Controller family Instat 7 INSTAT 7. Air Conditioning Controls

Similar documents
T5000 T000 LCD Digital Fan Coil Thermostat

york air-conditioning products Residential & VRF News 2015

Failure code manual. content

Controls for fan coil units and cassettes

T-100-R Installation Guide

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

REMOTE CONTROL MANUAL

INSTALLATION OPERATING & MAINTENANCE MANUAL

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

CGC s Hybrid System Loop Control

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Air Top 3500/ Circuit Diagrams

Split units TH with hermetic compressors

SWIMMING POOL HEAT PUMP Owners Manual

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Features and Benefits

HCE80/HCC80/HCE80R/HCC80R

Operating Instructions Split System Air Conditioner

STERILIZERS, LABORATORY DRYING OVENS


DUCT TYPE AIR CONDITIONER

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Commercial Refrigeration Temperature and Defrost Controls

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Hot Water. Heat pump water heaters. Residential and Commercial R410a

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

HERZ-Thermal Actuators

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

PANASONIC TROUBLE SHOOTING GUIDE

*.ppt 11/2/ :48 PM 1

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

MP-4000 Alarm List (Software version or later)

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil

User manual. 086U6297 Rev. 9 EN

General Information. Do programmable thermostats really save energy?

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

Aerona Air Source Heat Pumps

RF 1. Contents: Connecting diagram. Detailed information:

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Split Controller. User Manual SM-SS-F 2009/01/04

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Mode Switch. Fan Switch Menu button Program button

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Inwall Room Temperature Unit

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

Technical Support Bulletin Nr. 20 Special AC Functions

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Flush-mounted room thermostats

Variable Air Volume - VAV

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

PROCEDURES FOR SELF DIAGNOSTICS

Wiring Diagram. Diplomat 400V 3N.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Operating Instructions Air Conditioner

Building Technologies. Thermostats and room controllers. General Product range overview Thermostats

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Air-conditioning controller. User's Manual NRT 107 F031, F R R2 Sauter Components

HP switch LP switch Discharge thermo Comp. Surface thermo

Condensing Boiler Efficiency

User manual. Atec. 086L0130 Rev. 1 EN

KONRAD. Hybrid Fancoil Series

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Technical service manual 2009

Transcription:

K Controller family Instat 7 INSTAT 7 Air Conditioning Controls

Air conditioning controller INSTAT 7 Applications The electronic AC controller INSTAT 7 can be used to control: -pipe / 4-pipe fan coils Heat-pumps in air-conditioning units (with/without reverse valve) Split units Cooling equipment with/without electrical heating etc. Common features of the INSTAT 7 family -point controller with feedback Clear LCD display Permanent display of room temperature, set temperature at touch of a button Operating elements: 4 buttons (Mode, +,, OK) Menu-assisted operation Max. 5 relays - outputs Stand-by Separate heating, cooling User-defined dead zone and stage gap Fan control manual in speeds (according to model) Automatic fan (fan operates during heating and cooling, fan speeds depending on the temperature difference) (according to model) Fan off delay (if heating switches off) Compressor/restart delay following mains failure, during normal operation and during function/operating mode switch-over Automatic change over between internal and external room temperature sensors Safe data in case of power failure Automatic ventilation Fan speed 1 Fan speed Fan speed Timer Heating only 1 g h i Cooling only Fan only U P f 1 Automatic heating/cooling W X ON timer OFF timer Air-sweep Stand-by Curser to symbols : P U Temperature Heating active Cooling active U P

Optional features (these features are only available in certain controller models, see table of variants page 5) Automatic change over between heating and cooling x heating and x cooling (user-defined stage gaps) Output for reverse valve Defrost function Electric auxiliary heater (for heat-pumps) External-temperature control management in cooling operation Remote sensor input Window contact input Air Sweep On/Off ON timer, OFF timer (set time range : 10 min. to 99 h 50 min.) Master/Slave function (slaves switch off when the master is in the dead zone) Hotel version (easy setting) On/Off switch (single pole disconnected of the equipment from power supply) AC 0 or AC 4 variants Common technical data Model no. INSTAT 7 EDP No. 57 1... 60... Temperature range 15... 0 0.5 K 0 C are pre-set Temperature display 0 to 40 0.1 K Operating temperature 0 to 40 C Control algorithm Two-position with feedback Display: LCD-Display with simultaneous display of room temperature, timer, operating mode Display size 41 x 4 mm (l x h) Figure size 1 mm for temperature 9 mm for timer static hysteresis for heating/fan approx. 1.1 K for cooling/fan approx. 1. K Relay output max. two L-connections Fan relays voltage free Protection class IP 40 Dimensions 14 x 71 x mm (h x w x d) Specific technical data Power supply AC 0 (195... 5 ) 50 Hz UC 4 (0... 7 ) Temp. sensor external NT Type F 19 70 according to variant none, 1 or sensors possible Length 4 m, extensions to 10 m possible Timer: 10 min. to 99 hours 50 min. Window contact Extension to 100 m possible Dead zone H1-C1 0... 5 K (1.5 K pre-set) adjustable in 0.5 K steps Stage gap H1-H 0... 5 K (1.5 K pre-set) C1-C adjustable in 0.5 K steps Fan off delay approx. 1 minute Compressor-/restart delay approx. 4 minutes Outputs: Max. 5 relays AC 50 5 A cos ϕ =1 according to variant A cos ϕ =0.6 Max. capacity per < 10 A L-connection

Applications 4-pipe fan coil -pipe fan coil heat-pump

Matrix of variants INSTAT 7 Relay outputs Sensor Inputs Functions Heating Cooling Compressor Reverse valve Fan speeds Air sweep Outdoor fan Aux. heating Master Room Defrost Outdoor Window-contact /Slave Heating/cooling c/o input Hotel version ON/OFF timer Only manual c/o heating/ cooling Cooling only/ fan only ON/OFF switch Order -No.: 05759 05758 05757 05756 05755 05754 0575 0575 05751 05750 05760 05749 05748 05747 05746 05745 05744 0574 0574 05741 05740 0579 0578 0577 0576 0575 0574 057 057 0571 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 α O P T I O N A L Applications Heatpump -pipe fan coils -pipe fan coils -pipe fan coils x heating x cooling cooling only cooling only 4-pipe fan coils Used Symbols Automatic c Fan speeds f Heating U Cooling P Fan only f ON/OFF-timer > 1 1 1 1 1 1 Air sweep X = Standard variants α = Auxiliary heating for heating- and cooling mode H = Heating, C = Cooling, = entilation

FAXINFO INSTAT 7 We have the following technical problem and would like your suggestions: Please copy and send to: EBERLE Infoline +49 911/ 56 9-14 Please call us: Mrs./Mr. Telephone Telefax EBERLE Controls GmbH Postfach 1 01 5 D-9011 Nürnberg Klingenhofstraße 71 D-90411 Nürnberg Telephone +49 9 11 / 56 9-0 Telefax +49 9 11 / 56 9-14 EBERLE Controls GmbH Postfach 1 01 5 D-9011 Nürnberg Klingenhofstraße 71 D-90411 Nürnberg T +49(0)911 56 9 0 F +49(0)911 56 9 56 EMail: infoeberle@invensysclimate.com U 468 9100 671-C -10.99 Errors possible / Subject to alterations