We have the experience



Similar documents
Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

About us. Eugensa is an ISO 9001:2008 certified company. CERT

North Street, Stoke-on-Trent, ST4 7SA. Tel: Fax: Web:

Datacentre Capability March 2015

Commercial Heating and Ventilation

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

CONTENTS ABOUT US SALES OVERVIEW SALES PRODUCTS OTHER SERVICES OUR LOCATIONS ACCREDITATIONS RECENT PROJECTS 12 CASE STUDIES 13

EXAMPLE OF A DATA CENTRE BUILD

Data Centres A complete solution to noise control and acoustic packages

Engineered Solutions

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

The kva RAnge

JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES

Session 14 Cable Support Systems

Diesel Engine Driven Generators Page 1 of 6

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

ASX Australian Liquidity Centre. ASXCoLo

RPV - RP - RA air handling units

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

B-1 Buildings & Service Maintenance

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Fact sheet 6: for farmers

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Capgemini UK Infrastructure Outsourcing

Standard Comms Rooms Specification

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

Product description NCC Data Center

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Heating and Hot Water Services Controls General Technical Specification

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

CFD Beyond the Whitespace. Datacentres Central & Eastern Europe

Project Management And Installations

E. Fowler & Sons Ltd.

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

Fact sheet 6: for farmers

heat treatment equipment & accessories

COOKING THE ROOF CFD BEYOND THE WHITE SPACE

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

Addendum #2 Contract UK-11-13

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Rental Cooling Plant Design & Energy Performance. Presented by: Lee Cox Rental Solutions & Services IDEA Conference 2009

Atlas Copco Generators

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

Environmental Management System Procedures

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

COMMISSIONING OF HVAC SYSTEMS

Drives and motors. A guide to using variable-speed drives and motors in data centres

ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1

WHAT IS INFRARED (IR) THERMOGRAPHY

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Crawford Inspection Services C.C.B. #

Industrial Generator Set Accessories

Data Centre Services. JT Rue Des Pres Data Centre Facility Product Description

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

Apartment and Communal Heating Solutions

SECTION GENERAL PROVISIONS FOR HVAC WORK

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

RELAX IT DOES THE REST GUEST ROOM CONTROL SYSTEM FOR HOSPITALITY BUILDINGS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

The vision of the Ham Baker Group is to be the partner of

Electrical Contractors Association

FAIRBANKS NIJHUIS FIRE PUMPS.

Nominal Life Expectancy for Building Components

INTRODUCTION INDUSTRIAL INSTALLATIONS AND ERECTIONS QUALITY THAT EXCELS

Oil and Coolant Circulating Heating System. Model - OCSM

DATACENTER COLOCATION. Flexible, Secure and Connected

A guide to connecting to fibre optic networks for homeowners, architects, builders and developers.

TMS TANK MANAGEMENT SYSTEM

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Building Services Engineering Technician

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

Data Centre Testing and Commissioning

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Annex-A TECHNICAL SPECIFICATION

CIBSE Guide M: Maintenance engineering and management Statutory compliance legislation and guidance

Previder Datacenters it starts here

building engineering services association specification for: Domestic Heating

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

OIL & GAS EQUIPMENT RENTAL SOLUTIONS. byrnerental.com

Commercial Property Tenants Your rights and responsibilities

ECOCIAT. Domestic hot water heat recovery unit

PUMPSTOR COMPLETE WASTE WATER AND SURFACE WATER PUMPING SOLUTIONS

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Cooking at the Speed of light!

Specifying an IT Cabling System

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

Sump Systems for Basements

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

South Datacentre Studley

Element D Services Plumbing

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Example Specialist Other contact

Transcription:

We have the experience EST. 1977 Worldwide Generator, Electrical & Mechanical Installation Contractors

1 Aidan Strain has been in business since 1977, initially as commercial, industrial and domestic electrical contractors working throughout the UK and Ireland. In 1993 an electrical wholesale outlet was established on the premises and remains a well known and established business serving local contractors, businesses and factories. In 1995 the range of contracting activities was broadened to include mechanical engineering as the business continued to expand in the UK and Europe. These individual enterprises were amalgamated to form ASEE Ltd. in 2000 and since then that company has maintained a considerable presence in the UK and Europe, both as generator installers and in delivering Mechanical and Electrical contracts which include:- Hospitals Telecommunications facilities Data centres Factories Water treatment plants Office and residential complexes Maintenance and building management services Minor building works

2 Worldwide Generator, Electrical and Mechanical Installation Contractors The company centres on a nucleus of 45 staff with additional resources employed as necessary to service particular project requirements many of which have peaked at around 160 personnel throughout the years. The engineering company has satellite offices in London and Germany, whilst still maintaining its head office base outside Newry, Northern Ireland. We recognise the importance of being adaptable to the needs of our clients. We are a privately owned company and our independent status means we are not part of a group or holding company that could restrict our participation. We have the experience

3 Projects Skondal Data Centre Stockholm, Sweden. Berkshire Data Centre Berkshire, UK ASEE has demonstrated competence in the delivery of a wide range of services, over many projects, in line with programmes and budgets to meet the various needs of our clients, as illustrated here. New Change St Pauls, Central London, UK Scope: Installation of 2 x 2.0 MVA and 2 x 750 kva generators on roof of building, installation of 4 bulk tanks in basement & associated fuel transfer pipe work. Installation of the associated generator control systems. Scope: Installation of a fully welded fuel system with over spill line and 2 x 13,000L double skinned above ground bulk storage tanks with leak detection provided. ASEE also provided and installed a dual pump system housed in a stand alone kiosk, suitable for external temperatures of -20 degc. All interconnecting control cabling between the fuel system and the generators was also included in our scope. Scope: Installation of 6 x 3.0 MVA generators complete with all associated fuel tanks and transfer pipe work. 2 x 80,000L double skinned above ground bulk storage tanks, manufactured to BS799 Part 5, with fuel polishing facilities and leak detection provided. 6 x 4000L double skinned generator day tanks, manufactured to BS799 Part 5, with leak detection provided. 2 x bunded pump kiosks with duty/standby pumps, fuel control panel and leak detection. We installed a double skinned fully welded fuel transfer system with leak detection monitoring. 2 x roller shutter door fill points complete with fuel meters, high level alarm units and fuel capacity gauges. We installed a fully welded water cooling system for 6 generators extending to flow/return/fill/vent lines for the engine jacket and flow/return/fill/vent lines for the after cooler from each generator to the remote radiators. All welds were subject to 10% None Destructive Testing (NDT). We also installed all associated generator control cables, attenuation and exhausts/flues. Hyde Park Corner Knightsbridge, Central London, UK Surrey Data Centre Surrey, UK Canary Wharf Data Centre London, UK. Scope: Installation of 2 x 1650 kva back up power generators in basement complete with fuel transfer pipe work, attenuation, acoustic walls and associated electrical work. Scope: Full electrical installation of multiple large data halls from 1000msq to 3000msq. Our scope included the installation of all HV, LV, Busbar, Containment, Lighting, Small Power, Generators control cables and BMS installation. Scope: Installation of 3 x 2.0 MVA roof mounted containerised generators, including fuel transfer pipe work and installation of all associated generator control cables.

4 Northern Data Centre Wynyard, Stockton-on-Tees, UK BBC Portland Place Regent Street, London, UK Hertfordshire Data Centre Welwyn Garden City Scope: Installation of 10 x 2.3 MVA HV Generator sets, associated HV switchgear and 380,000 L bulk fuel storage tanks manufactured to EN12285. (All storage tanks underground) Scope: Installation of 3 x 3.75 MVA generators in basement over 2 phases. Site construct 103,000 L double skin fuel tank in basement. Installation of roof mounted cooling radiators. Installation of c500m cooling pipe work over 12 levels between the roof & basement. Hampshire Data Centre Portsmouth, Hampshire, UK Schipol Data Centre, Amsterdam Schipol, Amsterdam, Netherlands Scope: Removal of existing services and replacement chiller installation. We also carried out the installation of new high level cable containment system and replaced chiller supply cables. Scope: Full electrical installation of 1 large 3,000msq data hall. Our scope included installation of all HV, LV, busbar, containment, lighting, small power, generator control cables, BMS / EMS, fire alarm, leak detection, UPS cabling, earthing and lighting protection. 2 x 130,000 L double skinned below ground bulk storage tanks, manufactured to EN12285-1 with leak detection provided. 2 x pump skids comprising of a duty/standby system. Installed a below ground plastic pipe in pipe fuel system with leak detection monitoring. 2 x fill points complete high level alarm units and fuel capacity gauges. Gutersloh Data Centre Gutersloh, Germany Gibraltar Data Centre Gibraltar, UK Amsterdam Data Centre Overamstel, Amsterdam, Netherlands Scope: Installation of 3 x 500 kva containerised generators, associated fuel pipe work and generator control cables. Scope: Installation of 2 x containerised 500kVA generators, a double skinned fully welded fuel balancing system with leak detection monitoring and 1 x fill cabinet with high level alarm unit. We also installed all associated generator control cables. Scope: Full electrical installation of 1 No. 1,000msq data hall. Installation of all HV, LV, busbar, containment, lighting, small power, generators control cables and BMS installation.

5 Electrical Installations At Aidan Strain Electrical Engineering Ltd. we provide a wide range of electrical services including: HV installations LV installations Generator installations Cable containment systems Lighting & small power IT, data, fibre & BMS installations Testing Data centre fit-out & facility management Electrical Projects With our dedicated team of electrical engineers on hand to meet your needs, we have the experience to deliver any electrical project, from MV mains incomer to LV final circuit, that both our client and ASEE can be proud of. Electrical features include specification and design / build for a range of electrical installation services. Switch Gear & UPS Installations ASEE carry out a full installation service on HV & LV Switch Gear as well as battery and UPS systems including control and intertrip signalling. For plant movement, final positioning & cable installation we have the experience. Busbar Installations We provide a full busbar installation service, offering input into the design phase, delivery & installation covering the full range from 25 Amp lighting busbar to 4000 Amp distribution busbar. This is complemented with full system testing & commissioning ready for client hand over. Our installation teams are trained & certified in busbar installation and have installed thousands of metres of LV busbar over various data centre projects. HV Installations ASEE has been carrying out HV Installations since 1990's. Our personnel are competent and certified to install, gland, switch, test & commission up to 11 Kv. We provide the following HV services :- Appointed person for your installation, design, supply and installation, including feasibility studies. Control and operation of HV and LV networks. Plant and apparatus refurbishment or replacement. Cable jointing and underground distribution systems. Fault location and fault level studies. Inspection, operation and maintenance. Protection and earthing studies. Testing, certification and commissioning. Cable Containment Systems ASEE install all types and sizes of cable containment such as cable tray and cable ladder equipment. We offer a design and consultation service in order to specify the right product for each project including standard galvanized finishes, PVC, GRP, basket and stainless steel cable ladders and trays. Lighting ASEE has been installing lighting systems for over 30 years. From internal lighting tracks to external lighting we have the expertise. We also has the capability to determine your lighting requirements during the design stage of a project. Cable Installations We are established cable installation contractors with a wealth of experience throughout the electrical industry. We carry out cable installations on a wide range of projects. Whatever your requirements are we can assure you that the works will be delivered to the highest standards in full compliance with all current health and safety / environmental legislation. All our staff have proven competencies in the relevant fields.

6 Small Power Installations ASEE design, supply and install small power systems including distribution boards, submain and final circuit cabling, socket outlets, fused connection units, isolators and other small power accessories. We have nearly 35 years experience in this sector & we have carried out installations on :- Data Centres Hospitals Large Scale Commercial & Industrial Developments Hotels Water & Sewage Treatment Plants Waste to Energy Plants IT, Data, Fibre & BMS / EMS Installations We supply & install instrumentation in industrial plant and process contexts, with particular reference to intrinsically safe work in hazardous environments and programmable logic controller (PLC) computer interfaces. ASEE provide data installation services including CAT 5E/6 cabling, patch panels, patch cabling, Data / Voice cabinets and active equipment such as switches, hubs, etc. We also offer full infrastructure cable testing. We supply and install fibre optic cabling with all splicing and termination options. Testing ASEE can provide electrical testing & certification on all works to the current standards as published, for example in the IEE wiring regulations, Irish ET101 and European Harmonised Standards. All our testing equipment is maintained to the highest standard and our testing teams have a wealth of knowledge & expertise. We also offer periodic testing inspections to satisfy statutory requirements for entire electrical installations, including petrol forecourts. Data Centre Fit-Out & Facility Management We currently manage a number of data centre facilities in the Greater London area. Our Facilities Management teams work closely with client needs to effect day to day alterations and additions to server cabinets and data racks as well as ongoing maintenance to existing equipment. Our data centre fit out teams draw from a wide base of experience amassed in developing data centres across the UK & Europe and are well placed to develop and adapt your data centre based on your client needs. We also offer OTDR (Optical Time Domain Reflectometer) and power-loss measurement testing for optical networks. We carry out full BMS / EMS installations and undertake all specialist cable containment requirements.

7 Mechanical Installations At ASEE we provide a wide range of mechanical services including: Plant Movement 2D & 3D CAD Design Drawings Fuel Tank Fabrication & or Installation Fuel Pipe Work Fabrication Steel Support and Bracketry Fabrication Air Intake & Discharge Exhaust Silencers Flues Ventilation & Ductwork Attenuation & Acoustics Air Start Systems Cooling Systems Mechanical Testing Maintenance Response Mechanical Projects With our dedicated team of mechanical engineers on hand to meet your needs, we have the experience to deliver a mechanical project that both you as the client and we can be proud of. Mechanical features include specification, CAD design and on-site construction of bunker and day fuel storage tanks, twin wall leak monitored pipeline construction, exhaust silencer, flue and acoustic attenuation construction. Plant Movement Our organisation comprises of dedicated highly trained plant movement teams in place to ensure the safe delivery of any size of plant and equipment. We have been providing plant movement services on our generator installation projects for over 20 years, from complex city centre lifts to stand alone simplistic lifts, we have the experience to look after your needs. Fuel Tank Fabrication & Installation ASEE supply & install bespoke tanks, primarily for the bulk storage of fuel. We design, manufacture, install and commission our own tanks. All tanks are constructed to the appropriate BS or EN standard, for example BS 799 Type J or K for rectangular double skin tanks or cylindrical tanks generally to EN 12285-1 made from steel plate to BS EN 10025:2004:S275. Tanks can be built off site & lifted into final position, or where necessary we can carry out a safe compliant site build installation. With over 20 years in this sector we have the knowledge and experience to deliver a product that will meet all regulations, providing that peace of mind. Fuel Pipe Work Fabrication ASEE design, manufacture, install, test and commission bespoke fuel transfer pipe work to suit your needs. With the ability to manufacture bulk pipe deliveries off site and carry out bespoke on site installations, we have the experience to deliver a sound and safe pipe transfer system. All fabrications and installations are carried out in line with all relevant standards and regulations. We also offer plastic pipe in pipe systems for underground fuel transfer with leak detection monitoring fitted as standard. Steel Support and Bracketry Fabrication From basic bracketry to complex structural steel systems, we have the experience. We have been manufacturing & installing steel frame support systems for over 15 years. Flues & Exhaust Systems ASEE design, fabricate, install and commission bespoke and modular flue and exhaust systems to suit your needs. We provide all required certified performance data to EN 13384-1 and all installations are carried out in line with ISO 9001:2000. Our installations are tested and certified to BS EN 1836-1 and generally to BS EN 1443.

8 Ventilation & Attenuation Ventilation and attenuation can be designed, installed and tested based on the clients needs. With noise pollution becoming a greater issue, we understand your needs to maintain controlled noise levels. We work in conjunction with local authorities and industry specialists to ensure compliance is achieved for external db readings. Air Start Systems Our typical air start system comprises of electric DC driven compressors, air starting motor, air receiver, safety pressure valves connected up with schedule 80 pipe & fittings. We have been installing air start systems for over 20 years. Cooling Systems Mechanical Testing Where required to carry out mechanical testing ASEE undertake to provide the following mechanical testing services prior to handing a project back to the client. Hydraulic & pneumatic testing & certification of all fluid transfer pipe work, such as cooling circuits, fuel transfer pipe work and any other process pipe work. Pneumatic testing & certification of bulk storage tanks, such as bulk fuel storage tanks. Pressure testing of flue and attenuation systems. Weld testing on mechanical transfer pipe work & storage tanks. Diesel quality testing. Fuel system integrity inspection. Mechanical installation and testing is carried out in accordance with BS 5410-2 and in compliance with DEFRA. Painting and identification is carried out in accordance to BS 1710.. ASEE install remote cooling systems complete with interconnecting pipework. We also install heat exchanger units, cooling pumps, secondary & primary cooling circuits, all ancillary valves, gauging, testing and commissioning. This is followed up with dedicated test records and certificates including pneumatic and hydraulic water flushing samples. Maintenance Response Team Our Maintenance response teams are available throughout the UK to respond to your needs. We maintain a fleet and fully serviced vans to provide a rapid response throughout the UK

9 Generator Installations Aidan Strain Electrical Engineering has been carrying out generator installations throughout Europe since 1990. We offer a full bespoke installation package with a range of mechanical and electrical services which include:- Bulk fuel storage tanks and fuel systems (on site or off site build) Exhaust & silencer systems Attenuation systems Flue systems Air start systems Radiator / coolant systems Air handling & plant UPS installation Transformer installations Neutral earthing and resistive earthing systems Generator control systems Generator load testing Generator / mains synchronisation - G59 etc.

Multiple Generator HV Switchgear Installation Data Centre Heat Load Testing Generator Flue Installation Plant Movement Generator Attenuation

NORTHERN IRELAND OFFICE 40 Maphoner Road Mullaghbawn Newry Co. Down BT35 9TR Tel: +44 (0) 2830 888861 Fax: +44 (0) 2830 888862 Email: info@aseeltd.com ENGLISH OFFICE Norbury London SW16 4AB Tel: +44 (0) 20 77650060 Fax: +44 (0) 20 76365542 Email: englishoffice@aseeltd.com GERMAN OFFICE Wallerfanger Str. 24 66793 Saarwellingen Email: germanoffice@aseeltd.com www.aseeltd.com