3G3HV inverter. General. System architecture

Similar documents
EFC Frequency converters

Frequency Converter Fv

J1000. System configuration

How To Use The Vacon 0 Machinery

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Manual No. YEG-TOE-S OY. VARISPEED F7 Vector Control Frequency Inverter USER S MANUAL

Number 1 in efficiency

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Electronic Control Devices The European Product Catalogue 2007

32VFD Variable Frequency Drives for Centrifugal Chillers

TRAMS TROLLEY-BUSES SUBWAY

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Thyristor-controlled power supplies and battery chargers

Electronic Control Devices The European Product Catalogue 2007

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Photovoltaic Solar Energy Unit EESFB

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

NXL Series Inverters. HVAC Inverters made simple

TIG INVERTER INSTRUCTION MANUAL

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Easy to connect - Easy to configure Easy to install

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Specifying a Variable Frequency Drive s

A1000 Cheat Sheet (Open Loop Vector)

WIND TURBINE TECHNOLOGY

3G3JX AC DRIVES Compact and complete

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

NX Series Inverters. HVAC Pocket Programming Guide

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Telephone- and leased line modem for industrial applications TD-36

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

NX safety stand-alone

UIM2901-5A MACH3 breakout board

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

EET272 Worksheet Week 9

Inductive Proximity Sensors

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

On-line Machine Condition Monitoring [The CMS System]

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

FRENIC5000MS5 for Machine Tool Spindle Drives

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

TAKEDO -3VF V20 INSTRUCTION MANUAL REL. DATE T.M. Check and Approval

vacon 100 x & vacon 20 x decentralized ac drives

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Research RF Sputtering Packages

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Smart DeviceNet Remote I/O Terminals

VS mini J7. USER S Manual. Compact General Purpose Inverter. VS mini J7

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

Variable speed drives

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

KONSTANTER SPL / SPL Programmable Electronic Load

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

GPD 506/P5 Start-up Procedure and Checklist

ELECTROMAGNETIC DISC BRAKES

3-phase, bidirectional energy meter

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

650W Single Output Power Supply

ABB general machinery drives. User s manual ACS355 drives

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

with Electronic Assistant

Rack mounted telephone- and leased line modem for industrial applications

R.C.C.B. s two-pole LEXIC

Model: DC-A2IO Advanced HVAC Controller

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

EnVisioneering.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

BG or BGE Brake Rectifier

Quick Connect. quick - simple - efficient.

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Electric Rotary Actuator - On/Off or programmable control actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

Talon and Talon SR User Manual

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

High Power Programmable DC Power Supplies PVS Series

User manual Rev 1.3 Contents

Analog Servo Drive 25A8

Special Accessories. Sydrive Configurator software. 3G3IV-PCN126/326 Digital Operator Extension Cable

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Transcription:

General he 3G3HV is designed in particular for applications with quadratic power requirement. Pumps and ventilators are always operated with the highest efficiency by means of a self-adapting energy saving function. Features: - power range: 0,4...300 kw - PID controller - self-adapting energy saving function - NPN or PNP digital inputs - analog frequency default: 0...10 VDC or 4...20 ma - high continuous output current - low noise thanks to high carrier frequency (adjustable to 15 khz) - built-in programming unit - MODBUS interface RS-422/-485 - built-in DC reactor above 15 kw - 12 pulse rectifier above 15 kw System architecture o comply with relevant MC guidelines it is imperative for Variable-frequency inverters always to be operated with appropriate line filters and according to the relevant installation instructions. Voltage supply L1 L2 L3 P Shielding Contact surfaces to the metal plate Switch cabinet assembly on metal plate filter, footprint type Shielding U V W P M 1

Product overview Inverter: 200 V Class: Model 3G3HV -AB_ -C 3G3HV -A B004 B007 B015 B022 B037 Maximum allowed motor output kw 0,55 1,1 1,5 2,2 3,7 Output data Inverter performance kva 1,2 2,3 3,0 4,2 6,7 Output rated current A 3,2 6 8 11 17,5 Inverter: 400 V Class: Model 3G3HV -A4_ -C 3G3HV -A 4004 4007 4015 4022 4037 4040 4055 4075 4110 4150 Maximum allowed motor output kw 0,55 1,1 1,5 2,2 3,7 4,0 5,5 7,5 11 15 Output data Inverter performance kva 1,4 2,6 3,7 4,7 6,1 8,4 11 14 21 26 Output rated current A 1,8 3,4 4,8 6,2 8 11 14 18 27 34 3G3HV -B 4185 4220 4300 4370 4450 4550 4750 411K 416K Maximum allowed motor output kw 18,5 22 30 37 45 55 75 110 160 Output data Inverter performance kva 31 40 50 61 73 98 130 170 230 Output rated current A 41 52 65 80 96 128 165 224 302 3G3HV -B 418K 422K 430K Maximum allowed motor output kw 185 220 300 Output data Inverter performance kva 260 340 460 Output rated current A 380 506 675 Accessories filter filter Rated voltage filter Current* 3G3HV -AB004 -C 1 x 230 VAC 3G3HV -PFI1010-10 A 3G3HV -AB007 -C and 3G3HV -AB015 -C 1 x 230 VAC 3G3HV -PFI1020-20 A 3G3HV -AB022 -C and 3G3HV -AB037 -C 1 x 230 VAC 3G3HV -PFI1040-40 A 3G3HV -A4004 -C and 3G3HV -A4007 -C 3 x 400 VAC 3G3FV -PFI4012 -* 12 A 3G3HV -A4015 -C 3 x 400 VAC 3G3FV -PFI4012 -* 12 A 3G3HV -A4022 -C 3 x 400 VAC 3G3FV -PFI4012 -* 12 A 3G3HV -A4037 -C and 3G3HV -A4040 -C 3 x 400 VAC 3G3FV -PFI4012 -* 12 A 3G3HV -A4055 -C 3 x 400 VAC 3G3FV -PFI4025 -* 25 A 3G3HV -A4075 -C 3 x 400 VAC 3G3FV -PFI4025 -* 25 A 3G3HV -A4110 -C 3 x 400 VAC 3G3FV -PFI4040 -* 40 A 3G3HV -A4150 -C 3 x 400 VAC 3G3FV -PFI4040 -* 40 A 3G3HV -B4185 -C and 3G3HV -B4220 -C 3 x 400 VAC 3G3FV -PFI4060-60 A 3G3HV -B4300 -C and 3G3HV -B4370 -C 3 x 400 VAC 3G3FV -PFI4100-100 A 3G3HV -B4450 -C 3 x 400 VAC 3G3FV -PFI4120-120 A 3G3HV -B4550 -C 3 x 400 VAC 3G3FV -PFI4150-150 A 3G3HV -B4750 -C 3 x 400 VAC 3G3FV -PFI4180-180 A 3G3HV -B411K -C 3 x 400 VAC 3G3FV -PFI4280-280 A 3G3HV -B418K -CU 3 x 400 VAC 3G3FV -PFI4450-450 A 3G3HV -B418K -CU 3 x 400 VAC 3G3FV -PFI4450-450 A 3G3HV -B422K -CU 3 x 400 VAC 3G3FV -PFI4600-600 A 3G3HV -B430K -CU 3 x 400 VAC 3G3FV -PFI4900-900 A * footprint type 2

Accessories (continued) Brake choppers, braking resistors Inverter Rated voltage Brake chopper Number Braking resistors Number Specification for each unit for inverter, single-phase 230 V 3G3HV -AB004 -C 1 x 230 VAC built-in - 3G3IV -PRF150W -J620 1 62 W, 150 W 3G3HV -AB007 -C 1 x 230 VAC built-in - 3G3IV -PRF150W -J620 1 62 W, 150 W 3G3HV -AB015 -C 1 x 230 VAC built-in - 3G3IV -PRF150W -J620 1 62 W, 150 W 3G3HV -AB022 -C 1 x 230 VAC built-in - 3G3IV -PRF150W -J620 1 62 W, 150 W 3G3HV -AB037 -C 1 x 230 VAC built-in 3G3IV -PRF150W -J620 1 62 W, 150 W for inverter, three-phase 400 V 3G3HV -A4004 -C 3 x 400 VAC built-in - 3G3IV -PRF150W -J101 1 100 W, 150 W 3G3HV -A4007 -C 3 x 400 VAC built-in - 3G3IV -PRF150W -J101 1 100 W, 150 W 3G3HV -A4015 -C 3 x 400 VAC built-in - 3G3IV -PRF150W -J101 1 100 W, 150 W 3G3HV -A4022 -C 3 x 400 VAC built-in - 3G3IV -PRF250W -J680 1 68 W, 250 W 3G3HV -A4037 -C 3 x 400 VAC built-in - 3G3IV -PRF500W -J360 1 36 W, 500 W 3G3HV -A4040 -C 3 x 400 VAC built-in - 3G3IV -PRF500W -J360 1 36 W, 500 W 3G3HV -A4055 -C 3 x 400 VAC built-in - 3G3IV -PRF500W -J360 1 36 W, 500 W 3G3HV -A4075 -C 3 x 400 VAC built-in - 3G3IV -PRF101W -J360 1 36 W, 1000 W 3G3HV -A4110 -C 3 x 400 VAC built-in - 3G3IV -PRF151W -J200 1 20 W, 1500 W 3G3HV -A4150 -C 3 x 400 VAC built-in - 3G3IV -PRF151W -J200 1 20 W, 1500 W Other Description Cable length Product Adapter for front panel installation, fixed mounting of console - 3G3FV -PDAC -AD Adapter for front panel installation, removable console - 3G3FV -PDAC -BD xtension cable to programming console 1 m 3G3FV -PCN125 xtension cable to programming console 3 m 3G3FV -PCN325 Ferrite rings for output, D = 21 to 58 mm - 3G3IV -PFO -OC1 -OC4 3

Programming accessories PC programming Description Cable length Product Programming software under WINDOWS - SYSDRIV Configurator Connecting cable 2 m 3G3FV -PCNDW225N echnical data ype 3G3HV -A4_ -C 3G3HV -B4_ -( -C) 3G3HV -AB_ -C Output data Max. output voltage three-phase: 380/400/415/440/460 V (prop. to input volt.) three-phase: 200-240 V (prop. to input volt.) Supply Output frequency Rated input voltage and frequency 0,1 Hz to 400 Hz Allowed voltage variation +10%, -15% Allowed frequency variation 5% Control functions ype of control sinusoidal pulse width modulation (PWM) Protective functions Output frequency range three-phase: 380/400/415/440/460 V, 50/60 Hz three-phase: 200-240 V, 50/60 Hz 0,1-400 Hz Frequency precision digital default: 0,01% ( -10 C to +40 C) analog default: 0,1% (25 C 10 C) Frequency resolution Output frequency resolution Overload capacity digital default: 0,1 Hz analog default: 0,05 Hz, 50 Hz (10 Bits) 0.01 Hz 150% of the output rated current for 1 minute Frequency reference value signal 0-10 VDC (20 kw), 4-20 ma (250 W) Acceleration/deceleration Braking torque U/f characteristics Protection against motor overload Instantaneous overcurrent Overload Overvoltage Undervoltage Supply voltage failure Cooling fin overheating Stall prevention arth fault Charge indicator 0,0 bis 3600 s (can be programmed independently) about 20% (with braking resistor up to 125%) 120% of the output rated current for 1 minute 150% for 12 s about 20% 15 already programmed and one freely programmable characteristic thermo-electronic protection against overload stops at approx. 200% of rated output current at 150% of the output rated current the motor coasts to stop after 1 minute stops when main circuit DC voltage is approx. 820 V stops at approx. 180% of rated output current at 120% of the output rated current the motor coasts to stop after 1 minute stops when main circuit DC voltage is approx. 380 V (400 V model) after failure of longer than 15 ms the output switches off. After the return of voltage operation can be automatically continued. protection by thermistor stall prevention during the acceleration and braking phase, and also during constant frequency operation via electronic circuit the charge indicator lights up until the intermediate circuit voltage falls under 50 V 4

echnical data (continued) ype 3G3HV -A4_ -C 3G3HV -B4_ -( -C) 3G3HV -AB_ -C Ambient conditions Ambient temperature during operation Air humidity Storage temperature Place of assembly Vibrations -10 C to +45 C -10 C to +45 C -10 C to +45 C 90% RH (without condensation) -20 C to +60 C inside ( protected against corrosive gases and dust) 1 G at 0...20 Hz 0,2 G at 20...50 Hz Connections diagram 200 V Class, 0,4...3,7 kw, single-phase Voltage supply 200...240 VAC, 50/60 Hz DC reactor (optional) Braking resistor (optional) fuse contactor filter +1 +2 - B1 B2 L1 N U V W M 3-phase PNP connection input 1 input 2 input 3 input 4 input 5 NPN connection input 1 input 2 input 3 input 4 input 5 AM AC analog output Analog output, mass SP 24 V SC SC 0 V SP 24 V Auxiliary voltage 15 V, 20 ma Ref. value input 1, 0...10 V (main frequency ref. value) Ref. value input 2, 4...20 ma FS FV FI MA MB MC output 1 contact output (contact a) contact b Common Ref. common Serial interface RS-485/-422 (shielded in pairs) FC (R+) (R-) (S+) (S-) M1 M2 output 2 5

Connections diagram (continued) 400 V Class, 0,4...15 kw, three-phase 380...460 VAC, 50/60 Hz three-phase DC reactor (optional) Braking resistor (optional) fuse contactor filter +1 +2 - B1 B2 R S U V W M 3-phase PNP connection input 1 input 2 input 3 input 4 input 5 NPN connection input 1 input 2 input 3 input 4 input 5 AM AC analog output Analog output, mass SP 24 V SC SC 0 V Auxiliary voltage 15 V, 20 ma Ref. value input 1, 0...10 V (main frequency ref. value) Ref. value input 2, 4...20 ma SP FS FV FI 24 V MA MB MC output 1 contact output (contact a) contact b Common Ref. common Serial interface RS-485/-422 (shielded in pairs) FC (R+) (R-) (S+) (S-) M1 M2 output 2 6

Connections diagram (continued) 400 V Class, 18,5...300 kw, three-phase - Brake chopper on demand. 380...460 VAC, 50/60 Hz three-phase fuse contactor filter R S U V W M 3-phase PNP connection input 1 input 2 input 3 input 4 input 5 NPN connection input 1 input 2 input 3 input 4 input 5 R1 1 AM AC analog output Analog output, mass SP 24 V SC SC 0 V SP 24 V Auxiliary voltage 15 V, 20 ma Ref. value input 1, 0...10 V (main frequency ref. value) Ref. value input 2, 4...20 ma Ref. common FS FV FI FC MA MB MC output 1 contact output (contact a) contact b Common Serial interface RS-485/-422 (shielded in pairs) (R+) (R-) (S+) (S-) M1 M2 output 2 7

echnical documentation SYSDRIV INVRR nglish documentation Product itle Product 3G3HV User Manual I515-1 -2 Installation Manual I520-1 -1 OPRAION MANUAL Dimensions (mm) Inverter 3G3HV -AB_, 200 V single-phase B B1 H H1 Weight kg Product 140 126 280 266 160 3 004 -C 140 126 280 266 180 4,5 007 -C 140 126 280 266 180 4,5 015 -C 200 186 300 285 205 6 022 -C 200 186 300 285 205 6 037 -C 3G3HV -A4_, 400 V three-phase, up to 15 kw H1 H B B1 H H1 Weight kg Product 140 126 280 266 160 3 004 -C 140 126 280 266 160 3 007 -C 140 126 280 266 180 4 015 -C 140 126 280 266 180 4,5 022 -C 140 126 280 266 180 4,5 037 -C 140 126 280 266 180 4,5 040 -C 200 186 300 285 205 6 055 -C 200 186 300 285 205 6 075 -C 250 236 380 365 225 11 110 -C 250 236 380 365 225 11 150 -C B1 B 8

Dimensions (mm) (continued) Inverter 3G3HV -B_, 400 V three-phase, >15 kw B B1 H H1 Product 325 275 450 435 285 4185 -C 325 275 450 435 285 4220 -C 325 275 625 610 285 4300 -C 325 275 625 610 285 4370 -C 325 275 625 610 285 4450 -C 455 350 820 795 350 4550 -C 455 350 820 795 350 4750 -C 575 445 925 895 375 411K-C 575 445 925 895 400 416K-C 950 * 1450 1400 435 418K-CU 950 * 1450 1400 435 422K-CU 960 * 1600 1550 455 430K-CU * on demand B1 B H1 H filter 3G3HV -PFI_, 200 V single-phase, mountable underneath up to 15 kw B B1 H H1 Product 143 90 320 310 46 1010-143 90 320 310 46 1020-213 150 320 310 51 1040-3G3FV -PFI_, 400 V three-phase, mountable underneath H1 H B B1 H H1 Product 143 90 320 310 40 4012-213 150 350 330 40 4025-266 200 435 415 55 4040 - B1 B 3G3FV -PFI_, 400 V three-phase from 18,5 kw B B1 H H1 Product 140 106 270 258 90 4060-180 146 350 338 90 4100-200 166 420 408 130 4120-200 166 420 408 130 4150-200 166 480 468 160 4180-200 166 480 468 160 4280-250 170 587 560 205 4450 - H1 H B1 B 9