Free Residual Chlorine, Dissolved Oxygen, and Dissolved Ozone Amperometric Sensors

Similar documents
Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

For additional information, please visit our website at

General Purpose ph/orp Sensors

Trace Dissolved Oxygen Sensor

General Purpose ph/orp Sensor

Toroidal Conductivity Sensor

Submersion/Insertion Toroidal Sensor

Dissolved Oxygen Sensors

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

Multi-Parameter Electrochemical / Optical Water Quality System

ENDURANCE Conductivity Sensors

Submersion/Insertion Toroidal Sensor

Galvanic Parts Per Million Dissolved Oxygen Systems

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

Stainless Steel Dissolved Oxygen Electrodes

Sanitary and CIP Toroidal Sensor

DissolvedOxygenMonitor

CONDUCTIVITY, ph/orp, & AMPEROMETRIC HART ANALYZERS/CONTROLLERS

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

DISSOLVED OXYGEN PROBE

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Electronic Flow Switches

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

MC4-50 Feeding System

PART 1 - INTRODUCTION...

Digital inductive conductivity transmitter

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

Sanitary Type Electronic Flow Switches

Typical Aluminum GFM Mass Flow Meter

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

SITRANS F flowmeters SITRANS F M

Rosemount 1199 Submersible Seal

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

In-Line Electronic Flow Switches

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

DISSOLVED OXYGEN METER Model : DO-5509

Thermal Mass Flow Meter (Series MST)

Milwaukee USER MANUAL

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Combination ph/redox (ORP) Sensors

Model 111 Mass Flow Instruments

Rosemount 1199 Submersible Seal

The Unique Accelabar Flow Meter

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

automatic Changeover regulators and systems manifolds/changeover regulators

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

How To Use A Flowmeter

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

How To Water System

Stainless Steel Valves For the Sanitary Industries

Powers Controls TH 192 S Single Temperature Room Thermostat

NDP-50 Specifications

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

More inside :: Tackle even the toughest water treatment piping challenges with

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

300 Series PA Pump and Cooler Assemblies

Many Products...One Source

08.08 Vic-Check Valves

Block and Bleed Gauge Valves M25 and M251

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Installing a Probe. Typical Installation

TY-FLO Needle Valves

Micro Motion Model D and DL Coriolis Flow and Density Meters

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

USP CLASS VI GASKETS PRODUCTS OF INTEGRITY...FROM PEOPLE OF INTEGRITY

Analytical Sensors. Comprehensive Liquid Analysis Sensors Optimized for Pure Water Treatment. THORNTON Leading Pure Water Analytics

8 Chemicals from water treatment and distribution

Turbine Flowmeters for Gas Applications

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Installation Instructions

Basic Chemistry of Chlorination

Water Technologies Wallace & Tiernan Flow Measurement Equipment. Purge, Flow and Varea-Meter Products

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

RTD Temperature Probe for the Food/Pharmaceutical Industry

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

pvc well casing & drop pipe

KF Needle & Gauge Valves

Mass Flow Meters & Controllers

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

PortaSens ll G AS DETECTOR

EVAPCO ENGINEERING. Commercial HVAC. District Energy. Industrial Process. Industrial Refrigeration. Power

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

6 H2O + 6 CO 2 (g) + energy

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Regulator Options and Accessories

kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani

SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY


FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Transcription:

Models 499A CL, DO, OZ Product Data Sheet PDS 71-499A November 1998 Free Residual Chlorine, Dissolved Oxygen, and Dissolved Ozone Amperometric Sensors SIMPLE INSTALLATION for continuous process monitoring. RUGGED, molded Noryl 1 (PPO) construction. EASILY REPLACEABLE MEMBRANE. NO TOOLS REQUIRED to change Screw-On Membrane Retainer. AMPEROMETRIC MEASUREMENT for excellent stability and high accuracy. AUTOMATIC COMPENSATION for changes in membrane permeability with temperature. AUTOMATIC PRESSURE EQUALIZATION to maintain correct membrane tension. FEATURES Durability and easy maintenance characterize the Rosemount Analytical Model 499A membrane-covered amperometric sensors. The sensors have rugged molded Noryl (polyphenylene oxide) bodies and are suitable for flow-through or submersion mounting. Pressure changes have little influence on sensor response. A flexible bladder in the sensor prevents distortion of the membrane by keeping the pressure inside the sensor equal to the sample pressure. Maintenance is fast and easy. Replacing the membrane requires no special tools or fixtures. Simply place the membrane assembly on the cathode and screw the retainer in place. Installing a new membrane and replenishing the electrolyte takes only a few minutes. A Pt 100 RTD in the sensor (Delta-compatible sensors use thermistors) allows correction for changes in sensor output caused by temperatureinduced variations in membrane permeability. The sensors are compatible with Rosemount Analytical Model 1054A and 1054B amperometric analyzers and with the Delta 900, 5310, and 8200/8300 series amperometric instruments. See the compatibility table on page 3 for details. FREE RESIDUAL CHLORINE SENSOR: APPLICATIONS The Model 499A CL sensor is intended for the continuous measurement of free residual chlorine in the range 0 to 3 ppm. Free residual chlorine is the mixture of hypochlorous acid and hypochlorite ion created when chlorine gas or sodium hypochlorite is dissolved in water. The sensor is not intended for the determination of combined chlorine (chloramines) or other halogen oxidants (chlorine dioxide, bromine, or iodine). For the determination of higher levels of chlorine (3-20 ppm), consult the factory. Chlorine finds extensive use as a disinfectant in potable water filter plants and in wastewater treatment facilities. Most plants are required by law to continuously monitor chlorine in the finished water or in the plant effluent. Free chlorine measurements are also made in the food and pharmaceutical industries, where chlorine is used to disinfect process streams. Chlorine is also an effective algaecide in open cooling water systems. continued on page 2

continued from page 1 DISSOLVED OXYGEN SENSOR: APPLICATIONS The Model 499A DO sensor is designed for the continuous determination of dissolved oxygen in water in the range 0 to 20 ppm. The primary application is aeration basins in municipal and industrial wastewater treatment plants. The sensor can also be used to measure dissolved oxygen in aquaculture ponds. DISSOLVED OZONE SENSOR: APPLICATIONS The Model 499A OZ sensor is intended for the continuous determination of dissolved ozone in water in the range 0 to 10 ppm. Potable water filter plants are major users of ozone. Treating the raw water with ozone reduces the amount of filter aid chemicals (coagulants and flocculants) needed and lowers plant operating costs. Pretreatment with ozone also reduces the amount of chlorine needed to disinfect the finished water. Lowering the chlorine feed reduces the level of harmful chlorination by-products (trihalomethanes) in the product water. Ozone is also used as a disinfectant in bottling plants. 1 Noryl is a registered trademark of General Electric SENSOR SPECIFICATIONS ALL 499A AMPEROMETRIC SENSORS: Pressure: 0 to 65 psig (0 to 549 kpa) Temperature: 32 to 122 F (0 to 50 C) Dimensions: 1.0 x 5.6 in. (25 x 143 mm) Process Connection: 1 inch MNPT Electrolyte Volume: 25 ml (approx.) Electrolyte Life: 4 to 6 months (approx.) Cable Length (standard): 25 ft (7.6 m) Weight/Shipping Weight: 1 lb/3 lb (0.5 kg/1.5 kg) 499A DO SENSORS: Wetted Parts: Noryl, Viton, EPDM, gold, Teflon 2, silicone Range: 0 to 20 ppm (mg/l) as O 2 Maximum Cable Length: 300 ft (91 m) Sample Flow: Flow through Open channel Low flow cell 1 to 5 gpm (3.8 to 19 L/min) 1 ft/sec (0.3 m/sec) 2 to 5 gph (7.6 to 19 L/hr) 499A CL SENSORS: Wetted Parts: Noryl, Viton 1, EPDM, wood, platinum, silicone Range: 0 to 3 ppm (mg/l) as Cl 2. For higher levels (3-20 ppm), consult the factory. Maximum Cable Length: 200 ft (61 m) Sample Flow: 499A OZ SENSORS: Wetted Parts: Noryl, Viton, EPDM, gold, Teflon, silicone Range: 0 to 10 ppm (mg/l) as O 3 Maximum Cable Length: 300 ft (91 m) Sample Flow: Flow through Open channel Low flow cell 1 to 5 gpm (3.8 to 19 L/min) 1 ft/sec (0.3 m/sec) 8 to 15 gph (30 to 57 L/hr) Flow through Open channel Low flow cell 1 to 5 gpm (3.8 to 19 L/min) 1 ft/sec (0.3 m/sec) 2 to 5 gph (7.6 to 19 L/hr) 1 Viton is a registered trademark of E.I. dupont de Nemours & Co. 2 Teflon is a registered trademark of E.I. dupont de Nemours & Co. 2 Rosemount Analytical

FLOW CELL SPECIFICATIONS LOW FLOW CELL PN 23728-00 Wetted Parts: acrylic, CPVC, 316 stainless steel, Buna N; body is acrylic Process Connection: 1-1/2 inch socket Maximum Pressure: 65 psig (549 kpa) Maximum Temperature: 122 F ( 50 C) VALVED ROTAMETER PN 9390004 for use with Flow Cell Flow: 0.4 to 5 gph (1.5 to 19 L/hr) Wetted Parts: acrylic, 316 stainless steel, Viton Process Connection: 1/4 inch NFPT (316 SS) Maximum Pressure: 100 psig (858 kpa) Maximum Temperature: 150 F (65 C) VALVED ROTAMETER PN 196-898754 for use with Flow Cell Flow: 2 to 20 gph (7.6 to 76 L/hr) Wetted Parts: polycarbonate, 316 stainless steel, brass, Buna N Process Connection: 1/8 inch NFPT (brass) Maximum Pressure: 100 psig (858 kpa) Maximum Temperature: 130 F (54 C) FLOW-THROUGH TEE (1-1/2 inch body) PN 23567-00 Wetted Parts: CPVC and Buna N; body is schedule 80 CPVC Process Connection: 1-1/2 inch socket Maximum Pressure: 65 psig (549 kpa) Maximum Temperature: 122 F ( 50 C) FLOW-THROUGH TEE (2 inch body) PN 915240-03, 04, 05 Wetted Parts: PVC and Buna N; body is schedule 80 PVC Process Connection: 3/4 inch NFPT, 1 inch NFPT, or 1-1/2 inch NFPT Maximum Pressure: 60 psig (515 kpa) Maximum Temperature: 120 F (49 C) ANALYZER COMPATIBILITY WITH THE MODEL 499A SENSORS 499A CL 499A DO 499A OZ 1054 SERIES ANALYZERS X X X DELTA ANALYZERS 924 910 940 5310 82/8324 82/8310 82/8340 499A REPLACES 499TFC 499DO 499OZ Delta Delta Delta 921243 921103 921403 Delta 921243H Rosemount Analytical 3

MILLIMETER MILLIMETER 499A SENSOR Low Flow Cell Assembly Sensor Handrail Mounting Assembly MILLIMETER MILLIMETER Flow-Through Mounting Sensor Dimensions 4 Rosemount Analytical

ORDERING INFORMATION Model 499A Amperometric Sensors are designed for use with Rosemount Analytical Model 1054A and 1054B amperometric analyzers and with the Delta line of amperometric instruments (see compatibility table on page 3 for details). The sensor has upper and lower 1-inch MNPT threads for process connection. The sensor can be inserted or immersed in the process stream, or if a continuous sample is available, the sensor can be mounted in a variety of flow cells. The standard cable length is 25 ft (7.6 m). The pressure equalizing bladder and the integral temperature sensor for membrane permeability corrections are standard. Three replacement membrane assemblies, three O-ring seals, and a 4-oz (125 ml) bottle of electrolyte solution are provided with each sensor. MODELS 499 A AMPEROMETRIC SENSORS with 25ft. CABLE CODE DESCRIPTION (required selection) 499A DO Dissolved Oxygen Sensor 499A OZ Dissolved Ozone Sensor 499A CL-01 Free Residual Chlorine Sensor CODE ANALYZER COMPATIBILITY (required selection) 54 Sensor is compatible with Models 1054A and 1054B analyzers 56* Sensor is compatible with Delta analyzers (see table on page 3) CODE OPTIONAL OPTIONS 60 Optimum EMI/RFI Cable (not available with Option 56) 499 ACL -01-54 EXAMPLE * For first time replacement of Delta sensors: When replacing a Delta sensor (PN 921103 for oxygen, PN 921403 for ozone or PN 921243 for free chlorine), a retrofit adapter must be ordered. Use PN 33211-00 to adapt the 499A 1-inch MNPT to the Delta 1-1/2 inch FNPT flow-through tee. Use PN 33530-00 to adapt to the Delta handrail mounting. Rosemount Analytical 5

ACCESSORIES PART # DESCRIPTION 23567-00 1-1/2 in. flow thru tee, 1-1/2 in. straight flow cell with 1 in. NPT adapter 915240-03 2 in. PVC flow thru tee, 3/4 in. NPT process connection 915240-04 2 in. PVC flow thru tee, 1 in. NPT process connection 915240-05 2 in. PVC flow thru tee, 1-1/2 in. NPT process connection 33211-00 Retrofit adapter for Delta flow-through tees (tees have PNs 915240-00, -01, and -02) 33530-00 Retrofit adapter for 1 in. MNPT sensor to fit into Delta Handrail Mounting Assembly PN 11275-00 23728-00 Low Flow cell, Acrylic 9390004 Rotameter: 0.5-5.0 GPH 196-898754 Rotameter: 2.0-20.0 GPH 11275-01 Sensor Handrail Mounting Assembly: includes 10ft. (3.0m) Schedule 80 1-1/2 in. PVC pipe with sweep-ell 22719-02 Weatherproof junction box, NEMA 4X 2001492 Stainless Steel tag (specify marking) 9200266 Extension cable for 1054A and 1054B analyzer compatibility (specify length) ED0011 Extension cable for Delta analyzer compatibility (specify length) 9200275 Extension cable for optimum EMI/RFI cable (specify length) The right people, the right answers, right now. UNILOC DIVISION CUSTOMER SUPPORT CENTE 1-800-854-8257 ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.rauniloc.com Credit Cards for U.S. Purchases Only. Rosemount Analytical Inc. Uniloc Division 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 863-1181 http://www.rauniloc.com Rosemount Analytical Inc. 1998