ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

Similar documents
Electronic Flow Switches

Centro-Matic Automatic Lubrication Systems System Controls

In-Line Electronic Flow Switches

Sanitary Type Electronic Flow Switches

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

In-Line Electronic Flow Switches

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

SELECTION, APPLICATION AND MAINTENANCE

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

How To Use A Flowmeter

For Multi-Parameter Meters see mvx

HERZ-Thermal Actuators

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

SITRANS F flowmeters SITRANS F M

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Excellence through Versatility

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

HYDRUS ULTRASONIC METER

Electronic, Digital and Mechanical Vibration Switches

Heating, air-conditioning, cooling

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Phone: Fax: Web: info@clrwtr.com

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Flow switches Series AD/VH

Specifying a Variable Frequency Drive s

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

The conditions below apply to the curves shown on the following pages.

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Electric Rotary Actuator - On/Off or programmable control actuator

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

KNC Model 3666 Automatic Pressure Calibration System

ELECTROMAGNETIC FLOWMETER COMPACT

Conlift1, Conlift2, Conlift2 ph+

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Horizontal Jet Pumps 1/3-1-1/2 HP

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Digital inductive conductivity transmitter

Variable Area Flowmeters

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Scraper Passage Indicator. Electrical Indicator. Features

Assisted lift operated 2/2-way solenoid valves Type EV250B

ATL Fuel Level Sender Probes

MANTA Piston Distributor for Oil and Fluid Grease

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Compact pressure switch Flameproof enclosure Ex d Model PCA

IFC 070 Technical Datasheet

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Vacuum drying oven for non-flammable solvents

OPL BASIC. Dosing System for Professional Laundry machines. Contents

300 Series PA Pump and Cooler Assemblies

Tool Turrets and Tool Discs

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Liquid Level Limit Switch liquiphant T FTL 20

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

Magnum Mobile Generator MMG55 Specifications

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

CRN A-F-G-E-HQQE 3x400D 50 HZ

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Models SFP33 & SFP32 Pressure Transmitters

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

MCR1900 Media Converter 19-Slot Chassis

Series description: Wilo-Drain TC 40

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Know-how makes the difference. Electrical Actuators

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Digital Pressure Measuring Instrument MDR480

Panel Meters and Controllers Modular Panel Meter Type EDM 35

4 Posiflow Proportional Solenoid Valves

Thyristor-controlled power supplies and battery chargers

Series DFMT Digital Paddlewheel Flowmeter

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Typical Aluminum GFM Mass Flow Meter

MAC-120HE-01 Air-Cooled Chiller

Power consumption (kw)

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

MODEL INSTALLATION INSTRUCTIONS

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Plastic tube flowmeters Series PT/PS

NDP-50 Specifications

Transcription:

Overview: Sigma/ 3 (S3Cb) The Sigma/3 motor diaphragm are produced with a high-strength metal inner housing for parts subject to load as well as an additional plastic housing to protect against corrosion. The capacity range extends from 46.0 to 274.7 gph at a maximum backpressure of 174 to 58 psig. Stroke length is 0.24 in. Under defined conditions and when installed correctly, the reproducibility of the metering is better than ±2 % at a stroke length of between 30 % and 100 % (instructions in the operating instructions manual must be followed). In all without integrated overload protection, for safety reasons, suitable overload protection must be provided during installation. Sigma/ 3 Basic Type (S3Ba) The Sigma/ 3 basic type is a metering pump without internal electronics. Various NEMA 56C frame motors can be used depending upon the application requirements. The Sigma 3 Basic pump is also suitable for use with inverter duty and DC motors for varying flow requirements. DULCTEST pk_2_003 01/01/2012 - Sigma/ 3 97

Sigma/ 3 control type (S3Cb) For optional control via contact or analog signals (e.g. 0/4-20 ma) the Sigma control type pump results in good adaptability, even in fluctuating metering requirements. The microprocessor control is an optimum combination of speed control and stop & go operation, i.e. it works in a wide control field with customized fine adjustment. Moreover it enables an optimum metering result thanks to the metering behavior of the metering pump being matched to the chemicals or application. The control system measures the movement and speed profile in conjunction with the power demand. This leads to a real reduction in the actually required power, which means an increase in efficiency. Detachable operating unit (HMI) The operating unit (HMI) can be attached directly to the metering pump or mounted on the wall alongside the pump or completely removed. This provides the operator with a wide range of options for the integration of a metering system into the overall system that it is readily accessible and easy to use. Moreover, the removable operating unit offers additional protection against unauthorized operation of the metering pump or against changing of the pump settings. The individual functions of the metering pump can be easily selected and adjusted with five program keys. An illuminated LCD display provides information about the relevant operating status. LEDs on the operating unit and the control unit indicate the active pump functions or the pump status. The liquid end has a patented multilayer safety diaphragm as standard and a visual diaphragm rupture indicator. The diaphragm is coated on both sides with PTFE film. This coating ensures that no leakage to the outside occurs even if the diaphragm ruptures. If the diaphragm ruptures, feed chemical enters between the diaphragm layers and thus triggers a mechanical indication or an alarm via the sensor area. This concept ensures reliable metering - even under critical operating conditions. Diaphragm rupture warning system DULCOTEST 98 01/01/2012 - Sigma/ 3

Sigma/ 3 control type (S3Cb) Metering profiles Diagram 1: Discharge stroke, suction stroke equal Metering profiles ensure optimum metering results, thanks to the metering behavior of the metering pump being matched to the chemicals or application. The stroke movement of the diaphragm pump is continuously measured and controlled, so that the stroke is executed according to the desired metering profile. The pump can be operated in normal mode (Diagram 1), with optimized discharge stroke (Diagram 2) or with optimized suction stroke (Diagram 3). Three typical metering profiles are shown schematically with the behavior over time. In normal operating mode the time behavior for the suction stroke and the discharge stroke is similar (Diagram 1). In the mode with optimized discharge stroke (Diagram 2) the discharge stroke is lengthened while the suction stroke is executed as quickly as possible. This setting is, for example, useful for applications that require optimum mixing behavior and optimized chemical mixing. In the mode with the optimized suction stroke (diagram 3), the suction stroke is carried out as slowly as possible, which permits precise and trouble-free metering of viscous and gaseous media. This setting should also be chosen to minimize the NPSH value. Diagram 2: long discharge stroke, short suction stroke Diagram 3: short discharge stroke, long suction stroke DULCTEST 01/01/2012 - Sigma/ 3 99

Specifications (S3Ba and S3Cb) DULCOTEST General: Maximum stroke length: Power cord: Stroke frequency control: Stroke counting: Materials of construction Inner casing: Housing: 0.236" (6.0 mm) 6 foot (2 m) 2 wire + ground (supplied on control version) S3Ba: Constant speed or optional DC/SCR drive or AC inverter S3Cb: Microprocessor control version with innovative start/stop and variable speed control proportional to set frequency or external control signal. Standard on S3Cb Cast aluminum Glass-filled Luranyl (PPE) Wetted materials of construction: Liquid End: PVDF 316 SS Suct./Dis. Connectors: PVDF 316 SS Seals: PTFE PTFE Check Balls: DN 25 Glass SS Check Plates: DN 32 Hastelloy C Hastelloy C Viscosity ranges: Liquid end version strokes/min Viscosity (mpas) Standard 180 0-200 With valve springs 130 200-500 With valve springs and 90 500-1000* suction-side feed * Only when properly installed & adjusted Sound pressure level: Sound pressure level LpA < 70 db in accordance with EN ISO 20361:2010-10 at max. stroke length, max. stroke rate, max. back pressure (water) Drive: Cam and spring-follower (lost motion) Lubrication: Oil lubricated Recommended oil: ISO VG 460, such as Mobil Gear Oil 634s Oil quantity: Approximately 0.95 quart (900 ml) Recommended oil change interval: 5,000 hours Warranty: Two years on drive, one year on liquid end. Factory testing: Each pump is tested for rated flow at maximum pressure. Industry Standard: CE approved, CSA available (standard in Canada), NSF/ANSI 61 Diaphragm materials: PTFE faced EPDM with Nylon reinforcement and steel core Liquid end options: Polyvinylidene Fluoride (PVDF) or 316 SS with PTFE Check valves: DN 25 valves - Single ball check, PVDF and SS versions. Optional springs available (Hastelloy C4) DN 32 valves - Plate valves, with Hastelloy C4 plates and springs in both PVDF and SS valves. Repeatability: When used according to the operating instructions, better than ±2% fluid operating temperatures: Material Constant Short Term Minimum ( Backpressure) (15 min. @ max.30 psi) temperature PVDF 149 F (65 C) 212 F (100 C) 14 F (-10 C) 316 SS 194 F (90 C) 248 F (120 C) 14 F (-10 C) Diaphragm failure indication: Visual indicator is mandatory. The delivery unit has a patented multilayer safety diaphragm as standard and a visual diaphragm rupture indicator. Separation of drive from liquid end: An air gap with secondary safety diaphragm separates the drive from the liquid end to prevent cross contamination of oil and process fluid (with or without optional diaphragm failure indication). solids size in fluid: 0.3 mm Stroke length adjustment: Manual, in increments of 0.5%. Motorized stroke length adjustment available. 100 01/01/2012 - Sigma/ 3

Specifications (S3Ba and S3Cb) Cont. Basic Version Motor mounting flange: Gear ratios and stroke frequencies (with 1725 RPM motor): Motor coupling: Required Motor HP: Full load RPM: Stroke sensor (optional): Control Version Control Function: Fits all NEMA 56C frame motors (motor not included with pump) 20:1 = 86 SPM, 14:1 = 124 SPM, 10.1: = 173 SPM Flexible coupling included with pump. 3/4 HP (.55 kw) 1750 RPM (60 Hz) Hall effect - requires 5 VDC At stroke frequencies equal to or greater than 33%, the integral AC variable frequency drive continuously varies the motor speed in a linear response to the incoming signal. At stroke frequencies less than 33%, the motor starts and stops according to a control algorithm to provide the desired stroke fre quency. In the start-stop mode the motor speed is constant at approximately 580 RPM. Enclosure rating: IP 65 Motor data: Totally enclosed, fan cooled (IP55); class F insulation; Manufacturer ATB; 0.55 kw (0.75 HP) 230 3 phase (2.5 A, 1710 rpm) Relay load Fault relay only (Option 1): Fault relay with pacing relay (Option 3): Contact load: 250 VAC, 8 A, 50/60 Hz Operating life: > 200,000 switch functions Fault Relay Contact load: 24 V, 100 ma, 50/60 Hz Operating life: > 200,000 switch functions Pacing relay Residual impedance in ON-position (R DSOn ): < 8 Ω Residual current in OFF-position: <1µA Maximum voltage: 24 VDC Maximum current: < 100 ma (for pacing relay) Switch functions: 750x10 6 Contact closure: 100 ms (for pacing relay) Air Humidity Fuse: Analog output signal: Bus interface options available: Relay cable (optional): Pulse contact/remote pause contact: Contact input max. pulse frequency: Contact input impedance: pulse memory: Necessary contact duration: Analog - current input burden: allowable input current: Input power requirements: air humidity*: 95% rel. humidity * non-condensing Internal, 6.3 AT - (1.5 ka) impedance 300 Ω Isolated 4-20 ma output signal CANopen, PROFIBUS DP 6 feet (2 m) 3 wire (SPDT) 250 VAC, 2 A With voltage-free contact, or semiconductor sink logic control (not source logic) with a residual voltage of <700 mv. The contact load is approximately 0.5 ma at + 5 VDC. (Note: Semiconductor contacts that require >700 mv across a closed contact should not be used.) 25 pulses/sec 10 kohm 65,535 pulses 20ms Approximately 120 Ohm 50 ma single phase, 115-230 VAC DULCTEST 01/01/2012 - Sigma/ 3 101

Capacity Data (S3Ba) Capacity data: Sigma/ 3 Basic Version Capacity Data (S3Cb) Capacity data: Sigma/ 3 Control Version Stroke Rate Capacity at Output per Suction/ Discharge Pump Version Backpressure Stroke (water) Pressure Connector (approx.) S3Ba H psig (bar) GPH (L/h) spm ml/stroke ft (m) psig (bar) in (DN) lbs (kg) 120145 PVT 145 (10) 46 (174) 86 33.7 16 (5) 29 (2) 1 MNPT (25) 49 (22) 120145 SST 174 (12) 46 (174) 86 33.7 16 (5) 29 (2) 1 MNPT (25) 57 (26) 120190 PVT 145 (10) 66.2 (251) 124 33.7 16 (5) 29 (2) 1 MNPT (25) 49 (22) 120190 SST 174 (12) 66.2 (251) 124 33.7 16 (5) 29 (2) 1 MNPT (25) 57 (26) 120270 PVT 145 (10) 92.6 (350) 173 33.8 16 (5) 29 (2) 1 MNPT (25) 49 (22) 120270 SST 174 (12) 92.6 (350) 173 33.8 16 (5) 29 (2) 1 MNPT (25) 57 (26) 070410 PVT 100 (7) 130 (492) 86 95.1 13 (4) 14.5 (1) 1-1/2 MNPT (32) 53 (24) 070410 SST 100 (7) 130 (492) 86 95.1 13 (4) 14.5 (1) 1-1/2 MNPT (32) 64 (29) 070580 PVT 100 (7) 183.9 (696) 124 95.1 13 (4) 14.5 (1) 1-1/2 MNPT (32) 53 (24) 070580 SST 100 (7) 183.9 (696) 124 95.1 13 (4) 14.5 (1) 1-1/2 MNPT (32) 64 (29) 040830 PVT 58 (4) 264.2 (1000) 173 95.1 10 (3) 14.5 (1) 1-1/2 MNPT (32) 53 (24) 040830 SST 58 (4) 264.2 (1000) 173 95.1 10 (3) 14.5 (1) 1-1/2 MNPT (32) 64 (29) Stroke Rate Suction Lift Suction Lift Suction Suction Shipping Weight w/motor Shipping Weight w/motor Capacity at Output per Suction/ Discharge Pump Version Backpressure Stroke (water) Pressure Connector (approx.) S3Cb H psig (bar) GPH (L/h) spm ml/stroke ft (m) psig (bar) in (DN) lbs (kg) 120145 PVT 145 (10) 48.1 (182) 90 33.7 16 (5) 29 (2) 1 MNPT (25) 49 (22) 120145 SST 174 (12) 48.1 (182) 90 33.7 16 (5) 29 (2) 1 MNPT (25) 57 (26) 120190 PVT 145 (10) 64.2 (243) 120 33.7 16 (5) 29 (2) 1 MNPT (25) 49 (22) 120190 SST 174 (12) 64.2 (243) 120 33.7 16 (5) 29 (2) 1 MNPT (25) 57 (26) 120270 PVT 145 (10) 96.4 (365) 180 33.8 16 (5) 29 (2) 1 MNPT (25) 49 (22) 120270 SST 174 (12) 96.4 (365) 180 33.8 16 (5) 29 (2) 1 MNPT (25) 57 (26) 070410 PVT 100 (7) 132.1 (500) 90 95.1 13 (4) 14.5 (1) 1-1/2 MNPT (32) 53 (24) 070410 SST 100 (7) 132.1 (500) 90 95.1 13 (4) 14.5 (1) 1-1/2 MNPT (32) 64 (29) 070580 PVT 100 (7) 177 (670) 120 95.1 13 (4) 14.5 (1) 1-1/2 MNPT (32) 53 (24) 070580 SST 100 (7) 177 (670) 120 95.1 13 (4) 14.5 (1) 1-1/2 MNPT (32) 64 (29) 040830 PVT 58 (4) 274.7 (1040) 180 95.1 10 (3) 14.5 (1) 1-1/2 MNPT (32) 53 (24) 040830 SST 58 (4) 274.7 (1040) 180 95.1 10 (3) 14.5 (1) 1-1/2 MNPT (32) 64 (29) Materials In Contact With Chemical Material Suction/discharge DN 25 DN 32 connector Seals Valve balls Valve seats Seals Valve Plate/ Valve seats Liquid end Spring PVT PVDF PTFE Glass PTFE PTFE Ceramic/ PTFE (Polyvinylidenefluoride) Hast. C + CTFE** SST Stainless steel PTFE Stainless steel PTFE PTFE Stainless steel PTFE DULCOTEST 102 01/01/2012 - Sigma/ 3

Identcode Ordering System (S3Ba) S3Ba Drive Type H Main Drive, Diaphragm Version: 120145 Capacity: 46.0 gph (174 l/h), 145 psi (10 bar) 070410 130.0 gph (492 l/h), 100 psi (7 bar) 120190 66.2 gph (251 l/h), 145 psi (10 bar) 070580 183.9 gph (696 l/h), 100 psi (7 bar) Note: For SS versions see capacity data 120270 92.6 gph (350 l/h), 145 psi (10 bar) 040830 264.2 gph (1000 l/h), 58 psi (4 bar) Liquid end material: PV PVDF SS 316 Stainless Steel Seal: T PTFE Diaphragm type: S Safety diaphragm w/ visual indicator A Safety diaphragm w/ pump stop fuction Liquid end version: 0 Without valve springs 1 With 2 valve springs (Hastelloy C4, 1 psig) Hydraulic connections: 7 PVDF clamping nut & insert 8 SS clamping nut & insert Logo: 0 Standard with logo Motor mount: 2 Without motor, with NEMA 56C flange Enclosure rating: 0 Standard Stroke sensor: 0 Without stroke sensor (Standard) 2 With Pacing relay (Consult Factory) Stroke length adjustment: 0 1 2 4 6 Manual (Standard) with 3P stroke positioning motor, 230 V 50/60 Hz with 3P stroke positioning motor, 115 V 50/60 Hz W/ stroke positioning motor 4-20 ma, 230 V 50/60 Hz W/ stroke positioning motor 4-20 ma, 115 V 50/60 Hz S3Ba H 120145 PV T 0 0 7 0 2 0 0 0 DULCTEST 01/01/2012 - Sigma/ 3 103

Identcode Ordering System (S3Cb) S3Cb Drive Type H Main Drive, Diaphragm Version: Capacity: 120145 48.1 gph (182 l/h), 145 psi (10 bar) 070410 132.1 gph (500 l/h), 100 psi (7 bar) 120190 64.2 gph (243 l/h), 145 psi (10 bar) 070580 177 gph (670 l/h), 100 psi (7 bar) Note: For SS versions see capacity data 120270 96.4 gph (365 l/h), 145 psi (10 bar) 040830 274.7 gph (1040 l/h), 58 psi (4 bar) Liquid end material: PV PVDF max. 145 psi (10 bar) SS Stainless Steel Seal: T PVDF with PTFE/Viton seal Diaphragm type: S Multi-layer safety diaphragm w/ visual indicator A Multi-layer safety diaphragm w/ pump stop function Liquid end version: 0 Without valve springs 1 With 2 valve springs (Hastelloy C4, 1 psig) Hydraulic connections: 0 Standard connection 7 PVDF clamping nut & insert 8 Stainless steel clamping nut & insert Logo: 0 Standard with ProMinent logo Electrical Connection (± 10%): U 1ph, 115 V - 230 V 50/60Hz Cable and plug: 8 Open end 3m UL/CSA 115/230V D North American plug, 115 V X Without cable Relay: 0 Without relay 1 Fault annunciating relay 3 Option 1 + Pacing Relay 8 Option 3 + 4-20 ma output Control variant: 0 Manual + External with pulse control (mult/div) 1 Manual + External with pulse control & analog 6 *Option 1 + PROFIBUS (M12 Plug) Over Pressure Shut-off: 0 Without over pressure shut-off Operating unit (HMI): S HMI + 1.64' (0.5m) cable 1 HMI + 6.5' (2.0 m) cable 2 HMI + 16.4' (5.0 m) cable X Without HMI Access Code: 0 Without access code 1 Access code Language: EN English Approval: 01 CE S3Cb H 120145 PV T A 0 7 0 U D 0 0 0 1 0 EN 01 *With the option PROFIBUS -DP no relay can be selected DULCOTEST 104 01/01/2012 - Sigma/ 3

Dimensional Drawing: (S3Ba) C A.C. motor - dimensions may vary 8.4 (214) A B 17.8 (453) 7 (178) 1.8 (45).4 (10).3 (6.5) 4.7 (120) D 4.7 (120) 5.4 (136) 8.9 (225) E Dimensions in inches (mm) Suction/ Discharge Valve Thread Type Sigma/3 A B C* D D1** E E1** F 121045, 120190, 120270 PVT 14.1 14.3 1" MNPT 4.7 5.5 13.6 14.4 6.1 (358) (364) (120) (140) (346) (366) (156) SST 14.1 14.3 1" MNPT 4.8 5.6 13.7 14.5 6.1 (358) (364) (121) (141) (349) (369) (156) 070410, 070580, 040830 PVT 15.9 17.8 1-1/2" MNPT 5.0 5.7 14.0 14.8 8.1 (403) (453) (127) (147) (358) (378) (206) 15.3 16.9 1-1/2" MNPT 5.0 5.7 14.0 14.8 8.1 SST (387) (430) (127) (147) (358) (378) (206) * Piping adapters provided according to technical data. ** Dimensions with diaphragm failure detector. DULCTEST 01/01/2012 - Sigma/ 3 105

Dimensional Drawing: (S3Cb) 4.7 5.6 5.6 D E 1.1 Ø.25 4.7 10.0 10.9 17.9 A DULCOTEST Dimensions in inches (mm) B Type Sigma 3 A B C* D E 121045, 120190, 120270 PVT 10.1 (257) 6.95 (177) DN 15 4.4 (111) 5.7 (144) SS 10.9 (276) 8.2 (208) DN 15 4.3 (110) 5.2 (133) 070410, 070580, 040830 PVT 13.3 (337) 13.1 (332) DN 25 4.6 (117) 6.1 (155) SS 13.3 (337) 13.1 (332) DN 25 4.6 (117) 5.8 (147) * Suction/ Discharge valve thread Piping adapters provided according to technical data 7.0 106 01/01/2012 - Sigma/ 3