Battery Isolators. User Manual

Similar documents
PSC-A5 Solar Charge Controller Manual

12 Volt 30 Amp Digital Solar Charge Controller

OUTPUT CABLE CONNECTIONS:

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Solar Controller / Battery Charger User s Manual

GST301. (Single Protection Zone) Operation Manual

Charge Regulator SCR 12 Marine

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Operating Instructions

REAR-VIEW CAMERA INTEGRATION FOR SELECT CHEVROLET, CADILLAC & GMC VEHICLES 2013-UP

GV-VR605A DC Voltage Regulator

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

Xenon HID Lighting System

Operating Instructions

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

13 Watt PORTABLE SOLAR POWER KIT

Manual for Fire Suppression & Methane Detection System

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Manual. Solar Fountain Mobile Phone Charger

M3-ATX-HV. 6-34V Intelligent ATX Power Supply. Installation Guide Version 1.0c P/N M3-ATX-HV-01

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Fire Alarm Control Panel. Family. Operating Manual

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

Color Mark Sensor with Red or Green LED E3S-VS

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

Emergency lighting units EM powerled

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Section D..General Auto Electrical Corporation

INSTALLATION AND OPERATION MANUAL

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

DALI RC BASIC SO. Control unit Operating instructions

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

instabus KNX / EIB System System E F G H

POINTS POSITION INDICATOR PPI4

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

PUSH BUTTON START INSTALLATION MANUAL

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

CB200W Water Leak Detection Panel Application Guide

e-ask electronic Access Security Keyless-entry

Points Position Indicator (PPI1) for Points Motors with Common Ground

i ChatterBox! Motorcycle Security

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Multi-Protocol decoder with Load regulation

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

SYSTEM 4C. C R H Electronics Design

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

DC DC CONVERTER 1000W VDC Input / 12VDC Output

Operating Instructions

Renewable Energy Monitor User Manual And Software Reference Guide. (979)

Absolute Rotary Encoder E6CP

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

EC450 Power Control System

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

How To Power A Schen

Original instructions Tina 3A/Aps Adaptor unit

KVT-729DVD INSTALLATION MANUAL

AC-115 Compact Networked Single Door Controller. Installation and User Manual

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Operational Overview and Controls Guide

Telefon (+45) Telefax (+45) Installation and operating manual

ST Series POWER SUPPLIES USER INSTRUCTIONS

Manual Ranging MultiMeter

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

RADIANT PLASMA 4700 Plasma Spark Generator

AUTODIALLER / QUICKDIALLER - SA132

Mobile Data Power Model: MDP-25

HM-W536 Install Guide

Q1-750 Q Q Q Q2-200 Q4-90 Q4-120 HIGH PERFORMANCE AMPLIFIER

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Tina 2A/B Adaptor unit

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

INSTALLATION GUIDE. FCC ID NOTICE

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

70-Series CAN Power Management System

Operating Instructions

Multi-Protocol decoder

Odyssey of the Mind Technology Fair. Simple Electronics

User Manual for CH-PFC76810

Product Specification instalert Rapid Messenger Variable Message Sign

1R / 4-BUTTON SERIES

Transcription:

Battery Isolators MB-3680 (12V-100A) and MB-3682 (24V-100A) User Manual REV.0 2011 / 02 7673-2112-2300

1. Introduction And Intended Applications This innovative battery isolator is the only one in the market with separate settings for disconnect and reconnect voltages. The independent settings of voltages cover a much wider and precise application requirement and types of batteries. Intended Applications: caravan, car with second battery, solar /wind charging multiple battery banks and battery over discharge or over charge. This unit when used between two batteries, it functions as an isolator as following: It isolates the main (starting) battery from the second battery in normal condition. It allows charging of the second battery only when the main battery is at the selected voltage level set in LVR (Connect). This way, it also diverts excess power from the alternator to run equipment that feeds from the second battery. It does not allow the second battery to power the car electronics or feed into the starting of the car unless the manual Over-Ride Connection is activated. It prevents excessively large charging current dumping into the depleted second battery from the main battery. When used with one battery When it is used with one battery and a load, it acts as a low voltage cut off to keep the battery from over discharge according to the selected voltages settings.

2. Explanation of panel 1. Black Wire for connection to Ground or Negative of battery 2. Yellow Wire when connected to a positive(+) battery terminal, it activate Connection of Main and Aux terminal. Isolate this wire when not in use. 3. Main Terminal for connection to the Positive battery terminal of main (starting) battery. 4. Disconnect Voltage Selector LVD 5. Dual colour LED Indicator: A. No light = Disconnect; Green light = Connect B. Red light solid = Over Voltage Protection for Main Terminal Red light slow flash = Over Temperature Protection Red light fast flash = Over Current Protection 6. Connect Voltage Selector LVR 7. Auxiliary Terminal for second battery or load

3. Installation notes: 1. Negative Ground convention is used, that is the chassis of vehicle is connected to the negative terminal of the starting battery. 2. Whenever possible, use the shortest connection to the unit and batteries. The voltage drop of large current will affect the accuracy of isolator if cable size and length are not correctly selected. Please refer to the following link... http://www.zetatalk.com/energy/tengy10s.pdf 3. Always double check the tightness of all connections by wiggling the connected terminals and etc. Connectors and fasteners are prone to vibration loosening in a moving vehicle. Loosen connections cause sparks. 4. Make sure the yellow wire (2) is isolated and insulated if not in use. Use a toggle switch to connect this yellow wire to the positive terminal of the battery for manual connection of the Main and Aux terminals. 4. Installation for a Two Battery System 1. Select the suitable Disconnect (LVD) and Connect voltages (LVR) according to your requirement. For a normal 2 battery system the LVD is about 12.4V and LVR is about 13.3V. However the selections depend on the relative capacity difference of the 2 batteries and load at the auxiliary battery. It is advisable to make the difference between LVD and LVR wider if rapid on off actions occur frequently. 2. Please note that for the unit to function properly selections of LVR is always greater than LVD. 3. Switch off the car of DC charging source, connect the Main terminal first then the Aux. terminal. Switch on the car or the DC charging source, if the main battery is full and the auxiliary is low the green LED will be on.

4. If the LED turns red at any time check on the specifications and make the necessary remedial action. There is no connection and operation when LED turns red. Once the fault has been cleared unit will return to normal operation. 5. Installation for a One Battery System 1. The selected LVD is usually lower than the two battery system since the unit here is mainly used as a protection against over discharging the battery. 2. However, the selection of LVD and LVR voltage are very much affected by the type of load and relative battery capacity. Select a higher LVD for relatively smaller load ; for high initial draw load such as Motor, choose a lower LVD. 3. It is advisable to use a higher value of LVR to ensure a more completed charging operation. 4. Check the battery s specifications for suitable LVR and LVD and in cycling or standby applications. 5. If the LED turns red at any time check on the section of LED INDICATIONS of the specifications and make the necessary remedial action. There is no connection and operation when LED turns red. Once the fault has been cleared unit will return to normal operation.

6. Features 1. 10 Selections of Disconnect Voltage 2. 10 Selections of Re-connect Voltage 3. MCU control with FET design resulting extremely low voltage drop & small standby current. 4. Wide Operating Temperature Range : - 40 C to + 60 C 5. Extruded Aluminum housing sealed with Polycarbonate end caps 7. Protections 1. Instant disconnection when main terminal drops to 8.5V. 2. Over voltage protection at the main terminal. 3. Over temperature to the isolator >90 C case temperature 4. Over current to the unit. 5. Input reversed polarity protection to Main Terminal (self reset)

8. Specifications Models MB-3680 MB-3682 Battery Voltage System 12VDC 24VDC Isolator Setting Tolerance: ±0.1Vdc for 12Vdc Tolerance: ±0.2Vdc for 24Vdc sys. sys. LVD LVD LVR (Connect) (Disconnect) (Disconnect) LVR(Connect) 10.5V 12.9V 21.0V 25.8V 10.9V 13.0V 21.8V 26.0V 11.2V 13.1V 22.4V 26.2V 10 Disconnect Voltage 11.5V 13.2V 23.0V 26.4V Selections and 10 Connect 11.9V 13.3V 23.8V 26.6V Voltage Selections. 12.1V 13.4V 24.2V 26.8V LVD = Cut Out = Disconnect. 12.4V 13.5V 24.8V 27.0V LVR = Cut In = Connect 12.6V 13.6V 25.2V 27.2V 12.8V 13.7V 25.6V 27.4V 13.0V 13.8V 26.0V 27.6V ON / OFF Delay Time For Isolator Mode 15 Seconds Protection Low Voltage Protection (No Delay) 8.5VDC ±0.5VDC 17VDC ±1.0VDC Over Voltage Protection 18.5VDC ±0.5VDC 34.5VDC ±1.0VDC Over Temperature Protection Yes Protection Current (Start Point) 150A Continuous Output Current 100A Maximum Output Current (1 Minute) 110A Operation Current Consumption (LED ON) 9mA Standby Current Consumption (LED OFF) 6mA Voltage Drop With 100A 300mV (Max.) (Main Batt. To Aux. Batt) Operation Temperature Range Manual Over-ride Indication By LED Dimension (L x W x H) Weight -40 to +60 Yellow cable (2) to Battery Positive triggers Main & Aux connection LED GREEN = Connect LED No Light = Disconnect LED RED Protection: 1) Solid RED = Over Voltage (OVP). 2) Slow Flash RED = Over Temperature (OTP). 3) Fast Flash RED = Over Current (OCP). 162x75x50mm (6.3x3.0x2.0 inch) 486g (17oz)

9. Dimension Diagram