Supercritical fluid chromatography method for the systematic toxicology analysis of cannabinoids

Similar documents
Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Analytical Test Report

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Tamsulosin Hydrochloride Capsules

Protocol: HPLC (amino acids)

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Opiates in Urine by SAMHSA GC/MS

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

How To Test For Contamination In Large Volume Water

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

SUCRALOSE. White to off-white, practically odourless crystalline powder

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Analysis of Vegetable Oils by High Performance Liquid Chromatography

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

International Journal of Pharma and Bio Sciences V1(2)2010

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Oasis HLB Cartridges and 96-Well Plates

Journal of Chemical and Pharmaceutical Research

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

ERDOSTEINE - MONOGRAPH.

A Complete Solution for Method Linearity in HPLC and UHPLC

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

An In-Gel Digestion Protocol

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

The basic division explosives for forensic purposes is shown in Fig. 1

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

High Performance Thin Layer Chromatographic Method for Estimation of Cefprozil in Tablet Dosage Form

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Appendix 5 Overview of requirements in English

Research Article. Stress study and estimation of a potent anticoagulant drug rivaroxaban by a validated HPLC method: Technology transfer to UPLC

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Chemical analysis service, Turner s Green Technology Group

High-Throughput 3-D Chromatography Through Ion Exchange SPE

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

PVV Satyanaryana et al., IJSID, 2012, 2 (1), International Journal of Science Innovations and Discoveries

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

Purification of reaction mixtures using flash chromatography.

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

TIANquick Mini Purification Kit

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Peptide synthesis, radiolabelling and radiochemical analysis

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

SCREENING FOR THE PRESENCE OF PARA-METHYLTHIOAMPHETAMINE IN URINE BY SOME COMMERCIAL IMMUNOASSAYS AND CONFIRMATION BY GC/MS

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

High performance thin layer chromatographic method for estimation of deflazacort in tablet

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

FATAL INTOXICATION BY CIBENZOLINE (CIPRALAN )

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Improved Method for the Analysis of 31 Drugs of Abuse in Oral Fluid samples using the Thomson extreme FV by LC-MS/MS

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation

Determination of Tricyclazole in Water Using Solid Phase Extraction and Liquid Chromatography

Analysis of Various Vitamins in Multivitamin Tablets

International Journal of Research and Reviews in Pharmacy and Applied science.

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

How To Use An Acquity Qda Detector

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

Transcription:

Electronic Supplementary Material (ESI) for Analytical Methods. This journal is The Royal Society of Chemistry 2015 Supercritical fluid chromatography method for the systematic toxicology analysis of cannabinoids and their metabolites R. Geryk a, M. Švidrnoch b, A. Přibylka b, K. Kalíková a, V. Maier* b and E. Tesařová a Supporting information Experimental S1 Instrumentation All SFC experiments were carried out on an Agilent 1260 Infinity Analytical SFC System (Waldbronn, Germany). The system consists of the following modules: Agilent 1260 Infinity SFC Control Module for CO 2 pre- and post-conditioning; Agilent 1260 Infinity SFC Binary Pump; Agilent 1260 Infinity degasser and autosampler; Agilent 1260 Infinity Column Compartment and Agilent 1260 Infinity Diode Array Detector with high pressure SFC flow cell. The system was controlled by Agilent OpenLab software. The Zorbax Rx-SIL column (150 mm x 4.6 mm i.d.), with particle size of 5 µm was obtained from Agilent Technologies (Waldbronn, Germany). Centrifuge Centro-8 was purchased from Letslab (Barcelona, Spain). Material and methods The carbon dioxide (CO 2, 4.8 laser, used for SFC) was purchased from SIAD (Prague, Czech Republic). Acetonitrile (ACN, Chromasolv, gradient grade, for HPLC, 99.9%), methanol (MeOH, LC-MS Ultra Chromasolv, 99.9%), propane-2-ol (IPA, Chromasolv, for HPLC, 99.9%) and β-glucuronidase (Type B-10, 10,000 units/mg) were supplied by Sigma-Aldrich (St. Louis, USA). Sodium acetate (CH 3 COONa, 99%) and ammonium acetate (CH 3 COONH 4, 98-100%) were purchased from Lachema (Brno, Czech Republic). Chloroform (CHCl 3, p.a.) was supplied by IPL (Uherský Brod, Czech Republic) and hydrochloric acid (HCl, 36%) was purchased from Analytika (Prague, Czech Republic). The deionized water was prepared by a water purification system 18 MΩ, Millipore (Molsheim, France). Solid-phase extraction cartridges, Supel -Select SCX SPE Tube (1 ml x 30 mg), were supplied by Agilent Technologies (Waldbronn, Germany). The analytes, AM-2201, AM-2201 M1, cannabidiol (CBD), JWH-018 6-hydroxyindole, JWH-018 N-(4-hydroxypentyl), JWH-018 N-pentanoic acid, JWH-019 5-hydroxyindole, JWH-019 N-(6- hydroxyhexyl), JWH-073, JWH-073 5-hydroxyindole, JWH-073 6-hydroxyindole, JWH-200, JWH-200 4-hydroxyindole, JWH-210 N-(5-carboxypentyl), JWH-250, RCS-4 N-4-hydroxypentyl and THC were acquired from LGC Standards (Teddington, United Kingdom). Separation conditions The MPs composed of supercritical CO 2 containing ACN, MeOH or IPA as OMs were used for separation of the mixture of THC, CBD and a wide group of the SCs and their metabolites. The method optimization was performed to improve separation by fine tuning of the MP (the type and amount of the OM were considered) and by adjusting the flow rate, temperature and BP. The optimized conditions were as follows: Zorbax Rx-SIL column (150 mm x 4.6 mm i.d.), with particle size of 5 µm, MP composed of CO 2 /ACN 93/7 (v/v), flow rate 2.5 ml/min, column temperature 40 C, BP 95 bars and UV detection at 210 nm. The injection volume was 5 µl. All measurements were performed in triplicates. The void volume was determined using the solvent peak. The identification of analytes was carried out by spiking with standards and by comparison of the DAD spectra using the wavelengths in the range from 200 nm to 400 nm. The detection wavelength used was 210 nm because the majority of the studied analytes exhibited absorption maximum at the given wavelength.

Sample extraction The salting out protocol was as follows: To 100 µl of spiked urine was added 10 µl of HCl (36%) and 200 µl of ACN. The mixture was mixed by vortexing for 10 s. Then 50 µl of CH 3 COONH 4 solution, as salting-out reagent (concentration 10 M), was added and vortexed for 10 s. The samples were centrifuged at 10,000 rpm for 3 minutes in microcentrifuge tubes. From the upper organic layer, 200 µl were removed and transferred to a clean vial. The organic phase was evaporated by nitrogen stream. The dry residue was dissolved in 100 µl MeOH. In the case of real sample, to 1.0 ml of urine was added 100 µl HCl (36%) and 2.0 ml ACN. The mixture was mixed by vortexing for 10 s. Then 500 µl of CH 3 COONH 4 solution (10 M) was added and vortexed for 10 s. The sample was centrifuged at 10,000 rpm for 3 minutes. From the upper organic layer, 200 µl were removed and transferred to a clean vial. The organic phase was evaporated by nitrogen stream. The dry residue was dissolved in 20 µl MeOH. Urine sample obtained from a patient after intoxication (smoking of herbal blend containing JWH-073) was enzymatically hydrolyzed by β-glucuronidase and extracted. 10 ml of urine (either blank urine or urine obtained from intoxicated patient), 6 ml of 2 M CH 3 COONa solution, ph 4.50, and 2 ml of β-glucuronidase (about 10,000 units/mg) were mixed and heated at 60 C for 1 hour. After hydrolysis the metabolites were extracted using the same extraction procedure as described above. Standard and calibration samples preparation Drug free human urines were obtained from 8 healthy volunteers (of different sex and age). The urine samples were centrifuged at 3000 rpm for 10 min and filtered through 0.45 µm nylon membrane. All these samples obtained from healthy volunteers were analyzed prior to their use for verification of drug-free status (negative urine). Stock solutions of each analyte were prepared at a concentration of 1 mg/ml using MeOH as solvent and then diluted with MeOH to appropriate concentration. The samples for calibration were prepared in negative urine at the appropriate concentrations.

Figure S1. Chemical structures of the studied analytes.

Table S1. Precision data expressed as intra-day and inter-day repeatability RSD% of retention times (t R ) and peak areas (A). Analytes Intra-day RSD% Inter-day (3 days) RSD% t R A t R A 3.0 10.0 3.0 10.0 THC 0.01 0.01 0.01 0.65 1.61 2.84 0.01 2.19 CBD 0.01 0.01 0.01 0.91 1.31 1.67 0.01 1.69 JWH-250 0.01 0.01 0.01 0.24 1.57 2.09 0.02 3.39 JWH-073 0.02 0.03 0.01 0.33 2.18 2.94 0.02 3.95 AM-2201 0.02 0.02 0.01 0.93 3.82 2.62 0.02 4.26 JWH-019 5- hydroxyindole 0.02 0.01 0.01 0.86 3.15 3.11 0.01 3.99 JWH-073 5- hydroxyindole 0.01 0.01 0.01 0.40 3.41 1.86 0.01 4.59 JWH-018 6- hydroxyindole 0.03 0.02 0.01 0.61 1.40 3.57 0.04 1.94 JWH-073 6- hydroxyindole 0.02 0.02 0.01 0.42 0.95 2.56 0.03 3.14 JWH-210 N-(5- carboxypentyl) 0.02 0.02 0.01 0.17 1.19 2.36 0.03 1.39 JWH-018 N- pentanoic acid 0.02 0.02 0.01 3.17 1.46 3.83 0.07 2.06 AM-2201 M1 0.02 0.02 0.07 0.66 1.52 3.71 0.03 6.58 RCS-4 N-(4- hydroxypentyl) 0.02 0.02 0.01 0.12 4.65 3.04 0.04 5.98 JWH-018 N-(4- hydroxypentyl) 0.12 0.15 0.06 0.22 2.42 1.42 0.15 6.35 JWH-019 N-(6- hydroxyhexyl) 0.10 0.10 0.10 0.45 5.12 3.82 0.15 6.30 JWH-200 0.13 0.16 0.13 0.53 1.91 2.24 0.18 3.74 JWH-200 4- hydroxyindole 0.10 0.15 0.07 0.37 2.57 1.11 0.19 3.87 Table S2. Chromatographic data of blank urine sample spiked with μg/ml working solution of analytes under optimized experimental conditions. MP composition: CO 2 /ACN 93/7 (v/v); flow rate

2.5 ml/min; column temperature 40 C; 95 bars as BP; UV detection at 210 nm, injection volume 5 μl, t R ; retention time, k; retention factor, R 1/2 ; resolution. Analytes t R [min] k R 1/2 THC 1.80 1.22 CBD 2.05 1.53 2.87 JWH-250 2.50 2.08 4.63 JWH-073 2.79 2.44 2.77 AM-2201 3.40 3.20 4.99 JWH-019 5-hydroxyindole 4.89 3 8.71 JWH-073 5-hydroxyindole 5.26 5.48 1.83 JWH-018 6-hydroxyindole 6.68 7.24 6.36 JWH-073 6-hydroxyindole 7.04 7.68 1.41 JWH-210 N-(5-carboxypentyl) 7.41 8.14 1.32 JWH-018 N-pentanoic acid 8.12 9.01 2.25 AM-2201 M1 8.98 10.08 2.77 RCS-4 N-(4-hydroxypentyl) 9.37 10.56 1.36 JWH-018 N-(4-hydroxypentyl) 10.31 11.72 3.13 JWH-019 N-(6-hydroxyhexyl) 11.19 12.79 2.45 JWH-200 11.82 13.57 1.65 JWH-200 4-hydroxyindole 12.47 14.38 1.60

Table S3. Linearity and sensitivity parameters (n = 3, six point calibration method). Analytes Regression line Sensitivity Linearity range [] Slope [mau s ml /µg] Intercept [mau s] Coefficient of determination, R 2 LOD [] LOQ [] THC 0.5-20.0 6.982 1.056 0.9997 0.15 0.50 CBD 0.5-20.0 6.124 1.075 0.9998 0.15 0.50 JWH-250 0.5-20.0 4.758-0.056 0.9992 0.15 0.50 JWH-073 0.5-20.0 12.745-0.165 0.9993 0.15 0.50 AM-2201 0.5-20.0 9.894 0.296 0.9995 0.15 0.50 JWH-019 5-hydroxyindole 1.0-20.0 7.957 0.311 0.9996 0.17 0.57 JWH-073 5-hydroxyindole 1.0-20.0 13.137-0.726 0.9996 0.18 0.60 JWH-018 6-hydroxyindole 1.5-20.0 7.325 0.523 0.9997 0.35 1.17 JWH-073 6-hydroxyindole 1.0-20.0 7.985 0.277 0.9995 0.25 0.83 JWH-210 N-(5-carboxypentyl) 1.5-20.0 6.458 0.952 0.9995 0.33 1.10 JWH-018 N-pentanoic acid 1.5-20.0 9.428 0.034 0.9997 0.35 1.17 AM-2201 M1 1.0-20.0 11.485 0.498 0.9996 0.26 0.87 RCS-4 N-(4-hydroxypentyl) 2.0-20.0 4.812 2.058 0.9989 0.50 1.67 JWH-018 N-(4-hydroxypentyl) 1.5-20.0 13.973-1.519 0.9997 0.31 1.03 JWH-019 N-(6-hydroxyhexyl) 2.0-20.0 8.258 0.489 0.9995 0.52 1.73 JWH-200 1.5-20.0 10.078-0.989 0.9996 0.36 1.20 JWH-200 4-hydroxyindole 2.0-20.0 8.210 2.451 0.9980 0.52 1.73

Table S4. Mean recovery data. Analytes Recovery% RSD% 10.0 10.0 THC 124.3 87.7 2.90 4.75 CBD 108.1 77.2 1.57 2.76 JWH-250 99.1 91.9 3.45 1.86 JWH-073 100.3 78.1 5.38 2.00 AM-2201 103.0 75.5 4.27 1.84 JWH-019 5-hydroxyindole 106.5 71.2 3.99 3.39 JWH-073 5-hydroxyindole 100.3 75.6 4.59 0.90 JWH-018 6-hydroxyindole 96.2 89.7 1.94 3.43 JWH-073 6-hydroxyindole 98.8 74.6 3.14 2.49 JWH-210 N-(5-carboxypentyl) 76.6 93.8 1.39 1.66 JWH-018 N-pentanoic acid 82.1 86.4 2.06 4.41 AM-2201 M1 97.1 85.4 6.66 3.44 RCS-4 N-(4-hydroxypentyl) 96.2 75.2 4.65 2.75 JWH-018 N-(4-hydroxypentyl) 111.4 92.6 6.35 4.41 JWH-019 N-(6-hydroxyhexyl) 108.4 96.9 2.03 4.94 JWH-200 74.2 80.9 3.74 4.43 JWH-200 4-hydroxyindole 91.3 89.5 2.57 4.29 The recoveries were calculated as the ratio of blank urine samples spiked with all analytes before and after the extraction step.