Technical Solution & White Paper. AFDX/ARINC664 End System Testing JS, AIM GmbH 9.7.2012



Similar documents
Technical Solution & White Paper. AFDX/ARINC664 Switch Testing JS, AIM GmbH

AFDX/ARINC 664 Concept, Design, Implementation and Beyond

AFDX networks. Computers and Real-Time Group, University of Cantabria

Cyber-hijacking Airplanes:

AFDX Emulator for an ARINC-based Training Platform. Jesús Fernández Héctor Pérez J. Javier Gutiérrez Michael González Harbour

Sample Configuration Using the ip nat outside source static

AFDX / ARINC 664. Tutorial

Sample Configuration Using the ip nat outside source list C

Generic term for using the Ethernet standard in automation / industrial applications

Load Balancing ContentKeeper With RadWare

BarTender Integration Methods. Integrating BarTender s Printing and Design Functionality with Your Custom Application WHITE PAPER

enervista UR Setup Software Quick Connect Instructions:

PBA.pro Getting Started

Efficient Verification for Avionic Product Development

Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I

/ Administrator Training PAT-2012

PANDORA FMS NETWORK DEVICES MONITORING

CONTENTS. List of Tables List of Figures

Mixed-Criticality Systems Based on Time- Triggered Ethernet with Multiple Ring Topologies. University of Siegen Mohammed Abuteir, Roman Obermaisser

PANDORA FMS NETWORK DEVICE MONITORING

Quick Installation Guide Network Management Card

H.323 Traffic Characterization Test Plan Draft Paul Schopis,

SETUP MANUAL. Midmark Products over Thin Client Environments

Basics of VoIP Termination

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

How To Create An Intranet Site On A School Computer (For A School) On A Mac Or Pc Or Ipad (For Pc Or Mac) On An Ipad Or Ipa (For Mac) (For Ipa) On Pc

Choosing Tap or SPAN for Data Center Monitoring

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Realfax Service User Manual Version 4

Smart Cloud Solutions

Setup Cisco Call Manager on VMware

Load DynamiX Storage Performance Validation: Fundamental to your Change Management Process

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

Customer Managed Connectivity - Milan


64-Bit Compatibility with Micromeritics Applications

Android App for SAP Business One. Z3moB1le App Version 1.00 Pagina 1 di 12.

DSX-HSCS Hot Swap Comm Server

Ethernet A Survey on its Fields of Application

VALIANT COMMUNICATIONS

Expert Power Control NET 4x 8212 / 8213

A distributed approach to File Management in IMA2G

Using the RS232 serial evaluation boards on a USB port

Please purchase PDF Split-Merge on to remove this watermark.

Response time analysis in AFDX networks with sub-virtual links and prioritized switches

A Real-time Ethernet Prototype Platform for Automotive Applications

Yubico YubiHSM Monitor

Collaborating in California: Open HIL Test System Architecture uses the ASAM HIL API

Linux A multi-purpose executive support for civil avionics applications?

AP700 TM 4-Port FXS VoIP Gateway High Performance VoIP Gateway Solution

Create bridges, add ports, show bridge and port statistics, status, as well as the OVS database

A Beginner s guide to send data to Device Cloud from a ZigBee Network

BarTender Software Activation

Network Packet Analysis and Scapy Introduction

KofaxExpress. Installation Guide

Configuring WAN Failover with a Cisco 881 Router and an AirLink ES440

Configuring Simulator 3 for IP

Rapid Modular Software Integration (RMSI)

Dante: Know It, Use It, Troubleshoot It.

Performance of a webapp.secure Environment

How To Monitor And Test An Ethernet Network On A Computer Or Network Card

ENC Enterprise Network Center. Intuitive, Real-time Monitoring and Management of Distributed Devices. Benefits. Access anytime, anywhere

Redundant Serial-to-Ethernet Data Connections for Mission-critical Devices

Initial setup guide ViBE V3

USER GUIDE Programming Adapter Cable for Fujitsu Flash Microcontroller- F²MC-16LX/FR Family Fujitsu Microelectronics America, Inc.

Connecting your Blackberry to Aliant Hosted Exchange. Instructions for connecting Blackberry hand-held devices to Aliant Hosted Exchange

Analysis of Large Scale Data Volumes

FEC Secure IPSec Client

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15

Open EMS Suite. O&M Agent. Functional Overview Version 1.2. Nokia Siemens Networks 1 (18)

Integrating CoroSoft Datacenter Automation Suite with F5 Networks BIG-IP

Analyzer 2.0. Installation Guide. Contents

Figure 1: RotemNet Main Screen

From Fieldbus to toreal Time Ethernet

Technical Bulletin. Teledyne PDS Clock Synchronization Considerations. Version 1.2

NetApp Storage System Plug-In for Oracle Enterprise Manager 12c Installation and Administration Guide

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide

PERFORMANCE AND LOAD TESTING

Kaseya 2. User Guide. for Network Monitor 4.1

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

Share Point Document Management For Sage 100 ERP

PowerPanel for Linux Software

Performance Analysis of Time-Triggered Ether-Networks Using Off-The-Shelf-Components

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

Configuring a Trimble Sps 461 using the Ethernet Connection GETTING THE GPS ON THE NETWORK HTTP PORT. By Bob Glover

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Network FAX Driver. Operation Guide

windream with Firewall

PikeOS: Multi-Core RTOS for IMA. Dr. Sergey Tverdyshev SYSGO AG , Moscow

High-performance VoIP Traffic Optimizer Client Solution

Gateways and Their Roles

USB Driver Installation for Windows XP

Transcription:

Technical Solution & White Paper AFDX/ARINC664 End System Testing JS, AIM GmbH 9.7.2012 Page 1

General Following Paper outlines the AIM approach for testing AFDX/ARINC664 End Systems against the ARINC664 Specification. Firstly, an "E/S" is to be understood as outlined in the ARINC664 Specification. (See picture below ARINC664P7 specification page 10). Therefore, an E/S basically offers "only" the Sampling and Queuing Port Services (via AFDX COM and SAP Ports), which are used by an "Avionics Application" (see above) in the final system. For the outlined testing approach below, the "Avionics Application" is replaced by a "Test Application" which replaces the "Avionics Application" to handle all the necessary functionality required by the Test Equipment. The outlined approach is valid for E/S functionality testing (shown above). For this purpose, AIM offers a commercial off the shelf solution comprising the hardware and software and dedicated test scripts. Page 2

E/S Testing Approach The AIM solution for E/S testing is based on using only the AFDX lines for communication with the UUT. No additional interfaces (e.g. serial maintenance or standard Ethernet) are required. For E/S testing a corresponding Test Application is required on the UUT for the Test Equipment to verify and command the UUT in order to satisfy the Test Cases. The Test Application has been specified by AIM and is based on standard E/S Services such as AFDX COM and SAP Ports. This specification allows the UUT supplier to implement a Test Application for the UUT and using the available Scripts on the Test Equipment as a semi-off-the-shelf (minor adaptation) solution. Therefore the major effort for any customer is to implement this Test Application in accordance with the Test Application specification hosted on their E/S (UUT). Tests related to 615A Data loading require the use of the AIM EasyLoad615A software. Page 3

The off-the-shelf test scripts offer tests for checking the compliance of an E/S against the ARINC Specification ARINC664P7, Chapter 3 End System. The functionality and structured is as follows: E/S System Test Cases Overview Basic Communication Tests Receive Tests Transmit Tests Latency Tests Performance Tests Redundancy Tests File Transfer Tests Addressing Tests Jitter Tests MIB Tests ICMP Tests 62 Test Cases in total Page 4

Following Overview outlines the testing approach and the associated documents relations. Page 5

Following picture shows the PBA.pro Test Manager Project, setup with the E/S Testing Project. Page 6

The PBA.pro Test Manager automatically creates a PDF Test Report (customisable) which is shown below (excerpt of a full 14 pages report) Page 7

A commercial off the shelf (COTS) solution as described above can be offered from AIM as follows: - Test Standard Hardware: Boards only or the entire System - Test Standard Software: (PBA.pro-FD, PBA.pro-AFDX-2, PBA.pro-TSM, EasyLoad615A) - E/S Test Script Package: PBA.pro-AFDX-ES-TEST (PBA.pro Project and Python Scripts and Libraries) which also includes o End System Test Plan and Procedure: Text document only o Test Application Specification: Text document only o Python Test Application Example Template Script: for execution under PBA.pro with AIM AFDX hardware. Page 8