The RX imola clinical analyser

Similar documents
Discover Your Potential

Discover Your Potential

Unleash Your Potential

Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured.

INNOVATION TO MEET YOUR NEEDS

73 Series Spectrophotometers

AU480 Chemistry Analyzer In-Lab Training Manual

UV-Vis spectrophotometers

Clinical Chemistry Line

HumaStar 100 HumaStar 200

Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE

AU 400 T H E V I S I B L E D I F F E R E N C E A N A L Y S E R S Y S T E M F O R C L I N I C A L C H E M I S T R Y

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

VWR SPECTROPHOTOMETERS

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

Coatron A4. Fully automated Hemostasis Analyzer. Made in Germany REF: Innovation in Coagulation

THE ACTIVITY OF LACTASE

cobas c 111 analyzer Small box. Big performance

TRI-LEVEL CARDIAC CONTROL (CRD CONTROL 1, 2, 3)

ArtisanLink Staining System is an automated special stains slide

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Shimadzu UV-VIS User s Guide

The Determination of an Equilibrium Constant

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

OPSIS LiquidLINE KjelROC Distillation Unit

Carcinoembryonic Antigen (CEA)

Vitamin B12. ADVIA Centaur System

Agilent Cary 60 UV-Vis

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

for patient monitoring

TBA-FX8 Automated Clinical Chemistry Analyzer with Flexibility to Respond to Demands of Large-Scale Clinical Laboratories

Thermo Scientific NanoDrop Products. Revolutionary technology. Elegant simplicity. Instruments for microvolume analysis of biomolecules

PHENOLIC AND ANTIOXIDANT ASSAYS. Gaziosmanpaşa University

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

BACTERIAL ENUMERATION

Mitos P-Pump. product datasheet

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

The Determination of an Equilibrium Constant

To determine the mass of iron in one adult dose of either a ferrous sulfate or. ferrous gluconate iron supplement using a colorimetric technique.

Your Personal Pipetting Robot

Measuring Protein Concentration through Absorption Spectrophotometry

instruments Analytical Instruments for Science

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

Factors Affecting Enzyme Activity

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

ORGANIC SAMPLE PREPARATION

BY UV SPECTROPHOTOMETRY

CEM, First in Microwave Peptide Synthesis

Use of Micropipettes

Water Baths. with BioCote antimicrobial protection

BC Auto Hematology Analyzer

ab Protein Sumoylation Assay Ultra Kit

Amino Acid Analyzer L-8900

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

3.4 TEST FOR BACTERIAL ENDOTOXINS. Final text for revision of The International Pharmacopoeia

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Coordination Compounds with Copper (II) Prelab (Week 2)

Individualized Quality Control Plan

QuickZyme Soluble Collagen Assay

Protocol: HPLC (amino acids)

In vitro diagnostic reagent, calibrator and control material stability

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Cancer Antigen CA 125

Laboratory Procedure Manual

DENSITY MEASURING SYSTEMS

Biochemistry Validation Form

GC-xt. The most flexible GC /GC-MS liquid sample injector

Epinephrine/Norepinephrine ELISA Kit

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Hydrogen Peroxide Cell-Based Assay Kit

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

OT 40L / 90L. Laboratory Steam Sterilizers

Optimize Your Process Operations by Improving Process Monitoring

cobas 6500 urine analyzer series Fully automated urine work area on a modular platform

cobas 8100 automated workflow series 3-D intelligence in lab automation

Integrating Automated Systems for Regulated Bioanalysis Farmen, R.H., Struwe, P. and Groeschl, M.

Thermo Scientific NanoDrop One Microvolume UV-Vis Spectrophotometers. Intelligent microvolume analysis. Pipette. Measure. Know.

Dedicated and calibrated pipettes can reduce variability. The Most Expensive Test is a Retest By Ruth Noe, UK and Ireland Sales Manager

Flow Injection Analysis

Quaternary Ammonium Compounds DOC

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

ESS Method 130.1: General Auto Analyzer Procedures

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Randox Laboratories Ltd. - Product Pipeline Analysis, 2014 Update

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Content Sheet 3-1: Equipment Management Overview

TOTAL SULPHITE (SO 2 )

TurbiDirect TurbiCheck TurbiCheck WL

Titrette. class A precision. The next generation Digital Burette!

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Transcription:

a abc

The RX imola clinical analyser The RX imola clinical analyser offers an impressive range of time-saving, labour-saving and cost-saving features. It is capable of 400 photometric tests per hour, 250 ISE tests per hour. The RX imola is a true random access analyser: tests can be processed in any order and stat samples are analysed immediately. Dedicated software ensures the RX imola is straightforward to operate with a clear and logical display layout. The comprehensive range of reagents includes dedicated, liquid and one-shot reagents. The RX imola is fully supported by Randox reagents, calibrators, controls, quality control software and the RIQAS EQA programmes. In many respects the RX imola is a bigger brother of the well-established and popular RX daytona. Both are fully automated benchtop clinical analysers. Both use the same reagents, same controls, same calibrators and same software. However, the RX imola is more than just a faster version of the RX daytona. Additional features have been included to make the RX imola even more user-friendly and versatile. These include refrigerated storage of controls and calibrators and improved access for stat samples. The RX imola offers RX series convenience and flexibility as a stand-alone system in medium-sized laboratories. In larger laboratories the RX imola can be used as a stat system, a back-up system or a special chemistry system solely for lipids, diabetes, specific proteins or TDM testing.

RX imola specifications ANALYSER TYPE Benchtop fully automated random access clinical analyser ASSAY TYPE Colorimetric, UV, endpoint, kinetic, bichromatic, monochromatic, turbidimetric, sample blanking, reagent blanking and ISE procedures DIMENSIONS 147 kg. 970 mm x 690 mm x 580 mm TEST CHANNELS 60 photometric channels, 3 ISE channels THROUGHPUT 400 photometric tests per hour 250 ISE tests per hour SOFTWARE Logical, easy-to-use Windows -XP operating system Full quality control software for easy QC monitoring Bidirectional LIS/LIMS RS-232C interface SAMPLES 72 positions for routine samples, stat samples, calibrators and controls. 20 cooled positions (10 C) for onboard storage of calibrators and controls. Barcode identification of samples. Sample predilution, automatic re-assay STAT SAMPLES Removal panel for continuous loading of stat samples Immediate sampling interruption for stat samples SAMPLE PIPETTE Micropipette with liquid level sensor, crash detection, clot detection and bubble detection Alerts for haemolysed, icteric, lipaemic or turbid samples. Onboard control and calibrator dilution including serial dilution of calibrators REAGENTS 60 refrigerated reagent positions (8-15 C or 15 C below ambient) for 20, 50, 70 and 100 ml bottles Barcode reagent identification Inventory management monitors expiry and stability, calculates reagent volume and tests available REAGENT PIPETTES Separate reagent 1 and reagent 2 pipettes STIRRING SYSTEM Two variable-speed stirrers for optimised reagent performance CUVETTES 90 permanent glass cuvettes with onboard wash station and cuvette monitoring facility Cuvette reaction temperature (37 C ± 0.3 C) maintained by silicon rubber heating DETECTION Direct absorbance in cuvette (monochromatic or bichromatic) 12 wavelengths (340, 380, 415, 450, 510, 546, 570, 600, 660, 700, 750 and 800 nm) selected by diffraction grating ISE UNIT Integrated direct ISE unit for sodium, potassium and chloride AUTOMATION Automatic wake up, priming, washes and shutdown Automatic calibration and QC Alerts for reagent shortage, expired reagent, expired calibration

System overview a b c REAGENT SYSTEM Removable reagent carousel with positions for 20, 50, 70 and 100 ml reagent bottles 60 cooled reagent positions Barcode reagent identification On-board reagent inventory management system Liquid level detection Variable-speed stirrers for optimised reagent performance DETECTION SYSTEM Direct monochromatic or bichromatic absorbance measurement Halogen tungsten lamp light source 12 wavelengths available 340, 380, 415, 450, 510, 546, 570, 600, 660, 700, 750 and 800 nm CUVETTE SYSTEM 90 permanent glass cuvettes with curved inner surface to facilitate efficient mixing and cleaning Minimum cuvette volume of 150 µl allows reduced reaction volume On-board cuvette wash station Cuvette performance monitoring Variable speed rotors for effective mixing in the reaction cuvette Direct heating system maintains a constant temperature of 37 C d e SAMPLE SYSTEM Removable sample carousel for multiple tube sizes including primary tubes and paediatric cups 72 sample positions with removable panel for continuous loading of stat samples 20 cooled positions for calibrators and controls Barcode identification of samples Micropipette with liquid level sensor, crash detection, clot detection and bubble detection Sample, calibrator and control dilution including serial dilution ISE UNIT Integrated ISE unit Direct measurement of sodium, potassium and chloride a b c d e

Software overview The RX imola software is logical, versatile and easy to use. The full-colour Windows -based interface is designed for the convenient control of analyser functions, automation, inventory and data management. run screens Test selection Run monitor screen shows the status of each sample using colour-coded sample positions Estimated time to sampling completion and run completion Track sample progress in detail, including real-time results display Reagent inventory includes lot, volume remaining, tests remaining, stability and calibration validity Full patient demographics Automatic wake up time and sleep scheme parameter screens Set up chemistry and ISE parameters including user-defined instrument factors and units Program open channels Set up to 40 user-defined calculated test results Test profile options Define order of analysis Perform wash programmes calibration screens Calibrate chemistry and ISE parameters View calibration curves and calibration details Select calibration method qc screens Register quality controls Set user-defined multipoint rules to display warning or error messages View Levey-Jennings charts and quality control statistics Compare against the target value or the running mean system screens Set up communications Register reagents Define up to 50 normal ranges for each parameter Enable reruns Backup parameter information Backup data maintenance screens Monitor working hours of components Monitor temperature conditions and detector performance Over 100 sensor checks including compartment doors, lamp status, analyser performances and prime and wash functions

RX monza RX daytona RX imola The RX series of clinical analysers The RX monza, RX daytona and RX imola are benchtop clinical analysers. They offer an impressive range of time saving and labour saving features. abc International Headquarters Randox Laboratories Ltd., Diamond Road, Crumlin, Co. Antrim, United Kingdom, BT29 4QY Tel: +44 (0) 28 9442 2413, E-Mail: marketing@randox.com www.randox.com january 2006