Electronic timer CT-TGS Pulse generator with 1 c/o contact Data sheet

Similar documents
Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relay CM-PFE

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Pluggable interface relays CR-P Pcb relays

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

38 Series - Relay interface modules A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 Series - Relay interface modules A

Thermistor motor protection

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

48 SERIES Relay interface modules 10 A

MasterINTERFACE 39 Series - Relay interface modules

RM4TG20 three-phase network control relay RM4-T - range V

Safety technique. Emergency stop module BO 5988 safemaster

Analog signal converters CC-E I/I Current / current isolators

80 Series - Modular timers 16 A. Features

Electronic overload relay EF19 and EF45

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Electronic overload relay EF65, EF96 and EF146

MasterINTERFACE 39 Series - Relay interface modules

Catalog. Modular DIN rail components Installation contactors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

49 Series - Relay interface modules A. Features

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

EMR measuring and monitoring relays

mecotron Safety relay ESTOP-2 For emergency stop monitoring

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

80 Series - Modular timers 16 A. Features

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Quick Connect. quick - simple - efficient.

Relés e Contatores de Estado Sólido SIRIUS

RY2 miniature industrial relays

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Type: DILM50(230V50HZ,240V60HZ) Article No.:

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

ABB i-bus KNX SA/S Switch Actuators Product Manual

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

15 Series - Electronic step relay and dimmer. Features SERIE

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Type: DILM32 10(24V50HZ) Article No.:

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PHOENIX CONTACT Features

PNOZsigma - Base units

Rack mounted telephone- and leased line modem for industrial applications

Panel Meters and Controllers Modular Panel Meter Type EDM 35

E-STOP relays, safety gate monitors

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

40 Series - Miniature PCB/Plug-in relays A. Features

Signal converters Index

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Type: DILM9 10(24VDC) Article No.:

R.C.C.B. s two-pole LEXIC

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Technical catalogue. Modular DIN rail components Installation contactors

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Telephone- and leased line modem for industrial applications TD-36

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Multifunction devices

60 Series - General purpose relays 6-10 A. Features

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Safety Relays ESM/ESM-F

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Contact expansion modules

Short information Parameters are programmed via front-side membrane keypad

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

DS 600. A contact free flux gate based current measurement sensor 600A rms

E-STOP relays, safety gate monitors

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Actuator-Sensor-Interface

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

HERZ-Thermal Actuators

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Contact expander modules

CompactLogix Power Supplies Specifications

Transcription:

1SVR 430 163 F0100 CT-TGS 1 5 3 6 7 4 8 1 10 selectable time ranges, from 0.05 s to 300 h, for the adjustment of the ON time Potentiometer with direct reading scale for the fine adjustment of the ON time 3 10 selectable time ranges, from 0.05 s to 300 h, for the adjustment of the OFF time 4 Potentiometer with direct reading scale for the fine adjustment of the OFF time 5 U/T: green LED - Supply voltage (LED flashes during timing) 6 R1: red LED - Output relay 1 energized 7 Circuit diagram 8 Marker label Characteristics Single-function timer, pulse generator with asymmetrical ON & OFF times One device includes independent timing circuits with 10 time ranges each, from 0.05 s to 300 h, for the adjustment of the ON & OFF times Remote potentiometer connection 1 c/o contact Volt-free (dry) control contact Starting the time delay is possible: - via an external control contact or - via the supply voltage Pause timing / time storage is possible via an external control contact LEDs for status indication Width.5 mm Approvals a b e f Marks g c culus GL GOST CCC CE C-Tick Order data Type Supply voltage Order code CT-TGS 4 V, 4-48V AC/DC, 110-40 V AC 1SVR 430 163 R0100 Order data (Accessories) Description Remote potentiometer 30.5 mm Remote potentiometer.5 mm Remote potentiometer 10.5 mm Adapter for screw mounting on panel Sealable cover Marker label Order code 1SVR 700 800 R1000 1SVR 701 800 R1000 1SVR 14 017 R0900 1SVR 430 09 R0100 1SVR 430 005 R0100 1SVR 366 017 R0100 Application The CT-S range timers are designed for use in industrial applications. They operate over a universal range of supply voltages and a large time delay range, within compact dimensions. The easy-to-set front-face potentiometers, with direct reading scales, provide accurate time delay adjustment. Operating mode The CT-TGS with 1 c/o contact provides independent timing circuits, one for adjustment of the ON time and one for adjustment of the OFF time. Two rotary switches, on the front of the unit, allow selection of one of 10 time ranges from 0.05 s to 300 h for each time delay. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit. When external potentiometers are connected to terminals Z1-, Z3- respectively, the internal adjustments are disabled and external adjustments are enabled. Timing is displayed by a flashing green LED labelled U/T. 1

Function diagram H Pulse generator with asymmetrical ON & OFF times (Recycling unequal times) Applying supply voltage to terminals A1/B1/B-A, starts timing. Timing starts with the OFF time first. If a jumper wire is connected to input X- (see below), the timer starts with the ON time first. The ON & OFF times are displayed by the flashing green LED. Timing can be paused by closing control contact X1-. The elapsed time is stored and continues from this time value when X1- is re-opened. This can be repeated as often as required. When two external potentiometers are connected to terminals Z1- and Z3-, the internal, front-face potentiometers are disabled and the time adjustment is made via the external potentiometers. A1/B1/B-A X- 15-18 15-16 X1- green LED CDC 5 077 F005 t p t i t 1 t s t t 1 tst t p = OFF time t i = ON time t s = Storage time (when time stop) t p /t i = t 1 + t (when time stop) Selection starting with ON or OFF time: X- (open) = starting with OFF X- (closed) = starting with ON Remote potentiometer connection: Z1-: OFF time Z3-: ON time Connection diagram H CT-TGS A1 Z1 15 B1 Z3 B1 A1 15 B A 16 18 B X1 X 18 16 A CDC 5 118 F0005 Version: 1SVR 430 163 R0100 A1-A Supply: 110-40 V AC B1-A Supply: 4 V AC/DC B-A Supply: 4-48 V AC/DC Z1- Remote potentiometer (OFF time) Z3- Remote potentiometer (ON time) X1- Control contact to start timing X- Control contact to changeover starting with ON / OFF 15-16/18 c/o contact

Wiring notes Connection diagram for remote potentiometer L1 A1 Z1 Z1 Z1 CDC 5 77 F005 A Potentiometer 50 k N Connection diagram for proximity switch (3 wire) with 30 V AC supply L1 L+ A1 30 V / AC 4 V / DC CDC 5 79 F005 N A Proximity switch L- Connection diagram for proximity switch (3 wire) with 4 V DC supply L+ B1 CDC 5 80 F005 A Proximity switch L- Connection diagram for control contacts L1/L+ A1 X1 A X1 start timing X1 pause timing / time storage CDC 5 78 F005 N/L- 3

Technical Data Input circuits Supply voltage A1-A 110-40 V AC B1-A 4 V AC/DC B-A 4-48 V AC/DC Power consumption 110-40 V AC approx..5-1 VA 4 V AC/DC approx. 0.5 VA/W 4-48 V AC/DC approx. 1.8 VA/W Supply voltage tolerance -15...+10 % Supply voltage frequency AC/DC Version DC or 50/60 Hz AC Version 50/60 Hz Control contact connections volt-free (dry) - start timing external X1- time pause, time storage Minimum control pulse length 0 ms Non-load voltage at the control contacts 10-40 V DC (no galvanic separation to supply circuit) Max. current in the control circuit 1 ma Max. cable length to the control inputs 50 m Remote potentiometer connection Z1/Z3-50 kz Max. cable length to remote potentiometer x 5 m, shield connected to potential Duty time 100 % Timing circuit Time ranges 0.05 s - 300 h 1) 0.05-1 s ) 0.15-3 s 3) 0.5-10 s 4) 1.5-30 s 5) 5-100 s 6) 15-300 s 7) 1.5-30 min 8) 15-300 min 9) 1.5-30 h 10) 15-300 h Recovery time < 50 ms Repeat accuracy (constant parameters) < 0. % Timing error within the supply voltage tolerance range < 0.008 % / % d U Timing error within operating temperature range < 0.07 % / C Indication of operational states Supply voltage / timer output relay energized green LED steady / flashing while timing red LED Output circuits 15-16/18 Number of contacts Relays, 1 c/o contact Contact material AgCdO Related voltage acc. to VDE 0110, IEC 60947-1 50 V Maximum switching voltage 50 V AC, 50 V DC Rated switching current acc. to IEC 60947-5-1 AC-1 (resistive) 30 V 4 A AC-15 (inductive) 30 V 3 A DC-1 (resistive) 4 V 4 A DC-15 (inductive) 4 V A Maximum lifetime mechanical 30 x 10 6 switching cycles electrical (AC-1, 30 V, 4 A) 0.1 x 10 6 switching cycles Short circuit proof, max. fuse rating n/c 10 A fast, operating class gl n/o 10 A fast, operating class gl General data Enclosure width.5 mm length 78.0 mm depth 100.0 mm Wire size fine-strand with wire end ferrule x 0.75 -.5 mm (18-14 AWG) fine-strand without wire end ferrule rigid x 0.5-4 mm (0-1 AWG) Weight approx. 150 g (5.3 oz) 4

Mounting position any Degree of protection enclosure / terminals IP50 / IP0 Temperature operating -0...+60 C storage -40...+85 C Mounting DIN rail (EN 500) Standards Product standard IEC 6181-1, EN 6181-1 EMC Directive 89/336/EEC Electromagnetic compatibility IEC 61000-6-, EN 61000-6-4 ESD acc. to IEC 61000-4-, EN 61000-4- level 3 6 kv / 8 kv HF radiation resistance acc. to IEC 61000-4-3, EN 61000-4-3 level 3 10 V/m Burst acc. to IEC 61000-4-4, EN 61000-4-4 level 3 kv / 5 khz Surge acc. to IEC 1000-4-5, EN 61000-4-5 level 4 kv L-L HF line emission acc. to IEC 1000-4-6, EN 61000-4-6 level 3 10 V Low Voltage Directive 73/3/EEC Operational reliability acc. to IEC 68--6 4 g Mechanical resistance acc. to IEC 68--6 6 g Approvals / marks Approvals Marks culus, GL, GOST and CCC CE and C-Tick Isolation data Rated insulation voltage between supply circuit, acc. to VDE 0110, IEC 60947-1 supply up to 40 V: 300 V control circuit and output circuit supply up to 440 V: 500 V Rated impulse withstand voltage between all isolated circuits acc. to VDE 0110, IEC 664 4 kv / 1.-50 µs Test voltage between all isolated circuits.5 kv, 50 Hz, 1 min. Pollution category acc. to VDE 0110, IEC 664, IEC 55-5 III/C Overvoltage category acc. to VDE 0110, IEC 664, IEC 55-5 III/C Environmental testing acc. to IEC 68--30 4 h cycle time, 55 C, 93 % rel., 96 h Load limit curves AC load (resistive) V V 300 00 100 80 60 50 40 30 0 CDC 5 194 F005 10 0.1 0. 0.5 1 4 6 10 I A DC load (resistive) V V 300 00 100 80 60 50 40 30 0 CDC 5 193 F005 10 0.1 0. 0.5 1 4 6 10 I A 5

Derating factor F for inductive AC load 1.0 0.9 0.8 F 0.7 0.6 0.5 CDC 5 19 F005 0.1 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Contact lifetime /switching cycles N N 10 5 9 8 5 4 3 10 4 1 3 4 5 6 7 8 I A CDC 5 191 F005 0 V 50 Hz 1 AC 360 cycles/h Dimensional drawings Dimensions in mm 109,5 4.31,5.886 10 4.0 78 3.07 CDC 5 188 F0005 100 3.94 Dimensional drawings (Accessories) ø36 DIA. 1.4 ø30 DIA. 1.18 1...7.39...75 CDC 5 184 F0005 33 40 1.30 1.57 Remote potentiometer 30.5 mm ø9 DIA. 1.14 ø DIA..866 1...7.39...75 CDC 5 183 F0005 33 4 1.30 1.65 Remote potentiometer.5 mm 6

3,5.138 50 max. 5 1.97 max. ø DIA..866 6 1.0 0.787 CDC 5 18 F0005 Remote potentiometer 10.5 mm 4,5.177 6,5.46 11,5.453 10.394,5.886 CDC 5 187 F0005 60.36 Adapter for screw mounting on panel.70,5.886 7.75 3,5.138 68,5 CDC 5 185 F0005 front-to-back size 107 Sealable cover 3A11 0.787 8.315 CDC 5 186 F0005 Marker label 7

Druckschrift-Nummer. CDC 111 08 D001 Printed in the Federal Republik of Germany (08/05) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 8 6913 Heidelberg, Deutschland Postfach 10 16 80 69006 Heidelberg, Deutschland Internet http://www.abb.com/lowvoltage -> Control Products -> Electronic Relays E-Mail epr-support@stotzkontakt.de