1 Thermo Scientific Indiko Reagents for Immunosuppressant Drug Testing Complete solutions for patient monitoring The cost-effective Thermo Scientific Indiko benchtop analyzer and bar-coded reagent is designed for easy-of-use and load-up and walk-away convenience.
2 Thermo Scientific QMS Everolimus Immunoassay Accurate: Correlates well with gold standard methods Efficient: Excellent accuracy across assay range Rapid: Quick turn-around-time Limit Of Quantitation (LOQ): 2 ng/ml Reportable Range: 2 to 20 ng/ml Precision Control samples were tested in replicates of 2, twice per day for 20 days, yeilding a total of 80 replicates. Sample Mean (ng/ml) SD (ng/ml) % CV SD (ng/ml) Control Control Control % CV Reference Method Comparison Hitachi vs. LC-MS/MS Sample Type N Passing Bablok Regression Correlation Coefficient (r) Kidney Liver Heart* * Heart indication is ex-us only Another study compared QMS vs. various LC-MS/MS Method N QMS vs. System QMS vs. System Slope 95% CI Deming s Intercept 95% CI Slope 95% CI Passing-Bablok Intercept 95% CI (0.87 to 0.98) (-0.41 to 0.46) (0.87 to 0.98) (-0.15 to 0.54) (0.95 to 1.06) (-0.48 to 0.33) (0.95 to 1.08) (-0.50 to 0.17) EVEROLIMUS IMMUNOASSAY
3 Method Comparison Samples: 101 samples were analyzed by the Thermo Scientific QMS Everolimus Immunoassay on the Indiko vs. the reference Hitachi. Passing-Bablok Analysis: Indiko = 0.91* 0.07 with a correlation coefficient of Indiko (ng/ml) Line Deming Regr Ordering: for IVD use Item Number Description Format QMS Everolimus Immunoassay QMS Everolimus Calibrator Set QMS Everolimus Control Set Ordering: for use in European Union R1 22 ml, R2 8 ml 6 levels, 3 ml 1 vial each 3 levels 3 ml 1 vial each Item Number Description Format QMS Everolimus Immunoassay* QMS Everolimus Calibrator Set* QMS Everolimus Control Set* * not available in US R1 22 ml, R2 8 ml 6 levels, 3 ml 1 vial each 3 levels 3 ml 1 vial each Hitachi (ng/ml)
4 Thermo Scientific QMS Tacrolimus Immunoassay Accurate: Correlates well with the gold standard LCMS/MS methods Efficient: Quick turn-around of patient results Convenient: liquid ready-to-use reagents Limit of Quantitation: (LOQ): 0.9 ng/ml Reportable Range: ng/ml Precision Control samples were tested in replicates of 2, twice per day for 20 days, yielding a total of 80 replicates. Within-Run Total Sample Mean (ng/ml) SD (ng/ml) % CV SD (ng/ml) %CV Control Control Control Control Control Reference Method Comparison A comparison of the data between the Beckman Coulter AU680 and the LC-MS/MS. Transplant Type Number Slope Intercept Correlation All Kidney Liver Heart Comparative Method N Slope (95% CI*) LC-MS/MS System 383 LC-MS/MS System 232 Abbott Architect Tacrolimus Assay 208 Intercept (95% CI) (1.084 to 1.137) (0.31 to 0.76) (1.092 to 1.167) (0.42 to 1.01) (1.071 to 1.181) (-0.63 to 0.56) Correlation Coefficient TACROLIMUS IMMUNOASSAY
5 Method Comparison Method Comparison studies were performed between the QMS Tacrolimus Immunoassay and LC-MS/MS method for 136 kidney, 133 liver and 114 heart transplant patient samples. Additional method comparison studies were performed between the QMS Tacrolimus Immunoassay and Abbott Architect Tacrolimus Assay for a total of 208 kidney and liver transplant patient samples. Results of the Deming regression analyses for the study are shown. Samples: 101 samples were analyzed by the Thermo Scientific QMS Tacrolimus Immunoassay on the Thermo Scientific Indiko vs. the reference Beckman Coulter AU680 analyzer. Deming s Regression Anaysis: Indiko = 0.92 (AU680) with a correlation coefficient of Line Deming Regr Indiko (ng/ml) Ordering: Item Number Description Format QMS Tacrolimus Immunoassay R1 18mL, Extraction Reagent R2 12 ml 50 ml QMS Tacrolimus Cal Set Level A Level B-F 6 levels 4 ml, 1 vial 2 ml, 1 vial each 280-Q Rap/Tac/CsA Control Level Q* 4 ml, 4 vials Rap/Tac/CsA Control Level 1 4 ml, 4 vials Rap/Tac/CsA Control Level 2 4 ml, 4 vials Rap/Tac/CsA Control Level 3 4 ml, 4 vials *Can be used for low level control for Tacrolimus Olympus AU680 (ng/ml)
6 Thermo Scientific CEDIA Cyclosporine PLUS Assay Accurate: Lot-to-lot consistency Efficient: Two-point calibration curve Convenient: High and low range assays use same reagents Rapid: Single lysing step sample preparation Limit of Quantitation (LOQ): Limit of Quantitation is 25 ng/ml Reportable Range: 25 to 2000 ng/ml Precision Precision Controls were run twice a day in duplicate over 20 days for a total of 80 replicates. Low Range Assay n Mean Within Run Total SD CV% SD Control Level Control Level Control Level High Range Assay n Mean Within Run Total SD CV% SD Control Level Control Level Reference Method Comparison Low Range Assay Transplant Type x-axis Linear Regression Sy.x Deming s Sy.x r n Range All HPLC-MS 0.97x x ng/ml All EMIT 1.05x x ng/ml Kidney HPLC-MS 1.02x x ng/ml High Range Assay All HPLC-MS 0.97x x ng/ml All EMIT 1.00x x ng/ml Kidney HPLC-MS 0.99x x ng/ml *Refer to page insert for a addition information on method comparison
7 Method Comparison Samples: 115 samples were analyzed by the Thermo Scientific CEDIA Cyclosporine Assay on the Indiko vs. the reference Hitachi. Deming s Regression Anaysis: Indiko =1.01 (Hitachi) -2.6 with a correlation coefficient of :2 Line Deming Regr CsA Hitachi (ng/ml) HPLC-MS (ng/ml) Samples: 148 samples were analyzed by the CEDIA High Range Cyclosporine Assay on the Indiko vs. the reference Hitachi. Deming s Regression Anaysis: Indiko =1.00 (Hitachi) -1.8 with a correlation coefficient of Low-Range Performance High-Range Performance Slope Correlation Intercept Ordering: Item Number Description Format CEDIA Cyclosporine PLUS Assay R1 41 ml, R2 19 ml includes Low Range Calibrators A & B 1 vial, 2 ml each level CEDIA Cyclosporine PLUS 2 levels, 4 ml High Range Calibrator Kit 2 vials each Cyclosporine High Range Control 2 ml, 6 vials, Level 4 diluent 8 ml, 2 vials Cyclosporine High Range Control 2 ml, 6 vials, Level 5 diluent 8 ml, 2 vials 280-Q Rap/Tac/CsA Level Q* 4 ml, 4 vials Rap/Tac/CsA Control Level 1 4 ml, 4 vials Rap/Tac/CsA Control Level 2 4 ml, 4 vials Rap/Tac/CsA Control Level 3 4 ml, 4 vials *Can be used in place of Rap/Tac/CsA Level 3 Indiko (ng/ml) :2 Line Deming Regr Hitachi (ng/ml) CYCLOSPORINE PLUS ASSAY
8 Thermo Scientific CEDIA Mycophenolic Acid (MPA) Assay Accurate: Correlates well with gold standard methods Efficient: Two-point linear calibration Rapid: No extraction step Limit Of Quantitation (LOQ): 0.3 µg/ml Reportable Range: 0.3 to 10 µg/ml Precision Control samples were tested in replicates of 2, twice per day for 20 days, yeilding a total of 80 replicates. Sample Mean (µg/ml) Within-Run SD (µg/ml) %CV SD (µg/ml) Total %CV Control Control Control Ordering: Item Number Description Format CEDIA Mycophenolic Acid Assay CEDIA Mycophenolic Acid Calibrator Set MAS Mycophenolic Acid Control 1 Kit MAS Mycophenolic Acid Control 2 Kit MAS Mycophenolic Acid Control 3 Kit R1 26 ml, R2 11 ml 2 levels, 5.0 ml 2 vials each 1 level, 5.0 ml 4 vials each 1 level, 5.0 ml 4 vials each 1 level, 5.0 ml 4 vials each
9 Reference Method Comparison Hitachi vs. HPLC. Sample N Heart 96 Kidney 92 All 188 Regression Method Least Square Deming Slope Intercept Slope Intercept (1.061 to 1.166) (0.05 to 0.36) (1.094 to 1.200) (-0.04 to 0.28) (0.974 to 1.080) (-0.03 to 0.36) (1.006 to 1.113) (-0.13 to 0.25) (1.015 to 1.092) (0.09 to 0.34) (1.051 to 1.128) (-0.01 to 0.25) r Method Comparison A total of 188 pre-dose samples from adult transplant patients receiving mycophenolate mofetiel or mycophenolate sodium therapy were tested in a method comparison study using LC-MS/MS as the reference method. The table below summarizes the results of the study showing separate analysis by transplant type and together using EP Evaluator. In the regression method column, the slope and intercept results are presented with 95% confidence intervals in parentheses. Samples: 115 samples were analyzed by the CEDIA Mycophenolic Acid Assay on the Indiko vs. the reference Hitachi. Deming s Regression Anaysis: Indiko = 1.02 (Hitachi)-0.01 with a correlation coefficient of Line Deming Regr 8 Indiko (ug/ml) Hitachi (ug/ml) MYCOPHENOLIC ACID (MPA) ASSAY
10 Thermo Scientific CEDIA Immunosuppressant drug testing One of the most effective therapies for patients with endstage organ failure is solid organ transplantation. Typically, one or more immunosuppressive drugs (ISD) are used to prevent rejection of transplanted organs and tissues. Periodic measurements of a drug s concentrations are performed to allow physicians to make adjustments to the patient s drug therapy, ensuring long-term success. Immunosuppressant drug monitoring can be done by several methods; the most common is immunoassay. We offer the most comprehensive menu of Immunosuppressant Drug Management assays which are recognized worldwide for their ease-of-use, quality, performance, and lot-to-lot consistency. Full ISD menu on a single analyzer Convenient on-site testing Improved laboratory efficiency and turnaround time Flexibility in instrument placement Description CEDIA Cyclosporine PLUS Assay QMS Tacrolimus Immunoassay CEDIA Mycophenolic Acid Assay QMS Everolimus Immunoassay Sample Type Whole blood Whole blood Plasma Whole blood Thermo Scientific Indiko analyzer and immunosuppressant drug monitoring Thermo Scientific Indiko, together with a complete menu of immunosuppressant drug monitoring assays, provides an excellent solution for patient monitoring. Indiko allows for patient testing at a monitoring site improving turnaround time and enabling doctors to make critical decisions sooner. The Indiko benchtop analyzer also provides a single platform solution for all Thermo Scientific ISD immunoassays, improving laboratory efficiency. The continuous access allows for samples and reagents to be added without interrupting the testing process. Indiko is a fully automated bench top analyzer for clinical and specialty testing Indiko is an easy-to-use, cost-effective system designed for load-up and walk-away convenience. Intuitive user interface and many automated features help to manage the daily workflow. The self-contained Indiko, with its small footprint, fits ideally with laboratory space limitations. IMMUNOSUPPRESSANT DRUG TESTING
11 The compact Indiko requires very little space Flexible, easy operation Intuitive user interface with touch-screen option Streamlined information management with various reporting options, and advanced result inventory management A mix of sample cups and barcoded primary tubes can be used Automatic start-up protocol Loadable application data and calibrator and control values True walk-away analysis Different sample types can be analyzed at the same time Real-time QC program with multiple Westgard rules Continuous access to samples, reagents and cuvettes without interrupting the testing process Up to two hours walk-away time Cost-effective solution Unique, low-volume cuvette technology Very low volume of samples (2 to 120uL) and reagents (2 to 240uL) result in overall low waste Real-time QC program assures reliable performance Minimal daily maintenance maximizes analyzer uptime Water consumption: 1.5 liter/hour
12 Instrument Specifications Capacity Dimensions & Weight Power Supply Average Noise Level at 1 meter Deionized Water Consumption Environmental Conditions Regulatory Filter Measurement Temperature 37 ºC Light Source Absorbance Range Reaction Vessels On-board Capacity Thermo Scientific Indiko Up to 200 tests per hour for 1 reagent assays, approximately 100 tests per hour for 2 reagent assays 29.5 in / 75 cm (W) x 27.6 in / 70 cm (D) x 24.4 in / 62 cm (H), 51 in / 130 cm (H) with cover open, 187 lbs / 85 kg V ± 10%, Hz, ± 5%, 250 W < 60 db (A) 1.5 liters/hour Operating temperature range 18 to 30 ºC, humidity 40-80% (non condensing) Confirms with CAN/CSA-C22.2 No FDA clearance, 510(k) number: k (Indiko ) 98/79/EC IVD MD Directive nm Flash Lamp Reaction End Volume µl Samples & Reagents On-board Capacity Sample Volume Size µl Sample Containers Sample Barcode Reagent Volumes µl Reagent Containers A, resolution of A and reproducibility of SD <0.005A at 2A 360 measurement cells - 36 cuvettes with 10 reaction cells each, up to 2 hour walk-away time, depending on workload Maximum 6 racks - 9-position sample rack or 6-position reagent rack in disk cooled about 8 ºC below ambient temperature, depending on workload 0.5 ml, 2.0 ml cups and sample tubes (diameter mm, length mm) Code 128 and barcodes USS Codabar, Interleaved 2 of 5 and Code 39 with a check digit 10 ml and 20 ml vials Sample & Reagent Dispensing CV 2% for volumes 2 µl Calibration Data Management Factor, bias, linear, logit-log, spline, polynomial & point-to-point calibration Windows -based workstation - data input online, via mouse, keyboard, barcode reader, and touch screen (optional) Thermo Scientific Indiko Plus Up to 350 tests per hour for 1 reagent assays, approximately 200 tests per hour for 2 reagent assays 37 in / 94 cm (W) x 27.6 in / 70 cm (D) x 24.4 in / 62 cm (H), 51 in / 130 cm (H) with cover open, 242 lbs / 110 kg V ± 10%, Hz, ± 5%, 300 W < 60 db (A) 2.5 liters/hour Operating temperature range 18 to 30 ºC, humidity 40-80% (non condensing) Confirms with CAN/CSA-C22.2 No FDA clearance, 510(k) number: k (Indiko Plus ) 98/79/EC IVD MD Directive nm 37 ºC Flash Lamp A, resolution of A and reproducibility of SD <0.005A at 2A 360 measurement cells - 36 cuvettes with 10 reaction cells each, 1 to 3 hour walk-away time, depending on workload µl 54 samples - 9-position sample rack, max 6 racks; 42 reagents in disk cooled about 8 ºC below ambient temperature, depending on workload µl 0.5 ml, 2.0 ml cups and sample tubes (diameter mm, length mm) Code 128 and barcodes USS Codabar, Interleaved 2 of 5 and Code 39 with a check digit µl 10 ml and 20 ml vials CV 2% for volumes 2 µl Factor, bias, linear, logit-log, spline, polynomial & point-to-point calibration Windows -based workstation - data input online, via mouse, keyboard, barcode reader, and touch screen (optional) Consumable Ordering Information Part Number Description Kit Configuration TENCELL cuvettes 1 box (10,800pcs) ml sample cups 1000 pcs ml sample cups 1000 pcs ml reagent bottles 5 pcs ml reagent bottles 16 pcs SP06662 Reagent rack 3 pcs SP06666 Sample rack 6 pcs Washing solution 4.5% 4 x 20 ml Tubing maintenance solution 6 x 20 ml thermoscientific.com/diagnostics 2014 Thermo Fisher Scientific Inc. All rights reserved. Copyrights in and to portions of the illustrations are owned by a third party and licensed for limited use only to Thermo Fisher Scientific by Getty Images. CEDIA is a registered trademark of Roche Diagnostics. Beckman Coulter is a registered trademarks of Beckman Coulter, Inc. Windows is a registered trademark of Microsoft Corporation. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. Information and technical specifications are subject to change without notice. Diagnostics USA Fremont Blvd. Fremont, CA USA Tel [email protected] Asia Pacific Fax [email protected] Australia Tel [email protected] MTL IndikoISD 2013/12 Belgium, Netherlands & Luxembourg Tel [email protected] Canada Tel [email protected] China Tel [email protected] France Tel [email protected] Germany Tel [email protected] New Zealand Tel [email protected] Nordic Tel [email protected] Spain, Portugal & Italy Tel [email protected] Switzerland & Austria Tel [email protected] United Kingdom & Ireland Tel [email protected] For countries not listed: [email protected]
Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
INNOVATION TO MEET YOUR NEEDS
INNOVATION TO MEET YOUR NEEDS 100% High Throughput The throughput is optimized splitting the pipetting phases of Reagents and Samples into different cycles. The innovative technical solutions adopted by
Cell Viability You Can Count On
Technical Information Sample Volume: 8 µl sample 3401 Masons Mill Road Suite 100 Huntingdon Valley, PA 19006 Dynamic Range: 5 x 10 4 to 1 x 10 7 cells/ml Detectable Cell Diameter: 8-40 microns Calculation:
Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer
Pore size and BET surface area analysis at your fingertips. SA 3100 Gas Adsorption Analyzer The History of Beckman Coulter Particle Characterization Introducing The SA 3100 Surface Area and Pore Size Analyzer
Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO
Instrument Adaptation The attached instrument adaptation has been prepared and validated by the reagent manufacturer, Hyphen-Biomed. Instrument Siemens BCS-XP Product BIOPHEN Heparin LRT Analyte Rivaroxaban
Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE www.tosohbioscience.us
Symmetry in Diagnostics HPLC ANALYZER Gold Standard Accuracy by Ion-Exchange HbA1c TOSOH BIOSCIENCE www.tosohbioscience.us HPLC ANALYZER HbA1c analysis in 1.6 minutes Direct determination of stable HbA1c
Discover Your Potential
Discover Your Potential Efficiency. Power. Flexibility. Small In Size Big In Performance. respons 910 A Leap Forward For Your Laboratory. Superior system solution including respons system reagents, analyzer,
Samsung POINT OF CARE Systems - Cardiac/Acute Care Biomarkers LABGEO IB Clinical Chemistry Analytes LABGEO PT
Samsung POINT OF CARE Systems - Cardiac/Acute Care Biomarkers LABGEO IB Clinical Chemistry Analytes LABGEO PT Alexander Belenky, PhD Director -Product Development Samsung - Nexus-Dx Edward Brennan, PhD
A Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,
Discover Your Potential
Discover Your Potential Efficiency. Power. Flexibility. Small In Size Big In Performance. respons 910 A Leap Forward For Your Laboratory. System solution consisting of respons 910 analyzer, intuitive software,
Your Personal Pipetting Robot
Your Personal Pipetting Robot Quality creates value www.dornier-ltf.com Easiness meets......versatility The PIRO Liquid Handling System provides a versatile pipetting platform with many options for the
Unleash Your Potential
Unleash Your Potential Efficiency. Power. Flexibility. Small In Size Big In Performance. The respons 910 vet A Leap Forward For Your Laboratory. System solution consisting of the respons 910 vet analyzer,
Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.
Thermo Scientific Barnstead TII Pure Water Systems Pure water. Pure research. Total confidence. Thermo Scientific Barnstead TII Pure Water Systems Ideal for any daily application needs for pure water,
Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured.
Cedex Bio HT Bioprocess Analyzer Be Confident. Be Assured. Next Generation Technology for Bioprocess Analytics Analyze Your Samples with Confidence. Be Assured of the Data Integrity. Metabolite Screening
Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity
Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use Confidence in Results With Data Integrity 2 Make the World Healthier With the LC-MS Tests You Run Confidence in Test Results With Data
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data
Low cost ICP-OES analysis high quality data The NEW Thermo Scientific icap 7000 Series ICP-OES provides low cost multi-element analysis for measuring trace elements in a diverse sample range. The instrument
Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides
The Integrated Lab Connected Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides NOVA View Reduces costs with automation efficiencies
Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions
Bio-Rad Laboratories QC data management solutions QC Data Management Solutions Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions Bio-Rad Laboratories QC data management
Thermo Scientific VersaTREK. Automated Microbial Detection System. Value through versatility, flexibility and. excellence in recovery
Thermo Scientific VersaTREK Automated Microbial Detection System Value through versatility, flexibility and excellence in recovery The ultimate in versatility: four tests, one platform Faster results,
510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY
510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY A. 510(k) Number: k103555 B. Purpose for Submission: New submission C. Measurand: Platelet aggregation D. Type of Test: Platelet aggregometer
endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.
One platform endless possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success. products applications software services Agilent 2100 bioanalyzer Applied
ab176915 StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections
ab176915 StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections This product is for research use only and is not intended for diagnostic
Featuring fast rotor exchanges with AUTO-LOCK
Thermo Scientific Sorvall T1 Centrifuge Series Versatility, convenience and value for routine applications Featuring fast rotor exchanges with AUTO-LOCK Versatility, convenience and value for routine applications
Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma
Mouse Insulin ELISA For the quantitative determination of insulin in mouse serum and plasma Please read carefully due to Critical Changes, e.g., Calculation of Results. For Research Use Only. Not For Use
ab185915 Protein Sumoylation Assay Ultra Kit
ab185915 Protein Sumoylation Assay Ultra Kit Instructions for Use For the measuring in vivo protein sumoylation in various samples This product is for research use only and is not intended for diagnostic
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
Smart. Scalable. Simple.
Thermo Scientific Wireless Monitoring Solution Smart. Scalable. Simple. providing the protection you need with the simplicity you deserve Thermo Scientific Wireless Monitoring Solution Optimized Sample
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
An important first step in identifying those at risk for Cardiovascular disease The Accutrend Plus system: from the makers of the ACCU-CHEK and
An important first step in identifying those at risk for Cardiovascular disease The Accutrend Plus system: from the makers of the ACCU-CHEK and CoaguChek systems Cardiovascular disease: the #1 killer in
Expert workflow management cobas p 312 pre-analytical system The new dimension of laboratory automation
Expert workflow management cobas p 312 pre-analytical system The new dimension of laboratory automation Expert workflow management Concept Professional management of laboratory processes in terms of workflow
Meso Scale Discovery. WINDOWS is a registered trademark of Microsoft Corporation
Meso Scale Discovery M S D M S D Meso Scale Discovery, a division of Meso Scale Diagnostics, LLC. (MSD) 9238 Gaither Rd, Gaithersburg, MD 20877 Phone: 240.631.2522 Fax: 240.632.2219 email: [email protected]
Let Tecan care about your routine data calculation
Let Tecan care about your routine data calculation Magellan and i-control software for Tecan microplate readers Magellan Tracker 21 CFR Part 11 98/79/EC IVD-D From basic control to sophisticated data management
Industrial Robotics Solutions
Industrial Robotics Solutions Complete Solutions for Discovery Research Genomics Proteomics Cell Analysis Centrifugation Lab Tools Particle Characterization Bioseparation Lab Automation BR-10552A The Anatomy
Let Tecan care about your routine data calculation Magellan and i-control software for Tecan microplate readers
Let Tecan care about your routine data calculation Magellan and i-control software for Tecan microplate readers Magellan Tracker 21 CFR Part 11 98/79/EC IVD-D i-control & Magellan From basic control to
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Human Luteinizing Hormone (LH) Custom Kit
Human Luteinizing Hormone (LH) Custom Kit 18089-v2-2015Jan 1 MSD Toxicology Assays Human Luteinizing Hormone (LH) Custom Kit This package insert must be read in its entirety before using this product.
Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2
Uscn Life Science Inc. Wuhan Website: www.uscnk.com Phone: +86 27 84259552 Fax: +86 27 84259551 E-mail: [email protected] ELISA Kit for Human Prostaglandin E1(PG-E1) Instruction manual Cat. No.: E0904Hu
Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment
Thermo Scientific Capitol Vial Drugs of Abuse Products The tools to create and maintain a safe and drug free environment Drugs of Abuse Specimen Collection We are a world leading manufacturer of Drugs
The EliA System Time for the essentials Cost efficient and flexible A boost in service for your laboratory and your clinicians
CCP The EliA System Time for the essentials completely automated (true walk-away, overnight runs) easy instrument management by Phadia Data Manager (IDM) software barcode-reader protocols, QC and raw data
TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet
TargetQuan 3 Software Leading the way in regulatory POPs quantification Bullet Bullet Bullet Leading the way in regulatory POPs quantification Analyse Samples Open Sequence Process Sequence Analyse Samples
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07
Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07 TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Procedure Overview... 2 Kit Contents, Storage and Shelf Life... 3
GC-xt. The most flexible GC /GC-MS liquid sample injector
GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep
Guidance for Industry
Guidance for Industry Q2B Validation of Analytical Procedures: Methodology November 1996 ICH Guidance for Industry Q2B Validation of Analytical Procedures: Methodology Additional copies are available from:
HBV Quantitative Real Time PCR Kit
Revision No.: ZJ0002 Issue Date: Aug 7 th, 2008 HBV Quantitative Real Time PCR Kit Cat. No.: HD-0002-01 For Use with LightCycler 1.0/LightCycler2.0/LightCycler480 (Roche) Real Time PCR Systems (Pls ignore
Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH
YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH Fast and Accurate: The YSI Gold Standard YSI has earned a reputation as the Gold Standard in bio-analytical
cobas 6500 urine analyzer series Fully automated urine work area on a modular platform
cobas 6500 urine analyzer series Fully automated urine work area on a modular platform cobas 6500 urine analyzer series Fully automated urine work area on a modular platform cobas 6500 urine analyzer series
QuickTiter Hepatitis B Surface Antigen (HBsAg) ELISA Kit
Product Manual QuickTiter Hepatitis B Surface Antigen (HBsAg) ELISA Kit Catalog Numbers VPK-5004 VPK-5004-5 96 assays 5 x 96 assays FOR RESEARCH USE ONLY Not for use in diagnostic procedures Introduction
Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.
K-ASSAY Mouse IgM ELISA For the quantitative determination of IgM in mouse biological samples Cat. No. KT-407 For Research Use Only. 1 Rev. 072309 K-ASSAY PRODUCT INFORMATION Mouse IgM ELISA Cat. No. KT-407
History of Innovation
1 History of Innovation Only Immucor consistently delivers the next-generation of blood bank automation to labs worldwide ABS HV Galileo NEO 1998 1999 2004 2007 2010 ABS2000 ABS Precis Echo 2 Innovation
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry BY GHULAM A. SHABIR Introduction Methods Validation: Establishing documented evidence that provides a high
Creatine Kinase Activity Assay Kit (Colorimetric)
ab155901 Creatine Kinase Activity Assay Kit (Colorimetric) Instructions for Use For the sensitive and accurate measurement of Creatine Kinase activity in various samples. This product is for research use
Mouse krebs von den lungen 6 (KL-6) ELISA
KAMIYA BIOMEDICAL COMPANY Mouse krebs von den lungen 6 (KL-6) ELISA For the quantitative determination of mouse KL-6 in serum, plasma, cell culture supernatants, body fluid and tissue homogenate Cat. No.
Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM
Inform II BLOOD GLUCOSE MONITORING SYSTEM Quick Reference Guide for Healthcare Professionals 2 Table of Contents Important... 4 General Information... 6 ACCU-CHEK Inform II Meter...10 How to Perform Patient
EXACTAMIX Compounding. Systems for Specialty Pharmacies
EXACTAMIX Compounding Systems for Specialty Pharmacies EXACTAMIX Compounding Systems from Baxter Healthcare Corporation are an advanced solution for multi-ingredient compounding. Produce a typical 3L
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Catalog No: E0479r 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH
FT-NIR for Online Analysis in Polyol Production
Application Note: 51594 FT-NIR for Online Analysis in Polyol Production Key Words Acid Number Ethylene Oxide FT-NIR Hydroxyl Value Polyester Polyols Abstract Hydroxyl value and other related parameters
Performance Qualification of an Automated Plate Washer Using the Artel MVS
Performance Qualification of an Automated Plate Washer Using the Artel MVS Kevin Khovananth, Tanya Knaide, Keith Albert ARTEL Abstract The purpose of this application note is to demonstrate the ability
73 Series Spectrophotometers
73 Series Spectrophotometers The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system
Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software
Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software Frank Tontala, Thermo Fisher Scientific, Germering, Germany Technical Note 708 Key Words Chromeleon Chromatography Data System,
Spectrophotometer - Milton Roy Spectronic 21D or equivalent.
3M COMPANY OCCUPATIONAL HEALTH AND ENVIRONMENTAL SAFETY DIVISION DETERMINATION OF FORMALDEHYDE VAPORS IN AIR USING 3M 3721 FORMALDEHYDE MONITORS May, 2002 SCOPE This procedure covers the method of collecting
HumaStar 100 HumaStar 200
HumaStar 100 HumaStar 200 Marketing material Key advantages Competition Product features Rev. 4 22.05.2014 How to use this presentation? How to use this presentation? This presentation has not only been
Quality Forward. UniCel DxI Access Immunoassay Systems
Quality Forward CONSISTENCY Forward LAB FORWARD UniCel DxI Access Immunoassay Systems When it comes to immunoassay testing, mid- to high-volume laboratories have specific needs:» Exceptional productivity»
Hidex Sense. Hidex Triathler Multi-technology Microplate Reader. Hidex AMG. Consumables. Hidex 300 SL. www.lablogic.com.
Service and Support Users of our systems can benefit from our comprehensive, fully inclusive service and support. We provide complete service and support for all of our customers to give reassurance that
IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.
IgM ELISA For the quantitative determination of IgM in human serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Please read carefully due to Critical Changes, e.g., Calibrator
Thermo Scientific Sorvall T3 and G3 Centrifuge Series. Capacity, reliability and performance for routine applications
Thermo Scientific Sorvall T3 and G3 Centrifuge Series Capacity, reliability and performance for routine applications Capacity, reliability and performance for routine applications The Thermo Scientific
USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY
USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY Breakout Session 3B Tuesday, May 1 8:30 10 am James Blackwood, MS, CLSI David D. Koch, PhD, FACB, DABCC, Pathology & Laboratory
Human Free Testosterone(F-TESTO) ELISA Kit
Human Free Testosterone(F-TESTO) ELISA Kit Catalog Number. MBS700040 For the quantitative determination of human free testosterone(f-testo) concentrations in serum, plasma. This package insert must be
Hamilton Verso. Medium to Large-Capacity Automated Sample Storage
Hamilton Verso Medium to Large-Capacity Automated Sample Storage Effortless sample management Quickly and easily manage your samples with Hamilton s latest storage platform. Automation That Adapts to You
The GeneAmp PCR System 9700. Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700
The GeneAmp PCR System 9700 Results you can trust. A PCR platform you can grow with. GeneAmp PCR System 9700 The GeneAmp PCR System 9700 fits your lab bench, your applications and your budget. The GeneAmp
Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u
Application Note USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u Summary A regeneration study of MEP HyperCel mixed-mode sorbent was conducted
Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis
Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for
Amino Acid Analyzer L-8900
Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
Fixed and Adjustable Spacing Electronic Pipettes
viaflo Fixed and Adjustable Spacing Electronic Pipettes viaflo Electronic Pipettes All viaflo pipettes function as repeaters, mixers, serial dilutors, manual pipettes, handheld sample processors and more!
-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!
-86 C Freezer Accessories New Brunswick Freezer Accessories A wide selection of racks, monitoring systems and more! A Wide Range of Accessories The Perfect Complement for Your Ultra-Low Temperature Freezer
Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method
Simultaneous Quantitation of 4 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method Xiang He and Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 76 Key Words TSQ Quantum Access
Thermo Scientific Heraeus Cryofuge Centrifuges Large volume refrigerated centrifuges for practical work in blood banks and biotechnology.
Thermo Scientific Heraeus Cryofuge Centrifuges Large volume refrigerated centrifuges for practical work in blood banks and biotechnology. Part of Thermo Fisher Scientific Thermo Scientific Heraeus Cryofuge
Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare
Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare HEALTHCARE SUPPLYSIDE SOLUTIONS Focused on your unique needs for managing assets, costs, and suppliers Part of Thermo Fisher Scientific
Who We Are. Denis Thiery Chairman and Chief Executive Officer
Who We Are Denis Thiery Chairman and Chief Executive Officer Founded in 1924, Neopost has grown to become a global leader in mailing solutions and a major player in digital communications and shipping
Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit
Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Catalog No. CSB-E15852c (96T) This immunoassay kit allows for the in vitro quantitative determination of canine CK-MB concentrations in serum and plasma.
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can
Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy
Determining the Quantity of Iron in a Vitamin Tablet Computer 34 As biochemical research becomes more sophisticated, we are learning more about the role of metallic elements in the human body. For example,
Highly specific and sensitive quantitation
PRODUCT ULLETIN SYR Select Master Mix SYR Select Master Mix Highly specific and sensitive quantitation SYR Select Master Mix offers advanced performance at an affordable price. SYR Select Master Mix is
How To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations
The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PST in mouse tissue homogenates and other biological fluids.
FOR IN VITRO AND RESEARCH USE ONLY NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES SEB268Mu 96 Tests Enzyme-linked Immunosorbent Assay Kit For Phenol Sulfotransferase (PST) Organism Species: Mus musculus
Thermo Scientific Sensititre. Susceptibility and Identification System. Customizable testing solutions. maximum performance
Thermo Scientific Sensititre Susceptibility and Identification System Customizable testing solutions maximum performance True MIC results the key to battling resistance The Thermo Scientific Sensititre
BR-10150B. Bringing power and flexibility down to size. BIOMEK NX LABORATORY AUTOMATION WORKSTATION
BR-10150B Bringing power and flexibility down to size. BIOMEK NX P LABORATORY AUTOMATION WORKSTATION Small footprint Easy fit on standard lab benches Many configurations to suit application needs Biomek
Agilent Television Power Consumption Testing. Application Note
Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,
Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)
Application Note 340 Determination of Fat in Dried Milk Products INTRODUCTION Many extraction techniques for the determination of fat in food are labor-intensive or require long extraction times. The Roese-Gottlieb
Echo. Compact Immunohematology automation. Echo is designed to bring the benefits of automation to labs of all sizes and volumes.
Echo Compact Immunohematology automation Echo is designed to bring the benefits of automation to labs of all sizes and volumes. Transfuse Transplant Transform a life Echo Instrument Map A D B C E I want
Image Lab Software for the GS-900 Densitometer
Image Lab Software for the GS-900 Densitometer Quick Start Guide Catalog # 170-9690 Bio-Rad Technical Support For help and technical advice, please contact the Bio-Rad Technical Support department. In
A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS
A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS Kent W. Warnken, Thermo Fisher Scientific, USA Patrick Messina, Quest Diagnostics,