EWA. Ex d Painted aluminium body

Similar documents
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Compact pressure switch Flameproof enclosure Ex d Model PCA

Explosion proof enclosures

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Terminal Boxes Series 8146

Terminal Box. Specifications TNCN

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Instructions for Safe Use

Series 8146/5-V37 and Series 8150/5-V37

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

SEISMIC VELOCITY TRANSDUCER T1-40

Plug and Socket Devices CES 63 A Series 8579

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

2.12. page Products for Explosion hazardous Environment

Floodlight Range Installation Guide

DuroSite TM High Bay Lighting

Flameproof Audible Signal 115 db (A) Series YA90

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

Abtech Custom Solutions

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Plug and Socket Devices SolConeX 16 A Series 8570

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

8146/5 Series Breaker Panelboards

Scraper Passage Indicator. Electrical Indicator. Features

Guide to enclosures for potentially explosive atmospheres

David O Brien, CMP Products (David.OBrien@cmp-products.com)

Operating Instructions

Industrial Luminaires

Technical Data. Dimensions

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Safety instructions VEGADIS DIS81.CEIA/V****

A good connection. International approvals.

Technical Specifications

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

Control and Distribution Boxes made of Stainless Steel Series 8150

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

Technical data sheet TDS0070

Threaded Resistance Thermometers Model TR10-D, Miniature Design

TEIP11 I/P signal converter for standard signals. Measurement made easy

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

distributing & controlling system solutions

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

EX-PROOF PTZ DAY/NIGHT CAMERA FOR HIGHLY CORROSIVE ENVIRONMENTS MPX

400 Series - Mini USB Buccaneer

Operating Instructions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Nightscape High performance floodlights and spotlights for discharge lamps

7000 Series Buccaneer

Nightspot High performance floodlights for discharge lamps and LEDs

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

STB Series Enclosures

Electric Rotary Actuator - On/Off or programmable control actuator

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Explosion-Proof Electric Unit Heaters

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Worcester DS/DM Series UltraSwitch Switch box

Technical Data. Dimensions

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

3/2-way Solenoid Valve, direct-acting, NC or NO

Inductive sensor NI10-M18-Y1X-H1141

IPS HIGH-BAY / LOW-BAY LIGHTING

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

Solenoid Valve Island Type 3965

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Technical Information RIA14

Dialight LED Lighting Fixture Catalog. for Industrial and Hazardous Locations

Flow switches Series AD/VH

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Transformer oil cooler ALFA A02

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Superlight Compact Nano

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

RUBBER SLEEVE KNIFE GATE VALVE

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Fluxa Area floodlights for high pressure discharge lamps and LEDs

CRN A-F-G-E-HQQE 3x400D 50 HZ

Standard Buccaneer - USB

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

SITRANS F flowmeters SITRANS F M

CAPACITIVE LEVEL METERS CLM 36

Dialight LED Lighting Fixture Catalog. for Indoor and Outdoor Industrial and Hazardous Locations

Transcription:

Ex d Painted aluminium body EWA - Suitable for installation with ambient temperatures from -50 C to +60 C - Suitable for discharge lamps up to 400W - Zones 1, 2, 21, 22 4 Joule shock resistant borosilicate glass globe Electrical component housing Stainless steel protective guard A.24 ED.2017

EWA series Lighting fixtures for discharge lamps up to 400W Ex d EWA series of lighting fixtures for discharge lamps has been designed in compliance with ATEX Directive 2014/34/UE for all those areas defined as hazardous due to the presence of potentially explosive flammable gases and dusts where good local lighting is a necessity. The body of the lamp is made of low copper content aluminium alloy, the globe is made of borosilicate glass and has excellent thermal and mechanical properties. For this reason, the fixture can also be installed without a protective guard. The resistance of this lighting fixture to high (+60 C) and low (-50 C) temperatures makes it ideal for use in any type of climatic condition and it can be used in plants worldwide. As EWA series was designed with the Ex d protection method the entry to the fixture, as specified in the installation standard (EN/IEC 60079-14), must be only through an Ex barrier cable gland (sealed) or, in the case of a conduit system, with an EYS, EZS sealing fittings. Application sectors: CERTIFICATION DATA Oil refineries Chemical and petrochemical plants Onshore plants Offshore plants Low temperatures Fuel depots Fuel tanker loading/ unloading areas 100% Cortem product Classification: Group II Category 2GD Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Marking: II 2GD Ex d IIC T.. Gb - Ex tb IIIC T.. C Db IP66 Certification: ATEX CESI 12 ATEX 006 IEC Ex CES 07.0004 TR CU AVAILABLE All IEC Ex and TR CU certification data can be downloaded at www.cortemgroup.com Standards: CENELEC EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-7: 2007, EN 60079-31: 2009 and EUROPEAN DIRECTIVE 2014/34/UE IEC 60079-0: 2012, IEC 60079-1: 2007, IEC 60079-7: 2007, IEC 60079-31: 2009 Directiva Europea 2006/95 Baja tensión Directiva Europea 2004/108 Compatibilidad electromagnética Directiva Europea 2003/108 RAEE Reciclaje de Aparatos Eléctricos y Electrónicos Directiva Europea 2011/64 RoHS Class temperature: See selection chart Ambient temperature: Degree of protection: Standard -20 C +60 C Special -50 C +60 C (not possible for model EWA...100) IP66 ED.2017 A.25

Ex d EWA series Lighting fixtures for discharge lamps up to 400W MECHANICAL FEATURES Body: Globe: Gaskets: Guard: Mounting: Bolts and screws: Entries: Coating: ORIGINAL PRODUCT Low copper content aluminium alloy Complete with housing for electrical components Shock and high temperature resistant borosilicate glass with aluminium shade ring Silicone acid/hydrocarbon resistant Electro-polished stainless steel. Can also be supplied on request without a guard as the lighting fixture has passed the glass breakage test (4 Joule EN60079-0 / IEC60079-0) See EWA series dimensional drawings Stainless steel 3/4 NPT threads Epoxy coating Ral 7035 (Light grey) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot/humid cycles) and EN60068-2-11 (salt mist tests) ELECTRICAL FEATURES Lamp holder: E27 or E40 ceramic Ballast: Electromechanical Rated voltage: 230 V AC Rated frequency: 50 Hz Connection: Direct connection to the terminal box L, N, Pe. Section 4mm 2 Power factor: 0.96 Wiring: Silicone rubber cables with glass braid insulation for high temperatures ACCESSORIES AVAILABLE / SPECIAL REQUESTS Discharge lamp Different rated voltages Rated frequency: 60 Hz at 230 V (code EWA-50F5/60) External reflector Cable gland: FGAB2NBK for armoured cable or FB2NBK for non-armoured cable GAS UNI ISO 7/1 thread Bracket for pole mounting A.26 ED.2017

EWA series selection chart Ex d Code Dimensions mm Lamp Type Lamp holder Watt Class Max Surface Temp Weight A B C Ta =+60 C C Kg EWAT-50N2 610 220 235 Sodium vapour E 40 100 T4 132 10,6 240x240x660 mm EWAT-50N4 EWAT-50N5 EWAT-50100N6 EWAT-50IM2 EWAT-50IM4 EWAT-50IM5 EWAT-50100IM6 EWAT-50F5 EWAT-50100F6 610 220 235 Sodium vapour E 40 150 T4 132 11,4 240x240x660 610 220 235 Sodium vapour E 40 250 T3 159 12,7 240x240x660 677 2 265 Sodium vapour E 40 400 T3 164 17,1 2x2x850 610 220 235 Metal halide E 27 100 T4 130 10,3 240x240x660 610 220 235 Metal halide E 27 150 T4 130 11,1 240x240x660 610 220 235 Metal halide E 40 250 T3 1 12,7 240x240x660 677 2 265 Metal halide E 40 400 T3 163 15,5 2x2x850 610 220 235 Mercury vapour E 40 250 T3 148 10,8 240x240x660 677 2 265 Mercury vapour E 40 400 T3 177 15,5 2x2x850 EWAGC-50N2 EWAGC-50N4 EWAGC-50N5 EWAGC-50100N6 EWAGC-50IM2 EWAGC-50IM4 EWAGC-50IM5 EWAGC-50100IM6 EWAGC-50F5 EWAGC-50100F6 643 220 235 Sodium vapour E 40 100 T4 132 10,4 240x240x660 643 220 235 Sodium vapour E 40 150 T4 132 11,2 240x240x660 643 220 235 Sodium vapour E 40 250 T3 159 12,5 240x240x660 713 2 265 Sodium vapour E 40 400 T3 164 17,9 2x2x850 643 220 235 Metal halide E 27 100 T4 130 10,1 240x240x660 643 220 235 Metal halide E 27 150 T4 130 10,9 240x240x660 643 220 235 Metal halide E 40 250 T3 1 12,4 240x240x660 713 2 265 Metal halide E 40 400 T3 163 16,6 2x2x850 643 220 235 Mercury vapour E 40 250 T3 148 10,1 240x240x660 713 2 265 Mercury vapour E 40 400 T3 177 16,6 2x2x850 EWAT Pendant mounting EWAGC Pendant mounting with eyebolt ED.2017 A.27

Ex d EWA series selection chart Code Dimensions mm Lamp Type Lamp holder Watt Class Max Surface Temp Weight A B C Ta =+60 C C Kg EWAIX-50N2 592 500 235 Sodium vapour E 40 100 T4 132 10,7 2x2x850 mm EWAIX-50N4 EWAIX-50N5 EWAIX-50100N6 EWAIX-50IM2 EWAIX-50IM4 EWAIX-50IM5 EWAIX-50100IM6 EWAIX-50F5 EWAIX-50100F6 592 500 235 Sodium vapour E 40 150 T4 132 11,5 2x2x850 592 500 235 Sodium vapour E 40 250 T3 159 12,8 2x2x850 650 547 265 Sodium vapour E 40 400 T3 164 15,4 2x2x850 592 500 235 Metal halide E 27 100 T4 130 10,4 2x2x850 592 500 235 Metal halide E 27 150 T4 130 11,2 2x2x850 592 500 235 Metal halide E 40 250 T3 1 12,7 2x2x850 650 547 265 Metal halide E 40 400 T3 163 14,1 2x2x850 592 500 235 Mercury vapour E 40 250 T3 148 11,4 2x2x850 650 547 265 Mercury vapour E 40 400 T3 177 17,0 2x2x850 EWAX-50N2 EWAX-50N4 EWAX-50N5 EWAX-50100N6 EWAX-50IM2 EWAX-50IM4 EWAX-50IM5 EWAX-50100IM6 EWAX-50F5 EWAX-50100F6 610 220 235 Sodium vapour E 40 100 T4 132 10,6 240x240x660 610 220 235 Sodium vapour E 40 150 T4 132 11,4 240x240x660 610 220 235 Sodium vapour E 40 250 T3 159 12,7 240x240x660 677 2 265 Sodium vapour E 40 400 T3 164 16,2 2x2x850 610 220 235 Metal halide E 27 100 T4 130 10,3 240x240x660 610 220 235 Metal halide E 27 150 T4 130 11,1 240x240x660 610 220 235 Metal halide E 40 250 T3 1 12,7 240x240x660 677 2 265 Metal halide E 40 400 T3 163 16,0 2x2x850 610 220 235 Mercury vapour E 40 250 T3 148 11,4 240x240x660 677 2 265 Mercury vapour E 40 400 T3 177 15,9 2x2x850 EWAIX Wall mounting with 30 bracket EWAX Ceiling mounting Dimensions in mm A.28 ED.2017

EWA series Accessories and spare parts available on request Ex d ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY 100 W (SE100W) LAMPNAV100WPLUS High pressure sodium vapour lamp E40 150 W (SE150W) LAMPNAV150WPLUS 250 W (SE250W) LAMPNAV250WPLUS 400 W (SE400W) LAMPNAV400WPLUS Mercury vapour lamp E40 250 W (QE250W) LAMP250WHQL 400 W (QE400W) LAMP400WHQL Metal halide lamp E27 E40 100 W (ME100W) LAMP100WJM 150 W (ME150W) LAMP150WJM 250 W (ME250W) LAMP250WJM 400 W (ME400W) LAMP400WJM Cable gland For models and codes, visit www.cortemgroup.com FB2NBK FGAB2NBK Reflector 100 White painted aluminium Stainless steel White painted aluminium Stainless steel G-427 G-427IN G100-427 G100-427IN White painted aluminium G-427D Dome reflector 100 White painted aluminium G100-427D White painted aluminium G-427DI 30 inclined dome reflector 100 Contact our Sales Office for availability 100 1 1/4 pole G4-0541 G4-0542 Galvanised steel brackets for pole mounting (see installation and mounting methods) 100 100 1 1/2 pole 2 pole G5-0541 G5-0542 G6-0541 G6-0542 100 2 1/2 pole G7-0541 G7-0542 ED.2017 A.29

Ex d EWA series Accessories and spare parts available on request ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY O-ring Globo Globo 100 Material: silicone K34-131S K27-131S Ballast for mercury vapour lamp 250 W R-250 400 W R-400 100 W R-100NA Ballast for sodium vapour and metal halide lamps 150 W R-150NA 250 W R-250NA 400 W (sodium) R-400NA 400 W (halide) R-400 Metal capacitor Ceramic lamp holder 50N2 16μF 250V F-16 50N4 20μF 250V F-20 50N5 35μF 250V F-35 50100N6 50μF 250V F-50 50IM2 12,5μF 250V F-12,5 50IM4 20μF 250V F-20 50IM5 30μF 250V F-30 50100IM6 40μF 250V F-40 50F5 20μF 250V F-20 50100F6 25μF 250V F-400 E27 250V 4A PORT E-27 E40 750V 16A PORT E-40 Igniter 50-400 W R100 Globe with shade ring G-0440CM Borosilicate glass globe Threaded aluminium shade ring 100 G100-0440CM Protective guard G-0417 Material: electro-polished stainless steel 100 G100-0417 A.30 ED.2017

EWA series Accessories and spare parts available on request Ex d ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY Pendant eyebolt In galvanised steel GOF-8 Pendant mounting EWA 1 x 3/4 entry G-0213 Pendant mounting with eyebolt EWAGC 4 x 3/4 entries G-0216 Ceiling mounting EWAX 4 x 3/4 entries G-0214 Wall mountings with bracket EWAIX 4 x 3/4 entries G-0215 ED.2017 A.31

Ex d Installation and mounting methods Example of pole mounting Pole mounting system with bracket Details of the pole mounting bracket 1. EYS sealing fitting 2. hot dip galvanised steel pole 3. EYS sealing fittings 4. Type SX-59.1 junction box complete with cable glands 5. NP nipple A.32 ED.2017

Photometric diagram Ex d EWA-50 250W halide EWA-50 250W mercury EWA-50 250W sodium EWA-50100 400W halide EWA-50100 400W sodium EWA-50100 400W mercury On Cortem Group web site you can download.ldt and.ies lighting data files for the design and simulation of lighting levels in 2D and 3D, rendering and ray tracing. = plane 90270 = plane C 01 ED.2017 A.33