advanced Integrated Access Device FEATURES

Cisco 2-Port and 4-Port Channelized T3 (DS-0) Shared Port Adapters

TAM Port T1 Access Multiplexer

G.703 Fractional T1 Access Unit. User Guide

OPERATION MANUAL INSTALLATION AND DXC-4. E1/T1 Grooming Device. Version 1.0. Innovative Access Solutions

WANs connect remote sites. Connection requirements vary depending on user requirements, cost, and availability.

VALIANT COMMUNICATIONS LIMITED

- T-Carrier Technologies -

Optical Product Families

Cisco 2- and 4-Port Clear Channel T3/E3 Shared Port Adapters Version 2

Overview of Cisco 2600 Series Routers

The Conversion Technology Experts. Media Conversion: Cost-Effectively Integrating T1 into your Fiber Network

Fundamentals of Telecommunications

Adtech Data Link Simulators.

FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

These highly flexible interface cards facilitate several important applications:

Liberator S. Technical Specification

BridgeWay Fixed Base Radio Telecom VoIP Gateway

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

Figure 1 - T1/E1 Internet Access

Cisco Packet-over-T3/E3 Service Module

Loop-IP6510 Multiple WAN Router/Bridge

Cisco One and Two Port T1/E1 Multiflex Voice/WAN Interface Cards

Transcription:

DXC Family Multiservice Access Node FEATURES Digital cross-connection for up to 30 n x 56/64 kbps or T1/E1 over copper or fiber The modular DXC family includes the following chassis types: DXC-30 with 15 I/O modules DXC-10A with 5 I/O modules DXC-8R with 4 I/O modules Programmable DS0 nonblocking cross-connection Optional redundancy for common logic and power supply T1/E1 conversion supports A-law/µ-law and signaling conversion Supports transmission of T1 traffic over E1. Complies with ITU-T G.802 Broadcast support Inverse multiplexing module supports up to 8 T1/E1 trunks Controlled slip for buffer overflow/underflow Management: Out-of-band via V.24 supervisory port or Ethernet management port In-band via TS 0 or dedicated timeslot RADview SNMP management system on PC or UNIX (HPOV) platform Telnet support Separate dial-in/dial-out port Supports SNMP agent and standard management protocols: SLIP, PPP and RIP2 Local Loop Access solution with built-in fiber optic link, LTU or CSU TFTP support for Common Logic software upgrade

DESCRIPTION The DXC family of modular Multiservice Access Nodes provides non-blocking DS0 cross connect for up to 30 T1/E1 lines and supports built-in Local Loop solutions. Plug-in interface modules supporting n x 56/64 kbps, T1 or E1 transmission over fiber or copper, are available. Each interface module is equipped with two ports. Also available is the DIM module which provides inverse multiplexing capabilities for n x 56/64 kbps, T1 or E1. Typical applications for the DXCs: Providing Local Loop access solution together with traffic grooming, re-directing voice and data to different trunks (see Figure 1). Concentrating multiple T1/E1 lines from a cellular base station onto a full E1 link to the mobile switch center (see Figure 2). Providing conversion/gateway between T1 and E1 networks for both data and voice (see Figure 3). APPLICATIONS In order to support the needs of different applications, the DXC family features three unit variants: DXC-30 (3U high) chassis with 15 I/O module slots DXC-10A (1U high) chassis with 1 built-in I/O module and 4 I/O module slots DXC-8R (1U high) chassis with 4 I/O module slots All versions are stand-alone units which can also be mounted in 19" racks. CROSS CONNECT The DXC-30 supports up to thirty T1, E1 or n x 56/64 kbps ports. The smaller DXC-10 supports up to ten ports, while the DXC-8R supports up to eight. A user-programmable connection table connects any incoming 64 kbps timeslot to any outgoing 64 kbps timeslot. Support is provided for drop & insert and broadcast. Channel relocating and half duplex conferencing are also supported. Cross-connection of n x 56 kbps or n x 64 kbps channels is implemented by placing the data onto a T1 or E1 frame, using only the required number of timeslots. This provides Fractional CSU/DSU functionality. T1/E1 CONVERTER DXC can function as a converter between T1 ports and E1 ports. DXC-30 converts between up to sixteen T1 and thirteen E1 ports, DXC-10A converts between up to five T1 and four E1 ports, DXC-8R converts between up to four T1 and three E1 ports. A-law/µ-law and signaling conversion is performed according to the T1 and E1 standards. BASIC UNITS The basic DXC-30 unit includes one power supply, one common logic module and fifteen I/O slots for the plug-in interface modules. Optional redundancy for the common logic and power supply is available. The basic DXC-10A unit includes one power supply, one common logic module, one built-in interface module and four I/O slots for the additional plug-in interface modules. The basic DXC-8R unit includes two -48 VDC power supplies and two common logic modules for system redundancy. DXC-8R has four I/O slots for the plug-in interface modules. (See separate data sheet for details.) Various timing options cover all timing possibilities for the T1/E1 interface. These include internal clock, station clock, and loopback timing sourcing from any selected T1/E1 port or n x 56/64 kbps port. Figure 1. Multiservice Access Platform

COMMON LOGIC The DCL.1 common logic module stores both matrix configuration and event information. It communicates with the management station using an SLIP/PPP protocol (by means of an SNMP agent). Telnet and ASCII terminal management are also supported. The DCL.2 common logic module stores matrix configuration and event information, as well as configuration for alarm mask. It communicates with the management station using a SLIP/PPP/Ethernet connection (by means of an SNMP agent). DCL.2 can pass management information received from 30 remote sites over a single dedicated timeslot or TS 0, to the central management site. FLASH EPROM for software download, Telnet and ASCII terminal management are also supported. I/O MODULES The DT1, two-port T1 interface module, complies with AT&T TR-62411 and ANSI T1.403 requirements, and supports both D4 or ESF framing formats and AMI line code (zero suppression is selectable for either Transparent, B7ZS or B8ZS). For long range applications, a CSU option is available. DT1B version, with BERT and loopback per timeslot, is also available The DE1, two-port E1 interface module, complies with ITU-T Rec. G.703, G.704, G.732, G.736 and G.823, and supports both 2 and 16 frames per multiframe (256 N and 256 S respectively), TS 0 multiframe with CRC-4 and HDB3 line code. For long range applications, an LTU option is available. DE1B version, with BERT and loopback per timeslot, is also available. The DHS, two-port n x 56/64 kbps data module, provides two high speed synchronous data channels. Each channel is independently selected for either V.35 or RS-422/V.11 interface. Each channel can support bit rates of n x 56 kbps or n x 64 kbps, where: n = 1 to 24 for T1, n = 1 to 31 for E1. The DFO, two-port Fiber Optic Link module, enables the DXC to connect directly to a fiber optic network, eliminating the need for an external fiber optic modem or repeater. DFO operates with different grades and sizes of single/multimode fiber optic cable and is available with LED and laser diode optical interfaces. The DIM, Digital Inverse Multiplexer module, working in conjunction with dual-port DE1 or DT1 interface modules, enables the DXC to function as an inverse multiplexer. DIM allows transmission of high speed signals over up to eight T1/E1 lines. This is achieved by breaking down the high speed signals over the multiple T1/E1 lines, and routing these signals over different paths or facilities, while ensuring transmission integrity. MANAGEMENT Setup, control and diagnostics can be performed out-of-band via a V.24 supervisory port or optional Ethernet management port (with DCL.2 only) using an ASCII terminal with SLIP or PPP protocols. A built-in SNMP agent enables management by a RADview-HPOV or RADview-PC management system for configuration and diagnostics of remote devices using TS 0, a dedicated timeslot of T1/E1 trunk, or Telnet. Diagnostic loopback support for each T1/E1, n x 56/64 kbps module or per individual timeslot. Support includes internal BERT, loopback toward the local or remote DTE, PLB, LLB code injection per ANSI T1.403. Enhanced statistics include T1 ESF diagnostics according to ANSI T1.403 and AT&T 54016 (Local Support); E1 CRC-4 diagnostics per ITU-T Rec. G.706 are performed in a manner similar to AT&T Pub. 54016. A separate dial-in/dial-out port supports remote configuration (dial-in) and automatic alarm indication (dial-out). For dial-out operation, an external modem is activated to automatically dial a pre-programmed number whenever an alarm event occurs. The DXC can be managed by a UNIX-based or PC-based SNMP management system. The software is user friendly, GUI based and runs under PC/Windows (RADview-PC/ WAN) or HP-Openview UNIX (RADview-HPOV/WAN) systems. In addition, configuration and monitoring is provided via Telnet or a dumb terminal. Network management provides centralized control of all network nodes, including interfaces configuration, connection setup, alarm and management. Up to 30 remote locations can be managed by the DXC using TS 0 or a dedicated timeslot. Alarm status and system configurations are available at all times. Multiple DXC chassis can be controlled from a single PC or UNIX workstation. Programming and set-up of a remote DXC is accomplished either: Via TS 0 Through the supervisory port of the remote unit, over a modem link or over a FRAD Over a full in-band dedicated timeslot, supporting SLIP, PPP and RIP2 standard protocols.

SPECIFICATIONS T1 Interface (DT1 Module) Number of ports: two per module Compliance: AT&T TR-62411, ANSI T1.403, ITU-T Rec. G.703, G.704 Framing: D4, ESF Data rate: 1.544 Mbps Line code: AMI Zero suppression: Transparent, B7ZS, B8ZS Impedance: 100Ω, balanced Signal levels: Receive: 0 to -40 db with CSU 0 to -10 db without CSU Transmit: 0 db, -7.5 db, -15, -20 db with CSU ±3V (±10%), soft-adjustable to be measured at 0 to 655 feet without CSU Jitter performance: As per AT&T TR-62411 Connector (per port): RJ-45 E1 Interface (DE1 Module) Number of ports: two per module Compliance: ITU-T Rec. G.703, G.704, G.732, G.736 Framing: 256N: (no MF, CCS) 256N: (no MF, CCS) with CRC-4 256S: (TS16 MF, CAS) 256S: (TS16 MF, CAS) with CRC-4 Data rate: 2.048 Mbps Line code: HDB3 Impedance: 120Ω, balanced 75Ω, unbalanced Signal level: Receive: 0 to -40 db with LTU 0 to -10 db without LTU Transmit: ±3V (±10%), balanced ±2.37V (±10%), unbalanced Jitter performance: As per ITU-T Rec G.823 Connectors (per port): RJ-45, balanced; two BNC coaxial, unbalanced Station Clock Interface Data rate: 1.544/2.048 Mbps (selectable) Compliance: ITU-T Rec. G.703 Connectors: RJ-45, balanced; two BNC coaxial, unbalanced GENERAL Timeslots Mapping Any timeslot to any timeslot with/without A-law/µ-law and/or signaling conversion per timeslot Timing System clock source: Internal clock (±30 ppm) Station clock Receive clock (from any port) Elastic Buffer Buffer length: ±1 T1/E1 frame Underflow: 1 frame repeated Overflow: 1 frame skipped (No frame sync loss for buffer overflow or underflow) Data delay: up to 375 µsec Signaling buffer: ±1 T1/E1 multiframe Figure 2. Bandwidth Optimization in a GSM Network using DXC-8R Figure 3. T1/E1 Conversion and Access to Carrier Backbone

Unused Timeslot Code Any user defined code Diagnostics Local T1 or E1 loopback Remote T1 or E1 loopback Code activated network loopback per ANSI T1.403 Local and remote n x 56/64 kbps data port loopback Loopback for any timeslot Built-in BERT Alarm mask Statistics T1 ESF diagnostics: full support according to ANSI T1.403 and local support according to AT&T 54016 transparent FDL between two T1 ports E1 CRC-4 diagnostics: per ITU-T Rec. G.706; local support equivalent to AT&T 54016 Alarm Response (Bi-directional) Received impairment on link n (loss of signal/frame): Yellow alarm Transmit response on link n (loss of signal/frame): Yellow alarm Transmit response on link m (on connected TS): DS-0 OOS pattern OOS A, B signaling Supervisory Port (SP) Interface: V.24/RS-232, async Data rate: 0.3 to 9.6 kbps, autobaud Connector: 9-pin D-type female Management Port - Dial Port (SP-MODEM) with V.24/RS-232, async interface; Data rate: 0.3-9.6 kbps, autobaud Connector: 9-pin D-type female,dte - Ethernet with UTP (DCL.2 only) - Ethernet with BNC (DCL.2 only) Indicators Front panel: Alarm, Test On-line (per power supply) On-line (per common logic) Rear panel: Local sync loss (per link) Remote sync loss (per link) Power Supply 115/230 VAC (±10%), 47 to 63 Hz (DXC-30, DXC-10A only) -48 VDC (±10%), 100W 1997 RAD Data Communications Ltd. Physical DXC-30 Height: 13.2 cm / 5.25 in (3U) Width: 44.0 cm / 17.3 in Depth: 25.4 cm / 10 in Weight: Less than 8 kg for fully equipped hub DXC-10A and DXC-8R Height: 4.4 cm / 1.75 in (1U) Width: 44.0 cm / 17.3 in Depth: 25.4 cm / 10 in Weight: Less than 2.5 kg Environment Temperature: 0-45 C / 32-113 F (0-40 C for DXC-30) Humidity: up to 90%, non-condensing ORDERING Basic units and I/O modules, as well as any additional System modules, are ordered separately. BASIC UNITS DXC-30/#/+ Basic unit includes chassis, one power supply and one DCL.1 common logic module (no I/O modules) DXC-30-1/?/#/+ Basic unit includes chassis, one power supply and one DCL.2 common logic module (no I/O modules) DXC-10A/@/*/$ Basic unit includes chassis, power supply, DCL.1 common logic module and one built-in I/O module DXC-10A-1/?/@/*/$ Basic unit includes chassis, power supply, DCL.2 common logic module and one built-in I/O module DXC-8R Basic unit includes chassis, two power supplies (-48 VDC), two DCL.1 common logic modules (no I/O modules) DXC-8R-1/? Basic unit includes chassis, two power supplies (-48 VDC), two DCL.2 common logic modules (no I/O modules) I/O MODULES DXC-M/T1/$ DT1 Two-port T1 Interface Module DXC-M/T1B/$ DT1 Two-port T1 Interface Module with BERT and loopback per timeslot DXC-M/E1/$ DE1 Two-port E1 Interface Module DXC-M/E1B/$ DE1 Two-port E1 Interface Module with BERT and loopback per timeslot SYSTEM MODULES DXC-30M-CL.1 DCL.1 Common Logic No.1 Module DXC-30M-CL.2/? DCL.2 Common Logic No.2 Module with enhanced management, FLASH EPROM for upgrade DXC-M-PS/AC 115 to 230 VAC power supply (for DXC-30 only) DXC-M-PS/DC -48 VDC power supply (for DXC-30 only) ORDERING OPTIONS? Specify management port interface: (default is for V.24/RS-232 dial port) U for Ethernet 10BaseT (UTP) B for Ethernet 10Base2 (BNC) # Specify R for power supply and common logic redundancy + Specify DXC-30 power supply: AC for 115 to 230 VAC operation 48 for -48 VDC operation @ Specify built-in I/O module T1 for DT1 module E1 for DE1 module * Specify DXC-10A power supply: 115 for 115 VAC operation 230 for 230 VAC operation 48 for -48 VDC operation $ Specify C for built-in CSU (T1) or LTU (E1) (default is without CSU or LTU) Specifications are subject to change without prior notice. 772-100-12/97