SnapLine. Page. Index

Similar documents
38 Series - Relay interface modules A

38 Series - Relay interface modules A

48 SERIES Relay interface modules 10 A

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

49 Series - Relay interface modules A. Features

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Safety technique. Emergency stop module BO 5988 safemaster

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

MasterINTERFACE 39 Series - Relay interface modules

Panel Meters and Controllers Modular Panel Meter Type EDM 35

MasterINTERFACE 39 Series - Relay interface modules

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

80 Series - Modular timers 16 A. Features

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

FP2 Relay. The Best Relaytion

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Schematic Mechanical Drawing Derating Curve. Input. Output. Product Catalogue

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RY2 miniature industrial relays

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Modular I/O System Analog and Digital Interface Modules

60 Series - General purpose relays 6-10 A. Features

40 Series - Miniature PCB/Plug-in relays A. Features

Relés e Contatores de Estado Sólido SIRIUS

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Energy Management Energy Meter Type EM23 DIN

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Pluggable interface relays CR-P Pcb relays

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

3753 en /b VE/B - VE/RG Va V riable speed drives

Proximity Switches RS (Reed Switch)

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

3-phase, bidirectional energy meter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models


PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Cable Plug acc. to DIN EN , Form A

GLOLAB Two Wire Stepper Motor Positioner

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Telephone- and leased line modem for industrial applications TD-36

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Y.LIN ELECTRONICS CO.,LTD.

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Current and voltage measuring relays

Features. Applications. Truth Table. Close

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

R.C.C.B. s two-pole LEXIC

650W Single Output Power Supply

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Proximity Sensors

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Analog signal converters CC-E I/I Current / current isolators

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

80 Series - Modular timers 16 A. Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Adjustment functions for both span and shift have been incorporated

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Quick Connect. quick - simple - efficient.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Multifunction devices

SINEAX U553 Transducer for AC Voltage

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Three-phase monitoring relay CM-PFE

S101D01/S101D02 S201D01/S201D02

LM118/LM218/LM318 Operational Amplifiers

Transcription:

SNAPLINE Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-4132 Muttenz 1, Switzerland Tel. ++41 61 / 466 33 33, Fax ++41 61 / 461 96 06 http://www.woertz.ch Woertz-USA 151 Discovery Drive, Unit 111 Colmar PA 18915 Tel. (215) 997 8855, Fax (800) 522-3868 http://www.woertz-usa.com, e-mail: woertz1@erols.com

SnapLine Index Page Introduction / 4 Diode terminals, SnapLine with diodes 1A / 1000 V 5 Transient Suppressor, SnapLine overvoltage protection 6 Reed and Signal relay terminals, SnapLine, 125 V AC, 0.5 resp. 2 A 7 Power relay terminals, SnapLine, 250 V AC / 6 A 8 Optocoupler terminals, SnapLine series, for DC loads 9 SnapLine high-speed optocouplers, DC or AC input, Push-Pull output 10 Optocoupler terminals, SnapLine, for AC/DC loads 11 Optocoupler terminals, SnapLine, for small and medium AC loads 12 Mini Regulator, SnapLine with low power voltage regulator 13 Potentiometer converter, SnapLine R/U converter, output: 0-10 V 14 Pt100 Converter, SnapLine (2) 3-wire Pt100 / U Converter, output: 0-10 V 15 Analog converter / Filter / Isolator, SnapLine U/U and I/U separation converter, output: 0-10V 16 SnapLine Inverter, 2-wire version for NPN/PNP or PNP/NPN conversion 17 Analog converter / filter 0-20mA, 4-20mA or 0-10V, output: 0(4)-20mA 18 3

Introduction / The Woertz series of SnapLine terminals offer the user a compact, DIN rail mounted method of providing a multitude of control interface functions including: - Power and signal relays - Power and signal optocouplers - Solid State Relays - Analog converters - Diodes and overvoltage protection - Voltage regulation - PT100 converters - And more The compactness of this series (5.08 x 44 x 86.5 mm) makes the relays a hot alternative in new designs and an ideal replacement for existing control units in both industrial and commercial applications. All SnapLine terminals have identical profiles and are equipped with an LED to indicate operation. The power and signal relays are internally equipped with a freewheel diode and protection against reverse polarity. Other distinct advantages include compatibility with our normal three level terminals for straight connections and a full line of standard or custom marking, test plug accessories, and cross connections. Compatible 3-level terminals 1. End barrier 2. Insulated cross connections with screws 3. Isolation strip, red, blue 10 x 4 x 20-pole 4. Cross connections, 20-pole Cross connections, 10-pole 5. Test plug with adapter 6. Marking material 30403 grey 30407T 81535/X X = number of poles 2, 3, 4, 5, or 10 30411 red 30412 blue 30413RO red 30413BL blue 30790 grey 80247 red 80248 black 35455/55xx see catalog 1 4

Diode terminals SnapLine with diodes 1A / 1000 V - SnapLine terminals with integrated diodes - Through-going, lamp control and common alarm functions - Applications: rectifier, surge suppression, logical functions, polarity protection etc. - Two SnapLine terminals can easily be connected as a 1.6 A full wave rectifier bridge - Modular stacking of common alarm or lamp control functions 45378T/2D 81535/x Insulated cross-connections w. screws 35455/55xx Labels for custom use RB/5x5 Diodes Max. reverse voltage Max. continuous current (single terminals) Max. continuous current (stacked, continuously operating terminals) Max. surge current Voltage drop over diode Leakage current Terminal Max. operating voltage Max. terminal current Nominal cross section of connecting terminals Maximum torque 1000 V 1 A 0.8 A 30 A about 0.8 V (max. 1.1 V) < 10 µa 400 V (SEV), 300 V (UL) 10 A -55 C up to +80 C 1 diode, anode in the middle, an additional terminal on top 1 diode, cathode in the middle, an additional terminal on top 2 diodes with common anode (lamp control function) 2 diodes with common cathode (common alarm function) 2 diodes with serial connection and common middle terminal 2 independent diodes 45378T/1A 45378T/1K 45378T/A 45378T/K 45378T/D 45378T/2D 5

Transient Suppressor SnapLine overvoltage protection - Very fast overvoltage protection for sensitive devices - Absorbs power pulses up to 600W during 1ms (10/1000ms wave-shape) - If overloaded, it makes a short circuit (Serial fuse gives an excellent protection) - Through-going conductors for high security - Bidirectional protection - Integrated, insulated extra terminal 45385T/5 81535/x Insulated cross-connections w. screws x=2, 3, 4, 5, 10 poles 35455/55xx Labels for custom use RB/5x5 Supply Fuse Typical use Protected device Protection diodes Maximum pulse energie Maximum surge current (one half wave 60Hz) Maximum repetitive surge current 5/ 12/ 24/ 48/ 110 V DC Maximum repetitive surge current 115/ 230 V AC Breakdown voltage at 10 ma: 5 VDC Breakdown voltage at 1 ma: 12/ 24/ 48/ 110 V DC Breakdown voltage at 1 ma: 115/ 230 V AC Maximum continuous overload 600 W / 1 ms; 2 kw / 100 µs 100 A 57 / 33 / 16 / 8.6 / 3.6 A 2.2 / 1 A 6.8 V DC ±5% 13 / 27 / 51 / 120 V DC ±5% 141 / 283 V AC ±5% 2 W (5 W / 60 s) Maximum rated current through terminal Nominal cross section of connecting terminals Maximum torque -55 C up to +80 C 10 A 5 V DC 12 V DC 24 V DC 48 V DC 110 V DC 115 V AC 230 V AC 45385T/7 45385T/1 45385T/2 45385T/3 45385T/9 45385T/5 45385T/4 6

Reed and Signal relay terminals SnapLine, 125 V AC, 0.5 resp. 2 A - Signal relay with one changeover contact (type C) or reed relay with a NO contact, in 5.08mm wide terminal housing - LED indicating on state - For applications where signal currents must be quickly and reliably switched - Available for common industrial voltages 45313T/12 45372T/2 81535/x Insulated cross-connections w. screws 35455/55xx Labels for custom use RB5x5 AC versions with rectifier instead of diode AC versions with rectifier instead of diode Output Max. switching voltage Max. switching current Max. breaking capacity (res. load) Contacts Max. contact resistance Min. load Mechanical contact life Electrical contact life Coil Operating voltage tolerance for U N <10V Operating voltage tolerance for U N >10V Control current at rated voltage (U N ) Pickup time / dropout time (DC-Version) Input / output dielectric strength Input / output creepage distance Reed relay 200 V DC / 125 V AC 0.5 A 10 W Closing contact (type A) 200 mω µa / mv 10 8 switching cycles 5 x 10 7 (load 24 V DC / 10 ma) ± 15% about 17 ma 1.0 / 0.5 ms 1.5 kv 1.6 mm -40 C up to +45 C Signal relay 200 V DC / 125 V AC 2 A 60 W Changeover contact (type C) 50 mω (1A) µa / mv 10 8 switching cycles 2 x 10 6 (load 24 V DC / 50 ma) ± 15% about 17 ma 1.5 / 1.0 ms 2.5 kv 3.0 mm -40 C up to +45 C 5 V DC 12 V DC 24 V DC 48 V DC 24 VAC (50-60 Hz) / DC 45313T/7 45313T/1 45313T/2 45313T/3 45313T/12 45372T/7 45372T/1 45372T/2 45372T/3 45372T/12 7

Power relay terminals SnapLine, 250 V AC / 6 A - SnapLine terminals with 1 power relay with changeover contact (type C) - 250 VAC/ 6 A breaking capacity - 5.08mm wide terminal housing - LED indicating on state - Available for all common industrial voltages - For many applications where isolation, minimum space and high power switching are required - An end barrier should be placed at the end of the terminal block 45314T/7 45329T/13 81535/x Insulated cross-connections w. screws 35455/55xx Labels for custom use RB 5 x 5 AC/DC versions: with rectifier instead of diode Contacts Max. switching voltage Max. switching current Max. continuous current (stacked terminals) Max. breaking capacity Max. contact resistance Min. load Mechanical life expectancy Coil Operating voltage tolerance for U N < 100V Operating voltage tolerance for U N > 100V Rated power Frequency Pickup time / dropout time Dielectric strength (Input - Output) Creepage distance (Input - Output) DC versions 250 V AC 6 A 5 A 1500 VA 100 mω (1A) 0.1 A / 12 V 5 x 10 6 cycles ± 10% 0.2 W (110 V : 0.5 W) 5 / 6 ms 4 kv 8 mm -40 C up to +45 C AC/DC versions 250 V AC 6 A 5 A 1500 VA 100 mω (1A) 0.1 A / 12 V 5 x 10 6 cycles ± 10% 0.25 W (115-230 V : 0.6 VA) 50-60 Hz 4 kv 8 mm -40 C up to +45 C 5 V 12 V 24 V 48 V 110 V 230 V 45314T/7 45314T/1 45314T/2 45314T/3 45314T/9 45329T/12 45329T/13 45329T/15 45329T/14 8

Optocoupler terminals SnapLine series, for DC loads - Signal and power optocoupler in 5.08mm wide terminal housing - LED indicating on state - Large product range - High fidelity - For many applications where rapid and reliable switching is important - An end barrier should be placed at the end of the terminal block - Available for all common industrial voltages 45306T/1 81535/x Isolated cross connections w. screws 35455/55xx Labels for custom use RB /5 x 5 5V versions without rectifier 100 ma 5 A 7 A Output Max. switching voltage Max. continuous current single/stacked Max. transient current Voltage drop (at 0.5 x I max ) 150 V DC, 45310: 50 V DC 100 ma / 100 ma 45305: 0.15 A / 0.1 ms 45310: 0.5 A / 10ms 45305: about 0.7 V 45310: about 0.1 V 55 V DC 5 A/4A 25 A / 0.1 ms max. 0.2 V 55 V DC 7 A/6A 100 A / 0.1 ms max. 0.1 V Input Operating voltage tolerance Input current at rated voltage Switch on level Switch off level Max. transmission frequency (res. load) max. 110-230 V: ±15% 6-9 ma 110-230 V: 2-3 ma > 0.8 x U n < 0.4 x U n 45305: 600 Hz, T/9: 300 Hz 45310: 10 Hz 5, 115, 230 V: ±15% about 5 ma 110-230 V: 2-3 ma > 0.8 x U n < 0.4 x U n 45306: 10 Hz, T/9: 5 Hz 45311: 5 Hz 5, 115, 230 V: ±10% about 5 ma 110-230 V: 2-3 ma > 0.8 x U n < 0.4 x U n 45307: 1 Hz, T/9: 0.5 Hz 45312: 0.5 Hz Input / output dielectric strength/ creepage distance 2.5 kv / 3 mm -25 C up to +45 C 2.5 kv / 3 mm -25 C up to +45 C 2.5 kv / 3 mm -25 C up to +45 C 5 V DC 12 V DC 24 V DC 48 V DC 110 V DC 24 V AC/DC 115 V AC/DC 230 V AC/DC 45305T/7 45305T/1 45305T/2 45305T/3 45305T/9 45310T/12 45310T/15 45310T/14 45306T/7 45306T/1 45306T/2 45306T/3 45306T/9 45311T/12 45311T/15 45311T/14 45307T/7 45307T/1 45307T/2 45307T/3 45307T/9 45312T/12 45312T/15 45312T/14 9

SnapLine high-speed optocouplers DC or AC input, Push-Pull output - High speed active (push-pull) signal isolator in terminal housing, 5.08mm wide - LED indicating on state - For isolated data transmission up to 1.5Mb/s - As level shifter between systems with different voltage or earth potential - As booster / amplifier of weak signals - Direct interface to capacitive loads like MOSFETs and IGBTs - Proximity switch interface: PNP booster or NPN to PNP inverter - As sinus to square wave converter - Available for all common industrial voltages 45315T/7 81535/x Isolated cross connections w. screws 35455/55xx Labels for custom use RB / 5 x 5 AC versions with rectifier circuit instead of diode 10 Supply Supply voltage Supply current (no load) Output Output voltage (no load) Max. transmission frequency (res. load, DC=50%, i=30 ma) Max. output current (Source & Sink, f<500 khz) Transient current max. (Source & Sink) Input Input voltage tolerance Input current at rated voltage (U N ) Switch on level Switch off level Input/Output dielectric strength Input/Output creepage distance Size L x W x H (from rail) TTL/5 VDC 12 V DC 24 V DC 48 V DC 110 V DC 24 V AC/DC 115 V AC/DC 230 V AC/DC high-speed input 4-30 V DC 8 ma (DC), 17 ma (1.5 MHz) 0 < 0.3 V, 1 > U + - 2 V e.g. for TTL output: U + = 5 V 1.5 MHz 100 ma 0.4 A about 5 ma, 110 V: about 3 ma > 0.8 x Un < 0.2 x Un 5 kv 3.0 mm -10 C up to +45 C 45315T/7 45315T/1 45315T/2 45315T/3 45315T/9 AC/DC input 4-30 V DC 8 ma 0 < 0.3 V, 1 > U + - 2 V e.g. for TTL output: U + = 5 V 10 Hz (f AC > 45 Hz) 100 ma 0.4 A 115, 230 V: ±15% about 5 ma, 115-230 V: 2-3 ma > 0.8 x Un < 0.2 x Un 5 kv 3.0 mm -10 C up to +45 C 45316T/12 45316T/15 45316T/14

Optocoupler terminals SnapLine, for AC/DC loads - Optocoupler in 5.08mm wide terminal housing, for medium AC/DC loads - LED indicating on state - Versions for high voltages - For many applications where isolation, size and reliable switching are important - Available for all common industrial voltages 81535/x Insulated cross-connections w. screws x = 2, 3, 4, 5, 10 Pole 35455/55xx Labels for custom use RB 5 x 5 45374T/12 5 V version without rectifier Output Max. switching voltage Max. continuous current single/stacked Max. transient current during on state Voltage drop (at 0.5 x I max ) Input Operating voltage tolerance Input current at rated voltage Switch on level Switch off level Max. transmission frequency (res. load) (at DC=50%, i=0.5 x I max, U switch = 0.5 x U max ) Dielectric strength input / output Creepage distance input / output 4 A (low voltage) 40 V AC / 55 V DC 4 A / 3.5 A 25 A / 0.1 ms about 0.2 V 5, 115, 230 V: ± 15% about 5 ma, 110-230 V: 2-3 ma > 0.8 x U n < 0.4 x U n 45373: 10 Hz 45374: 5 Hz 2.5 kv 3.0 mm -25 C up to +45 C 1 A (high voltage) 250 V AC / 300 V DC* 1 A / 0.8 A 10 A / 0.1 ms about 1 V 5, 115, 230 V: ± 15% about 5 ma, 110-230 V: 2-3 ma > 0.8 x U n < 0.4 x U n 45375: 5 Hz 45376: 1 Hz 2.5 kv 3.0 mm -25 C up to +45 C 5 V DC 12 V DC 24 V DC 48 V DC 110 V DC 24 V AC/DC (50-60 Hz) 115 V AC/DC (50-60 Hz) 230 V AC/DC (50-60 Hz) For protection against accidental contact, an end barrier (30407T) should be placed at the end of a SnapLine block. 45373T/7 45373T/1 45373T/2 45373T/3 45373T/9 45374T/12 45374T/15 45374T/14 45375T/7 45375T/1 45375T/2 45375T/3 45375T/9 45376T/12 45376T/15 45376T/14 * Can switch up to 400VAC / 550VDC (0.2A), but due to limitations in isolation voltage and creepage distance, it must not be used where danger or damage can occur. 11

Optocoupler terminals SnapLine, for small and medium AC loads - AC optocoupler in 5.08mm wide terminal housing, for small and medium AC loads - LED indicating on state - Switching voltage up to 250 V AC - For many applications where isolation and rapid switching are important - Available for common industrial voltages 81535/x Isolated cross connections w. screws 35455/55xx Labels for custom use RB / 5 x 5 45308T/1 5 V version without rectifier Output Max. switching voltage Max. continuous current single/stacked Max. transient current during on state Voltage drop (at 0.5 x I max ) Input Operating voltage tolerance Input current at rated voltage Switch on level Switch off level Max. transmission frequency (res. load) 5 V DC 12 and 24 V DC 48 V DC Dielectric strength input / output Creepage distance input / output 50 ma 250 V AC* 50 ma / 50 ma 0.5 A / 0.1 ms about 2 V ± 10% ± 15% 11 ma > 0.8 x U n < 0.4 x U n 10 Hz 3.75 kv 3.0 mm -25 C up to +45 C 1 A 250 V AC* 1 A / 0.8 A 20 A / 0.1 ms about 1.5 V ± 10% ± 15% 11 ma > 0.8 x U n < 0.4 x U n 10 Hz 3.75 kv 3.0 mm -25 C up to +45 C 5 V DC 12 V DC 24 V DC 48 V DC 45308T/7 45308T/1 45308T/2 45308T/3 45309T/7 45309T/1 45309T/2 45309T/3 For protection against accidental contact, an end barrier (30407T) should be placed at the end of a SnapLine block. * If high voltage, high dv/dt or di/dt, it is recommended to use an RC network (snubber) across terminals 13 and 14 * If high voltage, high dv/dt or di/dt, it is recommended to use an RC network (snubber) across terminals 13 and 14 12

Mini Regulator SnapLine with low power voltage regulator - Low power shunt regulator in 5.08mm SnapLine housing - Protected against short-circuits (10s.) - Up to three terminals can be connected in parallel to increase output current - Available for the most common industrial voltages 45394T/21 s 81535/x Insulated cross connections w. screws 35455/55xx Labels for custom use RB / 5 x 5 Regulator part Max. input voltage Output voltage tolerance (at U N ) Maximum output current at rated input voltage U N Max. through-going current (0V/0V or U+/U+) Nominal cross section of connecting terminals U N + 10 % ± 5 % see table below 10 A -55 C up to +45 C UN: 12 V DC UO: 5.1 V DC/ 80 ma (Rz = 82 Ω, RLmin = 65 Ω) UN: 24 V DC UO: 5.1 V DC/ 35 ma (Rz = 470 Ω RLmin = 145 Ω) 45394T/17 45394T/27 UN: 24 V DC (Rz = 270 Ω, UO: 12.0 V DC/ 40 ma RLmin = 300 Ω 45394T/21 UN: 48 V DC UO: 5.1 V DC/ 15 ma (Rz = 2.2 kω, RL min = 330 Ω) U N : 48 V DC UO: 12.0 V DC/ 20 ma (Rz = 1.5 kω, RL min = 600 Ω) 45394T/37 45394T/31 U N : 48 V DC (Rz = 1.0 kω, UO: 24.0 V DC/ 20 ma RL min = 1.2 kω) 45394T/32 13

Potentiometer converter SnapLine R/U converter, output: 0-10 V - 3-wire potentiometer / 0-10V converter - Not isolated (common negative terminal) - Integrated low-pass filter suppresses disturbance - Output protected against overvoltage and shortcircuit - Wide supply voltage range - Wide range of potentiometers - LED indicating on-state - On request: 2-wire version, higher accuracy, wider temperature range 45377T/2 81535/x Insulated cross connections w. screws 35455/55xx Labels for custom use RB / 5 x 5 Supply Supply voltage Supply current (without load) Converter Potentiometer range Output voltage Conversion error Minimum load Low-pass filter Output protection Reference voltage for potentiometer 12-30 V DC 40 ma (at U+ = 24 V) 30 ma (at U+ = 12 V) 500 Ω -100 kω (higher resistance possible with lower accuracy) 0-10 V < 0.5 % (50 mv) (typ. <0.2%) 1 kω 10 Hz 11 V 5 V 0 C up to +45 C 45377T/2 14

Pt100 Converter SnapLine (2) 3-wire Pt100 / U Converter, output: 0-10 V - 5.08mm SnapLine terminal with a Pt100/U Converter 0-10V. - Integrated low pass filter for suppression of 50-60 Hz and other noise. - Low current through the sensor reduces self heating - Wide supply voltage range - If a 2-wire sensor is used: connect R2 and R3 together 45393T/1515 81535/x Insulated cross connections w. screws 35455/55xx Labels for custom use RB / 5 x 5 Supply Supply voltage Supply current (Pt100 connected) Converter Temperature range Output voltage Sensor current (approx.) Conversion error Min. output load Low pass filter cut frequency Overvoltage protection at the output 12-30 V DC max. 25 ma (U+ = 24 V) see table below 0-10 V 1 ma < 0.5 % (50 mv) (typ. < 0.2 %) 1 kω 12 Hz 12 V 0 C up to +45 C -50 C up to +150 C -50 C up to +50 C -20 C up to +60 C 0 C up to +50 C 0 C up to +100 C 0 C up to +150 C 0 C up to +200 C 0 C up to +300 C 0 C up to +600 C 45393T/1515 45393T/155 45393T/126 45393T/005 45393T/0010 45393T/0015 45393T/0020 45393T/0030 45393T/0060 On request Other temperature range, higher accuracy, other sensors (eg. Pt1000) 15

Analog converter / Filter / Isolator SnapLine U/U and I/U separation converter, output: 0-10V - 5.08mm Snap-Line terminal with an integrated isolation amplifier - Industrial standard inputs: 0-20 ma, 4-20 ma and 0-10 V. Output: 0-10 V - Standard version with low pass filter for suppression of 50-60 Hz and other noise - Fast (F) version with a cut frequency of about 20kHz for high speed applications - Wide supply voltage range - High isolation voltage 45387T/2 81535/x Insulated cross connections w. screws 35455/55xx Labels for custom use RB / 5 x 5 Input 0-10 V Input 0-20 ma Input 4-20 ma Supply Supply voltage (input and output) Supply current input (U 1 += 24 V) Supply current output (U 2 += 24 V), without load 12-30 V DC max. 20 ma max. 5 ma 12-30 V DC max. 20 ma max. 5 ma 12-30 V DC max. 20 ma max. 5 ma Converter Input range Output voltage range Input impedance Conversion error Min. output load Cut frequency of standard version Cut frequency of fast version (F) Overvoltage protection at the output Input / output dielectric strength Input / output creepage distance 0-10 V DC 0-10 V DC 1 MΩ < 0.5 % (50 mv) (typ. < 0.2 %) 1 kω 30 Hz 20 khz 11 V 2.5 kv 1.5 mm 0-20 ma 0-10 V DC 47 Ω < 0.5 % (50 mv) (typ. < 0.2 %) 1 kω 30 Hz 20 khz 11 V 2.5 kv 1.5 mm 4-20 ma 0-10 V DC 47 Ω < 0.5 % (50 mv) (typ. < 0.2 %) 1 kω 30 Hz 20 khz 11 V 2.5 kv 1.5 mm 0 C up to +45 C 0 C up to +45 C 0 C up to +45 C Standard version Fast version 45387T/2 45387T/2F 45388T/2 45388T/2F 45389T/2 45389T/2F On request Other input and output voltages and higher accuracy 16

SnapLine Inverter 2-wire version for NPN/PNP or PNP/NPN conversion - In terminal housing, 5.08 mm wide - Easy 2-wire configuration - Open collector output - Suitable as proximity switch inverter: PNP/NPN or NPN/PNP - Wide supply voltage range - High input resistance - Can be used as power driver interface for CMOS or TTL circuits 45323T/NP 81535/x Insulated cross connections w. screws 35455/55xx Labels for custom use RB 5 x 5 45323T/NP NPN to PNP 45323T/PN PNP to NPN Technical data (T a =25 C) Supply voltage (U N ) Output Voltage drop over output switch (i = 30 ma) Max. transmission frequency (res. load, DC = 50%, i = 30 ma) Max. output current, sink (45323T/PN) or source (45323T/NP) Input Min. input impedance Voltage between Ui and U+/0V terminals for secure on level (i=10ma) Max. terminal current Size L x W x H (from rail) 5-60 V DC 1 V 5 khz 100 ma 12 kω > 2.5 V 10 A -40 C up to +70 C "0 V" to "U + " out inverter (NPN to PNP) "U + " to "0 V" out inverter (PNP to NPN) 45323T/NP 45323T/PN On request Higher voltage range, higher output current or other input impedance 17

Analog converter / filter 0-20mA, 4-20mA or 0-10V, output: 0(4)-20mA - 5.08 mm SnapLine converter with integrated, non isolated analog converter - Industrial standard inputs: 0-20 ma, 4-20 ma or 0-10 V, output: 0(4)-20 ma - Standard version with integrated low-pass filter for suppression of 50-60 Hz and other noise - Alarm output for open output circuit (CP) - Integrated LED indicating on state - Wide supply voltage range - High input impedance for voltage input, low input impedance for current input - 30403 Compatible 3-step terminal 30413RO, BL Cross connection 20-pole red, blue 81535/x Insulated cross connections w. screws 35455/55xx Labels for custom use RB 5 x 5 45441T/2 Technical data Input 0-10 V Input 0-20 ma Input 4-20 ma Supply Supply voltage range Max. supply current (20mA load, U+=24V) 8.5-30 V DC 30 ma 8.5-30 V DC 30 ma 8.5-30 V DC 30 ma Converter Input range Output Input impedance Conversion error Output load at U+=24V Output load at U+=12V Cut frequency of the low-pass filter Output function CP (Current Present) 0-10 V DC 0(4) - 20 ma 100 kω < 0.5 % (100 µa) (typ. < 0.2 %) max. 750Ω max. 180Ω about 15 Hz switch closes towards 0V, if output current > approx. 1 ma 0-20 ma 0(4) - 20 ma 100 Ω < 0.5 % (100 µa) (typ. < 0.2 %) max. 750Ω max. 180Ω about 15 Hz switch closes towards 0V, if output current > approx. 1 ma 4-20 ma 0(4) - 20 ma 100 Ω < 0.5 % (100 µa) (typ. < 0.2 %) max. 750Ω max. 180Ω about 15 Hz switch closes towards 0V, if output current > approx. 1 ma Max. voltage / Min. load resistance at the CP output 30V / 1kΩ 30V / 1kΩ 30V / 1kΩ 0 C up to +45 C 0 C up to +45 C 0 C up to +45 C 0-20mA Output 4-20mA Output 45441T/2 45444T/2 45442T/2* 45445T/2 45443T/2 45442T/2* On request Wider temperature range, other input or output ranges, higher accuracy Fast version (F) with higher cut frequency * both current ranges included 18

09.2002 / 1 500 E