Hiross XDFN Closed Loop Cooling for High Density Racks. Precision Cooling for Business-Critical Continuity

Similar documents
THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

JAWAHARLAL NEHRU UNIVERSITY

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

EHDC. Cooling system for Data Center and server cabinets.

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

How To Make A Data Center More Efficient

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

In Row Cooling Options for High Density IT Applications

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Choosing Close-Coupled IT Cooling Solutions

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Blade Servers and Beyond: Adaptive Cooling for the Next Generation of IT Systems. A White Paper from the Experts in Business-Critical Continuity

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Hiwall Hiross for Telecom. High Performance Air Conditioning

Elements of Energy Efficiency in Data Centre Cooling Architecture

IPSIP M series-m Modular Data Center

As close to perfection. development and production. Modular data center

POWER. Your Partners in Availability POWER

The Different Types of Air Conditioning Equipment for IT Environments

CRAC Precision climate control units for data centres

Eaton 93PM UPS Where aesthetics meet intelligence.

APC APPLICATION NOTE #92

Managing Cooling Capacity & Redundancy In Data Centers Today

Blade Server & Data Room Cooling Specialists

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

How To Power A Bladecenter H Servers

Efficient and secure IT infrastructure Solutions for your data centre

RiMatrix S Make easy.

Tech Byte 27: Small Computer Room and IT Closet Cooling

Power distribution in data centres

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

SERVER ROOM CABINET INSTALLATION CONCEPTS

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Phase Modular Finally the benefits of Modular ups are for all

Fujitsu PRIMERGY BX600 S3 Blade Server

Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

The New Data Center Cooling Paradigm The Tiered Approach

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Containment Solutions

EMAC. Environmental Monitoring & Access Control

Case Study: Guaranteed efficiency through standardised data centres

White Paper Rack climate control in data centres

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

The Mission Critical Data Center Understand Complexity Improve Performance

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Protecting Our Information, Protecting Our Resources

Improve competiveness of IDC and enterprise data centers with DCIM

Managing Data Centre Heat Issues

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Sovereign. The made to measure data centre

Rack Power Distribution Unit For Critical IT Equipment

Server Room, Data Centre Management and Monitoring Solutions

Compaq Rack Options and Accessories. Monitors and Keyboards

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Data Centre Testing and Commissioning

Split units TH with hermetic compressors

Microsoft Technology Center: Philadelphia

How To Run A Data Center Efficiently

Virginia Tech. Background. Case Summary. Results

How To Use Rittal'S Rizone

Green Data Center and Virtualization Reducing Power by Up to 50% Pages 10

BELLE VUE MANCHESTER DATA CENTRE

Rittal the time has come...

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Onsite Support: 24/7/365 onsite team. Security: 24/7/365 onsite manned security and CCTV. Monitoring: 24/7/365 Environmental monitoring and management

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

State of the Art Energy Efficient Data Centre Air Conditioning

Data Centre Infrastructure Assessment

Energy efficient data centre cooling. InRack Cooling & The Intelligent Cooling System. aircold.dk

INFRASTRUCTURE FOR DATACENTERS

AIRAH Presentation April 30 th 2014

Data Centre Solutions energy efficient by design

Transcription:

Hiross XDFN Closed Loop Cooling for High Density Racks Precision Cooling for Business-Critical Continuity

Business-Critical Continuity Expert X-treme Solutions Adaptive Cooling and Power Architecture Whether you have to manage a 10 sqm Server Room or 1000 sqm Datacentre, we have the solution for your needs, from Closed Loop Rack Cooling to Integrated Cooling.

It was 24 kw per Room. It is 24 kw per Rack. Cool the Server not the Room Hiross XDFN: Air Flow Distribution Hiross XDFN Closed Loop Cooling for High Density Racks Taking Heat Removal to the X-treme Without Water Inside the Datacentre!

X-treme Solutions are the answer to this need. Up to 24 kw/rack Closed Loop Rack Cooling. Ideal for High Heat Density. Complete and integrated solution. Low cost of installation. Hot Spot Management New Technology Servers increase dramatically increase computing capacity which also means an increase of heat dissipation needs. A rack equipped with Blade Servers can easily exceed 20 kw thus creating hot spots not manageable with standard air conditioning solutions (refer to picture A where red hot spots are shown). Thanks to our expertise in Precision Cooling and AC Power Systems, we have designed an indoor enclosure system for high density servers with built in power back up (refer to picture B where the hot spots have been treated and cooled). A. Hot spot due to insufficient Cooling Hiross XDFN cools the Servers not the room and guarantees a safe protection for customers servers offering a complete solution for redundancy, power protection, fire extinguishing, back-up ventilation and SNMP monitoring. B. XDFN can restore the correct Temperature Adaptive

Adaptive Cooling and Power Architecture STAND-BY MAINTENANCE Adaptability Hiross XDFN is part of the Liebert Adaptive Cooling Architecture which can provide a roadmap to deal with increasing heat density, and with maximum flexibility and scalability and the lowest cost of ownership. N+1 Redundancy & Modularity The modular design allows redundancy, rapid replacement of faulty units and scalability. N+1 Redundancy configuration. For each block of XDFN units (cooling module+racks) there will be one redundant cooling module connected in LAN with the other cooling modules, ready to be activated in case of failure or maintenance of one of the running units. Back up Ventilation Hiross XDFN is also equipped with a back- up ventilation system which ensures the circulation, inside the rack, of the air coming from the data centre room in case of cooling module or mains power failure. Cost saving The UPS will be required to give power only to the small back-up fans, and not to the rest of the air-conditioner system. Safety Back up ventilation protects your business for enough time to allow the generator to start and restore the power supply, or for other causes of failure to be corrected. When power is restored, the back-up ventilation will be automatically switched off and the cooling module will run as in standard conditions. Stand Alone Singular unit reliable & simple Modular Standard units with fixed sizes that work together Cost savings by retaining initial investment Added redundancy

Optimal building blocks that work together Ultimate reliability, flexibility and lowest Total Cost of Ownership Fewest points of failure Reconfigurable to adapt to new technologies with the Capability to move to higher Tiers Integration Hiross XDFN is an integrated equipment cabinet with built in cooling, power distribution, rack for server location, monitoring and fire extinguishing system offering full redundancy and back-up ventilation. Monitoring and Control Hiross XDFN features an innovative 32 bit Microprocessor control offering the capability of integration in an SNMP monitoring system, or simple browsing of the unit through the web. Electrostatic discharge prevention Humidity is a key issue for Servers because both high and low humidity may damage the electronics. The cooling module is equipped with Humidity control in order to always keep the adeguate humidity level within the rack. Fire Extinguishing Scalable Flexibility with internal modularity A unit with single direction for growth Taking care of your business means providing protection for all possible situations. Therefore Hiross XDFN features a Fire Extinguishing System based on Vesda laser focus technology. Special sensors continuously monitor the air inside both the rack and inside the Cooling Module. If smoke is detected an inert gas will be introduced to mix with the air inside the Module to reduce the Oxygen level.

Monitoring & Control Control The control contributes to efficiency improvements by enabling more precise control of temperature and humidity and by allowing multiple XDFN units to communicate and work together as a system. It monitors all functions and generates reports or alarms as needed. It allows a service engineer, from a centralized location, to oversee the operation of Hiross XDFN. The Hiross unit has a Unit Diary that shares unit maintenance history with any authorized user or logged-in service contact, including records of what others have done. OpenComms Web Card The control through the OpenComms Web Card provides the Hiross XDFN system with SNMP and web-based management. The control can be set to be monitored and controlled not only from a Network Management Station, but also from any PC running Microsoft Internet Explorer. The animated Power Flow allows the condition of the system to quickly be determined. Rack Power Monitoring and Management Power distribution inside the Rack is crucial. We provide the capability to monitor and control each socket offering control of the total RMS Amp, RMS Volt and kw/h through SNMP, Telnet and WEB access.

Closed Loop Cooling for High Density Racks Hiross XDFN with digital scroll The cooling module, self-contained in the XDFN product, is a modular direct expansion unit with remote air cooled condenser. The cooling capacity is modulating thanks to the use of digital scroll technology. The refrigerant used is R407C. The Cooling module is available in different configurations, including chilled water on demand. The modular design of Hiross XDFN Closed Loop Rack Cooling allows for the racks and cooling modules to be combined, in order to provide cooling to multiple racks. Integrated 42U Racks and Accessories Hiross XDFN features a 42U Rack that can be configured according to users needs with the following accessories: Transparent or Solid Doors Basic Power Strip up to 48 outlets/rack Monitoring and Controlled sockets External keyboard tray Cable Management Rack Mounted on line UPS Hiross XDFN can be provided with UPS, PDU, Emergency back-up ventilation and Fire extinguishing. Hiross XDFN: can be configured according to user needs

Unique economical benefits Preventive environmental monitoring to guarantee maximum uptime Back-up ventilation to enable continued operation in case of mains power failure Hot-swap configuration to minimize restoration time after failure No noise impact on Datacentre Universal solution, no need for a dedicated installation area Smaller footprint than any equivalent solution with n+1 redundancy Each cabinet works independently without affecting adjacent units Fire extinghishing system within the rack Low Totral Cost of Ownership Simple maintenance High efficiency Hiross XDFN is a perfect solution also for small offices and small Datacentres. It could be easily installed in a separate technical room without impacting on the existing cooling configuration. Hiross XDFN Technical Data Performances Net Sensible cooling capacity DX kw Up to 23,6 Net Sensible Cooling Capacities CW kw Up to 25,6 Dimension & Weight Cooling Module + Rack Cooling Module Width mm 1600 mm 750 Depth mm 1200 mm 1200 Height mm 2400 mm 2400 Weight kg 764 kg 445

103712 The Quality Management System of the High Performance Air Conditiong Division of Liebert HIROSS SpA is certified by Lloyd's Register Quality Assurance to ISO 9001:2000 While every precaution has been taken to ensure accuracy and completeness in this brochure, we assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. All rights reserved throughout the world. Specifications subject to change without notice