60W 1Phase CliQ ll DIN Rail

Similar documents
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply

Power Supplies 3. SDN-P DIN Rail Series

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Single Output Switching Power Supply

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

PHOENIX CONTACT - 01/2007

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

TEP 200WIR Series, Watt

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

38 Series - Relay interface modules A

Redundancy Module QUINT-DIODE/40

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Industrial Power Supplies

Telephone- and leased line modem for industrial applications TD-36

38 Series - Relay interface modules A

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Maximum Input Current Vin=18V, 100% Load A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Three-phase monitoring relay CM-PFE

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

7 - Phaseo power supplies and transformers

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

STRATO LED Drivers 70W, Single output

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Safety technique. Emergency stop module BO 5988 safemaster

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RM4TG20 three-phase network control relay RM4-T - range V

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

7.5 Watt AC-DC Switch Power Supply

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Power Supplies 3. SDN-C Compact DIN Rail Series


APD / Outputs 19" DC/DC Converter, 50 Watt

AC-DC Single Output Power Module

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

PWM-60 series IP67 TRC ELECTRONICS, INC

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A Vin=24V ma

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Operating Manual UWAPS-TINY Series

Rack mounted telephone- and leased line modem for industrial applications

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Relés e Contatores de Estado Sólido SIRIUS

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Datasheet. Arrant-Light Oy. 120W DR Series

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Energy Management Energy Meter Type EM23 DIN

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Actuator-Sensor-Interface

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Easy Multifunctional Safe

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

E-STOP relays, safety gate monitors

BB800 Off-Grid Solar System

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

MasterINTERFACE 39 Series - Relay interface modules

Control Devices Catalogue. Control Devices. Preferred and Standard Products

DC/DC Converter 9 to 18Vdc and 18 to 36Vdc and 36 to 75Vdc input, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

I STAR COMPUTER CO., LTD

Digital input modules

Series AMLDL-Z Up to 1000mA LED Driver

Cross-beam scanning system to detect slim objects. 100 mm in

CompactLogix Power Supplies Specifications

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

is then retained absolutely without interruption.

WINGLIKE ELECTRONICS CO.,LTD

ST Series POWER SUPPLIES USER INSTRUCTIONS

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Transcription:

60W 1Phase CliQ ll DIN Rail Features: Ease of wire connection to terminals Comes with detachable connectors Overload, Overvoltage & Thermal protection Efficiency > 89% Power boost 150% for 3 seconds Expected life time: 10 years Redundancy: Yes (with external ORing diode) RoHS & IP20 compliant Meet Energy Star Level 5 3 years warranty Summary The new CliQ II is the latest offering from one of the world s largest power supply manufacturers - Delta. The product offers a nominal output voltage of 24 V, a wide temperature range from -20 C to +80 C and a minimum holdup time of 20 ms. The state-of-the-art design is made to withstand harsh industrial environments. The rugged, ultra-compact metal case is shock and vibration resistant according to IEC60068-2. The 60 watts DIN Rail power supply provides overvoltage, overload and thermal protection. Due to the wide input voltage range from 85 to 264 VAC, the Delta s CliQ II power supply is worldwide usable. It also comes with multiple output terminals for fast wiring and easy installation. 1/13 Rev: 00,

Technical Data Input Data (1) Nominal input voltage and frequency Voltage range Frequency Range Nominal current Inrush current limitation. I2t (+25 C) typ. Mains buffering at nominal load (typ.) Turn-on time Internal fuse Recommended backup fuse: Power circuit-breaker characteristic Leakage current Energy Star Level 60W1Ph 100-240VAC / 50-60Hz 85-264VAC (120 375 VDC) 47-63Hz 1.5A max @115VAC, 1.0A max @230VAC < 35A @ 230VAC > 20ms @ 115VAC, > 125ms @ 230VAC < 3.0sec. T 3.15 AH / 250V 6A, 10A or 16A : B < 1mA V Output Data (2) Nominal output voltage U N / tolerance 24VDC±2% Setting range of the output voltage 24-28VDC Nominal current 2.5A De-rating above +50 C > 50 C (2.5% / C) Startup with capacitive loads Max 8,000µF at 25 C Max. power dissipation idling / nominal load approx. 7.4W Efficiency > 89% typical. Residual ripple / peak switching (20 MHz) (at nominal values) < 50mV / < 150mVpp. Can be connected in parallel for redundancy and increased capacity YES with ORing Diode or Redundancy module Surge voltage protection against internal surge voltages YES Certification/Standards Electrical equipment of machines Safety transformers for switched-mode power supply units Electrical safety (of information technology equipment) Industrial Control Equipment IEC60204-1 (overvoltage category III) Electronic equipment for use in electrical power Installations Safety entry low voltage Safe isolation DIN.VDE 0100-410 Protection against electric shock DIN 57100-410 Protection against shock currents, basic requirements for protective VDE 0106-101 separation in electrical equipment Limitation of mains harmonic currents DIN57100-410 TUV BAUART to EN60950-1, UL/C-UL recognized to UL60950-1, CSA C22.2 No. 60950-1, CB scheme to IEC60950-1 UL / C-UL Listed UL508 and CSA C22.2 No. 107.1-01, CSA to CSA C22.2 No.107.1-01 (file no. 181564) EN50178 / IEC62103 PELV (EN60204), SELV (EN60950) 2/13 Rev: 00,

General Data Isolation voltage: Input / output Input / PE output / PE Degree of protection Class of protection MTBF Type of housing Dimensions (L / W / H ) Weight STATUS Indicator LED (6) DC OUTPUT OK Climatic Data Ambient temperature (Operating) Ambient temperature (Storage) Humidity at 25 C, non-condensing Vibration (Non-Operating) type test/routine test type test/routine test type test/routine test 4 KVAC / 3 KVAC 1.5 KVAC / 1.5 KVAC 1.5 KVAC / 500 VAC IP20 Class I with PE connection > 1,000,000hrs. Aluminium (AI5052) 121mmx32mmx125mm 0.37Kg YES (GREEN LED) -20 C to 80 C (> 50 C de-rating) -25 C to 85 C < 95% RH 10Hz to 500Hz @ 30 m/ S 2 (3G peak); displacement of 0.35mm; 60min per axis for all X, Y, Z direction. in acc. with IEC 68000-2-6. Shock (in all directions) 30G (300m/S 2 ) in all directions according to IEC60068-2-27 Pollution degree 2 according to EN50178 Climatic class 3K3 according to EN 60721 In conformance with EMC guideline 89/336/EEC and low voltage directive 73/23/EEC DINRAIL 1AC / 24V DC / 2.5A (EOE11010248) EMC (electromagnetic compatibility) Immunity to interference according to EN 61000-6-2 EN 61000-4-2 1) Housing LEVEL 4 Discharge of static electricity (ESD) Contact discharge: Air Discharge: 8 KV 15 KV EN 61000-4-3 1) Housing LEVEL 3 Radiate Field Immunity Frequency/Field intensity: 80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation EN 61000-4-4 1) Fast transients (Burst): 2KV 4) EN 61000-4-5 1) Surge voltage Immunity (Surge): EN 61000-4-6 1) I/O: Conducted Immunity Frequency / U o: EN 61000-4-11 2) Voltage dips Noise emission according to EN 61000-6-3 Emitted radio interface Radio interference voltage 2KV 3) / 2KV 4) (Level 3) Level 3 0.15MHz - 80MHz / 10Vrms. Input: Main Buffering > 20ms. EN55011 (EN55022) CLASS B 5 EN55011 (EN55022) CLASS B 5 EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EN 61000 corresponds to IEC 61000 1) Criterion A: Normal operating behavior within the defined limits. 2) Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. 3) Symmetrical: Conductor to conductor. 4) Asymmetrical: Conductor to ground. 5) Class B: Area of application industry and residential. 3/13 Rev: 00,

Numbering for DIN Rail Power Supply For example: XX X XXXX XXXX X XX XX.Product Type DR DinRail XX X XXXX XXXX X XX X.Model P Power Supply XX X XXXX XXXX X XX XXXX.Voltage XX X XXXX XXXX X XX XXXX Watt 060W 120W 240W 480W 60 Watt 120 Watt 240 Watt 480 Watt XX X XXXX XXXX X XX X.Phase 1 1 Phase 3 3 Phase 024V 24 Voltage XX X XXXX XXXX X XX XX.Variation (Eg, Customer, material,etc.) BA Delta standard metal case 4/13 Rev: 00,

Block Diagrams/Connections: Block Diagram of Power Supply, 5/13 Rev: 00,

Percentage of Max Load (%) Switch Mode Power Supply Engineering Data o Derating Curve (Both of Horizontal and Vertical) Model: 110% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% -20-10 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) Note: 1. Do not use the device in areas outside of the shaded portion shown in the above graph. Internal parts may gradually deteriorate and become damaged. 2. Based on the above graph, if the ambient temperature is greater than 50 C, the output capacity has to be reduced by 2.5% per Celsius temperature increase. If not, the device will go into over-temperature protection by switching off i.e. device will go into bouncing mode. It will recover when ambient temperature drops to 50 C or output capacity is reduced as recommended in the graph. 3. If the device has to be mounted in any other direction, please contact your service provider for more details. 4. In order for the device to function in the manner intended, it is also necessary to observe a lateral spacing of 2cm from other equipments. 5. Depending on the ambient temperature and output capacity of the device, the device housing can be very hot! 6/13 Rev: 00,

Mechanical drawing Device description (Fig. 1) (1) Input terminal block connector (2) Output terminal block connector (3) DC voltage adjustment potentiometer (4) DC OK control LED (green) (5) Universal mounting rail system 7/13 Rev: 00,

Overload Protection The Power Supply is provided with an overload protection (OLP) function which protects the power supply from possible damage caused by excess current. The Power Supply also has an over temperature protection (OTP) in case overload condition persists for an extended duration and is below the overload trigger point but > 100% load. Typically the overload current (I OL ) is > I SURGE (150%) output voltage will start dropping when the power supply reaches max power limit. It will go into bouncing mode when the output reaches UVLO (under voltage point). The output voltage will recover automatically when the overload condition is removed. Short Circuit Protection The Power Supply has a short circuit protection which is in line with the overload protection and activates whenever there is a short across the output voltage. It will go into bouncing mode and recovers automatically when the fault is removed. Over Temperature Protection The Power Supply has an over temperature protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher ambient operating condition at 100% load, the Power Supply will run into OTP when the ambient temperature is > 55 C. When activated, the output voltage will go into bouncing mode until the operating ambient temperature drops to 50 C or output capacity is reduced as recommended in the graph. 8/13 Rev: 00,

Overvoltage protection The Power Supply has an overvoltage protection (OVP) and is activated when the power supply feedback circuit fails. The output voltage will not be > 35V under any Line/Load and operating ambient temperature. The Power Supply does not shut down but goes into Hiccup mode (Auto-Recovery). The output voltage will recover back to 24VDC once the fault is removed. Inrush Current, Start-up Time, Output Hold-up Time Inrush Current, Inrush current is the first surge current seen on the input side when AC input is applied to the Power Supply. It is the first pulse captured. See below for the Inrush current in a typical Power Supply. Start-up Time, Start-up time is measured from the point AC input is applied to the point output voltage reaches within 90% of its set value. See below for a typical start-up time characteristic. Rise Time, Rise time is measured from the point output voltage rises from 10% to 90% of its set value. See below for a typical rise time measurement. 9/13 Rev: 00,

Hold-up Time, Hold time is the time when the AC input collapses and o/p voltage retains regulation for a certain period of time is called as hold up time. See in the picture below a typical hold up time characteristic of a power supply. The hold time is measured until the output voltage remains in regulation hence it measured until the output voltage reaches minimum regulation -2% of its set value. Output Voltage Adjust The 24VDC connection is made using the "+" and " " screw connections. At the time of delivery, the output voltage is 24VDC. The output voltage can be set from 24 to 28VDC on the potentiometer seen as Adjust on the front panel of each power supply. 10/13 Rev: 00,

Surge Load See below typical surge load capability of the power supply, the PSU is capable of delivering 3 secs of Surge load about 150% of I O max the o/p voltage can be out of regulation limits of + 5%. Dynamic Load The Power Supply is capable of dynamic output voltage load change from 10% to 90% within ±5% of regulation limits, and from 0% to 100% within ±10% of regulation limits. See picture below on the dynamic behavior of the Power Supply. 11/13 Rev: 00,

Redundancy & Parallel Operation with ORing Diode See picture below for a typical Redundant/Parallel operation using CliQ II Series Power Supplies. Power Supply Unit 1 (PSU1) and Power Supply Unit 2 (PSU2) are connected through a twin diode where Anode 1 (A1) is connected to the +Ve of PSU1 and A2 is connected to the +Ve of PSU2 and both output ground are shorted together. The output of PSU1 and PSU2 is drawn from the Cathode K of the twin diode, making the Power Supply work in Redundant/Parallel operation. Redundant Operation: When 2 Power Supplies are connected in parallel, the Power Supply with the higher output voltage will take the maximum load while the other will operate in standby mode (at no load). In case the first Power Supply fails, the second will take over the load and supplies the required power to the end system. 12/13 Rev: 00,

Parallel Operation: When 2 Power Supplies are connected in parallel, they can share the load if the following steps are taken. Step 1: Measure the output voltages at no load from A1 to Ground i.e. VA1 to Ground of PSU1 and VA2 to Ground of PSU2. If the voltages are not the same, follow Step 2. If they are the same, skip to Step 3. Step 2: Adjust the output voltages, with the help of VR on the Power Supply front panel market as ADJUST, to the same level. For e.g. if PSU1 is measuring 24.15Vdc and PSU2 is measuring 24.25Vdc, adjust the output voltage of one to be the same as the other. Step 3: Connect the Power Supply to the end system load and measure the output voltages from A1 to Ground i.e. VA1 to Ground of PSU1 and VA2 to Ground of PSU2. Ensure that the output voltages are the same even after the 2 Power Supplies are connected to load. If not, adjust them with the VR available on the front panel. A tolerance of +/-25mV would be acceptable. Note: 1. If the output voltage of any Power Supply is higher, it will take the initial load and share the maximum load. 2. If the output voltages are the same, then an equal load current sharing between the 2 Power Supplies can be achieved. 3. The ORing diode must be of an appropriate rating. The rating must be at least 4 times of the output load current and at least reverse voltage rating of 20Vrr. 4. The use of a heat sink is advised to ensure the ORing Diode does not overheat. 5. Recommended Redundancy Module: DRR-20A 13/13 Rev: 00,