Saferand easierinstallation



Similar documents
Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

INSTALLATION INSTRUCTIONS

BIS WC Element / Lyft Alpro

How To Replace A Reverse Osmosis Water Tank

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Sliding and Folding Door Fittings Sliding Door Accessories

HORIZONTAL INSTALLATION

12.1 Schlüter -KERDI-BOARD

Installation Instructions For Slider Casement Air Conditioners

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

FLUSHING CISTERNS. product catalogue

CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls

INSTALLATION OF A BAY WINDOW

PITCHED ROOF STRUCTURES

Guide rail bracket (for adjustable heads)

Premier & Deluxe 3-Season Room Sliding Glass Door

Packaged Terminal Air Conditioner Wall Sleeve Installation

INSTRUCTIONS: LocknCharge Laptop Carts

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

IMPORTANT INFORMATION

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.

CRASH RAIL INSTALLATION HEIGHT

Samuel Shorty Bunk Bed

Porcelain Vessel Sink Installation

PUBLIC RESTROOMS, DESIGN INTENT

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Flue Installation. High Efficiency Condensing Boilers

plumbing products guide

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Coolflo Safe Touch Shower Mixing Valve ST20015CP

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

Seismic Installation for Attic Storage System

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09042K1


FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Speed-Mat Rectangle Cutter

How to build a Pizza Oven in 4 days

Important Information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

Guidelines for Earthquake Bracing of Residential Water Heaters

Base Cabinet with Self-storing Folding Doors and Floor

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

PLUMBING CARE AND REPAIR

Morgue refrigeration unit

AMS 120. EFT Guest Card Terminal & Refund unit

Select Radiators Installation Guide

Can you design a frameless shower enclosure that doesn't leak?

Cedar Cottage Doghouse Plans

K17.11 DOOR BOLTS K17 DOORS

6mm Two Door Offset Quadrant

39HQ Airovision Air Handling Units

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl.

Installation Guide. Bath and Wall Surrounds SERIES B

Page 2 of 6. Fittings Checklist. Care & Maintenance. Additional Tools Required. General Hints & Tips When

Installation Instructions

BEDFORD DORMOBILE PARTS LIST JUNE 2016

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Beautifully Traditional

Cooktop Low-Profile Ventilation Hoods

STABITHERM INSTALLATION & SERVICE BOOKLET

EZ-48-3AB Weather Station Mounting Tripod and Mast

Folding Bath Screen Instruction Manual

8.7 Schluter -KERDI-LINE

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Syphonic Roof Drainage

Vitraflex Classic Modular Combination Shower and Changeroom Cubicles (c/w Telescopic Stainless Steel Leg Anchors)

INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET

Awning Instructions. Standard Manual 1.5m to 4.5m

Waste Oil Handling, Spill Containment & Lighting

March 14, Installation of Bay, Bow and Garden Windows

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Linkeo 19" freestanding cabinets

Horizontal Mini Blinds Installation Guide

Bathroom Installation Guide

Panel Track Installation Guide

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

STATE BANK OF INDIA.

Guidelines for Earthquake Bracing Residential Water Heaters

Slides and Drawers. The right collection

Carekit accessible toilet solutions

OPL BASIC. Dosing System for Professional Laundry machines. Contents

RUBBER SLEEVE KNIFE GATE VALVE

FUTRUS WALL-MOUNT VANITY SINK SOLUTIONS WITH DUPONT CORIAN

Fall Protection Solutions

Colonnade Security Pipe

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

NEW. Teramo See Page 136

Transcription:

EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign

Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little easier for professionals as well as end consumers. For consumers, the advantages lie in Fresh WC and 4/2 flushing. For professionals there are further aspects. Based on a Nordic perspective. We know how a Nordic bathroom looks and how it works. Our modules only require wall mounting, which eliminates the risk of serious water damage, and all have seams outside walls for the same reason. Flexible bolt distances of 180 or 230 mm make the system flexible when it comes to choosing porcelain bowls. We have made the flush button installation easier as well. You do not have to cut the pin when adapting the button to the thickness of the wall. In addition, Ifö s installation system is equipped with a completely new flush mechanism that is based on the success of Sign. The function of the armature is not affected by calcification. The outlet valve is set as standard at 4/2 flushing but you can easily adjust the volume between two and eight litres. Ifö Sign installation system, the complete solution that makes everything easier. IFÖ SIGN INSTALLATION SYSTEM 3

Anewbutwelltested andthought-outsolution Our built-in cistern system has been developed by Ifö s engineers together with Nordic installers and is based on Nordic experience. This means that you do not have to break the membrane in the floor to install the installation system. Instead of screwing into the floor, four or six mounting points in the wall are used. Just as stable, but much safer. Another critical point is the connections. With our solution, all pipes are cut outside the wall, an efficient way of avoiding unnecessary water damage and extending the life of the bathroom. In addition, the cistern is prepared for pipe-in-pipe installation, another safety measure. The plastic used is of the best possible quality, a safety measure that ensures good operation. Ifö Sign installation elements have the minimum of loose parts. The element is supplied complete, which makes the adjustable stands very easy to install without the need for special tools. Add the fact that you always have access to spare parts and Ifö Sign installation system becomes an asset to you, your business and your customers year after year. 4 WWW.IFOSANITAR.COM/SIGN

Lettheroomtakecontrol Under the window For example, 1 ½ storey houses can sometimes require that the installation system s wall is low, for space under a slanting roof or a window. Ifö Sign installation system has several options to choose from. Close to the mains To get as close to a vertical waste pipe as possible, choose Ifö Sign installation system 1100 MC4. In addition, this is a space saving solution. You can use the installation system to enclose the waste pipe. IFÖ SIGN INSTALLATION SYSTEM 5

Installing elements in practice The material and design as well as products make the installation of Ifö Sign installation elements as easy and safe as possible. Once you have decided how to layout your bathroom it is then just a case of installing it. All Ifö elements are installed in the same way, regardless of whether the element is for a bidet or a WC. Step 4 Use the module as a template and drill holes. Screw the module into the wall using hexagon head screws. Adjust so that the module stands vertically. The adjustable wall mounting can be easily adjusted using an Allen key through the slits. Then lock the nuts. Step 1 Step 5 Install the top and floor mountings. Adjust to the desired depth. Screw in the flush pipe and lock using the supplied clamp. Complete installation Ifö installation system is quick and easy to install, not least thanks to depth and height adjustment. In addition, the installation is wet room proof as no holes have to be made in the floor s membrane. Step 2 Adjust the height and install the module so that it is level. Tips for safe water installation: Always use approved products. Follow the installation instructions. Check that the floor s drop meets the requirements for the wet areas. All screw mountings must be made into something solid, e.g. concrete, bolts or special reinforcements (Ifö no. 9641 ). Screw mountings must not be made into just the floor or wall panels. Step 3 Install the waste pipe before the element is secured to the wall. 6 WWW.IFOSANITAR.COM/SIGN Always leave a few millimetres between the installation wall and bathroom floor. Any water leaks inside the installation wall can then be easily detected and rectified. Always install the membrane inside the actual installation wall and preferably under tiles in the bathroom. Pipe lead-ins must be correctly made and use approved materials. Try to limit the number of pipe lead-ins and avoid having them inside the installation wall. Seal bolts and water/outlet lead-ins with mould resistant silicon. Screw holes for walls and floor mountings are also sealed with mould resistant silicon. Apply mould resistant silicon around the porcelain but leave an opening under the WC.

Elementsforeveryneed Ifö Sign installation elements form the base for a successful installation as they can easily be adjusted according to the requirements and space available. Ifö Sign WC-element 1100 Element Flushing rim height/ Anchoring height seat height height* 1080 400 320 1100 420 340 1140 460 380 Ifö Sign WC-element 840 Element Flushing rim height/ Anchoring height seat height height* 820 400 320 840 420 340 880 460 380 Ifö nr. 98980 Ifö Sign built-in cistern: Ifö nr. 96890 Ifö nr. 98981 Ifö Sign built-in cistern: Ifö nr. 96890 Ifö Sign WC-element 1100 MC6 with mini cistern top access Element Flush rim height/ Anchoring height seat height height* 1080 400 320 1100 420 340 1140 460 380 Ifö Sign Wash basin element 1100 for bolt and bracket mounting wash basins The wash basin height can be adjusted between 800-950 mm. Ifö nr. 98982 Ifö nr. 98898 350 200-250 230 1100 340 Ifö Sign Bidet module 1100 Ifö Sign Urinal element 1100 Element Rim height Anchoring height height* 1080 400 320 1100 420 340 1140 460 380 Ifö nr. 98984 Element height 1080 650 1100 650 1140 650 Ifö nr. 98985 Rim height IFÖ SIGN INSTALLATION SYSTEM 7

Flushbuttons There is a wide range of buttons for Ifö s WC built-in cisterns. Choose between Ifö s classic full or half flushing, mechanical or pneumatic. It is not just taste that influences the choice, practical things also matter, for instance whether you are to carry out service work from the front or top. If it has to be vandal proof, Public Steel is the choice for you. The mechanical buttons in the table below fit the Sign built-in cistern and are found in all Ifö Sign WC elements. Position the button in front of or on top of the cistern. The small pneumatic flush buttons do require an inspection shelf but there is a greater choice of locations. The only requirement is that you keep within two metres of the cistern. Matt Polished White Stainless steel Mechanical front cover with double flush Ifö nr: 96852 Ifö nr: 96851 Ifö nr: 96850 Ifö nr: 96858 Ifö nr: 96857 Ifö nr: 96856 Fresh WC Without Fresh WC Mechanical front cover with single flush Ifö nr: 9685 Ifö nr: 96859 Fresh WC Without Fresh WC Mechanical front cover (disabled adapted) with double flush Ifö nr: 96877 Ifö nr: 96876 Fresh WC Without Fresh WC Mechanical front cover with double flush Ifö nr: 96864 Ifö nr: 9686 Ifö nr: 96862 Fresh WC Pneumatic flush button with double flush Ifö nr: 96870 Ifö nr: 96869 Ifö nr: 96868 Fresh WC* Pneumatic flush button with single flush Ifö nr: 96872 Fresh WC* Pneumatic flush button (disabled adapted) Ifö nr. 96871 Fresh WC* Ifö Public Steel flush button Ifö nr: 96874 Ifö nr: 96875 Single flush with Fresh WC* Double flush with Fresh WC* Foot pedal Ifö nr: 9687 Fresh WC* Dosing hatch** Ifö nr: 96867 Ifö nr: 96866 Ifö nr: 96865 * A dosing hatch must be installed for Fresh WC. ** The dosing hatch can only be installed on the shelf above the module. 8 WWW.IFOSANITAR.COM/SIGN

FreshWC One of the biggest features is the integrated flush function which, at each flush, ensures that the WC unit is fresh, nicely scented and less vulnerable to calcification. Without having to use a cleaning block. Open the hatch and insert the Fresh WC tablet. As it is dry stored, it lasts longer. Close the hatch. A good dose of Fresh agent is released at each flush. All flush buttons have a vandal proof safety lock, which prevents unauthorised persons from accessing the Fresh WC tablet. Porcelain Combining Ifö Sign installation system and Ifö s wall mounted porcelain gives a wide range of advantages, not least when it comes to keeping the bathroom clean. Ifö s wall mounted Sign WC unit 6875 is a space saving and stylish solution. Ifö s WC units and wash basins are easy to install on Ifö Sign elements with concealed pipe routing. Products from the Public Steel range are also suitable for use with Ifö Sign installation systems. For more information about WC units, wash basins, Public Steel and urinals go to www.ifosanitar.com. Ifö Sign built-in cisterns have a 2.2 litre water flow per second and are approved according to cistern norm EN 14055. Ifö Sign wall mounted WC unit 6875 is approved according to norm EN 997. Ifö Sign Wall mounted WC bowl 6875 (Ifö nr. 6875) Wall mounted WC unit with smoother sides for easier cleaning. Installed together with Ifö Sign WC elements. Colours: white and sand Ifö Public Steel WC bowl (Ifö nr. 8510082) Stainless steel WC bowl with Teflon coating, for wall mounting. Installed together with Ifö Sign WC elements. Dark grey hard seat included. Colour: stainless steel IFÖ SIGN INSTALLATION SYSTEM 9

10 WWW.IFOSANITAR.COM/SIGN

Centre track profile The 36 mm wide centre track profile is made of aluminium and has large screw surfaces. Two lengths are available; 2500 mm and 1020 mm. All parts are suitable for use with the profiles, which makes it easy to assemble your solution and to attach components. 2500 mm: (Ifö nr. 96700) 1020 mm: (Ifö nr. 96702) Adjustable wall mounting Makes it possible to easily align and secure the profiles. Secure the fitting in the profile s centre track and then in the wall. Supplied in packs of two. (Ifö nr. 96706) Alexibleinstallationsystem With only a few parts to worry about and without the need of special tools, you can install Ifö Sign installation system in large and small spaces. The installation system s aluminium profiles are light, which makes them easy to transport. They are always straight, insensitive to moisture and so stable that you can assemble the system outside the bathroom before putting it in place. A valuable advantage when working with larger items. The material also makes it easy to use mouldings. The choice of wall material is important as it determines the maximum c/c dimension between the vertical bolts and if the wall can be tiled. The wall material is then screwed into the profiles or modules using self-tapping standard screws. We recommend double plasterboard if the walls are to be tiled. Wall material Double plasterboard/tiles max c/c 600 mm Corner fitting The sprung corner fitting makes it easy to connect the module and profile, and also to connect profiles. The fitting is hooked into the module s slits and the profile s centre track. Easy to adjust and tighten. Supplied in packs of four together with two rubber dampers. (Ifö nr. 96704) Single wall mounting For securing profiles in walls and ceilings. The single wall mounting is hooked into the profile and runs freely in the centre track. Provides some adjustment to facilitate installation. Supplied in packs of four. (Ifö nr. 96708) Reinforcement profile Fits all Ifö installation elements, for securing in stud walls. Screwed into existing bolts. (Ifö nr. 96413) Accompanying bolts, nuts and washers can be found in Ifö Securing kits. (Ifö nr. 98131) Connection element Used in cases where profiles have to be joined or extended, or to prevent swarf. If necessary, secure the connection element in the profile using screws. Supplied in packs of four. (Ifö nr. 96710) Flex pack The pack consists of two 1020 mm profiles, four corner fittings and four single wall mountings. A flex pack can be used to connect a module to a perpendicular wall a maximum of 510 mm away, and also has other uses. (Ifö nr. 98907) To calculate the materials required go to www.ifosanitar.com/sign IFÖ SIGN INSTALLATION SYSTEM 11

Multiple connection options Push buttons can be installed from above as well as from the front. More efficient and reliable flushing mechanism Ifö s installation system is equipped with a completely new built-in cistern that is based on the success of Ifö Sign floor mounted WC units. The function of the armature is not affected by calcification. Secure pipe installation The built-in cistern is prepared for pipe-in-pipe installation with many different locations for incoming water. Choice of porcelain Choose a bolt distance that suits the WC bowl to be installed. A flexible bolt distance of 180 or 230 mm means that the system can handle different types of bowls. Can hold up to 400 kg depending on type of bowl. No risk of water damage inside the wall The flush and waste pipes have no joins and are long enough to protrude from the wall. This means that any leaks from the flush and waste pipes do not accumulate in the wall but instead drain into the bathroom. Always comply with local and national regulations for damp-proofing and waterproof membranes in buildings and structures. No risk of water damage inside the floor Wall mounting only. This means that you do not have to make holes in the floor which can lead to serious water damage. Stable, flexible waste fittings Ifö s waste fittings are made of metal, which means tighter fastening. In addition, standard pipes of standard diameters can be used, which facilitates installation. Mounting is stepless.