electrolux oxygen central vacuum system installation manual

Similar documents
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Electrical Wiring Technical Bulletin

Cooktop Low-Profile Ventilation Hoods

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Builder Specifications for Solar Ready Homes

Guidelines for Earthquake Bracing of Residential Water Heaters

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Excerpts from the Canadian National Building Code (NBC)

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Installation Instructions ERV/PRV Downdraft Vent

DIY CABINET REFACING INSTALLATION GUIDE

TopSky DLG Installation Manual

Installation, operation and maintenance manual TX 35A

Typical Central Vacuum System Installations

Flexit Central Vacuum Cleaner

Flexit Central Vacuum Cleaner

Installation Instructions For Slider Casement Air Conditioners

Fiberstars Lighted Laminar Flow Fountain Installation Manual

2010 Residential Water Heater Replacement Check List

Installation Instructions

Portable Air Conditioner

3 IN 1 BATHROOM HEATER

Accessory Manual Ventilation Section Model Comfort Circle

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Guidelines for Earthquake Bracing Residential Water Heaters

Flue Installation. High Efficiency Condensing Boilers

Acumen Enterprises, Inc.

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

Installation Instructions

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Installation Instructions

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

DRYER VENTING SPECIFICATIONS DRYER SAFETY

AM/FM ANTENNA RELOCATION KIT

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Arapahoe County Residential Water Heater Installation and Inspection Guide

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

How To Install An Intercom Or Door Phone System For Your Home Or Business. Provided by

Installation of Rear View Camera in a 1995 Roadtrek 190 Popular

Doorbell Intercom Security System

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

HVAC Code Requirements

SHOT BLAST CABINET MODEL NO: CSB20B

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Installation Guide. Bath and Wall Surrounds SERIES B

Home Warranty Inspection Report

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

GenStore Archive Cabinet

EH-20 20m antenna. By VE3RGW

Hive Top Ventilation Shims

INFRARED QUARTZ WALL HEATER

State of Connecticut Department of Public Health RADON PROGRAM

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

Industrial Strength Rocket Launcher

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Please also see 10 golden rules for correct Saniflo installation on

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

ROOM AIR CONDITIONER INSTALLATION MANUAL

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

Utility Distribution Systems

Battery Backup Sump Pump System

Fiberstars Mini Lighted Laminar Flow Fountains

Control Box Wiring For PRSstandard Tool

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

4 Installation Requirements

Arctic Leash Instruction Manual Alaskan Products Company LLC.

DE Frame with C Series Sidelight

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

INSTALLATION OF A BAY WINDOW

DETAILED INSTALLATION GUIDE

Installation Instructions

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

Installation Instructions

39HQ Airovision Air Handling Units

Installation Guide for Artic Air 24 Volt R134A Air Conditioner

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

Air Conditioner Duct Construction & Repair

Reverse Cycle Inverter Split System Air Conditioner

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

with installation dynafact boost GAUGE this manual is for use with systems

Built to Last. Built for Beauty. Good. Solid. Logix. TM

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

October 5, 2015 Dear Client,

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

Installation Instructions

Module 3.7. Thermal bridging

Transcription:

electrolux oxygen central vacuum system installation manual

2 electrolux installation manual Contents Central Vacuum System Installation Location of the Power Unit...3 Tubing System Design...3 Location of Wall Inlet Valves...3 Typical Installation Examples...3 Installation of Wall Inlets...4 Tubing System Installation...7 VacPan Installation...8 Exhaust Blow-Out...9 Electrical Connections...10

electrolux installation manual 3 Read these instructions carefully. Installation of the central vacuum system is easy and can be performed with regular hand tools. The system can be installed both in new and existing buildings. When using a central vacuum system, it is important to make sure there is a sufficient compensation air supply. Normal ventilation ensures that there is enough compensation air. This central vacuum system is very useful, and you can enjoy it for years to come. Location of the Power Unit Place the power unit preferably in a heated area like the utility room, garage, storage room, or laundry room. If the power unit is installed in a cold storage room, the vacuum tubing and the exhaust should be insulated in order to avoid condensation. In buildings with two or more stories, it is recommended to always place the power unit on the lowest. If the equipment is placed on the upper, the power unit must be more powerful so that even the heaviest dust particles can be vacuumed and transferred into the dust container. When selecting the installation location, it is recommended that you ensure that the placement does not disturb your neighbors or interfere with your own comfort and activities. Make sure that there is a outlet nearby for connection to the electrical network. If you are not sure about the placement, contact your local building inspector or fire authority for more information. Location of Wall Inlet Valves Wall inlet valves can be placed in the or in the. Place the inlets preferably so that you can reach every corner of the room with a vacuum hose that is 27 to 33 feet long (8m to 10m). There is a utility valve in the power unit, which allows you to conveniently clean the space where the vacuum is located and close-by areas, thus eliminating the need to install another inlet valve and tubing route. Marking the Placement of the Inlet Valves Mark the installation points of the inlet valves in the layout drawings using wire of the same length as the actual vacuum hose. When using drawings scaled 1:1000 the wire length is 3 1/4 (8 cm), and when using drawings scaled 1:50 the wire length is 6 1/2 (16 cm). Suitable places for inlet valves are entrance halls, hallways, etc. valve door Floor valve valve Typical Installation Examples power unit exhaust valve hose coverage power unit In a typical house only two inlet valves are needed. In such cases, the utility valve of the power unit can be used for cleaning the basement because it often covers the whole basement area. In the house of the same size, the power unit is in the garage, where the utility valve serves as a third inlet valve allowing you to clean your car, for example. Tubing System Design The main principle for designing the layout of the tubing system is to keep it as short as possible. This will give the highest possible vacuum performance. However, the main tube can be routed in different ways. The outside diameter of the tubing system is 2 (50.08mm) and is 2 1/8 (56mm) at the extension. The through-holes in the s must be 2 3/16 to 2 1/2 (55mm to 60mm) in diameter so that the extension and the lowvoltage cable can also go through the opening. The minimum diameter of the exhaust tube is 2 1/8 (56mm). New One-Story Houses The horizontal main tube is placed in the under-house crawl space or in the attic. In the under-house crawl space, the tubing should be insulated. Tubes to the inlet valves are routed in the partition s or between secondary spaces, such as closets. In a cold attic, the tubes should be covered with insulation in order to avoid condensation. Two- or Multi-Story Houses The main tube is placed in the under-house crawl space, attic, closet, between s, etc. Existing Houses The main tube can be installed on the surface in existing secondary spaces, such as a garage or storage room. The tube can also be routed through the attic and then vertically inside the partition s and closets all the way to the inlet valves. A lowered ceiling and closet footings can also be used for routing of the tubes. In this example, the main tube has been routed under the house. However, the tube in the under-house crawl space should be insulated to avoid condensation. The whole area can often be vacuumed from one single inlet valve. The light, broken line indicates an alternative installation type. In this example, the simplest solution is to route the tubing in the attic. If the space is cold, the main tube should be insulated. It is recommended to place the inlet valves in between different levels. In such cases, you can easily clean two levels from one inlet valve. The power unit is placed in the storage room.

4 electrolux installation manual Installation of the Wall Inlet Valves For the installation, you will usually need the following parts: min. 2 3/4 (65 mm) inlet valve Inlet valve Mounting bracket Wall Installation of the Inlet Valve A typical inlet valve installation is shown in the figure on the right. A 90 inlet elbow is used in the installation to prevent long objects entering into the tubing system, protecting it against blockages. A 90 steep elbow can be fitted in two different ways. In practice, the partition can be as narrow as 2 3/4 (65mm). choose the best angle of the 90 inlet elbow so that it fits best in the surrounding space Note! A 90 inlet elbow must not be installed anywhere else in the tubing system. If the thickness of the board is more than 1 (25mm), you can reach the by using an extension tube. open cavity low voltage cable 90 sweep elbow long screw inlet vavle seal If the Structures of the House Prevent Tubing Routing This can be avoided by making slots as shown in the figure below. Supporting structural elements of the house should not be slotted. If you cannot attach the properly to the batten, you can install a separate mounting board. mounting board short screw 1/4-1 (5 25 mm) sweep elbow Note! When installing the short version of the 90 inlet elbow, use short screws so that they do not extend into the tube.

electrolux installation manual 5 2 3/8 (60 mm) 4 3/4 (110 mm) Thread the low voltage cable through the slot in the low voltage cable min. 5/8 (15 cm) 2 1/4-2 1/2 (57 62 mm) Inlet Hole Make a hole in the board material for the inlet valve as shown in the figure. The size of the rectangular opening should be 2 3/8 x 4 3/4 (60mm x 110mm). In existing houses where tubes are routed underneath, a hole can be drilled for the tube using a guide hole as a template. Glue the 90 inlet elbow onto the sleeve of the. Leave a gap of approximately 5/8 (15cm) for the low-voltage cable to be connected to the inlet valve. Then the dust tube is glued into the inlet elbow. mounting bracket Do not disconnect the mounting screws completely. Loosen them enough to fit the low voltage cable around them and then tighten. long screw low voltage cable Installation in a Brick or Concrete Wall When installing the inlet valve, sink the s, the inlet elbow, and the in the so that the highest surface of the mounting bracket is approximately 1/4 (5mm) deeper than the final inner surface. For the tubing system, make a 3 1/8 x 3 1/8 (80mm x 80mm) channel in the brick or concrete independent of the final thickness of the. The tubing installation must be sturdy enough so that tubes and parts do not move out of their positions later during the installation work. It is recommended to cover the opening of the inlet valve to protect it from cast material. hook short screw 3 1/8 (80 mm) inlet vavle Strip off approximately 1 (2cm to 3cm) of the insulation from the end of the low-voltage cable. Roll the end of the cable two turns around the screws in the inlet valve and tighten the screws. Screw the inlet valve into the and make sure that the screw does not extend through the tube. If necessary, use shorter screws. In a complete structure, the is held in place by a hook as shown in the figure. mounting bracket finished surface 4 3/4 (110 mm) 2 3/8 (60 mm) The tube can also be installed block / brick with the rear side. In this case, the is made imurasiaa for a picture with the hole.

6 electrolux installation manual Floor Installation of the Inlet Valve This is usually the only possible installation method in existing houses. Note! When installing the inlet valve and tubing system in the, make sure that long sticks etc. do not to fall into the tubing. Installation in a Closet Wall Choose a location and make a 2 1/8 x 2 3/4 (55mm x 70mm) opening for the inlet valve. For the tube, a 2 3/8 (60mm) diameter hole is needed. Drill a hole for the tube also in the of the closet. Cut the tube to the proper length and glue it into the rebuilding sleeve. 2 1/4 (55 mm) installation hole interior 2 1/4 (55 mm) 2 3/8 (60 mm) 2 3/4 (70 mm) 2 3/4 (70 mm) inlet valve installation with extension closet insulation tubing closet 2 1/4-2 1/2 (57 62 mm) tubing For a installation, it is recommended to use the method shown in the figure, if applicable. It is the same as for the installation. The 90 inlet elbow prevents long objects from accessing the tubing system. For this method to be successful, the allowance under the should be at least 2 2/3 (65mm). Insert the tube into the round hole with the sleeve/rebuilding sleeve first so that it extends through the outer of the closet. Mount the inlet valve in the rebuilding sleeve. Measure and cut the tube to the proper length so that it reaches with the inlet elbow to the vertical tube. installation with extension For installation, it is possible to use the sleeve or rebuilding sleeve. In such cases, the is not needed. inlet valve inlet valve 1/4-1 (5 25 mm) 2 3/4 (65 mm) insulation interior room interior closet

electrolux installation manual 7 Tubing System Installation Important notes for installation! 1) The 90 inlet elbow may be installed only together with the mounting bracket and the inlet valve. Anywhere else in the tubing system, 90 sweep elbows and 45 elbows should be used. (Fig. A and B) 90 sweep elbow Begin the main tube installation with the farthest inlet valve and place the tubes temporarily at first. Do not glue the joints yet until you have made sure that the tubing routing is correct. The glue will dry quickly; therefore, the joints have to be fitted right after applying the glue. When measuring the tubes, take into account that the tube goes approximately 2/3 (18mm) into the sleeve and approximately 7/8 (20mm) into the extension tube. The tubing system can also be installed in a that will be concrete casted later on (Fig. F). In such cases, the low-voltage cable must be protected by a conduit. The conduit should be attached to the vacuum tube or the casting net. For the vacuum tube, the routing channel has to be 2 wide (51mm). The ends of the vacuum tubes and the conduit s should be plugged before concrete casting. 2 (51 mm) wire mesh A B 2) Tubes are cut straight so that the cutting line is not slanted. Use a miter saw if possible. Cut edges can be finished with a knife (to remove burrs). 3) For tubing joints, use suitable PVC glue to make the fittings secure and tight. Apply a thin and even layer of glue only to the end of the tube not to the sleeve. This will prevent the glue from overflowing to the end face of the tubing. Close the glue can carefully immediately after use and make sure to have adequate ventilation during installation. Avoid inhaling glue vapors. Insert the tube all the way into the sleeve while turning it at the same time (Fig. C). min. 3/4 (18 mm) concrete sand F vacuum electrical tube Installation Examples C push the completely into the fitting 4) The inlet is made through the fire according to Fig.figure E or by using a 2 (50mm) diameter fire cuff (Fig. D). Check the inlet with a fire authority. fire stopping collars correct correct vacuum D collars are attached to the incorrect protects the combustible building material min. 7 7/8 (200 mm) correct vacuum E steel protective sleeve min. 1/ 16 (2 mm) incorrect incorrect

8 electrolux installation manual Notes! Minimize Condensation If the tubing installation is carried out in winter, a large amount of condensation may be generated. To reduce the amount of condensation, close all holes and inlet openings using duct tape during installation. Before starting to use the central vacuum system for the first time, let the system vacuum and circulate fresh air for a few minutes, and make sure that there is no water in the dust container. If there is water in the container, drain it and continue vacuuming until no more water is accumulated. 45 elbow Example showing piping with different types of connections. 90 sweep T 90 sweep T 45 elbow connector 90 sweep elbow 45 single Y 90 sweep elbow VacPan Installation VacPan is most useful in the kitchen, in the hallway, etc. It can be easily installed, for example, in a cabinet footing or next to the. VacPan dimensions: 7 1/2 (190 mm) Example of a VacPan installed in a cabinet. maintenance access required cabinet piping may exit the cabinet and go vertical 2 1/4 (53 mm) 8 5/8 (215 mm) 1 9/16 (40 mm) min. 4 (100 mm) VacPan 2 3/4 (70 mm) 4 (99 mm) DO NOT GLUE 2 3/4 (70 mm) 6 1/2 (165 mm) low voltage connections switch installation using flexible vacuum tube front edge is flush with surface central vacuum starts when switch is activated additonal cover plate is available 90 sweep elbow

electrolux installation manual 9 Exhaust Blow-Out Because the exhaust tube must be as short as possible, it is recommended to place the power unit as close to an outside as possible. Shown below are examples indicating how to install the exhaust tube. The exhaust muffler can be installed upwards, downwards, as well as horizontally. roof ceiling ceiling exterior Min. 30cm (12 ) insulation exterior ceiling additional silencer exhaust valve Min. 30cm (12 ) exterior Min. 70cm (27.5 )

10 electrolux installation manual Electrical Connection- Low-Voltage Cable To power on the central vacuum system, a 24V low-voltage cable is routed to each inlet valve. Parallel connection is made according to the figure below. inlet valve1 inlet vavles conneted in series low voltage cable inlet valve 2 inlet valve 3 low voltage circuit diagram contact pins low voltage cable with stripped ends low voltage cable inlet valve low voltage connetion terminals It is recommended that the low-voltage cable be installed in a conduit, and this is absolutely necessary when cables are to be hidden in cast concrete. If the cable becomes defective, it is also much easier to change it afterwards. In these installations, only certified electrical components may be used. The power unit is connected to an electrical outlet. If there is no outlet nearby, an electrician will carry out installation. All the high-voltage connections are under the turbine cover. Only an electrician is allowed to open the cover.

Electrolux Central Vacuum Systems 10200 David Taylor Drive Charlotte, NC 28262 United States of America www.electroluxcentralvac.com The Thoughtful Design Innovator. Do you remember the last time you opened a gift that made you say, Oh! How did you know? That s exactly what I wanted! That s the kind of feeling that we at Electrolux seek to evoke in everyone who chooses or uses one of our products. We devote time, knowledge, and a great deal of thought to anticipating and creating the kind of appliances that our customers really need and want. This kind of thoughtful care means innovating with insight. Not design for design s sake, but design for the user s sake. For us, thoughtful design means making appliances easier to use and tasks more enjoyable to perform, freeing our customers to experience the ultimate 21st century luxury: ease of mind. Our aim is to make this ease of mind more available to more people in more parts of their everyday lives, all over the world. The Thinking of you promise from Electrolux goes beyond meeting the needs of today s consumers. It also means we re committed to making appliances safe for the environment now and for future generations. Electrolux. Thinking of you. Share more of our thinking at www.electrolux.com