AGC Dynamic Range Data Rates 33,600; 31,200; 28,800; 26,400; 24,000; 21,600; 19,200; 16,800; 14,400; 12,000; 9600; 7200; 4800; 2400; 1200; bps

Similar documents
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

LS-101 LAN to Serial Device server. User s Manual

RS-232 COMMUNICATIONS

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

LOW COST GSM MODEM. Description. Part Number

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

System Requirements. Hiro H50113

Using HyperTerminal with Agilent General Purpose Instruments

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

WHQL Certification Approval...2 User Interface K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5

PROPRIETARY INFORMATION NOTICE

Quectel Cellular Engine

HOW TO USE YOUR INTELE-MODEM

Date Rev. Details Author

Connecting the Console Port to a PC

Teleservice via RS232 interface XC100/XC200

version 3.1. Security modem with USB port user guide

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

V.90 (V.92 Upgradeable) 56K PCI Modem User s Guide

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

Telephone- and leased line modem for industrial applications TD-36

Cable Specifications and Information

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

Rack mounted telephone- and leased line modem for industrial applications

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

SWITCHED TELEPHONE NETWORK LEASED LINE

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

I-modem Command Reference

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

Vector F336E/2LL MODEM USER'S MANUAL

Advanced Data Capture and Control Systems

Bluetooth HC-06 with serial port module Easy guide

How to setup a serial Bluetooth adapter Master Guide

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Application Note 83 Fundamentals of RS 232 Serial Communications

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Serial over Ethernet Device Server. User s Manual

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

MODBUS TCP to RTU/ASCII Gateway

MODBUS TCP to RTU/ASCII Gateway. User s Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PCMCIA 1 Port RS EDITION OCTOBER 1999

Moxa TCC-100/100I User s Guide

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

PCM-3600 PC/104 Fax/Modem Module

PHONE MANAGER INDEX. page

SyncLink GT2/GT4 Serial Adapter

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

300/75,1200, 2400bps Asynchronous Bell103/212 - CCITT V.22, V.22bis QUAM in 2400bps, DPSK in 1200bps, FSK in 0-300bps

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Industrial Multi-port Serial Cards

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

IP SERIAL DEVICE SERVER

One Port Serial Server Users Manual Model ESP901, ESP901E

Modbus Communications for PanelView Terminals

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Bluetooth to Serial Adapter

Modem and Local Area Networks. Document Part Number:

How To Run An Nport I5000A Device Server

Cabling Guide for Console and AUX Ports

PCS0100en Persy Control Services B.V. Netherlands

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Cable Specifications and Information

RTU-COM with GSM. User Notes and Short Form AT Commond Survey

Using Xbee in Serial Communication

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

CENTRONICS interface and Parallel Printer Port LPT

AUTODIALLER / QUICKDIALLER - SA132

Why you need to monitor serial communication?

Configuration Guide for Ascom Communications Server, Remote Management Package

Serial to Bluetooth Adapter

isco Connecting Routers Back to Back Through the AUX P

Modem and Local Area Network

Using the Teridian 73M2901CE in 4-Wire and Leased Line Applications

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

VOICE RECORDING SYSTEM ISDN PRI / BRI

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PSI-DATA/FAX-MODEM/RS232

NPort s Ethernet Modem Mode

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

User Manual IC-485AI

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Industrial Modem Designed for unattended sites

Objectives. Basics of Serial Communication. Simplex vs Duplex. CMPE328 Microprocessors (Spring ) Serial Interfacing. By Dr.

Transcription:

Description The Hidex II V.34bis Industrial Grade Modem is the most versatile model for Dial up or leased analog telephone line interconnect. The Hidex HX II 33T offers speeds up to 33.6K over the analog switched telephone network. They are temperature tested, rugged modems designed for Industrial applications. Directly connected to RTU s, traffic controllers, variable message signs or any number of other applications, they communicate at 300 bps to 33.6 kbps over analog telephone lines. All HX models have High voltage surge protection on the telephone lines. The power converter delivers 5VDC from 100 to 240 VAC, 50-60 Hz with World Wide safety approvals and a locking connector to prevent vibration disconnects. A wide voltage range of DC power models are optional. Features Category Description Client-to-Server Data Rates Supports V.34bis data rates AGC Dynamic Range 43 db Data Rates 33,600; 31,200; 28,800; 26,400; 24,000; 21,600; 19,200; 16,800; 14,400; 12,000; 9600; 7200; 4800; 2400; 1200; 0-300 bps Command Buffer 60 characters DAA Isolation 1500 Vac Data Compatibility V.34 enhanced, V.34, V.32bis, V.32, V.22bis, V.22; Bell 212A and 103/113, V.21 & V.23 Data Compression ITU-T V.44 (6:1 throughput); V.42bis (4:1 throughput); MNP 5 (2:1 throughputfax Compression MH, MR, MMR Data Format Serial, binary, asynchronous (available with parallel interface) Dimensions 5 x 3 x 1 inches plus mounting tabs Case Material Black zinc oxide plated steel Error Correction Data Mode: V.42 (LAP-M or MNP 3 4) Page 1 7/20/2005

Fax Compatibility ITU-T Super Group 3; Class 1.0 (2.0, 2.1 V.92 build only) Group 3, Class 1 and 2, T.4, T.30 Annex A & C, V.21, V.27ter, V.29, V.34, V.17, and TIA/EIA TR29.2 V.34 Super G3 fax at speeds up to 33.6Kbps V.17 G3 fax at speeds up to 14.4Kbps Fax mode error correction T.30 Annex A & C Fax Data Rates 33,600; 31,200; 28,800; 26,400; 24,000; 21,600; 19,200; 16,800; 14,400; 12,000; 9600; 7200; 4800; 2400; 1200; 0-300 bps Flow Control XON/XOFF (software), RTS/CTS (hardware) Operational Temperature 40 to +85 C ambient under closed conditions; humidity range 20 90% (non-condensing) Power Consumption Typical: TBD Standby or Sleep: TBD Maximum: TBD Receiver Sensitivity 43 dbm under worst-case conditions Serial Speeds Serial port data rates adjustable to 300, 1200, 2400, 4800, 9600, 19,200, 38,400, 57,600, 115,200, and 230,400 bps Storage Temperature 50 to +100 C Model Number: HX II 33T Registration No: AU7USA-25814-M5-E Ringer Equivalence: 0.3B Modular Jack (USOC): RJ11 Intelligent Features Fully AT command compatible, Leased-line operation, Sleep mode Autodial, redial, Pulse or tone dial, Dial pauses, Auto answer Adaptive line probing, Automatic symbol and carrier frequency during startup, retrain, and rate renegotiations. DTMF detection, Distinctive ring, Call status display, auto-parity and data rate selections Keyboard-controlled modem options, On-screen displays for modem option parameters, remote configuration, DTR dialing, phone number storage flash memory for firmware updates, NVRAM storage for user-defined options Compliance to Global Telephone Standards Hidex II modems have passed the following homologation: FCC Part 68 FCC Part 15 IC-CS03 ETSI TS 103 021-1,2,3 v.1.1.2 2003-09 (originally CTR21) ESD Page 2 7/20/2005

Power Supply 5 volt DC power to the modem is supplied through a 2-pin locking connector. Included with each modem is a switching power supply that will accept 90 to 240 VAC or DC. If you are going to power the modem from 5VDC remove the connector and attach to another pair of wires to connect to 5 VDC. CAUTION NOTE THE POLARITY ON THE CONNECTOR. The wire with the white dashes along the wire edge is the negative side. An alternate power connection is available via pin 10 and pin 1 on DB25 connector. Simply connect the minus (ground) wire to pin 1 and the plus +5VDC to pin 10. Data Interface Data is interfaced via a DB25 female connector. Pin 1 GRD Pin 2 TXD Pin 3 RXD Pin 4 RTS Pin 5 CTS Pin 6 DSR Pin 7 SG Pin 8 DCD Pin 10 Pin 20 DTR Pin 22 RI Signal Ground Transmit Data Receive Data Request to Send Clear to Send Data Set Ready Signal Ground Carrier Detect (Alternate power input +5VDC) Data Terminal Ready Ring Indicate LED Indicators DCD Data Carrier Detect RTS Request To Send CTS Clear To Send TXD Transmit Data RXD Receive Data RI/DSR Ring Indicate/Data Set Ready DTR Data Terminal Ready Hardware Setup: Setup Procedure: 1. Use the RS-232 cable to connect the DB25 connector (J1) on the modem to a PC serial port (Typically COM1). Page 3 7/20/2005

2. Connect the RJ11 connector to a phone line. 3. Connect external power to the power jack via wall adapter or +5VDC. Hyper Terminal setup: The modem can be tested as a standard serial data modem by connecting it to a personal computer or other data terminal equipment (DTE). Any standard terminal program such as HyperTerminal or ProComm running on a PC will communicate with the modem. Procedure to setup HyperTerminal: Check if HyperTerminal is installed in your PC. If not, see HELP on Windows Operating System for HyperTerminal installation. 1. Start -> Program -> Accessories -> Communications -> HyperTerminal When the HyperTerminal is opened for the first time, the application will ask for a title for storing all parameters you want to key in. After a title is given, there will be a prompt for the COM port to be used. Choose the corresponding port (COM1 is recommended). Then the port setting will be asked. Configure the terminal emulation program to 19200 bps, 8 data bits, no parity, one stop bit, and hardware (CTS) handshaking. 2. When the terminal program is properly configured and running, type AT<cr> inside the terminal window and the modem should return OK, indicating the modem is working in the command mode and communicating with the terminal. If the OK response is not received, try resetting the modem by pressing the manual reset switch (S1) then again type AT<cr>. If it is still not working, ensure that the right COM port is selected and make sure the correct port setting is entered. 3. If there is no line-feed after the OK response, click File->Properties. In the properties panel, choose Settings. In this panel, choose ASCII setup. In the ASCII panel, click the append line feeds to incoming lines. Click OK. You are now talking to one modem with the PC. 4. Use a similar procedure to setup the other modem with a different COM port. 5. Once the second modem is set up, the user can choose either one of the modems as the ANSWER modem. 6. If the modem is chosen as the ANSWER modem, type ATI6<cr>. The modem should respond with 2493, 2457, 2434, 2415, or 2404, indicating the terminal is communicating with a Hidex modem. 7. Type ATS0=2<cr>. It means answer the phone after the second ring. 8. To take the modem off-hook, type ATH1<cr>. The modem should go to the off-hook state, draw loop current, and respond with an OK. 9. Next type ATH<cr> or ATH0<cr> and the modem should hang-up (go on-hook) and stop drawing loop current. 10. To make a modem connection, type ATDT (called modem phone number)<cr>. Once the connection is established, a CONNECT message will appear indicating the two modems are in the data mode and communicating. Typing on one terminal should appear on the other terminal. Page 4 7/20/2005

11. To return to the command mode without interrupting the connection between the two modems, type +++. Approximately two seconds later, OK will appear. The modem is now in command mode and will accept AT commands. 12. To return to the data mode, type ATO<cr>. The modem will resume the data connection and no longer accept AT commands. 13. Type ATH<cr> (or ATH0<cr> ) to terminate the data connection. AT Commands AT refers to the command prefix (attention sequence) that precedes each command to the modem. With the exception of A/ all commands must be preceded by AT and end with a carriage return <return>. Some useful AT commands commonly used are: AT The attention command prefix, a set/reset command. ATA Answer ATDT101 Dial the number (101) ATH0 Forces the modem on-hook. Hangs up the modem s connection to the telephone line. ATH1 Forces the modem off-hook. ATI Information -asks the modem for its product ID code. ATO Goes online. ATS0=1 Set number of rings (1) before answering ATX0 Blind dial no dial tone necessary. AT*Y1D2 Send continuous DTMF digit (2). A/ Repeat last command The A/ command instructs the modem to repeat the last command line. A command line termination character is not required for the execution of this command (that is, the command is executed as soon as the slash is typed). +++ Return to command state (escape sequence) The escape sequence is used to force the modem back to the local command state from the on-line state Complete AT commands and programming The complete AT commands can be downloaded from the web address http://www.industrial-grade-modem.com/down_loads.htm and select HX II 33T user manual or AT commands manual. Table 10 17 index Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Table 16 Table 17 The basic AT Commands Extended AT& Commands Extended AT% Commands Extended AT\ Commands Result Codes S Register Descriptions User Access Registers (U-Registers) Bit Mapped U-Registers Summary Industrial Grade Modems 41 Wightman Ct. Dana Point, CA 92629 Phone: 949-481-6516 Fax: 949-270-1500 Page 5 7/20/2005

Email: sales@industrial-grade-modem.com Web: www.industrial-grade-modem.com Page 6 7/20/2005