Top quality furnaces packed with features!

Similar documents
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Commercial Gas Furnace Upflow

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL MANUAL GDS8 & GHS8

F9MXE. Product Specifications

Cooling Capacity CFM in. w.c. (125 Pa)

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

G9MXE. Product Specifications

Diagnostics for Mobile Homes: HVAC

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

OIL FURNACES. Clean, Comfortable Oil Heat From

Your safety and the safety of others are very important.

SL280UHV SERIES GAS FURNACE WARNING

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

E2 Series Electric Furnaces

High efficiency, cast-iron gas boiler

Installation Instructions

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Glossary of Heating, Ventilation and Air Conditioning Terms

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

INSTALLATION INSTRUCTION

UDSA - UDSBD unit heater

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

HEAVY DUTY STORAGE GAS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Fossil fuel heating equipment

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Innovent LASER Packaged Fresh Air Conditioning Units

Your safety and the safety of others are very important.

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Portable Air Conditioner

Air Conditioning Sign-Off Sheet

Operator: Save these instructions for future use!

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

M1 Series. M1G and M1M Furnaces. Service Manual

ASX7-4-IOM-7 J

Owners Manual/Installation Instructions

EFFECTIVE OCTOBER Atwood Furnaces. and Digital Thermostats

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

How To Install An Evaporator Coil

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

K6C Summit Multi Oil Warm Air Furnace SAVE THESE AND BURNER INSTRUCTIONS FOR REFERENCE

Greensource iseries HY Model Unitary Air Handler/Fan Coil

NAVIEN AMERICA INC FITCH AVENUE

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Cooktop Low-Profile Ventilation Hoods

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

PMI-IF-H High Efficiency Gas Heat Units

Cooling/Heat Pump Convertible Air Handlers

GCS16 GCS20 WARNING CAUTION

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

THREE. Heating and Cooling

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Commercial Gas Water Heaters

air conditioners how to choose a cooling system

Evaluate, Clean, and Tune Guidance

Heating, Ventilation and Air Conditioning

USER S INFORMATION MANUAL

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Originators of the Flexible Water Tube design

INSTALLATION MANUAL RESIDENTIAL GAS FURNACE. MODELS: TG9S*MP, GG9S*MP (95.5% AFUE Single Stage Multi-position) LIST OF SECTIONS LIST OF FIGURES

INSTALLATION INSTRUCTIONS SLP98UHV DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE UPFLOW / HORIZONTAL AIR DISCHARGE

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Cased/Uncased Coils For Gas And Oil Furnaces

HV AC CODE CHECKLISTS

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Commercial Gas Water Heaters

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

Across America. Wood & Coal Brochure

Commercial Gas Water Heater

ARMSTRONG AIR HEAT PUMPS

BVCAA inc HVAC Service Bid Sheet Item Description. Materials Labor Total 3/24/2015

Condensing Boiler Efficiency

Installer s Guide 18-AH39D1-13

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

The Savannah Steel Series Wood Burning Stoves and Inserts

TYPE. MODEL B3200 Roof-Top Air Conditioner used with Mechanical Air Distribution Box INSTALLATION & OPERATING INSTRUCTIONS Air Conditioner

Summit Series Single Section and Double Section Homes

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Energy Efficiency in Industrial HVAC Systems

Energy Efficiency HOSPITALITY.

FBQ. DC Duct Heat Pump or Cooling Only

Development Services City of Lawrence, KS

Transcription:

Top quality furnaces packed with features! 60,000 to 90,000 BTUH Clean, Efficient Gas Heat Multi-Speed Blower A/C Ready Up to 5 Tons MGD-B SERIES GAS FURNACES FOR MANUFACTURED HOMES

TECHNICAL INFORMATION GAS FURNACES ARE COMPACT, EFFICIENT AND A/C READY These downflow furnaces are specially designed for Model No. HP Blower installation in manufactured housing. Three heat MGD60-E3B 1/3 3 speed, 1200 cfm capacity and two blower choices handle heating MGD70-E3B 1/3 3 speed, 1200 cfm and heating/cooling (2 to 5 tons) in any climate. All MGD77-E3B 1/3 3 speed, 1200 cfm blowers are multi-speed to adjust airflow to the home MGD90-E3B 1/3 3 speed, 1200 cfm for quiet operation, high efficiency, and comfort. Units come with sealed combustion venting and can be MGD60-E5B 3/4 4 speed, 1600 cfm installed with zero clearance to construction. MGD70-E5B 3/4 4 speed, 1600 cfm MGD77-E5B 3/4 4 speed, 1600 cfm MGD90-E5B 3/4 4 speed, 1600 cfm SPECIFICATIONS Model No. MDG60 MGD70 MGD77 MGD90 Input, BTUH 60,000 70,000 77,000 90,000 Output, BTUH 48,000 56,000 61,600 72,000 AFUE 80% 80% 80% 80% Ignition Type Electronic Hot Surface Air Temperature Rise, Range 40-70 o F 40-70 o F 40-70 o F 45-75 o F Blower Heat/Cool Designed Max. Outlet Air Temp. 170 o F Max. External SP (Duct) 0.03 W.C. Factory Equipped Fuel Natural Gas (L.P. Orifice Furnished) High Altitude derate 4% for each Main burner orifice change required. 1000 ft above 2000 ft See table in installation instructions or contact factory. Furnace Flue Pipe and Cap Must use RJS (sloped roof) or RJF (flat roof) Roof Jack and RJCRWN Crown Gas Connection 1/2" NFPT Electric Service 115V-1-60 Fuse or Circuit Breaker 15 Amp Thermostat Circuit 24V AC 60Hz, 40VA Filters Two 16" x 20" x 1" FEATURES AND BENEFITS Mobile furnaces fit virtually anywhere As a replacement unit for an older furnace, you ll find just the size you need with the features you want, ensuring a cost-effective installation! Four-way duct connector Unique design provides alignment flexibility and makes a leak-free gasketed connection to all manufactured home supply ducts Sealed combustion system Safe and efficient because no indoor air is used for combustion A/C ready 2 to 5 ton air conditioning capacity, select three- or four-speed blower Twin disposable filters Standard models clean the air effectively and are available everywhere Aluminized steel heat transfer tubes By extracting more heat from the flue gas, they provide heating comfort for fewer dollars

FURNACE INFORMATION AND SELECTION Furnace Dimensions: 77 1 /2 High x 19 3 /4 Wide x 25 Deep STEP ONE: Furnace Size and Blower Selection BLOWER SELECTION w/nominal CFMs & TONS @.2 ESP Model Number BTUH Input/Output -E3B -E5B MGD60 60,000/48,000 3 Speed Blower 4 Speed Blower MGD70 70,000/56,000 1240* CFM 1660* CFM MGD77 77,000/61,600 2-3.5 Tons 3-5 Tons** MGD90 90,000/72,000 1/3 HP 3/4 HP * Air ratings at high speeds with coil and filter in place. ** Recommend A/C lower speed set at MED-HI or below due to potential A-coil water blow-off. All gas furnaces set for natural gas. Furnace includes LP orifice for conversion. STEP TWO: Roof Jack and Accessory Selection based on Furnace Location & Roof Type WARNING: All units must be installed utilizing factory accessories as indicated below. DO NOT reuse existing flue components and/or accessories. Failure to comply with this! warning will invalidate certification, which may make the installation illegal and may result in unsafe operation, explosion, and/or fire or asphyxiation. ROOF JACK: Distance from FLOOR of home to where ROOF JACK meets the ROOFING MATERIAL=Dimension A These Roof Jacks MUST BE USED to complete the installation. Adjustable Height Added Part Number To Furnace Height (In.) Roof A Dimension (In.) 90-RJF1729-AL 17 to 29 Flat 94 1 /2 to 106 1 /2 90-RJF2551-AL 25 to 51 Flat 102 1 /2 to 128 1 /2 90-RJS1729-AL 17 to 29 3/12 Slope 94 1 /2 to 106 1 /2 90-RJS2551-AL 25 to 51 3/12 Slope 102 1 /2 to 128 1 /2 90-RJS3868-AL 38 to 68 3/12 Slope 115 1 /2 to 145 1 /2 90-RJS6399-AL 63 to 99 3/12 Slope 140 1 /2 to 176 1 /2 Accessories REQUIRED with Each Roof Jack 90-RJCRWN-AL Crown (Vent/Intake Cap) R75GF0001 Roof Jack Sealant Optional Roof Jack Accessories 90-TRM-RNG Ceiling Trim Ring 90-RJTRC Transit Kit 90-RJS56 5-6/12 Slope Saddle Adapter 90-OUTXT16-AL Outside Roof Jack 16 Ext-Gas 90-INSXT10-AL Inside Roof Jack 10 Ext-Gas RJS Roof Jack with high pitch roof adapter 10 L Inside Extension for RJ-Roof Jack NOTE: Field assembled joints will be visible below ceiling 16 Outside Roof Jack Extension STEP THREE: Purchase proper Duct Connector, if existing connector is unsuitable Duct Connection Adustable Style Depth Home Floor To Duct Surface Duct Connector Furnace Base 90-DCU0-01 1 to 4 86AA0013 + 87FB0005 90-DCU0-02 6 to 8 86AA0014 + 87FB0005 90-DCU0-03 8 to 12 86AA0015 + 87FB0005

FURNACE INFORMATION AND SELECTION CLEARANCES Top... 6 in. Sides... 0 in. * Back... 0 in. * Alcove front of furnace... 18 in. Closet front of furnace... 6 in. ** Duct... 0 in. Vent/Roof Jack... 0 in. * If the return air opening is below the top of the furnace, clearance to the side or rear must be 6". **See Return Air for clearances for less than 6". SELECT SEALED COMBUSTION ROOF JACK (REQUIRED) 3/12 Pitch Roof Flat-Bow Rafter Roof 87FB0005 FURNACE BASE AND 86AA001 (X) DUCT CONNECTOR FLOOR TO DUCT SURFACE DIMENSION A 86AA0013 4 1 /2 86AA0014 8 1 /4 86AA0015 12 1 /4

MGD-B SERIES FURNACES BLOWER PERFORMANCE ESP, In. W.C. DUCT 0.1 0.2 0.3 0.4 0.5 3 BLOWER 10x8, 1/3 HP, 3 Speed CFM No Coil LO 980 950 910 875 825 MED 1220 1170 1120 1065 1015 HI 1460 1400 1340 1270 1195 CFM With Coil LO 945 905 865 815 775 MED 1130 1085 1030 970 905 HI 1300 1240 1180 1105 1035 5 BLOWER 10x8, 3/4 HP, 4 Speed CFM No Coil LO 995 960 915 875 825 MED 1205 1165 1130 1090 1045 MED HI 1470 1425 1385 1345 1310 HI 1810 1765 1720 1680 1635 CFM With Coil LO 950 905 865 835 790 MED 1145 1115 1080 1035 1000 MED HI 1375 1345 1315 1280 1245 HI 1700 1660 1620 1575 1540 DIMENSIONS 25 19 3 /4 23 7 /8 11 1 /4 9 7 /8 77 1 /2 S w c i e MODEL IDENTIFICATION M G D 70 - E 3 B Manufactured Home Gas Downflow BTUH Input X1000 Electronic Hot Surface Ignition Blower 3=1/3HP, 3 Spd 5=3/4HP, 4 Spd Revision Level We offer a complete line of accessories for the MGD Series of manufactured home furnaces. Some are necessary to meet certification requirements. Some are options that may be needed depending upon the application and the geographical location of the installation. These accessories are described in detail inside this brochure. H i ( e e Solid state integrated control board Monitors flame, plus start up and shut down of blower to improve efficiency Combustion blower Provides a consistent and stable flow of air to the burner and is unaffected by outside conditions Hot surface ignition system Safe method used with high efficiency 80% AFUE models no standing pilot Attractive appearance Appliance white doors have rounded corners and plastic caps for a modern look Fully insulated cabinet Fiberglass insulation with reflective foil makes the units quiet and efficient while minimizing heat loss Coil compartment Handles coils for add-on A/C systems up to 5 tons Monoport burner Uses stainless steel and sintered metal for exceptional burner efficiency and long life Warranty 5 years on mechanical parts, 10 years on heat exchanger (see printed warranty for limitations and details) S t p a t S

COST-EFFECTIVE, EFFICIENT GAS FURNACES A PERFECT FIT FOR REPLACEMENT INSTALLATIONS Sealed combustion pipewithin-a-pipe roof jack vents combustion gases while bringing in outdoor air for increased efficiency and safety Hot surface, automatic ignition with high temp (2500 o F) silicon carbide element is not affected by extreme weather or high winds Solid state controls provide trouble-free ignition, and the programmed on-off blower achieves even room temperature for greater comfort Standard Furnace A/C ready with coil compartment The Quality Leader in Conditioning Air Heat Controller, Inc., has entered its eighth decade of providing quality products for conditioning air. Founded in 1933, the company can trace its roots to the Wingert Furnace Co. which began operations in 1907. In 1955 the company moved to a new facility in Jackson, Michigan, which remains its headquarters today. Heat Controller is known throughout the industry for efficient, reliable products and in-season availability. Whether for heating or cooling, these products meet or exceed industry standards for energy efficiency. Every unit, including our gas furnaces for manufactured home use, is built to exacting standards using quality materials and is backed by solid warranty coverage and technical support. SP 2.5M 2/13 HC-MGDB-A