Fire Engineering Seminar

Similar documents
SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS

Fire Safety In High Rise Building

Introduction. CE marked construction products

Northern Ireland Housing Executive: HMO Fire Safety Guide

- 5 - Table1. Maximum Compartment Volumes

Fire precautions in dwellings. Private sector housing Providing homes building communities

HOUSES IN MULTIPLE OCCUPATION STANDARDS. Housing Executive

RESIDENTS FIRE SAFETY INFORMATION PACK

Guidance on loft conversions in two-storey houses

RESIDENTS FIRE SAFETY INFORMATION PACK

Errata has been identified as follows:

Contents. 1. Introduction 1.1 Reason for this Guide Interpretation 1.3 Principles of Fire Safety 1.4 Legal Provisions 4

RESIDENTS FIRE SAFETY INFORMATION PACK

Fire. The Fire Installers Mate. A guide to fire alarm systems design

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

I.S :2013 Fire Detection & Alarm Systems

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

FIRE SAFETY RISK ASSESSMENT

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

I.S :2013 Fire Detection & Alarm Systems

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

Building Control Guidance Note

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER May 2015

ON MOST schemes, the architectural design of. Flexible strategy. Case study. The Forum

Fire Alarm system Installation Guide

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Using Sprinkler Systems in Buildings and Structures Compliance with current fire safety guidance

Building Control Guidance Note

Overview of Hotel Fire Safety Requirements

What you need to know about. Smoke alarms for residential buildings

Chapter 2 MEANS OF ESCAPE

FIRE DETECTION AND ALARM SYSTEMS

Fire Strategy. Oak Park Care Home and Extra Care Block. 21 July 2015

REVIEW ON FIRE REGULATIONS FOR NEW HIGH-RISE COMMERCIAL BUILDINGS IN HONG KONG AND A BRIEF COMPARISON WITH THOSE IN OVERSEAS

James R. Quiter, P.E., Senior Vice President Rolf Jensen & Associates, Inc.

Appraisal of Passive and Active Fire Protection Systems in Student s Accommodation

Schedule B to By-law Part A Fees Payable for Permits

CHAPTER 9 FIRE PROTECTION SYSTEMS

3.In making the following determination, the Secretary of State has not considered whether the plans conform to any other relevant requirements.

Schedule B to By-law

FURNITURE & FURNISHINGS - FIRE SAFETY STANDARDS

FIRE ESCAPE SIGNS Guidance on compliance

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

A study of the nature of fire risks in tall buildings

Fire Safety Risk Assessment

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

Pollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

If you require any assistance with smoke control systems we can be contacted as follows:

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

FIRE RISK ASSESSMENT WORKED EXAMPLE

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

UPP Residential Services Fire Risk Assessment

Building Code Clarifications - 7. Fire Resistance

Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment

Fire safety advice for landlords

How To Build A Basement House

Practice Note

St. John s University

Fire Safety in High Rise Residential Blocks

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION

FIRE SAFETY PRINCIPLES FOR RESIDENTIAL ACCOMMODATION

Fire Safety Requirements for Child Care Centre

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

For use by landlords of small premises Premises Address

Technical Bulletin 005(A) Developed with Communities and Local Government

EVACUATION & LIFE SAFETY STRATEGIES FOR SUPER HIGH RISE BUILDINGS. Sam Aloi, Grad. Dip. (Fire Safety & Risk Eng.)VUT Melb, BE (Building) VUT Melb.

G SPECIFICATION: GAS METER AND REGULATOR INSTALLATION REQUIREMENTS. 3 and Gas Yellow Book. REVISIONS: (See ) 1/15/14 5 Years

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

London Borough of Barnet. Fire Safety in Houses in Multiple Occupation. A Guide to Landlords

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Indiana Building Rehabilitation Standard

Action required (Please tick) If you answered YES, record Action Points at STEP 4

Property Maintenance Check List

Guide to Houses in Multiple Occupation Self Contained Flats

Rochdale Building Control Guide. Approved Document F Means of ventilation

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

For use by landlords of small premises Premises Address

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

WATER INDUSTRY ACT South Australian Water Heater Installation Requirements. Prepared by the Technical Regulator

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

Decree of the Ministry of the Environment. on fire safety of garages

Fire Safety Management Strategy

What are we discussing with you today?

Access to and use of buildings

BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Fraternity and Sorority House Fire Safety

FIRE RISK ASSESSMENT

Certification: Building Plans Examiner. Exam ID: B3

2007 ICC FINAL ACTION AGENDA

BS5839 Part 1:2002 Overview

Excerpts from the Canadian National Building Code (NBC)

Transcription:

Fire Engineering Seminar BS 9991:2011 Fire Safety in the Design, management and use of residential buildings Martin Davidson Jeremy Gardner Associates

Traditionally prescriptive Reliance on Escape routes stairs, common corridors Containment by passive means Smoke detection Smoke venting in common areas.

BS 5588 Part 1 Maisonettes Alternative means of escape required where a floor > 4.5m above ground Only really worked for three storey buildings Problematic with taller buildings Common balconies for alternative means of escape Security and privacy issues Dual aspect units Can t get an alternative means of escape as there is no corridor on every floor.

BS 5588 Part 1 Smoke venting of common corridors Guidance very limited More than 1 stair 1m 2 Openable Vent Single Stair 1.5m 2 AOV. How many corridors connect directly with external? Vertical smoke shafts 1.5m 2 Open or closed at bottom? Alternative BRE Guidance Contentious

Travel distances BS 5588 Part 1 9m within apartments with kitchen away from exit Internal protected entrance hall with 9m travel distances Distances then unlimited within accommodation 7.5m single direction of travel in common corridor 30m where there is more than one stair

BS 5588 Part 1 Protected entrance halls Makes apartment entrance very dark Inefficient use of space Self closing fire doors Hazard to young children Disconnected by many No maintenance Effective?

Fires by Location

Fire Deaths by Location

BS 9991:2011 Published 31 December 2011 Supersedes BS 5588 Part 1 with immediate effect As with BS 9999, situation in Ireland as yet unclear TGD B currently being revised Deals with all parts of Building Regulations from B1 to B5. Similar in layout to TGD B More flexible design possible.

BS 9991:2011 Scope includes Houses Apartments and duplexes Sheltered housing Residential blocks (e.g. Student housing) Excludes Hotels, hospitals, nursing homes, hostels, prisons or houses of multiple occupancy.

Dwellings No changes for single or two storey houses 3 Storey Houses Alternative means of escape from top storey; or Protected stair; or Sprinklers throughout with fire separation of the ground from the upper floors Taller houses Floors >7.5m above ground should have an alternative means of escape or A protected stairway serving all floors plus sprinklers.

Apartment Blocks Residential buildings > 30m in height should be sprinklered Mechanical smoke ventilation for common corridors introduced Sprinklers and/or mechanical smoke ventilation recognised as alternative solution for extended travel distances in common corridors.

Balcony or Deck Approach Balcony should achieve 30 minutes fire resistance and be imperforate Should be designed to encourage smoke flow out and up. If more than 2m wide then downstands requried If there are voids in the balcony and there is a single direction of travel, unless the escape route is more than 1.8m away from the elevation a smoke analysis required.

Balcony Escape with Voids Flat Flat Flat >1.8m Single direction

Balcony with Single Direction of Escape Face of building should provide at least 30 mins (excluding windows) FD30 Doors Window openings should not extend below 1.1m above balcony Balustrade should be imperforate Walls, balcony and balustrade surfaces should be Class 0

Common Corridor to Flats or Maisonettes Travel distances have not changed from BS 5588 Part 1 7.5m in a single direction and 30m where there is an alternative Smoke ventilation provisions have changed More flexibility on extended travel distances depending on measures provided.

Smoke Control Where travel distances comply, primary purpose of smoke control is to protect the stair basis of stay put evacuation strategy Where travel distances are extended, primary objective is to protect both the stair and the corridor Natural or mechanical smoke ventilation Mechanical can be extract or pressurisation

BS 5588 Part 1 Ventilated

BS 9991 Smoke Control Where escape from flats is only via a corridor 7.4(a) the travel distance between the exit doors from the dwellings and a smoke-free area should be limited, and the amount of smoke and other combustion products in the internal corridor or lobby kept to a minimum by providing either cross corridor fire doors and ventilation, or a mechanical smoke ventilation system

Small Buildings with Single Stair Smoke venting of lobby not required where travel distances < 4.5m Stair can continue down to basement car park provided basement is ventilated and there is a ventilated lobby. 1m 2 OV at each level in stair or a single remotely operated vent at the top.

Section 26 Smoke Vent Single Stair > 11m Requirements 1.5m 2 AOV on the external elevation directly adjacent to the stair as high as possible and a 1m 2 AOV at the top of the stair; or 1.5m 2 vertical shaft directly adjacent to the stair as high as possible and a 1m 2 AOV at the top of the stair (fire fighting cores limited to 30m) ; or Mechanical extraction directly adjacent to the stair as high as possible and a 1m 2 AOV at the top of the stair

Mechanical Smoke Ventilation Usually incorporates a fan and a vertical shaft Where travel distance comply inlet via vent at top of stair Extended travel distances require inlet air provisions at each level Should shown better or equivalent conditions to the natural system using CFD analysis

Internal Layout of Flats Previous guidance retained Travel distances < 9m with no escape towards cooking areas Protected entrance hall with 9m travel distance Open plan flats permitted Sprinklers Size of flat < 16m x 12m Open plan flat should be single storey.

Internal Layout of Flats Open plan flats Ceiling height minimum 2.25m Where flat > 10m x 8m kitchen should be enclosed Where flat < 10m x 8m, kitchen can be open but located away from exit Open plan not permitted in sheltered housing.

Maisonettes Maisonettes < 4.5m above ground are the same as dwellings Maisonettes > 4.5m above ground have four options An alternative exit from any habitable room not on the entrance level A protected stair serving all rooms on upper level and 1 alternative exit A protected stair and LD1 detection if no floor >7.5m above or below entrance level A protected stair and sprinklers.

Variations Concept consistent with BS 9999 Where sprinklers fitted in flats travel distances can be increased In one direction from 7.5m to 15m More than one direction from 30m to 60m Extended travel distances can be addressed using mechanical ventilation.

Fire Fighting Facilities Buildings not fitted with fire mains Houses should have access to all areas to within 45m from appliance along route suitable for hose Flats should have vehicle access for a fire appliance not more than 45m from all points within each dwelling If sprinklers and no floor greater than 4.5m then distance can be increased to 90m in houses and 75m in flats provided fire brigade attendance time is less than 10m

Fire Fighting Facilities Fire fighting shaft required in buildings with floor greater than 18m (TGD B 20m) Sufficient number of fire fighting shafts should provided to meet hose coverage distances (60m) and at least two fire fighting shafts in a building with an area of more than 900m 2.

Fire Resistance Periods Error Why else would you bother?

Sprinklers Can be to BS 9251 if using table 3 ADB advises that limitations on the use of BS 9251 for buildings greater than 20m can be ignored If using table 4 then BS EN 12845 sprinkler system Tanks, pumps etc Any reductions in cost due to reduced fire resistance maybe cancelled out due to higher sprinkler system requirements.

Other Considerations Self-closing devices not required on fire doors within dwellings, flats or maisonettes except for door to communal areas Single stair building >11m stair should not continue down to basement unless it is sprinklered.

Other Considerations Lobby should have a falling dry main and be ventilated where it s a basement car park lobby vent should be 1m 2 AOV Currently current practice in Ireland is to provide double lobby protection in basement with one lobby ventilated with 0.4m 2 permanently open vent

London Edinburgh Dublin Belfast Galway